TY - CONF A1 - Bütefisch, S. A1 - Weimann, T. A1 - Busch, I. A1 - Danzebrink, H.-U. A1 - Gross, Thomas A1 - Unger, Wolfgang A1 - Wirth, Thomas T1 - New reference material for imaging XPS (X-ray photoelectron spectroscopy) instrument characterization N2 - Reference materials without variations in topography are essential for the characterization of imaging XPS (X-ray Photoelectron Spectroscopy) Instruments. Therefore a new fabrication process for this kind of zero-topography reference material was developed at PTB and resulted in first prototypes. The fabrication process and first measurement results will be presented in this paper. T2 - Sensor 2015 - 17th International conference on sensors and measurement technology CY - Nuremberg, Germany DA - 19.05.2015 KW - Imaging XPS KW - Reference material KW - Topography free KW - Micro technology PY - 2015 SN - 978-3-9813484-8-4 DO - https://doi.org/10.5162/sensor2015/P7.1 SP - Chapter P7, 821 EP - 825 AN - OPUS4-33837 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rades, Steffi A1 - Wirth, Thomas A1 - Unger, Wolfgang T1 - Investigation of silica nanoparticles by Auger electron spectroscopy (AES) N2 - High-priority industrial nanomaterials like SiO2, TiO2, and Ag are being characterized on a systematic basis within the framework of the EU FP7 research project NanoValid. Silica nanoparticles from an industrial source have been analyzed by Auger electron spectroscopy. Point, line, and map spectra were collected. Material specific and methodological aspects causing the special course of Auger line scan signals will be discussed. KW - Nanoparticles KW - Auger electron spectroscopy KW - Surface analysis PY - 2014 DO - https://doi.org/10.1002/sia.5378 SN - 0142-2421 SN - 1096-9918 VL - 46 IS - 10-11 SP - 952 EP - 956 PB - Wiley CY - Chichester AN - OPUS4-31604 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Streeck, C. A1 - Wirth, Thomas A1 - Unger, Wolfgang A1 - Beckhoff, B. T1 - Qualifying calibration samples for advanced thin film materials characterisation N2 - In this article the question of the certification of calibration samples for the characterisation of advanced thin film materials is addressed within the framework of reliable process control or quality management purposes. Reference measurement techniques can be used in order to address the gap in appropriate certified reference materials (CRMs) for thin film analyses. They allow for qualifying out-of-production samples originating from an operating production line as calibration samples. As a template for this procedure, CIGS [Cu(In,Ga)Se2] layers, that are absorber layers for high efficiency thin-film solar cells, have been used for establishing and validating reference-free X-ray fluorescence (XRF) analysis and Auger-electron spectroscopy (AES) as reference measurement techniques. The focus was on determining the average mole fractions in the CIGS layers obtaining results traceable to the SI unit system. Reference-free XRF is physically traceable and is based upon radiometrically calibrated instrumentation and knowledge of atomic fundamental data. Sputter-assisted AES can be established as a chemically traceable method after careful calibration using a certified reference material (CRM) based on a total number counting method. KW - CIGS KW - X-ray fluorescence (XRF) KW - Auger-electron spectroscopy (AES) PY - 2018 UR - https://www.spectroscopyeurope.com/article/qualifying-calibration-samples-advanced-thin-film-materials-characterisation VL - 30 IS - 1 SP - 11 EP - 14 PB - John Wiley & Sons Ltd CY - Chichester, West Sussex PO19 8SQ, UK AN - OPUS4-44260 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Unger, Wolfgang A1 - Senoner, Mathias A1 - Wirth, Thomas A1 - Bütefisch, S. A1 - Busch, I. T1 - Lateral resolution delivered by imaging surface-analytical instruments as SIMS, AES and XPS: Application of the BAM-L200 Certified Reference Material and related ISO Standards N2 - The certified reference material BAM-L200, a nanoscale stripe pattern for length calibration and specification of lateral resolution, is described. BAM-L200 is prepared from a cross-sectioned epitaxially grown layer stack of AlxGa1-xAs and InxGa1 xAs on a GaAs substrate. The surface of BAM-L200 provides a flat pattern with stripe widths ranging down to 1 nm. Calibration distances, grating periods and stripe widths have been certified by TEM with traceability to the length unit. The combination of gratings, isolated narrow stripes and sharp edges of wide stripes offers a plenty of options for the determination of lateral resolution, sharpness and calibration of length scale at selected settings of imaging surface analytical instruments. The feasibility of the reference material for an analysis of the lateral resolution is demonstrated in detail by evaluation of ToF-SIMS, AES and EDX images. Other applications developed in the community are summarized, too. BAM-L200 fully supports the implementation of the revised International Standard ISO 18516 (in preparation) which is based on knowledge outlined in the Technical Report ISO/TR 19319:2013. KW - Standardization KW - AES KW - XPS KW - SIMS KW - Lateral resolution KW - Certified reference material PY - 2017 SN - 1341-1756 VL - 24 IS - 2 SP - 123 EP - 128 AN - OPUS4-43138 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wirth, Thomas T1 - Investigation of Silica Nanoparticles by Auger Electron Spectroscopy (AES) T2 - PHI European User Meeting 2014 CY - Ismaning, Germany DA - 2014-05-14 PY - 2014 AN - OPUS4-32947 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dietrich, Paul A1 - Horlacher, T. A1 - Gross, Thomas A1 - Wirth, Thomas A1 - Castelli, R. A1 - Shard, A.G. A1 - Alexander, M. A1 - Seeberger, P. H. A1 - Unger, Wolfgang T1 - Surface analytical characterization of carbohydrate microarrays N2 - Microarrays are a versatile platform for diagnostics and high-throughput analysis. Carbohydrate microarrays are valuable tools to investigate interactions with other molecules since many glycans are involved in fundamental biological processes. A combined X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS) surface analysis was used to investigate the basic steps in the production of carbohydrate microarrays. The preparation included coupling of a thiol-terminated mannoside to maleimide-functionalized glass surfaces derived from γ-aminopropyl silane (GAPS) slides. XPS results clearly demonstrate successful chemical modification in each fabrication step, and ToF-SIMS imaging revealed immobilized carbohydrates in the spotted regions of the final microarray. KW - Carbohydrates KW - Microarrays KW - XPS KW - ToF-SIMS KW - Nona-mannoside KW - Maleimide surfaces KW - Surface analysis PY - 2010 DO - https://doi.org/10.1002/sia.3255 SN - 0142-2421 SN - 1096-9918 VL - 42 SP - 1188 EP - 1192 PB - Wiley CY - Chichester AN - OPUS4-21500 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Baytekin, H. Tarik A1 - Wirth, Thomas A1 - Gross, Thomas A1 - Sahre, Mario A1 - Unger, Wolfgang A1 - Theisen, J. A1 - Schmidt, M. T1 - Surface analytical characterization of micro-fluidic devices hot embossed in polymer wafers: Surface chemistry and wettability N2 - Recently, time-of-flight secondary ion mass spectrometry (ToF-SIMS) and X-ray photoelectron spectroscopy (XPS) instrumentation has been used to address areas of interest within micro-fluidic devices providing full access to the surface chemistry established at the bottom of micro-channels therein. After careful calibration, information on surface chemistry as obtained by ToF-SIMS or XPS can be interpreted in terms of wettability expressed as contact angles which are then characteristic for the inner walls of micro-channels. Standard contact angle measurement is not applicable in micro-channels. The approach has been demonstrated to be successful with two different micro-fluidic devices hot embossed into high-end quality poly(methyl methacrylate) (PMMA) or Polycarbonate wafers. A pre-selected surface chemistry at micro-channel walls can be established by plasma technologies but ageing and rinsing effects have to be under control. A combination of ToF-SIMS, XPS and contact angle measurement techniques has been demonstrated to provide the required information. Finally, it is shown by ToF-SIMS and XPS analysis that in the production of micro-fluidic parts during practical processing using hot embossing technologies, material originating from cover foils will reside on the polymer wafer's surface. Moreover, residues of releasing agents as silicone oil used during processing can be detected by ToF-SIMS. Both cover foil residues and silicones are issues of trouble shooting in micro-fluidics because they will change contact angles efficiently. KW - Micro-fluidic device KW - PMMA KW - Polycarbonate KW - Plasma treatment KW - Wettability KW - ToF-SIMS KW - XPS PY - 2010 DO - https://doi.org/10.1002/sia.3149 SN - 0142-2421 SN - 1096-9918 VL - 42 IS - 8 SP - 1417 EP - 1431 PB - Wiley CY - Chichester AN - OPUS4-21712 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Graf, Nora A1 - Yegen, E. A1 - Lippitz, Andreas A1 - Treu, Dieter A1 - Wirth, Thomas A1 - Unger, Wolfgang T1 - Optimization of cleaning and aminosilanization protocols for Si wafers to be used as platforms for biochip microarrays by surface analysis (XPS, ToF-SIMS and NEXAFS spectroscopy) N2 - It is known that aminosilanized Si wafers may be used as microarray platforms. Results of an XPS study of a cleaning applied to Si wafers prior to aminosilanization are presented and discussed. Furthermore, the results of an aminosilanization protocol optimized in terms of nitrogen chemistry are described. After optimization of the protocol a free amine content of 94% was reached. The surface chemistry was investigated in this study by using XPS, time of flight (ToF)-SIMS and near-edge X-ray absorption fine structure (NEXAFS) spectroscopy. Reference to aminosilanization protocols reported in the literature has been made. KW - Aminosilanization KW - Si wafers KW - Microarray KW - XPS KW - ToF-SIMS KW - NEXAFS PY - 2008 DO - https://doi.org/10.1002/sia.2621 SN - 0142-2421 SN - 1096-9918 VL - 40 IS - 3-4 SP - 180 EP - 183 PB - Wiley CY - Chichester AN - OPUS4-17192 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Baytekin, H.T. A1 - Wirth, Thomas A1 - Gross, Thomas A1 - Treu, Dieter A1 - Sahre, Mario A1 - Theisen, J. A1 - Schmidt, M. A1 - Unger, Wolfgang T1 - Determination of wettability of surface-modified hot-embossed polycarbonate wafers used in microfluidic device fabrication via XPS and ToF-SIMS N2 - The wettability of the surfaces inside the microchannels of a microfluidic device is an important property considering a liquid flows through them. Contact angle measurements usually applied to test the wettability of surfaces cannot be used for an analysis of microchannel walls within microfluidic devices. A workaround is the use of surface analytical methods, which are able to reach points of interest in microchannels and may provide information on the surface chemistry established there. In calibrating these methods by using flat polymer wafers, where the contact angle can be measured as usual, data measured in real microchannels can be evaluated in terms of wetting properties. Reference wafers of bisphenol-A polycarbonate, a polymeric material that is often used in fluidic microdevice fabrication, were treated under different oxygen plasma conditions. The modified surfaces were characterized by using XPS, time of flight (ToF)-SIMS and atomic force microscope (AFM). Surface chemistry and surface topography have been correlated with contact angle measurements. In addition, effects of ageing or rinsing after plasma treatment have also been investigated. KW - Oxygen plasma KW - Polycarbonate KW - XPS KW - ToF-SIMS KW - Principal component analysis PY - 2008 DO - https://doi.org/10.1002/sia.2724 SN - 0142-2421 SN - 1096-9918 VL - 40 IS - 3-4 SP - 358 EP - 363 PB - Wiley CY - Chichester AN - OPUS4-17340 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dietrich, Paul A1 - Horlacher, T. A1 - Girard-Lauriault, Pierre-Luc A1 - Gross, Thomas A1 - Lippitz, Andreas A1 - Min, Hyegeun A1 - Wirth, Thomas A1 - Castelli, R. A1 - Seeberger, P. H. A1 - Unger, Wolfgang T1 - Adlayers of dimannoside thiols on gold: surface chemical analysis N2 - Carbohydrate films on gold based on dimannoside thiols (DMT) were prepared, and a complementary surface chemical analysis was performed in detail by X-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectrometry (ToF-SIMS), near-edge X-ray absorption fine structure (NEXAFS), FT-IR, and contact angle measurements in order to verify formation of ω-carbohydrate-functionalized alkylthiol films. XPS (C 1s, O 1s, and S 2p) reveals information on carbohydrate specific alkoxy (C–O) and acetal moieties (O–C–O) as well as thiolate species attached to gold. Angle-resolved synchrotron XPS was used for chemical speciation at ultimate surface sensitivity. Angle-resolved XPS analysis suggests the presence of an excess top layer composed of unbound sulfur components combined with alkyl moieties. Further support for DMT attachment on Au is given by ToF-SIMS and FT-IR analysis. Carbon and oxygen K-edge NEXAFS spectra were interpreted by applying the building block model supported by comparison to data of 1-undecanethiol, poly(vinyl alcohol), and polyoxymethylene. No linear dichroism effect was observed in the angle-resolved C K-edge NEXAFS. KW - Carbohydrates KW - Self-assembled monolayer KW - XPS KW - NEXAFS KW - ToF-SIMS KW - Surface chemical analysis PY - 2011 DO - https://doi.org/10.1021/la104038q SN - 0743-7463 SN - 1520-5827 VL - 27 IS - 8 SP - 4808 EP - 4815 PB - American Chemical Society CY - Washington, DC AN - OPUS4-23554 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -