TY - JOUR A1 - Wu, Z. A1 - Guo, X. A1 - Xie, G. A1 - Yan, T. A1 - Wu, Dejian A1 - Zhang, F. A1 - Ang, R. T1 - Heat and electric flux coupling of closed-loop thermoelectric generator N2 - Thermoelectric generator (TEG) has been proved as a promising technology for directly converting heat into electricity based on Seebeck effect. On the contrary, this electricity can trigger a solid-state cooling based on conventional Peltier effect. However, these two effects induce a coupling between heat and electric flux, especially for the quantitative relationship still remaining a mystery. Here, we show experimental evidence and theoretical calculation for the coupling by monitoring transient response of fluid temperature and output power. The experimental maximum heat flow in open circuit is 1162 W at cold fluid flow rate = 0.3 m3/h and fluid temperature difference ΔTf = 70 °C, enhanced by 13% owing to heat compensation from intrinsic coupling in closed-loop circuit. Meanwhile, the measured maximum output power of TEG is 18.2 W, and subsequently decreases to 15.4 W due to the objective existence of coupling. This double-edged sword in coupling vigorously inspires the potential applications in heat-dissipation situation such as spacecraft, electronic components, photovoltaic, refrigerator and etc. Present findings open a novel avenue for manipulating heat-electricity conversion in practical engineering. KW - Thermoelectric generator PY - 2021 U6 - https://doi.org/10.1016/j.enconman.2021.114529 SN - 0196-8904 VL - 244 SP - 1 EP - 13 PB - Elsevier Ltd. AN - OPUS4-53661 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Vogel, Justus A1 - Zhang, F. A1 - Long, N.X. A1 - Nguyen, T.P. T1 - Visibility of Image Quality Indicators (IQI) by Human Observers in Digital Radiography in Dependence on Measured MTFs and Noise Power Spectra N2 - Digital radiographic images were analysed to predict the visibility of image quality indicators (IQI), based on normalized noise power spectra (NNPP) and modulation transfer function (MTF) measurements. The fixed pattern noise of some digital detectors result in different noise spectra, which influence the visibility of different IQIs, depending on the hole diameter. Studies, based on measurement of basic spatial resolution and contrast to noise ratio were performed together with presampled MTF measurements and the NNPS in dependence on the spatial frequency. Plate hole IQIs, step hole IQIs, and equivalent penetrameter sensitivity (EPS) IQIs based on ASTM E 746 were measured to verify the influence of the different parameters. Modelling of digital images was used to verify the applied numeric tools. A study has been performed for imaging plates and digital detector arrays to analyse differences. Formulas for the prediction of the visibility functions for hole type IQIs are derived. In consequence the standards for characterization and classification of computed radiography (ASTM E 2446) and radiography with DDAs (ASTM E 2597) need to be revised. T2 - 12th ECNDT 2018 CY - Gothenburg, Sweden DA - 11.06.2018 KW - Image evaluation KW - Computed radiography (CR) KW - Digital Detector Array (DDA) KW - Detail detection PY - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-473486 UR - www.ndt.net/?id=22967 SN - 1435-4934 VL - 23 IS - 8 SP - 1 EP - 7 PB - NDT.net CY - Kirchwald AN - OPUS4-47348 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Zhang, F. A1 - Long, N.X. A1 - Phong, N. T1 - Essentielle Parameter zur numerischen Abschätzung der Sichtbarkeit von Bildgüteprüfkörpern in der digitalen Radiographie N2 - Die Voraussetzungen für die Vorhersage der Sichtbarkeit von Bildgüteprüfkörpern (BPK) wurden seit Beginn der kommerziellen Anwendung der technischen Radiographie diskutiert und in diversen nationalen und internationalen Standards festgeschrieben. Diese Fragen werden nach Einführung der digitalen Radiographie und der CT wieder neu diskutiert. Draht BPKs wurden in Deutschland seit 1935 (DIN 1915: 1935) und später in den meisten europäischen Ländern benutzt. In den USA und Frankreich wurden vorzugsweise BPKs mit Löchern verwendet (ASTM E 1025 seit 1984 oder E 1742 seit 1992 bzw. die Vorgängernorm MIL STD-543 seit 1962). Jetzt werden auch die Umrechnungsnormen zur Erkennbarkeit von Draht zu Loch-BPKs in Frage gestellt. ISO 19232-3, der französische RCCM-Kode einerseits und ASTM E 747 und ASME BPVC Section V Tab. T-276 andererseits unterscheiden sich erheblich bei den Anforderungen im Bereich hoher Wandstärken (Hochenergieradiographie). Untersuchungen dazu werden vorgestellt. Mit Einführung der digitalen Detektoren ändern sich auch die Rauschspektren. Durch die Herstellung werden insbesondere bei Speicherfolien "Rauschmuster" eingeprägt, die bei hohen Belichtungsdosen sichtbar werden. Diese veränderten Rauschspektren ergeben auch veränderte Erkennungsparameter für menschliche Bildauswerter. Hierzu wurden an ausgewählten Detektoren MTFs (presampled) und normierte Rauschspektren gemessen. Erweiterte Erkennbarkeits-Formeln zur Vorhersage der Sichtbarkeit von BPKs für Bildauswerter und erste Ergebnisse werden vorgestellt. T2 - DGZfP-Jahrestagung 2018 CY - Leipzig, Germany DA - 07.05.2018 KW - Image quality KW - Computed radiography (CR) KW - Digital Detector Array (DDA), KW - Sichtbarkeit von Anzeigen PY - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-473496 UR - www.ndt.net/?id=23069 VL - 2018 SP - 1 EP - 14 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-47349 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -