TY - CONF A1 - Rikowski, Eckhard A1 - Adam, Karin A1 - Torge, Manfred A1 - Wilke, Olaf A1 - Müller, W. T1 - Corrosion mechanisms and preventive conservation of baroque enamelled jewelleries T2 - Experts' Meeting on Enamel Conservation, Château de Germolles CY - Mellecey, France DA - 2006-07-01 PY - 2006 AN - OPUS4-13240 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Jann, Oliver A1 - Rockstroh, Jens A1 - Wilke, Olaf A1 - Noske, Reinhard A1 - Brödner, Doris A1 - Schneider, Uwe A1 - Horn, Wolfgang T1 - Development of a Test Method for and Investigation into Limiting the Emissions from Printers and Copiers within the Framework of Assigning the Environmental Label (Research Report 201 95 311/02 / UBA-FB 00,510E) N2 - Kurzfassung An neun verschiedenen Hardcopygeräten wurden in unterschiedlichen Emissionsmesskammern (zwei verschiedene 1 m³ - Kammern und eine 20 m³ - Kammer) in Kombination mit geeigneten Probenahme- und Analysenverfahren Untersuchungen zum Emissionsverhalten dieser Geräte hinsichtlich Staub, Ozon und VOC (TVOC) durchgeführt. Luftprobenahme und Analytik erfolgten für VOC mittels Tenax TA und anschließender Thermodesorption (TDS) in Verbindung mit GC / MS. Ozon wurde kontinuierlich bestimmt. Der Ozonanalysator arbeitete auf der Grundlage der flammenlosen Reaktion von Ozon mit Ethylen nach dem Prinzip der Chemilumineszenz. Die Staubbestimmung erfolgte gravimetrisch mittels Glasfaserfilter und Ultramikrowaage. Zusätzlich wurde die Partikelemission während des Druckbetriebes mit einem Partikelzähler bestimmt. Aufgrund der technischen Rahmenbedingungen standen nur kurze Druckzeiten von maximal 36 Minuten zur Verfügung. Um die Gleichgewichtskonzentration in der Prüfkammer zu erreichen, wurde die Luftaustauschrate in den 1 m³ - Kammern auf n = 4,0 bis 4,7 pro Stunde erhöht. Zusätzlich zur Prüfung in den Emissionsmesskammern sind verschiedene Papiere mittels Direkt - TDS sowie unter- schiedliche Toner mittels Headspaceprobenahme in Kombination mit GC / MS hinsichtlich ihres Emissionsverhaltens untersucht worden. Für die untersuchten Geräte wurden Emissionsraten ermittelt. Sie betrugen für TVOC 0,41 bis 22,4 mg pro Stück und Stunde, für Ozon kleiner 0,02 bis 4,6 mg pro Stück und Stunde sowie für Staub 0,10 bis 7,63 mg pro Stück und Stunde. Verglichen mit Frischfaserpapier wurden bei den Untersuchungen mit Recyclingpapier deutlich höhere SVOC - Konzentrationen nachgewiesen. Im Ergebnis der Untersuchungen wurde ein Prüfverfahren entwickelt, das die Basis für Emissionsmessungen im Rahmen der Umweltzeichen RAL –UZ 62, RAL –UZ 85 sowie des neuen RAL –UZ 114 für Multifunktionsgeräte darstellt. Abstract The emission behaviour with regard to dust, ozone and VOC (TVOC) of nine different hardcopy devices in combination with suitable air sampling and analysis procedures was investigated in different emission test chambers (two different 1 m³ - chambers and one 20 m³ - chamber). Air sampling and analysis for VOC were done by means of Tenax TA and subsequent thermal desorption (TDS) in connection with GC / MS. Ozone was determined continuously. The ozone analyser worked on the basis of the flame rid reaction of ozone with ethylene according to the principle of chemiluminescence. The dust determination was done gravimetrically by means of glass fibre filter and an ultra micro - balance. Additional the particle emission during the printing process was measured with a particle counter. The general technical conditions of the tested hardcopy devices were the reason for short printing times with a maximum of 36 minutes. In order to achieve the equilibrium concentration in the test chambers the air exchange rate in the 1 m³ - test chambers had to be increased to a value of n = 4,0 to 4,7 per hour. Additional to the examination of the hardcopy devices in the emission test chambers different papers were investi- gated by means of direct - TDS and different toners were tested by means of head space sampling in combination with GC / MS. For the examined hardcopy devices emission rates were determined. The emission rates for TVOC ranged from 0,41 to 22,4 mg per piece and hour, for ozone from less than 0,02 to 4,6 mg per piece and hour and for dust from 0,10 to 7,63 mg per piece and hour. The comparison between recycling paper and paper produced from primary fibres showed in general higher SVOC emissions from recycling paper. As the result of the investigations a test method for the determination of emissions from hardcopy devices was developed. This test method is the basis for emission tests in the framework of the German Award of the Environmental Label for office devices RAL -UZ 62, RAL -UZ 85 and the new RAL -UZ 114 for multifunctional devices. KW - Emissions KW - VOC KW - Ozone KW - Dust KW - Hardcopy device KW - Printers KW - Copiers KW - Emission test chamber KW - Environmental label PY - 2003 UR - http://www.umweltbundesamt.de/publikationen/development-of-a-test-method-for-an-investigation SN - 1862-4804 SN - 0722-186X IS - 88 SP - 1 EP - 159 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-7277 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Brödner, Doris T1 - Entwicklung eines Prüfverfahrens zur Ermittlung der Emission flüchtiger organischer Verbindungen aus beschichteten Holzwerkstoffen und Möbeln (Forschungsbericht 295 44 512/02 / UBA-FB 99-123) N2 - Beschichtete Holzwerkstoffe und daraus hergestellte Produkte, wie z.B. Möbel, sind in nahezu jedem Innenraum mit vergleichsweise großen Oberflächen anzutreffen. Vor dem Hintergrund einer Vielzahl von in Innenräumen verwendeten unterschiedlichen Materialien und Produkten und dem Ziel, die Belastung der Innenraumluft mit flüchtigen organischen Verbindungen möglichst gering zu halten, ist eine weitgehende Minimierung von Emissionen dieser Verbindungen aus den genannten möglichen Quellen notwendig. Zu diesem Zweck, auch im Hinblick auf die Umsetzung der „Konzeption der Bundesregierung zur Verbesserung der Luftqualität in Innenräumen“ wurde das bestehende deutsche Umweltzeichen RAL-UZ 38 (Blauer Engel) „Formaldehydarme Produkte aus Holz und Holzwerkstoffen“ überarbeitet. Für das Ziel einer Erweiterung von der Einzelverbindung Formaldehyd auf ein breites Spektrum an flüchtigen organischen Verbindungen war ein geeignetes Prüfverfahren als Basis der neuen Umweltzeichen-Vergabegrundlage zu entwickeln. Die Ergebnisse der hierfür durchgeführten Untersuchungen können dem Abschlußbericht entnommen werden. KW - Tenax KW - Thermodesorption KW - Emissionsmesszelle KW - Abklingverhalten KW - Alterung KW - Emissionsmesskammer KW - Emissionen KW - Flüchtige organische Verbindungen KW - Volatile organic compounds KW - Semi volatile organic compounds KW - Möbel KW - beschichtete Holzwerkstoffe PY - 1999 UR - http://www.umweltbundesamt.de/publikationen/entwicklung-eines-pruefverfahrens-zur-ermittlung SN - 1862-4804 SN - 0722-186X IS - 74 SP - 1 EP - 159 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-7202 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jann, Oliver A1 - Wilke, Olaf T1 - Comparison of FLEC with other climate chambers, Gemeran experiences T2 - 2nd International FLEC Symposium CY - Copenhagen, Denmark DA - 2001-09-06 PY - 2001 SP - 18 EP - 27 AN - OPUS4-7204 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Plehn, W. A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Brödner, Doris ED - Säteri, O. T1 - Eco-Label for low emission wood products and wood base products (RAL-UZ-38) - Part 1: Criteria and requirements for labeling T2 - Healthy Buildings 2000 Conference CY - Espoo, Finland DA - 2000-08-06 PY - 2000 SN - 952-5236-06-4 VL - 4 SP - 519 EP - 524 PB - SIY Indoor Air Information CY - Helsinki AN - OPUS4-7206 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rockstroh, Jens A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Horn, Wolfgang T1 - Development of a reliable test method for laser printers, copiers and multifunctional devices in emission test chambers - Part 1 N2 - Background to the studies was the revision of the current selection criteria of the German ecolabel Blauer Engel (“Blue angel“) for copiers and printers. In the requirements limits were set for ozone, dust and styrene emissions. The former test methods did no longer correspond to today’s requirements with regard to emission measurements. In addition, the emission behaviour of hardcopy devices due to the use of different and non-com parable test methods has been recently discussed controversely. For this reason a new test method had to be developed which enables a reliable, reproducible determination of emission rates (ER) for dust, ozone and VOC (volatile organic compounds). The basis for this was the ECMA-Standard 328 compiled by ECMA (European Computer Manufacturer Association) using dynamic chamber measurements. Nine different machines, desktop laser printers as well as office devices like bigger copiers and multifunctional devices were investigated. As a result of the study new criteria for the Blauer Engel for copiers, printers and a new created for multifunctional devices, concerning TVOC, ozone and dust emission were determined. Additionally a model is presented calculating the concentrations in real rooms under usual printing conditions derived from the test chamber results. PY - 2005 SN - 0949-8036 SN - 0039-0771 SN - 1436-4891 VL - 65 IS - 3 SP - 71 EP - 80 PB - Springer-VDI-Verl. CY - Düsseldorf AN - OPUS4-7210 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Brödner, Doris ED - Woods, J. ED - Grimsrud, D. ED - Boschi, N. T1 - Procedure for the determination and limitation of VOC-emissions from furnitures and coated wood based products T2 - Healthy Buildings/IAQ '97 ; ASHRAE Annual IAQ Conference ; 5th ISIAQ International Conference on Healthy Buildings CY - Bethesda, MD, USA DA - 1997-09-27 PY - 1997 SN - 0-929900-25-1 VL - 3 SP - 593 EP - 598 CY - Washington, DC AN - OPUS4-7237 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Einfluss unterschiedlicher Messmethoden auf die Summenkonzentration flüchtiger organischer Verbindungen T2 - 2. Workshop zum Forschungsvorhaben: Entwicklung eines Prüfverfahrens zur Ermittlung der Emission flüchtiger organischer Verbindungen aus beschichteten Holzwerkstoffen und Möbeln, BAM CY - Berlin, Germany DA - 1997-11-12 PY - 1997 AN - OPUS4-7254 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - VOC-Emissionen aus Verlegewerkstoffen, Bodenbelägen und Fußbodenaufbauten T2 - 18. TKB-Fachtagung "Klebstoffe in der Fußbodentechnik" CY - Frankfurt am Main, Germany DA - 2002-03-06 PY - 2002 AN - OPUS4-6007 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilke, Olaf A1 - Borzowski, F. A1 - Wiegner, Katharina A1 - Brauer, F. T1 - Bestimmung der VOC-Emissionen aus Grobspanplatten (OSB-Platten) und ihre Bewertung nach dem AgBB-Schema N2 - In den letzten Jahren ist der Markt für Grobspanplatten (engl.: Oriented Strand Boards, OSB) zum Einsatz beim Hausbau gewachsen. Die Platten werden in Deutschland und Europa hauptsächlich aus Kiefernholz hergestellt und finden Verwendung in Bodenbelägen, Decken und Wänden. Durch ihren Einsatz kann es zu gesundheitlichen Beschwerden, wie Geruchsbelästigungen oder Schleimhautreizungen, kommen. Die Bundesanstalt für Materialforschung und -prüfung (BAM) hat im Auftrag des Umweltbundesamtes (UBA) ein Forschungsvorhaben zu Emissionen aus Holz und Holzwerkstoffen durchgeführt. In Emissionsprüfkammern wurden unter anderem Proben von sechs OSB-Platten aus Baumärkten untersucht und ihre VOC-Emissionen (engl.: Volatile Organic Compounds, VOC) gemessen. Vier dieser Platten von drei verschiedenen Herstellern würden die Anforderungen des Ausschusses zur gesundheitlichen Bewertung von Bauprodukten (AgBB) nicht einhalten. Größtes Problem hierbei sind die ungesättigten Aldehyde. Der Einsatz von Antioxidantien während der Produktion kann helfen, ungewollte Emissionen deutlich zu reduzieren. KW - Holz KW - VOC-Emissionen KW - AgBB-Schema KW - OSB-Platten PY - 2013 SN - 2190-1120 SN - 2190-1147 VL - 1 SP - 5 EP - 11 PB - BfS CY - Berlin AN - OPUS4-28071 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Richter, Matthias A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Pyza, Lars A1 - Wilke, Olaf T1 - System to generate stable long-term VOC gas mixtures of concentrations in the ppb range for test and calibration purposes N2 - The development of a gas mixing system (GMS) that enables dynamic and retraceable production of stable long-term VOC gas mixtures within the ppb range is discussed. In this system pure liquid substances are kept separately at a constant temperature, evaporated according to their vapour pressure and removed by a small inert gas flow. A modular set-up allows flexible handling. All vapours generated are finally united in a mixing chamber. Any concentration level of the gas mixture can be produced by a suitable combination of evaporation temperature, carrier and dilution gas flows. Test results from continuous operation over six weeks are presented. The equipment was tested on seven volatile organic compounds (VOC) of different vapour pressure ranges. It was possible to establish stable operation for the equipment during the entire period and reproducible gas concentrations which were traceable to the mass as an SI unit, thus the system is suitable for long-term tests.--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Im Beitrag wird die Entwicklung eines Gasmischsystems (GMS) beschrieben, das die dynamische und rückführbare Generierung von langzeitstabilen VOC-Gasgemischen im ppb-Bereich erlaubt. Dabei werden Reinsubstanzen separat temperiert, ihrem Dampfdruck entsprechend verdampft und durch einen kleinen Inertgasstrom abgeführt. In einer Mischkammer werden sie schließlich zusammengeführt. Durch die Kombination von Verdampfungstemperatur, Träger- und Verdünnungsgasflüssen ist die Einstellung eines beliebigen Konzentrationsniveaus des Gasgemischs möglich. Aus einem Dauerbetrieb von sechs Wochen werden Untersuchungsergebnisse gezeigt. Dabei wurde die Apparatur mit insgesamt sieben flüchtigen organischen Verbindungen (VOC) unterschiedlicher Dampfdruckbereiche betrieben. Die Anlage lief über den gesamten Zeitraum stabil und lieferte reproduzierbare und auf die Masse als SI-Einheit rückführbare Gaskonzentrationen. Somit ist das Verfahren für Langzeitanwendungen geeignet. KW - Gas mixing system KW - VOC gas mixtures KW - Low gas concentrations KW - Evaporation KW - Dynamic gas generation PY - 2013 SN - 0949-8036 SN - 0039-0771 SN - 1436-4891 VL - 73 IS - 3 SP - 103 EP - 106 PB - Springer-VDI-Verl. CY - Düsseldorf AN - OPUS4-27903 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Richter, Matthias A1 - Brödner, Doris T1 - Emission study of furniture boards for the next version of the German eco label 'Blue Angel' for wood and wooden products (RAL-UZ 38) T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 2012-07-08 KW - Certification/labelling KW - Sources/emissions KW - VOC KW - Emission studies KW - Healthy homes and buildings PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 2 (1D.8) AN - OPUS4-27559 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Barthel, Mathias A1 - Seeger, Stefan A1 - Rothhardt, Monika A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Juritsch, Elevtheria A1 - Hahn, Oliver A1 - Jann, Oliver T1 - Erfassung der Zahl feiner und ultrafeiner Partikel aus Bürogeräten während der Druckphase zur Entwicklung eines Prüfverfahrens für das Umweltzeichen Blauer Engel für Bürogeräte mit Druckfunktion (UFOPLAN 370895301) KW - Bürogeräte mit Laserdruckfunktion KW - Feine und ultrafeine Partikel KW - Chemische Emissionen KW - Blauer Engel PY - 2013 UR - http://www.umweltbundesamt.de/publikationen/erfassung-zahl-feiner-ultrafeiner-partikel-aus SN - 1862-4804 SN - 0722-186X IS - 74 SP - 1 EP - 189 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-27523 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Kalus, Sabine A1 - Jann, Oliver T1 - Different possibilities for the statistical evaluation of round robin tests for volatile organic compounds in emission test chambers T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 2012-07-08 KW - Reference material KW - Round robin test KW - Emission test chamber KW - VOC-emission KW - Product emission testing PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 2 (8B.6) AN - OPUS4-27526 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris T1 - Höheres Emissionspotenzial bei Recyclingpapieren PY - 2004 SN - 0344-1733 SN - 1610-8256 VL - 28 SP - 54 EP - 56 PB - Vogel CY - Würzburg AN - OPUS4-5202 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Jann, Oliver A1 - Wilke, Olaf T1 - Sampling and analysis of wood preservatives in test chambers PY - 1999 SN - 3-527-29622-0 SP - 31 EP - 43 PB - Wiley-VCH CY - Weinheim AN - OPUS4-7200 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Rockstroh, Jens T1 - Ergebnisse der Emissionsmessungen an Druckern, Kopierern und Multifunktionsgeräten T2 - BITKOM Tagung CY - Frankfurt am Main, Germany DA - 2005-03-09 PY - 2005 AN - OPUS4-7186 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris T1 - Effects of temperature, humidity, air exchange rate, loading factor and storage-conditions on VOC-emissions from furniture boards coated with an UV-curable lacquer T2 - The 8th International Conference on Indoor Air Quality and Climate, Indoor Air '99 CY - Edinburgh, Scotland DA - 1999-08-08 PY - 1999 AN - OPUS4-7188 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris A1 - Rother, Ingrid T1 - Comparison of different types of emission test chambers and cells regarding VOC- and SVOC-emission T2 - 10th International Conference on Indoor Air Quality and Climate CY - Beijing, China DA - 2005-09-04 PY - 2005 AN - OPUS4-10928 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Torge, Manfred A1 - Brödner, Doris A1 - Wilke, Olaf T1 - Materialemissionen auf historischen Glasmalereien - Über den Einfluss so genannter organischer Verbindungen N2 - Historische Glasmalereien können durch anorganische und organische Luftverunreinigungen geschädigt werden. Chemische Reaktionen der empfindlichen Materialien eines Glasgemäldes (Glas, Malschicht, Blei) mit Luftfeuchtigkeit und den Schadstoffen der Umgebung führen zu Veränderungen der oberflächennahen Schichten des Glases, der Malschichten und schädigen die Bleie. Die Wirkung von Luftschadstoffen, die aus Industrieabgasen und Feuchtigkeit bestehen und als saurer Regen auf die Verglasung von Kirchen und Kathedralen einwirken ist weitgehend bekannt. Emissionen aus Materialien, die zur Verpackung, zum Transport und zur Lagerung von Kunstgegenständen aus Glas eingesetzt werden, können auch Schäden auf den empfindlichen Materialien verursachen. Als flüchtige organische Bestandteile (Volatile Organic Compounds VOC) wurden neben anderen auch organische Säuren analysiert. Das Schädigungspotenzial von Essigsäure, Propansäure, Hexansäure und Oktansäure wurde an Modellproben unter zeitraffenden Bedingungen im Klimaschrank untersucht. Nach einer Versuchsdauer von 12 Wochen waren die Oberflächen der empfindlichsten Modellproben bereits deutlich geschädigt. Hieraus ergibt sich die Schlussfolgerung, dass Materialien mit hohen Emissionsraten an organischen Säuren auch an mittelalterlichen Gläsern unter ungünstigen Bedingungen (geringe Luftwechsel in Depoträumen) Schäden verursachen können. KW - Glasmalerei KW - Verpackungsmaterialien KW - Emission PY - 2007 SN - 0933-4017 IS - 7 SP - 458 EP - 463 PB - Callwey CY - München AN - OPUS4-16090 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Schadstoffe in der Vitrinenluft? - Untersuchungen an Vitrinenmaterialien zum Schutz von Kunstwerken T2 - 2. N.i.Ke.-Workshop, BAM CY - Berlin, Germany DA - 2008-06-05 PY - 2008 AN - OPUS4-17617 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Kirchner, D. A1 - Jann, Oliver A1 - Kemmlein, S. A1 - Kalus, Sabine A1 - Süßmilch, C. T1 - European interlaboratory study for sampling VOC emissions - Step 1 - Liquid samples added on Tenax tubes T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate CY - Copenhagen, Denmark DA - 2008-08-17 KW - ISO 16000-6 KW - VOC analysis KW - Interlaboratory study KW - Emission tests KW - Building material PY - 2008 IS - Paper 226 SP - 1 AN - OPUS4-18048 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Brödner, Doris A1 - Juritsch, Elevtheria A1 - Süßmilch, C. A1 - Kirchner, D. T1 - European interlaboratory study for sampling VOC emissions - Step 2 - Sampling with Tenax tubes at an emission test chamber T2 - Indoor Air 2008, August 17-22, 2008 CY - Copenhagen, Denmark DA - 2008-08-17 KW - VOC KW - Tenax thermal desorption KW - Emission test chamber KW - Proficiency testing KW - Interlaboratory study PY - 2008 IS - Paper ID: 238 SP - 1 AN - OPUS4-17864 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Seeger, Stefan A1 - Bresch, Harald A1 - Brödner, Doris A1 - Juritsch, Elevtheria A1 - Jann, Oliver T1 - Sampling and characterisation of ultra fine particles released from laser printers T2 - Indoor Air 2008, August 17-22, 2008 CY - Copenhagen, Denmark DA - 2008-08-17 KW - Aerosol KW - Ultra fine particle KW - Laser printer KW - Cyclosiloxanes PY - 2008 IS - Paper ID: 239 SP - 1 AN - OPUS4-17865 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - VOC- und SVOC-Emissionen aus Fußbodenbelägen und Fußbodenaufbauten T2 - 11. WaBo-Lu-Innenraumtage, Umweltbundesamt (UBA) CY - Berlin, Germany DA - 2004-05-17 PY - 2004 AN - OPUS4-4915 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rockstroh, Jens A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Noske, Reinhard A1 - Brödner, Doris A1 - Kalus, Sabine A1 - Schneider, Uwe A1 - Krocker, Christian A1 - Horn, Wolfgang T1 - Emissionsbegrenzung aus Laserdruckern und Kopierern N2 - Vor dem Hintergrund der notwendigen Revision der Kriterien zur Vergabe des Gütezeichens "Blauer Engel" für Laserdrucker, Kopierer und Multifunktionsgeräte mussten auch die Prüfmethoden angepasst werden, da die alten Verfahren nicht mehr die heutigen Anforderungen der Emissionsmessung erfüllen. In diesem Zusammenhang wurde auch das unterschiedliche Emissionsverhalten von Hardcopy-Geräten auf Grund der verschiedenen und nicht miteinander vergleichbaren Prüfverfahren heftig diskutiert. Aus diesen Gründen wurde ein neues Prüfverfahren entwickelt, mit dem eine verlässliche und reproduzierbare Prüfung der Emissionsraten von Staub, Ozon und flüchtiger organischer Verbindungen auf der Basis des ECMA (European Computer Manufacturer Association) Standards 328 möglich ist. Dazu wurden neun verschiedene Geräte unter verschiedenen Bedingungen untersucht. Als ein Ergebnis dieser Studie wurden neue Kriterien zur Vergabe des "Blauen Engels" für Kopierer, Drucker und Multifunktionsgeräte festgelegt. PY - 2004 U6 - https://doi.org/10.3139/120.100606 SN - 0025-5300 VL - 46 IS - 9 SP - 465 EP - 471 PB - Carl Hanser Verlag CY - München AN - OPUS4-4120 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Untersuchung und Ermittlung emissionsarmer Klebstoffe T2 - 2. AgBB-Fachgespräch zur Vorgehensweise bei der gesundheitlichen Bewertung der Emissionen von flüchtigen organischen Verbindungen (VOC) aus Bauprodukten, DIBt CY - Berlin, Germany DA - 2004-11-25 PY - 2004 AN - OPUS4-4772 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris T1 - Fast and reliable determination of emissions from carpet adhesives PY - 2005 UR - http://www.gerstel.com/magazine_solution_05.htm SN - 1619-0076 IS - 5 SP - 4 EP - 5 CY - Mülheim an der Ruhr AN - OPUS4-7323 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Däumling, C. A1 - Brenske, K.-R. A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Health-related evaluation procedure of VOC and SVOC emissions from building products - a contribution to the European construction products directive KW - VOC KW - SVOC KW - Bauprodukte KW - AgBB KW - Bewertung PY - 2005 UR - http://www.technikwissen.de/gest/article.php?data[article_id]=7141 SN - 0949-8036 SN - 0039-0771 SN - 1436-4891 VL - 65 IS - 3 SP - 90 EP - 92 PB - Springer-VDI-Verl. CY - Düsseldorf AN - OPUS4-7364 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Rockstroh, Jens T1 - Testing the emission from printers by means of test chambers T2 - BAM-DIN-Workshop on Image Technology, BAM CY - Berlin, Germany DA - 2005-04-18 PY - 2005 AN - OPUS4-7360 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Teppich, Holzboden oder elastischer Bodenbelag? T2 - IBK-Symposium 330 - "Bauen, leben, wohnen - Gesundheit als Einheit" CY - Berlin, Deutschland DA - 2006-09-06 KW - Emissionen KW - Bodenbeläge KW - Blauer Engel KW - AgBB PY - 2006 SP - 8 Seiten PB - IBK CY - Darmstadt AN - OPUS4-13199 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Barthel, Mathias A1 - Seeger, Stefan A1 - Rothhardt, Monika A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Juritsch, Elevtheria A1 - Hahn, Oliver A1 - Jann, Oliver T1 - Measurement of fine and ultrafine particles from office devices during printing in order to develop a test method for the Blue Angel ecolabel for office-based printing devices KW - Bürogeräte KW - Laserdrucker KW - Partikelemissionen PY - 2013 UR - http://www.umweltbundesamt.de/publikationen/measurement-of-fine-ultrafine-particles-from-office SN - 1862-4804 VL - 75 IS - UBA-FBNr: 001743/E / FKZ: 3708 95 301 SP - 1-142, Suppl.RAL-UZ-122 1-39 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-28987 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Barthel, Mathias A1 - Seeger, Stefan A1 - Rothhardt, Monika A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Juritsch, Elevtheria A1 - Hahn, Oliver A1 - Jann, Oliver T1 - Erfassung der Zahl feiner und ultrafeiner Partikel aus Bürogeräten während der Druckphase zur Entwicklung eines Prüfverfahrens für das Umweltzeichen Blauer Engel für Bürogeräte mit Druckfunktion KW - Bürogeräte KW - Laserdrucker KW - Partikelemissionen PY - 2013 UR - http://www.umweltbundesamt.de/publikationen/erfassung-zahl-feiner-ultrafeiner-partikel-aus SN - 1862-4804 VL - 74 IS - FKZ/Projektnr. 3708 95 301 UBA-FBNr. 001743 SP - 1-146, Anh. 1-39 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-28988 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Analytische und sensorische Bewertung von Holz T2 - Abschlussveranstaltung zum UFOPLAN-Projekt "Sensorische Bewertung von Bauprodukten" CY - Berlin, Germany DA - 2010-03-08 PY - 2010 AN - OPUS4-21020 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Schulz, C. A1 - Richter, Matthias T1 - Test chamber measurements for the robustness validation of the test method for the determination of VOC-emissions for construction products into indoor air T2 - 10th International Conference Healthy Buildings 2012 CY - Brisbane, Australia DA - 2012-07-08 PY - 2012 AN - OPUS4-26948 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Matthias A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Use of emission test chambers for the determination of chemical emissions from construction materials T2 - 1st International conference on the chemistry of construction materials CY - Berlin, Germany DA - 2013-10-07 KW - VOC KW - Emission from materials KW - Construction materials KW - Emission test chamber PY - 2013 SN - 978-3-936028-75-1 N1 - Serientitel: GDCh-Monographien – Series title: GDCh-Monographien VL - 46 SP - 259 EP - 262 AN - OPUS4-29480 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pech, Anja A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Analysis of very volatile organic compounds (VVOC) with thermal desorption GC-MS N2 - Most VVOC were rarely considered in the evaluation of construction products. (Salthammer, 2014) In Germany this will change because the latest version of the German AgBB scheme for health evaluation (2015) now include VVOC, e.g. ethyl acetate and ethanol. In this study selected compounds were tested with the procedure described in ISO 16017 and a method for measuring VVOC with thermal desorption was developed. Three different adsorbents Tenax TA, Carbograph 5TD and Carbopack X were tested to analyse VVOC according to ISO 16017. For the tested VVOC, Carbograph 5TD showed the best results under the chosen analytical conditions. T2 - Indoor Air 2016, The 14th international conference of Indoor Air Quality and Climate CY - Gent, Belgium DA - 03.07.2016 KW - Thermal desorption KW - VVOC KW - Carbograph 5TD KW - Carbopack X PY - 2016 SP - Paper 889, 1 EP - 2 AN - OPUS4-37035 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Pech, Anja A1 - Mull, Birte A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Determination of Methanol and Ethanol in Test Chamber Air by using TDS-GC-FID T2 - Indoor Air Conference 2014 CY - Hong Kong, China DA - 2014-07-07 PY - 2014 AN - OPUS4-31341 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mull, Birte A1 - Wilke, Olaf T1 - Photocatalytical degradation of selected volatile organic compounds in emission test chambers N2 - This work focuses on the photocatalytical degradation of selected volatile organic compounds (toluene, butyl acetate, phenol and limonene) under UV-light and blue LED-light (λ = 444 nm) at different relative humidities. Ceramic tiles coated with titanium dioxide were used as photocatalytical active material. The experiments were performed in 20 l emission test chambers with two different kinds of pollutant supply. Toluene was the compound with the highest degradation rate in all performed experiments. A degradation rate of 24 % was obtained under blue LED-light and a relative humidity of (50 ± 5)% and a degradation rate up to 80 % was obtained under UV-light in dry air. T2 - Indoor Air 2014 - 13th International conference on indoor air quality and climate CY - Hongkong, China DA - 07.07.2014 KW - Photocatalysis KW - Titanium dioxide KW - Volatile organic compounds KW - Emission test chamber KW - UV-light PY - 2014 SP - HP0549, 1 EP - 5 AN - OPUS4-31364 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang T1 - ORGANIZATION AND EVALUATION OF PTS FOR THE DETERMINATION OF VOC-EMISSIONS FROM MATERIALS IN EMISSION TEST CHEMBERS T2 - 8th Eurachem Workshop on Proficiency Testing in Analytical Chemisty CY - Berlin, Germany DA - 2014-10-07 PY - 2014 AN - OPUS4-31712 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Wiegner, Katharina A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Till, Carola T1 - Interlaboratory study with Tenax thermal desorption - Phase 1 - liquid samples added onto tenax tubes T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - ISO 16000-6 KW - Interlaboratory study KW - VOC KW - External quality management system PY - 2009 IS - Paper 355 SP - 1 EP - 2 CY - Syracuse, NY, USA AN - OPUS4-19923 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris A1 - Scheffer, Harald A1 - Kalus, Sabine A1 - Till, Carola T1 - Study on VOC-Emissions from Oriented Strand Boards (OSB) T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - Volatile organic compound (VOC) KW - Aldehyde KW - Antioxidant KW - Wood KW - Oriented strand boards (OSB) PY - 2009 IS - Paper 247 SP - 1 EP - 4 CY - Syracuse, NY, USA AN - OPUS4-19928 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Till, Carola T1 - Interlaboratory study with Tenax thermal desorption - Phase 2- Tenax tubes spiked by BAM T2 - Healthy Buildings 2009 CY - Syracuse, NY, USA DA - 2009-09-15 PY - 2009 AN - OPUS4-20090 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Brödner, Doris A1 - Juritsch, Elevtheria A1 - Till, Carola A1 - Kirchner, D. T1 - European interlaboratory study for sampling VOC emissions - Step 3 - Emission test chamber measurements T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - VOC emission KW - Emission test chamber KW - Round robin test KW - Construction products KW - Tenax thermal desorption PY - 2009 IS - Paper 343 SP - 1 EP - 4 CY - Syracuse, NY, USA AN - OPUS4-20093 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Howard-Reed, C. A1 - Liu, Z. A1 - Cox, S. A1 - Little, J. A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Wiegner, Katharina A1 - Persily, A. T1 - Inter-laboratory study approach to validate the performance of a prototype reference material for product emissions testing N2 - Product emissions chamber testing involves a complex protocol with several sources of measurement uncertainty (ASTM, 2010; ISO, 2006). Despite the potential for significant variability in measurement results within and among laboratories, there is no Standard method available to assess the accuracy of emissions chamber test results. Recently, Germany’s Federal Institute for Materials Research and Testing (BAM) started a program to evaluate the performance of laboratories testing for the AgBB (German Committee for Health-related Evaluation of Building Products) labelling scheme (Wilke et al., 2009). Test method validation was conducted through interlaboratory studies (ILS) with over 30 participants. Simultaneously, the National Institute of Standards and Technology (NIST) and Virginia Tech (VT) started a program to develop a series of reference materials that mimic real building products, can be tested in typical emissions chambers, and have independently known emission rates (Cox et al., 2010). BAM, NIST and VT subsequently joined forces to conduct a series of inter-laboratory studies using the prototype reference material. A pilot ILS was conducted with BAM and NIST followed by an expanded ILS with several participating countries. Results from these interlaboratory studies have the potential to define an internationally-accepted Standard approach to validate results from product emissions tests. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Test method validation KW - Volatile organic compounds KW - Product certification PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23883 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang T1 - Ringversuche zur Überprüfung von Emissionskammermessungen T2 - 16. WaBoLu Innenraumtage CY - Berlin, Germany DA - 2009-05-18 PY - 2009 AN - OPUS4-19510 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Pech, Anja A1 - Mull, Birte A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Determination of methanol and ethanol in test chamber air by using TDS-GC-FID N2 - A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap 300 (R) (a multi-bed tube using Carbopack C (R), Carbopack B (R) and Carbosive SIII (R)) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber. T2 - Indoor Air 2014 - 13th International conference on indoor air quality and climate CY - Hong Kong, People's Republic of China DA - 07.07.2014 KW - Methanol KW - Ethanol KW - VVOC KW - Thermal desorption KW - Carbotrap 300 PY - 2014 SP - B6-HP0620, 1-2 AN - OPUS4-32323 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Even, Morgane A1 - Hutler, C. A1 - Wilke, Olaf A1 - Vieth, B. A1 - Luch, A. T1 - Investigations on emission properties of VOCs from consumer products made of polymers N2 - There is a need for an assessment of the emission properties of volatile organic compounds (VOCs) from consumer products. A method comparison was carried out to evaluate adapted and cost-effective procedures for such items. Smaller and automated emission chambers depicted similar kinetics compared to a 203 L standard chamber. Toy samples made of PVC (Polyvinyl chloride) emitted more VOCs compared to other tested polymeric products. The emissions from 2 selected samples were studied to allow an evaluation of the resulting room concentration and external exposure of a child. Obtained concentrations were not of concern. T2 - Indoor Air Conference 2018 CY - Philadelphia, USA DA - 22.07.2018 KW - Emission chamber KW - VOC KW - Consumer article PY - 2018 SP - Paper 381, 1 EP - 2 AN - OPUS4-45654 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Comparison of Formaldehyde Concentrations in Emission Test Chambers Using EN 717-1 and EN 16516 N2 - For many years EN 717-1 (Wood-based panels - Determination of formaldehyde release - Part 1: Formaldehyde emission by the chamber method) is the standard for formaldehyde emission testing of wooden boards. In 2017 EN 16516 (Construction products - Assessment of release of dangerous substances - Determination of emissions into indoor air) was published as a new harmonised standard for the emission testing of construction products. Because test chamber conditions are different, both standards give different concentrations for formaldehyde. For the determination of a conversion factor four test series were set up with different wooden boards. T2 - Conference on Indoor Air CY - Philadelphia, PA, USA DA - 22.07.2018 KW - Loading factor KW - Construction products KW - European standard KW - Air exchange rate PY - 2018 AN - OPUS4-45631 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Mull, B. A1 - Richter, Matthias A1 - Brödner, Doris A1 - Mölders, N. A1 - Renner, M. T1 - Reproducibly emitting reference material for quality assurance/quality control of emission test chamber measurements N2 - Volatile Organic Compounds (VOC) are ubiquitous in the indoor air, since they emit from materials used indoors. Investigations of these materials are mostly carried out in test chambers under controlled climatic conditions. Quality control of these test chamber measurements is important but there is a lack of commercially available homogenous reference materials as required for round robin tests or quality assurance of laboratories. The approach of the present study is the impregnation of a supporting material with VOC, which are reproducibly released in measurable chamber air concentrations under standardised test conditions. A polymer made of Thermoplastic Polyurethane (TPU) was chosen as carrier material. It was impregnated with the VOC trimethyl pentanediol isobutyrat (texanol). T2 - Healthy Buildings 2017 Europe CY - Lublin, Poland DA - 02.07.2017 KW - Emissions testing KW - Volatile organic compounds KW - Polymeric material KW - CO2 assisted impregnation PY - 2017 AN - OPUS4-42351 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Janine A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Emissions of formaldehyde and VOC from wood-based building products N2 - Wood-based materials are well-known sources for formaldehyde emission in the indoor environment. Different testing standards lead to different emission values for the materials. Such standards are compared in this study. Besides scenarios with varying loading factors, air exchange rates and climatic conditions were investigated to evaluate the formaldehyde emission potential of different building products. Under realistic indoor conditions used for the emission chamber tests, exceeding of formaldehyde indoor guide values were obtained. Results showed the need for improvement of wood-based materials with lower formaldehyde emissions and the adaption of testing parameters closer to realistic conditions. T2 - Healthy Buildings 2017 Europe CY - Lublin, Poland DA - 02.07.2017 KW - Formaldehyde KW - Emission chamber testing KW - Particle board KW - OSB PY - 2017 SN - 978-83-7947-232-1 SP - Paper 0175, 1-6 AN - OPUS4-41575 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Matthias A1 - Beck, Oliver A1 - Wilke, Olaf A1 - Pyza, Lars A1 - Seeger, Stefan T1 - Test procedure for the evaluation of adsorptive building materials T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 2012-07-08 KW - Air cleaning KW - Sorptive construction materials KW - Test procedure KW - Volatile organic compound KW - Test gas generation KW - Healthy homes and buildings KW - Material and construction KW - Product safety KW - Risk assessment PY - 2012 SN - 978-1-921897-40-5 SP - 43 EP - 44 (Session 4B) AN - OPUS4-27558 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Schulz, Christian A1 - Richter, Matthias T1 - Test chamber measurements for the robustness validation of the test method for the determination of VOC-emissions from construction products into indoor air T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 2012-07-08 KW - VOC KW - Emission studies KW - Product safety KW - Emission test chamber PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 2 (1D.2) AN - OPUS4-27560 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Richter, Matthias A1 - Brödner, Doris T1 - Emission study of furniture boards for the next version of the German eco label "Blue Angel" for wood and wooden products (RAL-UZ 38) T2 - 10th International Conference Healthy Buildings 2012 CY - Brisbane, Australia DA - 2012-07-08 PY - 2012 AN - OPUS4-26947 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pech, Anja A1 - Wilke, Olaf A1 - Mull, Birte A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Development of a TDS-GC-FID method for the determination of methanol and ethanol in air N2 - A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap300® (a multi-bed tube using Carbopack C®, Carbopack B® and Carbosive SIII®) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber N2 - Eine Methode zur Bestimmung von sehr leicht flüchtigen Verbindungen in Luft wurde für Methanol und Ethanol entwickelt und erfolgreich getestet. Dafür wurde Carbotrap300® (Multibettrohr aus Carbopack C®, Carbopack B® und Carbosive SIII®) als Sorptionsmedium für die Thermodesorption ausgewählt und dessen Eignung für Emissionskammermessungen untersucht. Das Adsorptionsverhalten und die chromatographischen Ergebnisse werden negativ durch die Aufgabe von wässrigen Kalibrierlösungen auf das Adsorptionsmedium beeinflusst. Durch das Überleiten von trockener Luft kann dieser Effekt verringert werden, da so das adsorbierte Wasser entfernt wird. Die Nachweis- und Bestimmungsgrenzen wurden für ein eingesetztes GC- FID-System ermittelt und mit einem GC-MS verglichen. Mit einem methanolabspaltenden silanmodifizierten Polymerklebstoff (SMP-Parkettkleber), der in eine Emissionskammer eingebracht wurde, konnte die Tauglichkeit der Methode überprüft werden. PY - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-297020 UR - http://www.gefahrstoffe.de/gest/article.php?data[article_id]=76019 SN - 0949-8036 SN - 0039-0771 SN - 1436-4891 VL - 73 IS - 11/12 SP - 477 EP - 482 PB - Springer-VDI-Verlag CY - Düsseldorf AN - OPUS4-29702 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilke, Olaf A1 - Wiegner, Katharina A1 - Scheffer, Harald A1 - Brödner, Doris A1 - Kalus, Sabine T1 - Determination of the emissions of volatile organic compounds from oriented strand boards and evaluation by the German AgBB scheme N2 - There has been an increasing use of oriented strand boards (OSBs) for the construction of floors, ceilings and walls of buildings. In Germany and other European countries, OSBs are mainly produced from pine wood (Pinus sylvestris). In response to complaints about the odour and irritation of mucous membranes in connection with the use of OSBs, samples of OSBs were bought from do-it-yourself stores to test their volatile organic compound (VOC) emissions by using emission test chambers. The boards emitted predominantly monoterpenes, aldehydes, acids and acetone. Aldehydes are generated during the production process by the oxidation of unsaturated fatty acids such as linoleic acid. Pine wood, compared with other wood species, contains more unsaturated fatty acids. Of the six acquired OSBs, four boards from three manufacturers would not meet the requirements of the German AgBB (Ausschuss zur gesundheitlichen Bewertung von Bauprodukten, Committee for Health Evaluation of Building Products), mainly because of the emissions of unsaturated aldehydes. These compounds have low LCI values (lowest concentration of interest) and are therefore problematic substances based on a health-related evaluation of building products according to the AgBB scheme. KW - Oriented strand board KW - Volatile organic compounds KW - Unsaturated aldehydes KW - Pine wood KW - Emission test chamber KW - AgBB scheme PY - 2014 U6 - https://doi.org/10.1177/1420326X13504121 SN - 1420-326X SN - 1423-0070 VL - 23 IS - 7 SP - 1050 EP - 1054 PB - Karger CY - Basel ; München [u.a.] AN - OPUS4-32063 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Seeger, Stefan T1 - New VOC compounds in the indoor environment from thermoplastic filaments for 3D printing N2 - A screening test for potential emissions of volatile organic compounds (VOC) was run on different thermoplastic filaments used for 3D printing. The method of direct thermal desorption was used to simulate the high temperatures during the 3D printing process and to identify the main compounds emitted from the filaments. A )arge number of unexpected compounds were detected that might affect the user's health and have an impact on indoor air chemistry. T2 - HB 2015 - 1st North American regional conference Healthy Buildings 2015 America CY - Boulder, Colorado, USA DA - 17.09.2015 KW - VOC KW - Emission KW - 3D printer PY - 2015 SP - 281 EP - 282 AN - OPUS4-34941 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Blue angel current and future criteria N2 - The lecture shows the history of the German Environmental Label RAL-UZ 205 for printers from 2003 until now. Information about the AgBB-scheme for the health-related evaluation of building products is given and ideas for the future improvement of the label are presented. T2 - JBMIA seminar CY - Tokio, Japan DA - 17.11.2017 KW - Blue Angel KW - Environmental label KW - Printer emission KW - AgBB PY - 2017 AN - OPUS4-43218 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Determination of emissions from materials and products into indoor air N2 - The lecture gives information about analytical methods for the determination of volatile organic compounds (VOC) and especially the equipment at BAM division 4.2. Examples are given for chamber test measurements and thermal extraction of materials. A special focus is put on chemical and particle emissions during 3-D-printing with thermoplastic filaments. T2 - JBMIA Meeting CY - Tokio, Japan DA - 17.11.2017 KW - Emissions KW - VOC KW - Test chamber KW - 3-D-printing PY - 2017 AN - OPUS4-43217 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Richter, Janine A1 - Jann, Oliver T1 - Emissions of formaldehyde and VOC from wood-based building products N2 - Wood-based materials are well-known sources for formaldehyde emission in the indoor environment. Different testing standards lead to different emission values for the materials. Such standards are compared in this study. Besides scenarios with varying loading factors, air exchange rates and climatic conditions were investigated to evaluate the formaldehyde emission potential of different building products. Under realistic indoor conditions used for the emission chamber tests, exceeding of formaldehyde indoor guide values were obtained. Results showed the need for improvement of wood-based materials with lower formaldehyde emissions and the adaption of testing parameters closer to realistic conditions. T2 - Healthy Buildings 2017 Europe CY - Lublin, Poland DA - 02.07.2017 KW - Formaldehyde KW - Emission chamber testing KW - Particle board KW - OSB PY - 2017 AN - OPUS4-41576 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Richter, Janine A1 - Jann, Oliver T1 - Emissions of formaldehyde from acoustic tiles N2 - Acoustics is an important aspect for large rooms especially in schools, kindergartens and offices. Foam tiles made from melamine resins are often used for acoustic insulation because they show good fire resistance and good thermal insulation properties. But they can emit formaldehyde. In Germany there are cases with a resulting indoor air concentration of higher than 100 µg/m³. In this study samples from two schools and one office were investigated. Additionally, new tiles were purchased and tested to evaluate the general potential as formaldehyde source. T2 - Healthy Buildings 2017 Europe CY - Lublin, Poland DA - 02.07.2017 KW - Building products KW - Emission test chamber KW - Formaldehyde KW - Foam tiles PY - 2017 AN - OPUS4-41573 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Janine A1 - Jann, Oliver A1 - Wilke, Olaf T1 - Emissions of formaldehyde from acoustic tiles N2 - Acoustics is an important aspect for large rooms especially in schools, kindergartens and offices. Foam tiles made from melamine resins are often used for acoustic insulation because they show good fire resistance and good thermal insulation properties. But they can emit formaldehyde. In Germany there are cases with a resulting indoor air concentration of higher than 100 µg/m³. In this study samples from two schools and one office were investigated. Additionally, new tiles were purchased and tested to evaluate the general potential as formaldehyde source. T2 - Healthy Buildings 2017 Europe CY - Lublin, Poland DA - 02.07.2014 KW - Building product KW - Emission test chamber KW - Formaldehyde KW - Foam tiles PY - 2017 SN - 978-83-7947-232-1 SP - Paper 0176, 1-2 AN - OPUS4-41574 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Die Bundesanstalt für Materialforschung N2 - Overview of BAM T2 - JBMIA Meeting CY - Tokio, Japan DA - 17.11.2017 KW - Focus area KW - Safety KW - Technology KW - Chemistry PY - 2017 AN - OPUS4-43215 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Wilke, Olaf A1 - Richter, Matthias A1 - Brödner, Doris T1 - Weiterentwicklung des Umweltzeichens Blauer Engel RAL-UZ 38 „Emissionsarme Produkte aus Holz und Holzwerkstoffen“ (UFOPLAN 3710 95 305 1) N2 - In diesem Projekt wurde das Prüfverfahren für die chemischen Emissionen zum RAL-UZ 38 überarbeitet. Dabei stand die Bewertung der Prüfkammermessungen mit Hilfe des AgBB-Schemas im Vordergrund. Dafür wurden die Prüfkammerbedingungen angepasst. Mit Hilfe einer Emissionsdatenbasis wurden Anforderungen an die Emissionen der Umweltzeichenprodukte abgeleitet. Die Datenbasis bildeten vorhandene Emissionsdaten der Umweltzeichenprodukte und Messungen aktueller Produkte. Dazu wurden 10 Prüfkammermessungen an unterschiedlichen Möbelplatten durchgeführt. In Zusammenarbeit mit den Lizenznehmern, dem RAL und dem Umweltbundesamt wurde ein neues Verfahren für die Auswahl der Prüfmuster für die Emissionsmessung erarbeitet. Dieses vereinigt eine repräsentative Auswahl mit einer regelmäßigen Nachprüfung einzelner Möbel und/oder Bauteile. Zudem wurden Kriterien für die Überprüfung der Anforderungen an die Herkunft des Holzes aufgestellt. Für Bodenbeläge, Paneele und Türen aus Holz und Holzwerkstoffen für Innenräume wurde eine neue Vergabegrundlage erschaffen (RAL-UZ 176). KW - Blauer Engel KW - Emissionsarme Materialien KW - Prüfverfahren KW - VOC-Emission PY - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-427472 SN - 1862-4359 VL - 2017/31 SP - 1 EP - 46 PB - Umweltbundesamt (UBA) AN - OPUS4-42747 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Seeger, Stefan A1 - Brödner, Doris A1 - Jacobi, T. A1 - Rasch, Fabian A1 - Rothhardt, Monika A1 - Wilke, Olaf T1 - Emissions of fine and ultrafine particles and volatile organic compounds from different filament materials operated on a low-cost 3D printer T1 - Emissionen feiner und ultrafeiner Partikel sowie flüchtiger organischer Verbindungen beim Einsatz verschiedener Filamentmaterialien in einem „low-cost“-3D-Drucker N2 - 3D-printing or additive manufacturing has many promising and unique advantages. Especially low cost molten polymer Deposition Printers are increasingly populär in the private and educational sector. Their environmental friendliness can be questioned due to recently reported ultrafine particle and suspected VOC emissions, To further investigate 3D-printing as a potential indoor air pollution source we characterized fine and ultrafine particle emissions from a molten polymer deposition printer producing a 3D object with ten marketable polymer filament materials under controlled conditions in a test chamber. VOC emissions from the filaments have also been compared. Using a straightforward emission model time dependent and averaged particle emission rates were determined. The results indicate that under comparable conditions some filament materials produce mainly ultrafine particles up to an average rate of 1013 per minute. This value is in the upper ränge of typical indoor ultrafine particle sources (e.g. Smoking, frying, candle light, laser printer). The observed material-specific rates differ by five Orders of magnitude. Filament-specific gaseous emissions of organic compounds such as bisphenol A, styrene and others were also detected. Our results suggest a detailed evaluation of related risks and considering protective measures such as housing and filtering. N2 - 3D-Druck oder additive Herstellungsverfahren haben eine Menge vielversprechender und einzigartiger Vorteile. Insbesondere günstige 3D-Drucker für Polymere werden im privaten und ausbildenden Bereich zunehmend beliebter. Ihre Umweltfreundlichkeit kann aufgrund jüngst berichteter Emissionen ultrafeiner Partikel und vermuteter VOC-Emissionen infrage gestellt werden. Um 3D-Drucker für Polymere als mögliche Quelle von Innenraumluftverunreinigungen weiter zu untersuchen, charakterisierten wir die Emissionen feiner und ultrafeiner Partikel bei der Herstellung eines 3D-Objekts unter Verwendung zehn marktgängiger Polymerfilamente unter kontrollierten Bedingungen in einer Emissionsprüfkammer. Die VOC-Emissionen der verschiedenen Filamente wurden ebenfalls verglichen. Die zeitabhängigen und gemittelten Partikelemissionsraten wurden durch Anwendung eines einfachen Emissionsmodells bestimmt. Die Ergebnisse zeigen, dass unter vergleichbaren Bedingungen einige Filamente mit einer mittleren Rate von 10 KW - Emission KW - Ultrafine particles KW - VOC KW - 3D printer PY - 2018 SN - 0949-8036 SN - 0039-0771 VL - 78 IS - 3 SP - 79 EP - 87 PB - Springer-VDI-Verl. CY - Düsseldorf AN - OPUS4-44954 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Mull, B. A1 - Richter, Matthias A1 - Brödner, Doris A1 - Mölders, N. A1 - Renner, M. T1 - Reproducibly emitting reference material for quality assurance/quality control of emission test chamber measurements N2 - Volatile Organic Compounds (VOC) are ubiquitous in the indoor air, since they emit from materials used indoors. Investigations of these materials are mostly carried out in test chambers under controlled climatic conditions. Quality control of these test chamber measurements is important but there is a lack of commercially available homogenous reference materials as required for round robin tests or quality assurance of laboratories. The approach of the present study is the impregnation of a supporting material with VOC, which are reproducibly released in measurable chamber air concentrations under standardised test conditions. A polymer made of Thermoplastic Polyurethane (TPU) was chosen as carrier material. It was impregnated with the VOC trimethyl pentanediol isobutyrat (texanol). T2 - Healthy Buildings 2017 Europe CY - Lublin, Poland DA - 02.07.2017 KW - Emissions testing KW - Volatile organic compounds KW - Polymeric material KW - CO2 assisted impregnation PY - 2017 SN - 978-83-7947-232-1 SP - Paper 0172, 1 EP - 2 AN - OPUS4-42348 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Horn, Wolfgang A1 - Richter, Matthias A1 - Nohr, M. A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Application of a novel reference material in an international round robin test on material emissions testing N2 - Emission testing of products is currently a rapidly increasing field of measurement activity. Labelling procedures for construction products are based on such emission test chamber measurements and hence measurement performance should be verified. A suited procedure for this purpose is the testing of one unique homogenous material in different laboratories within a Round Robin Test (RRT). Therefore, it is useful to have a reference material which can be used within inter-laboratory studies or as part of the quality management system to ensure comparable results. Several approaches on the development of reproducibly emitting materials have been published. These have in common only to emit a single VOC – toluene. Two further research studies carried out by BAM aimed to develop reference material for emissions testing containing one or more VOC in a single material. The first approach was a doped lacquer with Volatile and Semi-Volatile Organic Compounds (VOC/SVOC) and the second was Thermoplastic Polyurethane (TPU) or a Squalane/Paraffin mixture. Results received with the lacquer based material were presented in more detail. KW - Emission test chamber KW - Reference material KW - Round robin test KW - VOC PY - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-419412 SN - 1600-0668 SN - 0905-6947 VL - 28 IS - 1 SP - 181 EP - 187 PB - Wiley & Sons, Ltd. AN - OPUS4-41941 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Comparison of Formaldehyde Concentrations in Emission Test Chambers Using EN 717-1 and EN 16516 N2 - For more than 25 years EN 717-1 (Wood-based panels - Determination of formaldehyde re-lease - Part 1: Formaldehyde emission by the chamber method) is the standard for formalde-hyde emission testing of wooden boards. In 2017 EN 16516 (Construction products - Assess-ment of release of dangerous substances - Determination of emissions into indoor air) was published as a new harmonised standard for the emission testing of construction products. Because test chamber conditions are different, both standards give different concentrations for formaldehyde. To determine a conversion factor four test series were set up with different wooden boards. For a loading of 1 m²/m³ the conversion factor is 1.6. This means that the formaldehyde concentration measured under the conditions of EN 16516 is a factor of 1.6 higher compared to EN 717-1. T2 - Conference on Indoor Air CY - Philadelphia, PA, USA DA - 22.07.2018 KW - Loading factor KW - European standard KW - Construction products KW - Air exchange rate PY - 2018 SP - paper 627 AN - OPUS4-45630 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Even, Morgane A1 - Wilke, Olaf A1 - Kalus, Sabine A1 - Schultes, P. A1 - Hutzler, C. A1 - Luch, A. T1 - Formaldehyde emissions from wooden toys: Comparison of different measurement methods and assessment of exposure N2 - Formaldehyde is considered as carcinogenic and is emitted from particleboards and plywood used in toy manufacturing. Currently, the flask method is frequently used in Europe for market surveillance purposes to assess formaldehyde release from toys, but its concordance to Levels measured in emission test chambers is poor. Surveillance laboratories are unable to afford laborious and expensive emission chamber testing to comply with a new amendment of the European Toy Directive; they need an alternative method that can provide reliable results. Therefore, the application of miniaturised emission test chambers was tested. Comparisons between a 1 m3 emission test chamber and 44 mL microchambers with two particleboards over 28 days and between a 24 L desiccator chamber and the microchambers with three puzzle samples over 10 days resulted in a correlation coefficient r2 of 0.834 for formaldehyde at steady state. The correlation between the results obtained in microchambers vs. flask showed a high variability over 10 samples (r2: 0.145), thereby demonstrating the error-proneness of the flask method in comparison to methods carried out under ambient parameters. An exposure assessment was also performed for three toy puzzles: indoor formaldehyde concentrations caused by puzzles were not negligible (up to 8 µg/m3), especially when more conservative exposure scenarios were considered. KW - EN 717-3 KW - Formaldehyde KW - Wooden toys KW - Emission test chamber KW - Flask method KW - Microchamber PY - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-520196 VL - 14 IS - 2 (Special issue: Measurement of the environmental impact of materials) SP - 262-1 EP - 262-16 PB - MDPI AN - OPUS4-52019 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Richter, Matthias A1 - Jann, Oliver T1 - Volatile organic compounds from building products - Results from six round robin tests with emission test chambers conducted between 2008 and 2018 N2 - Emission testing of volatile organic compounds (VOC) from materials and products is commonly based on emission test chamber measurements. To ensure the comparability of results from different testing laboratories, their measurement performance must be verified. For this purpose, Bundesanstalt für Materialforschung und -prüfung (BAM) organizes an international proficiency test (round robin test, RRT) every two years using well-characterized test materials (one sealant, one furniture board, and four times a lacquer) with defined VOC emissions. The materials fulfilled the requirements of homogeneity, reproducibility, and stability. Altogether, 36 VOCs were included of which 33 gave test chamber air concentrations between 13 and 83 µg/m3. This is the typical concentration range to be expected and to be quantified when performing chamber tests. Three compounds had higher concentrations between 326 and 1105 µg/m3. In this paper, the relative standard deviations (RSD) of BAM round robin tests since 2008 are compared and the improvement of the comparability of the emission chamber testing is shown by the decrease of the mean RSD down to 28 % in 2018. In contrast, the first large European interlaboratory comparison in 1999 showed a mean RSD of 51 %. KW - Construction product KW - Emission test chamber KW - Interlaboratory comparison KW - Proficiency testing KW - Rround robin test KW - VOC emission PY - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-526139 VL - 31 IS - 6 SP - 2049 EP - 2057 PB - Wiley AN - OPUS4-52613 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Contaminants of Emerging Concern from Materials and Products: Measurement and Evaluation N2 - Test chamber measurements are an important tool to improve indoor air quality and occupational safety. Test chamber measurements are possible for a wide range of materials, products and technologies. Determination of concerning contaminants is important to ensure good indoor air quality. The detection of concerning contaminants depends on the approriate sampling and analysis. T2 - Webinar BAM-University of Birmingham CY - Online meeting DA - 24.02.2021 KW - Emerging Contaminants KW - Emission Test Chamber KW - Thermal Extraction KW - Thermal Desorption PY - 2021 AN - OPUS4-52262 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - de Krom, I. A1 - Heikens, D. A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Richter, Matthias A1 - Baldan, A. T1 - Metrological generation of SI-traceable gas-phase standards and reference materials for (semi-) volatile organic compounds N2 - EN 16516 sets specifications for the determination of emissions into indoor air from construction products. Reliable, accurate and International System of Unit (SI)-traceable measurement results of the emissions are the key to consumer protection. Such measurement results can be obtained by using metrologically traceable reference materials. Gas-phase standards of volatile organic compounds (VOCs) in air can be prepared by a variety of dynamic methods according to the ISO 6145 series. However, these methods are not always applicable for semi-VOCs (SVOCs) due to their high boiling point and low vapour pressure. Therefore, a novel dynamic gas mixture generation system has been developed. With this system gas-phase standards with trace level VOCs and SVOCs in air can be prepared between 10 nmol mol−1 and 1000 nmol mol−1. The VOCs and SVOCs in this study have normal boiling points ranging from 146 °C to 343 °C. Metrologically traceable reference materials of the gas-phase standard were obtained by sampling of the VOC gas-phase standard into Tenax TA® sorbent material in SilcoNert® coated stainless steel tubes. Accurately known masses between 10 ng and 1000 ng per VOC were sampled. These reference materials were used to validate the dynamic system. Furthermore, the storage and stability periods of the VOCs in the reference materials were determined as these are crucial characteristics to obtain accurate and SI-traceable reference materials. In a round robin test (RRT), the reference materials were used with the aim of demonstrating the feasibility of providing SI-traceable standard reference values for SVOCs for interlaboratory comparison purposes. Based on the results from the validation, the storage and stability studies and the RRT, gas-phase standards and reference materials of VOCs and SVOCs with relative expanded uncertainties between 5% and 12% (k = 2) have been developed. These reference standards can be used as calibrants, reference materials or quality control materials for the analysis of VOC emissions. KW - SVOC KW - Dynamic calibration gas mixtures KW - Reference materials KW - Indoor air KW - Thermal desorption PY - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-565978 VL - 34 IS - 3 SP - 1 EP - 13 PB - IOP Publishing AN - OPUS4-56597 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Klein, Luise A1 - Wilke, Olaf T1 - Chamber comparison for the determination of initial VOC emissions from consumer products N2 - Volatile organic compound (VOC) emissions from consumer products contribute to human inhalation exposure and may cause adverse health effects. Existing methods to determine long-term VOC emissions from e.g. building products need to be verified for their suitability to reliably detect initial VOC emissions from consumer products within the first hours and days of use, which would facilitate realistic inhalation exposure assessments. To investigate this issue, VOCs emitted from a test sample were determined in a large-scale emission test chamber and in two micro-chambers of different volumes, and the results were compared. T2 - Healthy Buildings 2023 Europe CY - Aachen, Germany DA - 11.06.2023 KW - Micro-chamber KW - Emission test chamber KW - Volatile organic compounds KW - Inhalation exposure KW - Consumer products PY - 2023 SP - 6 EP - 8 AN - OPUS4-58055 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Harmonised test standard EN 16516 - common approach for all building products for interiors N2 - The presentation gives general information about the European Standard EN 16516 “Construction products – Assessment of release of dangerous substances – Determination of emissions into indoor air”. This test standard was developed based on the mandate M/366 of the European commission and is a horizontal reference method for the determination of volatile organic compounds (VOC) from different classes of construction (building) products. Specific test conditions are to be selected by the product TCs (technical committees) in a way that a product is tested under its intended condition of use. The test is based on the use of emission test chambers which are operated at constant air change rate and climate (23°C, 50 % r.h.) over 28 days. The standard defines the conditions and requirements for the measurement including loading factor, air change rate, sampling, analysis and calculation of emission rates of the substances. A 30 m³ reference room is described which is used to calculate air concentrations from the determined emission rates. The standard EN 16516 enables the evaluation of construction products regarding their emissions into indoor air under defined and comparable conditions. The evaluation includes the determination of identified target compounds, non-identified target compounds, volatile carcinogenic compounds and the sum values TVOC, TSVOC and R. T2 - UBA Conference - Limiting health impacts of construction products regarding VOC CY - Online meeting DA - 20.04.2021 KW - Building products KW - EN 16516 KW - Emisson testing KW - Construction products PY - 2021 AN - OPUS4-58079 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Richter, Matthias A1 - Wilke, Olaf T1 - Volatile organic compounds from building products - Results from seven proficiency tests with emission test chambers conducted between 2008 and 2021 N2 - Emission testing of volatile organic compounds (VOC) from materials and products is commonly based on emission test chamber measurements. To ensure the comparability of results from different testing laboratories their measurement performance must be verified. For this purpose, Bundesanstalt für Materialforschung und -prüfung (BAM) organizes an international proficiency test every two years using well-characterised test materials (one sealant, one furniture board and four times a lacquer) with defined VOC emissions. The materials fulfilled the requirements of homogeneity, reproducibility, and stability. Altogether, 41 VOCs were included of which 37 gave test chamber air concentrations between 10 and 98 µg/m³. This is the typical concentration range to be expected and to be quantified when performing chamber tests. Four compounds had higher concentrations between 250 and 1105 µg/m³. The relative standard deviations (RSD) of BAM proficiency tests since 2008 are compared and the improvement of the comparability of the emission chamber testing is shown by the decrease of the mean RSD down to 23% in 2021. In contrast, the first large European interlaboratory comparison in 1999 showed a mean RSD of 51%. T2 - Proficiency Testing in Analytical Chemistry, Microbiology and Laboratory Medicine CY - Windsor, United Kingdom DA - 25.09.2023 KW - Proficiency Test KW - VOC-Emission KW - Chamber-test PY - 2023 AN - OPUS4-59694 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Richter, Matthias T1 - Round robin tests of odour and VOC emissions from building products – What have we learned so far? N2 - Emission testing of volatile organic compounds (VOC) and odour from materials and products is commonly based on emission test chamber measurements. These measurements are often the basis of mandatory or voluntary labelling procedures. To ensure the comparability of results from different testing laboratories their performance must be verified. For this purpose, round robin tests (RRTs) are conducted. Bundesanstalt für Materialforschung und - prüfung (BAM) offers such a RRT every two years using well characterised test materials with defined VOC emissions. In addition to the VOC quantification, the evaluation of odour is also implemented in the round robin tests. At the beginning, only perceived intensity (PI) was tested but over the years also the acceptance evaluation was considered. In principle, the results of PI and acceptance evaluation are comparable. The advantage of PI is the lower number of panel members necessary for one evaluation. T2 - Healthy Buildings 2023 Europe CY - Aachen, Germany DA - 11.06.2023 KW - Perceived intensity KW - VOC-emission KW - Poficiency test KW - Chamber test KW - Odour PY - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-580001 SP - 434 EP - 436 PB - ISIAQ (International Society of Indoor Air Quality and Climate) CY - Herndon, VA, USA AN - OPUS4-58000 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mull, Birte A1 - Wilke, Olaf T1 - Photocatalytic degradation of toluene, butyl acetate and limonene under UV and visible light N2 - Since Central Europeans spend most of their time indoors, the quality of the indoor air is important. Sources of volatile organic compounds (VOC) indoors are e. g. building materials, wall and floor coverings and interior equipment, whose emissions might influence the health and wellbeing of people. Photocatalysis is one opportunity to improve the indoor air quality by degrading VOCs ideally to carbon dioxide and water. Titanium dioxide (Ti02) in its anatase modification (band gap of 3.2 eV) is a common used UV-active photocatalytic coating. Because of the lack of UV light indoors Ti02 needs to be modified to be active under visible light too. This work focuses on the photocatalytic degradation of toluene, butyl acetate and limonene under UV LED light and blue LED light in emission test chambers under controlled climatic conditions. These compounds were selected due to their frequent occurrence in the indoor environment and their supply was done with a gas mixing System. Ceramic tiles coated with modified and pure Ti02 were used as photocatalytic active material. Previous results and experimental details were already published by Mull and Wilke (2014). T2 - Healthy Buildings Europe 2015 CY - Eindhoven, The Netherlands DA - 18.05.2015 KW - Titanium dioxide KW - Emission test chamber KW - Volatile organic compounds KW - Blue LED light PY - 2015 SN - 978-90-386-3889-8 SP - 1 EP - 4 AN - OPUS4-33410 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Seeger, Stefan T1 - VOC-Emissions from thermoplastic filaments for 3-D-printing N2 - Summary: A screening test for potential emissions of volatile organic compounds (VOC) was run on different thermoplastic filaments used for 3D printing. The method of direct thermal desorption was used to simulate the high temperatures during the 3D printing process and to identify the main compounds emitted from the filaments. A large number of unexpected compounds were detected that might affect the user’s health and have an impact on indoor air chemistry. Introduction: The use of desktop 3D printers is increasing. Compared to other devices with known emissions, e.g. laser printers, there is still a lack of information on possible emissions of VOC and ultrafine particles during operation and the effect on indoor air quality. Most of the commercially available desktop 3D printers operate with a molten polymer deposition. For this process a solid thermoplastic filament is heated in an extrusion nozzle. Most filaments for desktop 3D printers use either acrylonitrile butadiene styrene (ABS) or polylactic acid (PLA) as filament. Alternatives are polyvinyl alcohol (PVA) or polycarbonate (PC). Method: Eight different thermoplastic filaments for 3D printers were analysed by direct thermal desorption followed by GC-MS identification of the emitted substances. Direct thermal desorption was done by desorbing 5 mg of the feedstock for 1 minute at a temperature of 210°C. This is an average temperature for 3D printing with thermoplastic filaments. Results and conclusions: The comparison of the 4 different filament groups showed the highest overall emissions from ABS, followed by PLA, PC and PVA. Filament ABS 2 emitted mainly SVOCs and triphenyl phosphate, the latter has the highest emission for a single compound from all evaluated filaments. Thermoplastic filaments are a new source of VOC emissions due to the high temperatures associated with 3D printing, which can reach up to 270°C. Some of the detected compounds like lactic acid, lactide and bisphenol A have never been described before in the indoor environment. Additionally some of the main substances could not be identified and some others might have the potential to affect the indoor air chemistry. The appearance of some newly detected compounds raises concerns about potential health effects for the users of 3D printers at home. T2 - 20th Conference | Odour and Emissions of Plastic Materials CY - Kassel, Germany DA - 20.03.2018 KW - VOC KW - Emissions KW - 3D printing KW - Thermoplastic filaments PY - 2018 AN - OPUS4-44551 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Jann, Oliver A1 - Wilke, Olaf T1 - Emissionen aus Laserdruckern und -kopierern N2 - Drucker, Kopierer und Multifunktionsgeräte können zu einer Schadstoffbelastung der Innenraumluft beitragen. Insbesondere Staub, Ozon und flüchtige organische Verbindungen (VOC, Volatile Organic Compounds) werden beobachtet. Geräte mit besonders geringen Emissionen, die weitere umweltrelevante Anforderungen einhalten, können mit dem Umweltzeichen Blauer Engel ausgezeichnet werden. Die Vergabegrundlage für den Blauen Engel begrenzt neben den genannten Stoffen auch noch speziell die Emission von Benzol und Styrol, und sie enthält die Prüfvorschrift zur Bestimmung der Emissionen. In der vorliegenden Publikation werden Ergebnisse von Emissionsmessungen an 57 verschiedenen Geräten unterschiedlicher Hersteller aus den Jahren 2003 bis 2004 vorgestellt. Ein besonderer Schwerpunkt liegt hierbei neben der Darstellung der summarischen VOC-Emissionen (TVOC, Total Volatile Organic Compounds) auf den wichtigsten Einzel-VOC, wie z.B. Benzol, Styrol, Phenol, Xylole. Diese für Drucker und Kopierer typischen Verbindungen ließen sich mit Emissionsraten von bis zu einigen Milligramm pro Stunde feststellen. Zusätzlich traten auch Siloxane mit vergleichbaren Raten auf, die bisher als Emissionen aus Druckern und Kopierern nur wenig Beachtung fanden. In einigen Fällen waren hohe Emissionen an VOC, die sich einer ausreichenden Identifizierung entzogen, feststellbar. Aus den ermittelten Emissionsraten wurden für einen Modellraum mögliche resultierende Raumluftkonzentrationen berechnet. Diese Berechnungen setzen voraus, dass Emissionen nicht den gesamten Tag über erfolgen, sondern unter üblichen Nutzungsbedingungen über maximal 10% des Arbeitstages. Für Emissionen der druckbereiten Geräte hingegen wurde eine Belastung über den ganzen Tag zugrunde gelegt. Ergänzend werden Emissionsraten für Ozon und Staub vorgestellt. English: Hardcopy devices like printers, copiers and multifunctional devices contribute to indoor air pollution. Low emitting devices, that fulfil additional environment related requirements, can be labelled with the eco label "Blue Angel". It limits emissions of benzene, styrene, TVOC, dust and ozone. Results are given for 57 different devices investigated during the years 2003 and 2004. Additionally to TVOC, benzene and styrene further information is given for other emitted VOC like phenol and xylenes. These typical VOC showed emission rates up to some mg/ h but some more uncommon VOC like siloxanes were found in a comparable range, too. In some cases high emission rates were found for compounds which could not be identified. The measured emission rates were taken to calculate indoor air concentrations for a typical situation. For this purpose it was considered that printing is normally limited to less than 10 % of a working day whereas emissions from the stand by phase occur all day long. In addition emission rates for ozone and dust are presented. KW - Drucker KW - Emissionen KW - Kopierer KW - Ozon KW - Staub KW - VOC KW - Copiers KW - Dust KW - Emissions KW - Ozone KW - Printers PY - 2006 SN - 1430-8681 VL - 11 IS - 5 SP - 309 EP - 317 PB - Ecomed CY - Landsberg, Lech AN - OPUS4-13872 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mull, Birte A1 - Möhlmann, L. A1 - Wilke, Olaf T1 - Photocatalytic degradation of toluene, butyl acetate and limonene under UV and visible light with titanium dioxide-graphene oxide as photocatalyst N2 - Photocatalysis is a promising technique to reduce volatile organic compounds indoors. Titanium dioxide (TiO2) is a frequently-used UV active photocatalyst. Because of the lack of UV light indoors, TiO2 has to be modified to get its working range shifted into the visible light spectrum. In this study, the photocatalytic degradation of toluene, butyl acetate and limonene was investigated under UV LED light and blue LED light in emission test chambers with catalysts either made of pure TiO2 or TiO2 modified with graphene oxide (GO). TiO2 coated with different GO amounts (0.75%–14%) were investigated to find an optimum ratio for the photocatalytic degradation of VOC in real indoor air concentrations. Most experiments were performed at a relative humidity of 0% in 20 L emission test chambers. Experiments at 40% relative humidity were done in a 1 m³ emission test chamber to determine potential byproducts. Degradation under UV LED light could be achieved for all three compounds with almost all tested catalyst samples up to more than 95%. Limonene had the highest degradation of the three selected volatile organic compounds under blue LED light with all investigated catalyst samples. KW - Photocatalysis KW - Emission test chamber KW - Volatile organic compound KW - VOC KW - Degradation PY - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-402955 SN - 2076-3298 VL - 4 IS - 1 SP - Article 9, 1 EP - 9 PB - MDPI CY - Basel AN - OPUS4-40295 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Barthel, Mathias A1 - Seeger, Stefan A1 - Rothhardt, Monika A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Juritsch, Elevtheria A1 - Hahn, Oliver A1 - Jann, Oliver T1 - Erfassung der Zahl feiner und ultrafeiner Partikel aus Bürogeräten während der Druckphase zur Entwicklung eines Prüfverfahrens für das Umweltzeichen Blauer Engel für Bürogeräte mit Druckfunktion - Zusammenfassung N2 - Vor dem Hintergrund der anhaltenden öffentlichen Diskussion um mögliche gesundheitliche Risiken von Ultrafein- und Feinstaubemissionen aus Bürogeräten mit Laserdruckfunktion (LPD, Laser Printing Device) wurde vom Umweltbundesamt ein Forschungsvorhaben zur Entwicklung einer Prüfprozedur für die Quantifizierung der emittierten Partikel durch Zählung unter Standardbedingungen in Emissionsmesskammern, sowie zur physikalischen und chemischen Charakterisierung dieser Aerosole initiiert. Als Ergebnis konnte die Partikelzählung in den Entwurf des Prüfverfahrens für die Bestimmung von Emissionen (RAL-UZ-122, Anhang S-M) des Umweltzeichens "Blauer Engel" für Bürogeräte sowie in den Prüfstandards ECMA-328 und den Entwurf der ISO/IEC 28360 integriert werden. Die Methode wurde in einem internationalen Ringversuch erfolgreich getestet. Auf dieser Basis können Vergabekriterien und -werte für die Emission von Fein- und Ultrafeinpartikeln im Rahmen der Vergabe des Umweltzeichens Blauer Engel vereinbart und Produktprüfungen vorgenommen werden. KW - Blauer Engel KW - Bürogeräte mit Druckfunktion KW - Partikelemission KW - RAL-UZ 122 PY - 2011 VL - Förderkennzeichen UFOPLAN 3708 95 301 SP - 1 EP - 8 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-59863 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Wilke, Olaf T1 - Suitability of small environmental chambers to test the emission of biocides from treated materials into the air N2 - Biocides are used to protect materials that might be damaged by fungal, microbial or insect activity. The aim of this study is to develop a method for the measurement of these organic compounds, which generally have low or moderate vapor pressures. The biocides considered in this study are permethrin, dichlofluanid, tolylfluanid, iodpropinylbutylcarbamat, octylisothiazolinone, tebuconazole and propiconazole. The emission from two commercial products (plastic foil, wool carpet) containing biocides and of seven types of biocidal formulations applied to wood or clay tiles were investigated in 20-l glass emission test chambers. Each chamber test was performed over a period of 100–200 days, and one investigation was conducted over several years. Compared to volatile organic compounds, low-volatility compounds show totally different emission curves in chamber tests; maximal emission values may be reached in days or weeks. A period of 3 months is sometimes necessary for the determination of area-specific emission rates (SERa's). The SERa's (?g m-2 h-1) from biocide-containing products were determined for permethrin (0.006), propiconazole (0.3), dichlofluanid (2.0), tolylfluanid (1.0), octylisothiazolinone (2.5) and iodpropinylbutylcarbamat (2). In most cases, the SERa stayed at its maximum value or declined slowly over the test period. Additionally, a chamber test begun in 1994 with a piece of wood treated with a typical mixture of biocides dissolved in a technical solvent was continued. SERa's (?g m-2 h-1) for dichlofluanid (0.20), tebuconazole (0.49) and permethrin (0.08) remained detectable after the period of nearly 9 years during which the sample remained continuously in the chamber. This test proved the very slow decrease of emission of low-volatility compounds like permethrin and tebuconazole. KW - Indoor air KW - Biocides KW - Emission test chamber KW - SVOC PY - 2003 U6 - https://doi.org/10.1016/j.atmosenv.2003.09.024 SN - 0004-6981 SN - 1352-2310 VL - 37 IS - 39-40 SP - 5477 EP - 5483 PB - Elsevier CY - Amsterdam AN - OPUS4-2676 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Burbiel, M. A1 - Wilke, Olaf A1 - Kalus, Sabine ED - Levin, H. T1 - Biocide emissions from materials into indoor air N2 - The European biocides directive (98/8/EG) demand the control of emissions into the envi-ronment like soil, water and air. In this study a method for measuring the input of biocides into the indoor air from materials should be developed. The emission of two products containing biocides (plastic foil, wool carpet) and six different types of biocide containing formulations applied on wood or ceramic tiles were investigated in 20 or 23 l glass emission chambers. Each chamber test was performed over a period of 100 up to 200 days. SVOC show totally different emission curves in chamber tests compared to volatile organic com-pounds (VOC). They reach their maximum value after some days or weeks. Thus a period of 3 months is sometimes necessary for exact measurements. Area specific emission rates (SERa in µg/m²h) for permethrin (0.006), propiconazole (0.2), dichlofluanid (1.5), tolylfluanid (1.2), octylisothiazolinone (2.5) and for iodpropinylbutyl-carbamat (1.7) were determined. T2 - 9th International Conference on Indoor Air Quality and Climate CY - Monterey, CA, USA DA - 2002-06-30 KW - SVOC KW - Biocide KW - Chamber test KW - Polyurethane foam KW - Testing method PY - 2002 UR - http://www.irbnet.de/daten/iconda/CIB6909.pdf SN - 0-9721832-0-5 VL - 2 SP - 926 EP - 930 PB - International Academy of Indoor Air Sciences CY - Santa Cruz, Calif. AN - OPUS4-2000 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris ED - Levin, H. T1 - VOC- and SVOC-Emissions from Adhesives, Floor Coverings and Complete Floor Structures N2 - VOC/SVOC-Emissions from materials for flooring installation (primer, screed, adhesive, floor covering) were measured by means of emission test chambers and cells over a time period of at least 28 days at 23 C, 50 % relative humidity and an area specific air flow rate of q = 1.25 m³/m²h. Single components were tested in comparison to three complete structures (same concrete, primer, screed, adhesive) with different types of floor covering (PVC, carpet, linoleum). Sorption into concrete/screed and different sealing by the flooring materials affected the emissions from the complete structures. The complete structures with linoleum and PVC showed the same emissions and emission rates as the flooring materials alone. Emissions from the carpet-covered structure resulted mainly from the lower layers. For two adhesives the formation of secondary emissions (aldehydes and organic acids) was observed starting after the standard testing time of 28 days. T2 - 9th International Conference on Indoor Air Quality and Climate CY - Monterey, CA, USA DA - 2002-06-30 KW - Test chambers KW - VOCs and SVOCs KW - Secondary emissions KW - Construction and renovation PY - 2002 UR - https://www.irbnet.de/daten/iconda/CIB6472.pdf SN - 0-9721832-0-5 VL - 1 SP - 962 EP - 967 PB - International Academy of Indoor Air Sciences CY - Santa Cruz, Calif. AN - OPUS4-2002 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Jann, Oliver A1 - Wilke, Olaf T1 - Möglichkeiten und Grenzen bei der Bestimmung von SVOC-Emissionen aus Materialien und Produkten T2 - Messtechnisches Kolloquium CY - Schwäbisch Gmünd, Deutschland DA - 2002-06-11 PY - 2002 SN - 3-18-091656-7 SN - 0083-5560 N1 - Serientitel: VDI-Berichte – Series title: VDI-Berichte IS - 1656 SP - 357 EP - 367 PB - VDI-Verl. CY - Düsseldorf AN - OPUS4-2126 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris T1 - VOC- und SVOC-Emissionen aus Fußbodenaufbauten und den dafür verwendeten Materialien PY - 2003 SN - 0949-8036 SN - 0039-0771 SN - 1436-4891 VL - 63 IS - 3 SP - 92 EP - 98 PB - Springer-VDI-Verl. CY - Düsseldorf AN - OPUS4-2302 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilke, Olaf T1 - VOC-Emissionen aus Verlegewerkstoffen, Bodenbelägen und Fußbodenaufbauten PY - 2002 SN - 0939-4192 VL - 3 SP - 30 EP - 33 PB - Steinert CY - Hamburg AN - OPUS4-1814 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris T1 - Untersuchung und Ermittlung emissionsarmer Klebstoffe und Bodenbeläge N2 - Im vorliegenden Bericht wurden 11 Fußbodenbelagskleber, eine Grundierung, eine Spachtelmasse, 14 Teppiche, 5 PVC-Bodenbeläge, drei Linoleum-Beläge, ein Kautschukbelag und ein Polyolefinbelag über einen Zeitraum von mindestens 28 Tagen mittels Prüfkammer- bzw. Prüfzellenmessung auf ihr Emissionsverhalten untersucht. Die Emissionsmessungen an den Einzelmaterialien Kleber und Bodenbelag sollten die möglichen Emissionen (Substanzen und Konzentrationen) und deren zeitlichen Verlauf ermitteln. Außerdem wurden die Emissionen aus 7 Materialkombinationen ermittelt. Dazu gerhörten drei Komplettaufbauten aus Estrich, Grundierung, Spachtelmasse und Kleber mit den Belägen Teppich, PVC und Linoleum sowie 4 Verbundsysteme. Dies waren: Verbundsystem Estrich/Grundierung/Spachtelmasse/Kleber, Verbundsystem Glasplatte/Kleber/Teppich, Verbundsystem Glasplatte/Kleber/PVC-Belag und das Verbundsystem Estrich/Kleber. Die Emissionen aus den Komplettbauten wueden durch Sorptionseffekte und durch die unterschiedliche Durchlässigkeit der Bodenbeläge beeinflusst. Dabei waren die Emissionen aus den Komplettaufbauten und Verbundsystemen jeweils geringer als die Summe der Emissionen der entsprechenden Einzelmaterialien. Ergänzende Untersuchungen wurden durchgeführt zur Vergleichbarkeit der Emissionsmessungen in unterschiedlichen Prüfkammern (Volumen 1 m3 und 0,02 m3) bzw. Messzellen(Volumen 1 l und 0,035 l [FLEC]). und bei 42 Klebern zur Anwendbarkeit der Direkt-Thermodesorption (dynamische Headspace-Methode) als Screening-Verfahren. Des weiteren wurden Versuche durchgeführt, um die Auswirkungen unterschiedlicher Probenherstellung (Trägermaterial, Auftragsmenge, Auftragsart) auf die Emissionen aus den Fußbodenklebern abschhätzen können. Die durchgeführten Untersuchungen stellen eine Grundlage zur Erarbeitung eines Umweltzeichens für Fußbodenkleber dar. KW - Kleber KW - Fußbodenbelagskleber KW - Verlegewerkstoffe KW - Bodenbeläge KW - Emissionen KW - VOC KW - SVOC KW - Emissionsmesskammern KW - Emissionsmesszelle PY - 2003 UR - http://www.umweltbundesamt.de/publikationen/untersuchung-ermittlung-emissionsarmer-klebstoffe SN - 0722-186X IS - 27 SP - 1 EP - 144 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-2902 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Torge, Manfred A1 - Müller, Wolfgang A1 - Jann, Oliver A1 - Brödner, Doris A1 - Wilke, Olaf A1 - Pilz, M. T1 - Schadstoffbelastungen in Ausstellungsvitrinen und Simulation der Bedingungen im Labor T2 - 28. Jahrestagung der GUS CY - Pfinztal bei Karlsruhe, Deutschland DA - 1999-03-10 KW - Kulturguterhaltung KW - Umweltsimulation PY - 1999 SN - 3-9806167-3-8 SP - 16-1-16-14 CY - Pfinztal AN - OPUS4-3233 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris T1 - VOC and SVOC Contribution of Papers for Hardcopy Devices to Indoor Air Pollution T2 - 7th International Conference Healthy Buildings 2003: Energy-Efficient Healthy Buildings CY - Singapore DA - 2003-12-07 PY - 2003 AN - OPUS4-3242 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris T1 - Emissionsmessungen an Materialien für Fußbodenaufbauten T2 - VDI-Kolloquium "Luftverunreinigungen im Innenraum" CY - Düsseldorf, Germany DA - 2003-11-03 PY - 2003 AN - OPUS4-3241 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilke, Olaf T1 - Luftverpestern auf der Spur - Forschungsergebnisse VOC-Emissionen aus Verlegewerkstoffen, Bodenbelägen und Fußbodenaufbauten PY - 2003 SN - 0006-5463 VL - 49 IS - 1 SP - 69 EP - 71 PB - Holzmann CY - Bad Wörishofen AN - OPUS4-3232 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - VOC-Emissionen aus Verlegewerkstoffen, Bodenbelägen und Fußbodenaufbauten T2 - 18. TKB-Fachtagung CY - Frankfurt am Main, Deutschland DA - 2002-03-06 PY - 2002 PB - SN-Verl. CY - Hamburg AN - OPUS4-3274 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Rockstroh, Jens A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Noske, Reinhard A1 - Brödner, Doris A1 - Schneider, Uwe A1 - Horn, Wolfgang ED - Wai, T. K. ED - Sekhar, C. ED - Cheong, D. T1 - Investigations on VOC, ozone and dust emissions from hardcopy devices (laser printers, copiers and multifunctional devices) in test chambers - development of a test method T2 - 7th Healthy Buildings Conference ; HB 2003 ; ISIAQ international conference CY - Singapore, Republic of Singapore DA - 2003-12-07 KW - Emissions KW - Printers KW - Copiers KW - VOC KW - Dust KW - Ozone KW - Blue Angel PY - 2003 SN - 981-049974-4 VL - 1 SP - 397 EP - 403 CY - Singapore AN - OPUS4-3315 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris ED - Wai, T. K. ED - Sekhar, C. ED - Cheong, D. T1 - VOC and SVOC Contribution of Papers for Hardcopy Devices to Indoor Air Pollution T2 - 7th Healthy Buildings Conference ; HB 2003 ; ISIAQ international conference CY - Singapore, Republic of Singapore DA - 2003-12-07 PY - 2003 SN - 981-049974-4 VL - 1 SP - 289 EP - 295 CY - Singapore AN - OPUS4-3377 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris T1 - VOC and SVOC Contribution of Papers for Hardcopy Devices to Ondoor Air Pollution T2 - Healthy Buildings 2003 - 7th International Conference CY - Singapore DA - 2003-12-07 PY - 2003 AN - OPUS4-5437 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Untersuchung der Korrelation zwischen Emissionen flüchtiger organischer Stoffe nach dem Prüfkammerverfahren und dem Thermodesorptionsverfahren T2 - Anhörung zum Umweltzeichen RAL UZ 14 "Blauer Engel" für Recyclingpapiere, UBA (Umweltbundesamt) CY - Berlin, Germany DA - 2004-11-02 PY - 2004 AN - OPUS4-4777 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris T1 - Emissionsmessungen an Materialien für Fußbodenaufbauten T2 - Kolloquium Luftverunreinigungen im Innenraum CY - Düsseldorf, Deutschland DA - 2003-11-03 PY - 2003 SN - 3-18-091778-4 SN - 0083-5560 N1 - Serientitel: VDI-Berichte – Series title: VDI-Berichte IS - 1778 SP - 71 EP - 82 PB - VDI-Verl. CY - Düsseldorf AN - OPUS4-3378 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Test Chamber Measurements on Different Building Products (Materials) with Regard to Emissions of VOCs, Biocides and Flame Retardants T2 - CERTECH-Conference "Emissions and Odours from Materials" CY - Brussels, Belgium DA - 2003-11-19 PY - 2003 AN - OPUS4-5423 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hahn, Oliver A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Luftschadstoffe in Archiven und Museen - Wie können Kunstwerke vor einer übermäßigen Belastung geschützt werden? KW - Luftschadstoffe KW - VOC KW - Emissionsmessungen KW - Schutz vor Kunst- und Kulturgut PY - 2004 SN - 0933-4017 VL - 110 IS - 6 SP - 406 EP - 410 PB - Callwey CY - München AN - OPUS4-4116 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gehr, V. A1 - Jann, Oliver A1 - Söffge, M. A1 - Wilke, Olaf T1 - Emissionen von flüchtigen organischen Verbindungen aus Recyclingpapieren und ihre Relevanz für die Innenraumluftqualität PY - 2004 SN - 0043-7131 VL - 132 IS - 17 SP - 1010 EP - 1014 PB - Dt. Fachverl. CY - Frankfurt, M. AN - OPUS4-5205 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Brödner, Doris A1 - Plehn, W. ED - Säteri, O. T1 - Eco-Label for low emission wood products and wood base products (RAL-UZ-38) - Part 2: Test procedure and results T2 - Healthy Buildings 2000 Conference CY - Espoo, Finland DA - 2000-08-06 PY - 2000 SN - 952-5236-06-4 VL - 4 SP - 525 EP - 530 PB - SIY Indoor Air Information CY - Helsinki AN - OPUS4-7205 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris ED - Säteri, O. T1 - Investigations on the emission behavior of low-emitting adhesives for flooring materials T2 - Healthy Buildings 2000 Conference CY - Espoo, Finland DA - 2000-08-06 PY - 2000 SN - 952-5236-06-4 VL - 4 SP - 391 EP - 396 PB - SIY Indoor Air Information CY - Helsinki AN - OPUS4-7207 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Probenahme und Analytik der Innenraumluftschadstoffe T2 - Informationsseminar für die RKW-Landesgruppe Brandenburg/Potsdam zum Thema Umwelttechnik: Baustoffverwendung und Entsorgung CY - Berlin, Germany DA - 1996-03-28 PY - 1996 AN - OPUS4-7255 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Emissionsmessungen an strahlenhärtenden Lacksystemen T2 - 8. UCB Radcure-Symposium CY - Dresden, Deutschland DA - 1997-09-11 PY - 1997 AN - OPUS4-7238 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Brödner, Doris A1 - Schneider, Uwe A1 - Marten, Silvia T1 - Die Umgebungsluft von Exponaten PY - 2000 SN - 0933-4017 VL - 106 IS - 6 SP - 428 EP - 432 PB - Callwey CY - München AN - OPUS4-7203 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Plehn, W. T1 - Anforderungen an emissionsarme Möbel PY - 1996 SN - 0018-3792 VL - 122 IS - 6 SP - 65 EP - 67 PB - DRW-Verl. Weinbrenner CY - Leinfelden-Echterdingen AN - OPUS4-7236 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Jann, Oliver A1 - Rockstroh, Jens A1 - Wilke, Olaf A1 - Noske, Reinhard A1 - Brödner, Doris A1 - Schneider, Uwe A1 - Horn, Wolfgang T1 - Entwicklung einer Prüfmethode und Untersuchungen zur Begrenzung von Emissionen aus Druckern und Kopiergeräten im Rahmen der Umweltzeichenvergabe (Forschungsbericht 201 95 311/02 / UBA-FB 000510) N2 - An neun verschiedenen Hardcopygeräten wurden in unterschiedlichen Emissionsmesskammern (zwei verschiedene 1 m³ - Kammern und eine 20 m³ - Kammer) in Kombination mit geeigneten Probenahme- und Analysenverfahren Untersuchungen zum Emissionsverhalten dieser Geräte hinsichtlich Staub, Ozon und VOC (TVOC) durchgeführt. Luftprobenahme und Analytik erfolgten für VOC mittels Tenax TA und anschließender Thermodesorption (TDS) in Verbindung mit GC / MS. Ozon wurde kontinuierlich bestimmt. Der Ozonanalysator arbeitete auf der Grundlage der flammenlosen Reaktion von Ozon mit Ethylen nach dem Prinzip der Chemilumineszenz. Die Staubbestimmung erfolgte gravimetrisch mittels Glasfaserfilter und Ultramikrowaage. Zusätzlich wurde die Partikelemission während des Druckbetriebes mit einem Partikelzähler bestimmt. Aufgrund der technischen Rahmenbedingungen standen nur kurze Druckzeiten von maximal 36 Minuten zur Verfügung. Um die Gleichgewichtskonzentration in der Prüfkammer zu erreichen, wurde die Luftaustauschrate in den 1 m³ - Kammern auf n = 4,0 bis 4,7 pro Stunde erhöht. Zusätzlich zur Prüfung in den Emissionsmesskammern sind verschiedene Papiere mittels Direkt - TDS sowie unterschiedliche Toner mittels Headspaceprobenahme in Kombination mit GC / MS hinsichtlich ihres Emissionsverhaltens untersucht worden. Für die untersuchten Geräte wurden Emissionsraten ermittelt. Sie betrugen für TVOC 0,41 bis 22,4 mg pro Stück und Stunde, für Ozon kleiner 0,02 bis 4,6 mg pro Stück und Stunde sowie für Staub 0,10 bis 7,63 mg pro Stück und Stunde. Verglichen mit Frischfaserpapier wurden bei den Untersuchungen mit Recyclingpapier deutlich höhere SVOC - Konzentrationen nachgewiesen. Im Ergebnis der Untersuchungen wurde ein Prüfverfahren entwickelt, das die Basis für Emissionsmessungen im Rahmen der Umweltzeichen RAL –UZ 62, RAL –UZ 85 sowie des neuen RAL –UZ 114 für Multifunktionsgeräte darstellt. KW - Emissionen KW - VOC KW - Ozon KW - Staub KW - Hardcopygerät KW - Drucker KW - Kopierer KW - Emissionsmesskammer KW - Umweltzeichen PY - 2003 UR - http://www.umweltbundesamt.de/publikationen/entwicklung-einer-pruefmethode-untersuchungen-zur SN - 1862-4804 SN - 0722-186X IS - 71 SP - 1 EP - 159 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-7276 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris T1 - Direct thermal extraction as screening method for testing materials with regard to VOC- and SVOC-emissions under environmental aspects T2 - PITTCON 2004 CY - Chicago, IL, USA DA - 2004-03-07 PY - 2004 AN - OPUS4-4916 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris T1 - Direkte thermische Extraktion versus Prüfkammer - Emissionsverhalten von Teppichklebstoffen sicher bestimmen PY - 2004 UR - http://www.gerstel.de/pdf/GERSTEL_Aktuell_32_4-5_de.pdf IS - 32 SP - 4 EP - 5 CY - Mülheim an der Ruhr AN - OPUS4-3498 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris T1 - VOC- and SVOC-Emissions from Adhesives, Floor Coverings and Complete Floor Structures T2 - Indoor Air 2002 CY - Monterey, CA, USA DA - 2002-06-03 PY - 2002 AN - OPUS4-6042 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Bestimmungen von Weichmacheremissionen aus unterschiedlichen Materialien in Emissionsmeßkammern T2 - 4. Freiberger Polymertag CY - Freiberg, Germany DA - 1999-05-27 PY - 1999 AN - OPUS4-7187 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Spurensuche in der Museumsluft - Einsatz der Gaschromatographie zum Schutz von Kunstwerken T2 - Chemie der Kunst, BAM CY - Berlin, Germany DA - 2003-11-21 PY - 2003 AN - OPUS4-5424 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Walther, Wolfgang A1 - Ulrich, D. T1 - Entwicklung eines standardisierbaren Prüfverfahrens zur Bestimmung des Eintrages von Holzschutzmittel-Wirkstoffen aus behandeltem Holz, Altholz und daraus hergestellten Holzwerkstoffen in die Luft (Forschungsbericht 226 06 003 / UBA-FB 99-077) N2 - Das entwickelte Pruefverfahren zum Nachweis der Emission von Holzschutzmittelwirkstoffen in die Luft basiert auf einer Emissionsmesskammer in Kombination mit einem geeigneten Probenahme- und Analysenverfahren. Unter Beruecksichtigung der insbesondere bei schwererfluechtigen Holzschutzmittelwirkstoffen auftretenden Senken- bzw. Wandeffekte hat sich eine Emissionsmesskammer auf der Basis eines 20 I-Exsikkators unter den gewaehlten Randbedingungen als besonders geeignet erwiesen. Fuer die Probenahme (Adsorption) eines breiten Spektrums an untersuchten Wirkstoffen (Pentachlorphenol, Lindan, Furmecyclox, Dichlofluanid, Propiconazol, Tebuconazol, Permethrin, Deltamethrin) laesst sich spezieller Polyurethanschaum vorteilhaft einsetzen. Unterschiedliche Desorptionsverfahren (Soxhletextraktion, superkritische Fluessigextraktion (SFE), Elution) haben sich als geeignet erwiesen. Insbesondere die Elution mit Aceton als Loesemittel ist unter dem Aspekt von Zeit- und Geraeteaufwand besonders empfehlenswert. Fuer die Analytik kam insbesondere die Kapillar-Gaschromatographie mit unterschiedlichen Detektoren (FID, NPD, ECD, MSD, AED) zur Anwendung. Beim Einsatz der Kapillar-Gaschromatographie laesst sich prinzipiell halbquantitativ auch die Probenahme auf anderen Adsorbentien (Tenax oder Glaswolle) in Kombination mit einer nachfolgenden Thermodesorption einsetzen. Bei Verwendung von Tenax in Kombination mit nachfolgender Thermodesorption ist auch der quantitative Nachweis einiger leichter fluechtiger Wirkstoffe (Lindan, Furmecyclox, Dichlofluanid) und auch anderer Holzschutzmittel-Inhaltsstoffe, wie Loesemittel und Weichmacher, moeglich. Mit dem eingesetzten Verfahren laesst sich die Emission der Wirkstoffe Lindan, Furmecyclox, Dichlofluanid, Propiconazol, Tebuconazol, Permethrin und mit Einschraenkung Deltamethrin, sowie Pentachlorphenol nachweisen. Auch fuer andere biozide Wirkstoffe in einem vergleichbaren Fluechtigkeitsbereich, sowie fuer andere Materialien als Holz und Holzwerkstoffe, ist eine Eignung anzunehmen, im Einzelfall jedoch naeher zu untersuchen. PY - 1999 SN - 1862-4804 SN - 0722-186X IS - 51 SP - 1 EP - 211 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-7201 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris T1 - VOC- and SVOC-Emissions from Adhesives, Floor Coverings and Complete Floor Structures N2 - Emissions of volatile organic compounds (VOC) and semivolatile organic compounds (SVOC) from materials for flooring installation (primer, screed, adhesive, floor covering) were measured by means of emission test chambers and cells over a time period of at least 28 days at 23 °C, 50% relative humidity and an area specific air flow rate of q = 1.25 m3/m2 h. Single components were tested in comparison to three complete structures (same concrete, primer, screed, adhesive) with different types of floor covering (PVC, carpet, linoleum). Sorption into concrete/screed and different permeability of flooring materials affected the emissions from the complete structures. The complete structures with linoleum and PVC showed the same types of emission and emission rates as the individual floor coverings themselves. Emissions from the carpet-covered structure resulted also from the lower layers. In all cases emissions from the complete structures were lower than the sum of emissions from the single components. For two adhesives the formation of secondary emissions (aldehydes and organic acids) was observed starting after the standard testing time of 28 days. PY - 2004 U6 - https://doi.org/10.1111/j.1600-0668.2004.00314.x SN - 0905-6947 SN - 1600-0668 VL - 14 IS - Suppl. 8 SP - 96 EP - 105 PB - Danish Techn. Pr. CY - Copenhagen AN - OPUS4-5048 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Emissionsmessungen an strahlenhärtenden Lacksystemen T2 - 8. UCB Radcure-Symposium CY - Dresden, Germany DA - 1997-09-11 PY - 1997 AN - OPUS4-7253 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Horn, Wolfgang T1 - Emissionsmessungen an Materialien mit Hilfe von Prüfkammern sowie direkter thermischer Extraktion T2 - Gerstel-Anwenderseminar CY - Hamburg, Germany DA - 2005-05-31 PY - 2005 AN - OPUS4-7563 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris A1 - Rother, Ingrid T1 - Comparison of different types of emission test chambers and cells regarding VOC- and SVOC-emission T2 - Indoor Air 2005 CY - Beijing, PR China DA - 2005-09-04 KW - Emission KW - Chamber KW - Cell KW - Building product KW - VOC KW - SVOC PY - 2005 SN - 7-89494-830-6 IS - 2 SP - 6 pages PB - Tsinghua University Press CY - Beijing AN - OPUS4-11075 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Jann, Oliver A1 - Rockstroh, Jens A1 - Wilke, Olaf T1 - Influence of emissions from hardcopy devices to indoor air quality T2 - Indoor Air 2005 CY - Beijing, PR China DA - 2005-09-04 KW - VOC KW - TVOC KW - Dust KW - Ozone KW - Hardcopy devices PY - 2005 SN - 7-89494-830-6 IS - 2 SP - 6 pages PB - Tsinghua University Press CY - Beijing AN - OPUS4-11074 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hahn, Oliver A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Characterization of air quality in museum show cases N2 - The present study comprises the characterisation of museum show cases concerning their hazardous potential for art objects. In order to estimate potential risks of damage the emission of volatile organic compounds coming from several construction materials is monitored and different air exchange rates from exhibit cases are determined. For the determination of the VOCs different methods were applied. The first step is a direct thermal extraction of the materials followed by emission test chamber measurements. The tracer gas method with N2O that is used in this study is a convenient procedure to investigate air exchange rates under working conditions greater than 0.05 d-1. The results of this study confirm the importance of the careful choice concerning building materials for show cases. Furthermore the analyses clarify that certain organic compounds might be a problem for the exhibits in show cases with low air exchange rates. T2 - Indoor Air 2005 CY - Beijing, PR China DA - 2005-09-04 KW - VOC KW - SVOC KW - Emission chamber test KW - Direct thermal extraction KW - Cultural heritage PY - 2005 SN - 7-89494-830-6 IS - 2 SP - 2269 EP - 2273 PB - Tsinghua University Press CY - Beijing AN - OPUS4-7602 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Torge, Manfred A1 - Wilke, Olaf A1 - Brödner, Doris T1 - Effects of emissions of materials for wrapping, transportation and storage on stained glass windows and on glass objects in show cases in museums N2 - The emission of volatile organic compounds (VOC) of materials for wrapping, transportation and storage of stained glass windows were investigated by direct thermal desorption. The analysis was performed with thermal desorption in combination with gas chromatography and mass spectrometry. Emissions of organic acids were determined. The damage risk of volatile organic compounds, e.g. organic acids as acetic acid, propanoic acid, hexanoic acid and octanoic acid was investigated on model glasses in climate chambers. After exposure the surface of the most sensitive samples was damaged. Based on emission measurements in exhibit cases of the former museum "Grünes Gewölbe in the Albertinum" in Dresden, Germany, the atmospheric conditions inside the show cases were determined. It can be shown that the atmospheric conditions inside the cases endanger the glass and enamel objects of art especially in show cases with low air exchange rates. Materials with high emission rates of organic acids should not be in direct contact with medieval glass for a long time and should not be used in exhibit cases. Acid emissions, especially acetic acid plays an important role during investigation of different materials for show cases and can be determined by direct thermal desorption. T2 - Art 2008, 9th International Conference CY - Jerusalem, Israel DA - 2008-05-25 KW - Emissionen KW - Volatile Organic Compounds KW - Glas KW - Medieval staind glass PY - 2008 UR - http://www.ndt.net/article/art2008/papers/059Torge.pdf IS - CD-ROM SP - 1 EP - 9 PB - ISAS International Seminars CY - Jerusalem, Israel AN - OPUS4-17600 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hahn, Oliver A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Indoor air quality in show cases - an attempt to standardise emission measurements KW - Cultural heritage KW - Indoor air quality KW - Emission measurements PY - 2007 SN - 0931-7198 VL - 21 IS - 2 SP - 275 EP - 279 PB - Werner CY - Worms AN - OPUS4-17435 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang T1 - Interlaboratory study on VOC emission testing T2 - CEN TC 351 WG 2, DIBt CY - Berlin, Germany DA - 2008-04-07 PY - 2008 AN - OPUS4-17618 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf T1 - Durchführung eines Rundversuchs zur Messung von flüchtigen organischen Verbindungen im Rahmen der gesundheitlichen Bewertung von Bauprodukten, Interlaboratory study on VOC emission testing T2 - Abschlussveranstaltung zum Vorhaben 4532 "Durchführung eines Rundversuchs zur Messung von flüchtigen organischen Verbindungen im Rahmen der gesundheitlichen Bewertung von Bauprodukten, DIBt CY - Berlin, Germany DA - 2008-04-09 PY - 2008 AN - OPUS4-17615 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf T1 - Europäischer Rundversuch zur Bestimmung von VOC mittels Thermodesorption T2 - 15. WaBoLu-Innenraumtage, Umweltbundesamt CY - Berlin, Germany DA - 2008-04-28 PY - 2008 AN - OPUS4-17616 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Seeger, Stefan A1 - Wilke, Olaf A1 - Bücker, Michael A1 - Jann, Oliver T1 - Time- and Size-Resolved Characterization of Particle Emissions from Office Machines with Printing Function T2 - Healthy Buildings 2006 CY - Lisboa, Portugal DA - 2006-06-04 KW - Hard copy devices KW - Laserprinters KW - Toner KW - Particle emissions KW - Particles KW - Aerosols PY - 2006 SN - 978-989-95067-1-8 VL - 2 SP - 447 EP - 450 CY - Lissabon AN - OPUS4-14522 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Teppich, Holzboden oder elastischer Bodenbelag? Versuch eines Vergleichs der chemischen Emissionen T2 - IBK-Symposium 330: Bauen, leben, wohnen - Gesundheit als Einheit CY - Berlin, Germany DA - 2006-09-06 PY - 2006 AN - OPUS4-13245 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris A1 - Schneider, Uwe A1 - Krocker, Christian A1 - Kalus, Sabine A1 - Seeger, Stefan A1 - Bücker, Michael T1 - Prüfung von Emissionen aus Bürogeräten während der Druckphase zur Weiterentwicklung des Umweltzeichens Blauer Engel für Laserdrucker und Multifunktionsgeräte unter besonderer Berücksichtigung der Sicherung guter Innenraumluftqualität KW - Emissionen KW - Emissionsmesskammern KW - VOC KW - TVOC KW - Ozon KW - Staub KW - RAL-UZ 122 KW - Blauer Engel KW - Bürogerät KW - Laserdrucker KW - Partikel PY - 2008 UR - http://www.umweltbundesamt.de/publikationen/pruefung-von-emissionen-aus-buerogeraeten-waehrend SN - 1862-4804 VL - 35 IS - 8 SP - 1 EP - 164 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-18265 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seeger, Stefan A1 - Wilke, Olaf T1 - Prüfkammermessungen zur Erfassung von VOC- und Partikelemissionen aus Laserdruckern T2 - 15. WaBoLu-Innenraumtage des Vereins für Wasser-, Boden- und Lufthygiene e. V., Gelsenkrichen, Umweltbundesamt CY - Berlin, Germany DA - 2008-04-28 PY - 2008 AN - OPUS4-18549 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Möglichkeiten zur Emissionsmessung - Erfassung von flüchtigen organischen Verbindungen aus Vitrinenmaterialien T2 - 3. N.i.Ke.-Workshop CY - Berlin, Germany DA - 2009-02-09 PY - 2009 AN - OPUS4-19076 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Jann, Oliver A1 - Bremser, Wolfram A1 - Brödner, Doris A1 - Kalus, Sabine A1 - Juritsch, Elevtheria A1 - Till, Carola T1 - Untersuchungen zur Verbesserung der Messung von flüchtigen organischen Verbindungen aus Fußbodenbelägen im Rahmen der gesundheitlichen Bewertung von Bauprodukten T1 - Investigations for the improvement of the measurement of volatile organic compounds from floor coverings within the health-related evaluation of construction products N2 - In den Grundsätzen des DIBt zur gesundheitlichen Bewertung von Bauprodukten in Innenräumen ist das Bewertungsschema des Ausschusses zur gesundheitlichen Bewertung von Bauprodukten (AgBB-Schema) als wesentliche Grundlage enthalten. Dieses Schema bewertet die mit Hilfe einer Prüfkammermessung bestimmten Emissionen von flüchtigen und schwer flüchtigen organischen Verbindungen (VOC und SVOC). Die Prüfkammer dient dabei der Einhaltung standardisierter Klimabedingungen (Temperatur 23°C, relative Luftfeuchtigkeit 50 %) sowie der Einstellung bestimmter Prüfparameter wie Luftwechselrate und Beladungsfaktor. Die Anforderungen an eine Prüfkammer sind in DIN EN ISO 16000-9 beschrieben. Die Analytik und Quantifizierung der VOC geschieht mittels Tenax-Thermodesorption und nachfolgender Gaschromatographie gekoppelt mit Massenspektrometrie und ist in DIN ISO 16000-6 beschrieben. Probenahmen werden am 3. und 28. Tag der Prüfkammermessung durchgeführt. Am dritten Tag erfolgt eine Bewertung der Emissionen aus dem Bauprodukt anhand des TVOC-Wertes und der Summe der detektierten cancerogenen Stoffe (nach 67/548/EWG, Einstufung als cancerogen der Kategorie 1 und 2). Ein Produkt erfüllt die Kriterien, wenn der TVOC-Wert nach 3 Tagen nicht größer als 10 mg/m³ ist und die Summe der Cancerogene 10 μg/m³ nicht übersteigt. Am 28. Tag wird zusätzlich zum TVOC-Wert und den Cancerogenen die Emission von SVOCs berücksichtigt und eine Einzelstoffbewertung anhand von NIK-Werten vorgenommen. Der TVOC-Wert nach 28 Tagen darf nicht größer als 1 mg/m³ sein, die Summe der Cancerogenen nicht größer als 1 μg/m³. Die Summe an SVOCs darf eine Konzentration von 0,1 mg/m³ nicht überschreiten. Der sogenannte R-Wert, die Summe aller Quotienten aus Einzelstoffkonzentration und dem NIK-Wert des Einzelstoffes, darf einen Wert von 1 nicht übersteigen. Außerdem darf die Summe von Substanzen, die keinen NIK-Wert besitzen, nicht größer als 0,1 mg/m³ sein. Der Ringversuch, der im Rahmen der Untersuchungen zur Verbesserung der Prüfkammermessungen durchgeführt wurde, hatte vor allem den Zweck, den Einfluss unterschiedlicher Methodenparameter bei der Prüfkammermessung in unterschiedlichen Prüflaboratorien zu erfassen. Anhand der Ergebnisse sollte eine Ursachenforschung für die großen Abweichungen der bisher durchgeführten Ringversuche erfolgen. Durch die drei aufeinander aufbauenden Schritte sollte der Einfluss der Analytik, der Probenahme und der Prüfkammer geklärt werden. Der Ringversuch diente nicht der Anerkennung der teilnehmenden Prüflaboratorien im Bereich der Bauproduktenprüfung für eine DIBt-Zulassung. Ausgehend von den Prüflaboratorien, die in der Projektgruppe „Prüf- und Messverfahren zur gesundheitlichen Bewertung von Bauprodukten“ des DIBt mitarbeiteten, wurde der Kreis auf europäische Prüflaboratorien erweitert, die sich ebenfalls mit Prüfkammermessungen an Bauprodukten beschäftigen. Dazu erging ein Einladungsschreiben an alle von vorangegangenen Ringversuchen bekannten Teilnehmer. Insgesamt ergab sich ein Teilnehmerkreis von 29 Instituten, davon 16 aus Deutschland, jeweils zwei aus Österreich, Belgien, Schweden, Dänemark und jeweils eins aus Finnland, Großbritannien, Frankreich, Italien und Portugal. Vor Beginn des Ringversuches waren davon 11 im Zulassungsbereich tätig. Zur wissenschaftlichen Begleitung wurde durch das DIBt ein Betreuergremium einberufen. In zwei Sitzungen (April und November 2007) wurden die aktuellen Ergebnisse vorgestellt und diskutiert sowie die weitere Vorgehensweise besprochen. Eine Abschlussveranstaltung nach der Auswertung des dritten Schrittes des Ringversuches fand im April 2008 im DIBt statt. Dazu waren alle Teilnehmer eingeladen. Für die Emissionsmessung von flüchtigen organischen Verbindungen (VOC) aus Materialien mit Hilfe von Emissionsprüfkammern sind bisher nur wenige Ringversuche durchgeführt worden (De Bortoli et al. 1999; Jann et al. 2000; Hansen et al. 2000; Oppl and Winkels 2002; Windhövel and Oppl 2005; Kirchner 2007; Oppl 2008). Dabei zeigten sich meist große Streuungen der Ergebnisse. Ein großes Problem für die Durchführung solcher Ringversuche ist das Fehlen von Referenzmaterialien mit bekannter Emissionsrate von Zielsubstanzen. Deshalb orientiert man sich für die Auswertung solcher Ringversuche am Mittelwert aller Ergebnisse. Dafür ist die Homogenität des Testmaterials von größter Bedeutung. Diese wurde in früheren Ringversuchen nicht wirklich sichergestellt. Im hier beschriebenen Forschungsprojekt wurde auf die Homogenität des Probenmaterials besonderen Wert gelegt. Der gesamte Ringversuch wurde in drei Schritte unterteilt. Die einzelnen Schritte wurden dabei von Schritt zu Schritt immer komplexer. Im ersten Schritt erfolgte die Analyse von flüssigen Lösungen, im zweiten die Bestimmung von VOCs in Prüfkammerluft und im dritten Schritt erfolgte eine komplette Emissionsprüfkammermessung bei den Teilnehmern. N2 - In the German Institute for Construction Technology’s (DIBt) principles for the health assessment for construction products used in interiors, the Evaluation procedure of the Committee for Health-related Evaluation of Building Products (AgBB Scheme) is contained as a substantial base. This scheme evaluates the emissions of volatile and semivolatile organic compounds (VOC and SVOC), determined by test chamber measurements. Within the interlaboratory comparison, which was divided into three steps, the emission test method from building products was checked against the principles of health-related evaluation of construction products in indoor spaces (based on DIN EN ISO 16000-9 together with DIN ISO 16000-6) with the co-operation of 29 European test institutes. The objective was to assess the comparability of the test method carried out in different test Chambers and using different thermodesorption devices. In the first step the analysis of liquid solutions took place to observe the influence of the analysis itself. In the second step VOCs were sampled in the air of a BAM test chamber onto tubes from the participants for the Analysis by them. In the third step a complete Emission test chamber measurement was carried out by the participants. A major problem for the execution of such interlaboratory comparisons is the lack of reference materials. Therefore the homogeneity of the test material was of great importance. As a result of the first step (analysis of 4 liquid solutions) a standard deviation of less than 20 % for 8 out of 11 substances tested was obtained. The Standard deviations for dichloropropanol, caprolactam and Butyl diglycol ranged up to 36 %. The second step, which included air sampling at a BAM test chamber, resulted in only one standard deviation value less than 20 % (11 % for styrene). The standard deviations for the other six substances were between 20 % and 36 %. For step 3 a sealant was chosen instead of the flooring material for homogeneity reasons. In step 3 the standard deviations for 4 of the 7 measured VOC concentrations from two chamber tests were between 17 % and 19 % and thus within the same range as in Step 1 and even better than for most substances in Step 2. A Standard deviation of 60 % was found for the key component ethanediol, but this can be explained with the difficult analysis method for this substance. A second objective of the project was to formulate criteria against which the specialist competence of the test institutes for emission tests can be checked and based on the principles for the health assessment for construction products used in interior. For this purpose a catalogue of criteria has been developed, which is divided into three parts. In the first part, basic requirements are formulated such as impartiality, accreditation for test chamber measurements, verification of experience by participation in earlier interlaboratory comparisons and the laboratory equipment. The second part requires the test-specific proof in the form of successful participation in interlaboratory comparisons organised by BAM biannually. The third part instructs the laboratories that they must ensure they are always upto-date both in terms of their knowledge and the available equipment. The quality assurance for the knowledge is ensured by regular participation in the exchanging of experience between the test laboratories. In terms of technical requirements the test institutes must be willing to successfully participate in at least one interlaboratory comparison per year. The present interlaboratory comparison was not designed to recognise the participating test laboratories in the field of the construction product testing for a DIBt approval. KW - Ringversuch KW - Laborvergleich KW - VOC-Emissionen KW - Kammermessungen KW - Round robin KW - Inter laboratory study KW - VOC emissions KW - Emission test chamber PY - 2009 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-198380 UR - https://www.baufachinformation.de/buch/Untersuchungen-zur-Verbesserung-der-Messung-von-fl%C3%BCchtigen-organischen-Verbindungen-aus-Fu%C3%9Fbodenbel%C3%A4gen-im-Rahmen-der-gesundheitlichen-Bewertung-von-Bauprodukten/230803 SN - 978-3-8167-8100-4 N1 - Sprachen: Deutsch/Englisch - Languages: German/English IS - T 3217 SP - 1 EP - 206 PB - Fraunhofer IRB Verl. CY - Stuttgart AN - OPUS4-19838 LA - mul AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Method validation study for VOC emission measurements N2 - Quality and trueness of results received from measurements are very important for all involved parties, producers and consumers as well; for instance, if the results were used for acceptance of a product within a labeling procedure. Based on an inter-laboratory study with many German, European and US-American laboratories an extemal quality assurance System for the analysis of VOC emitting from products or the measurement in indoor air should be implemented (financed by the German Federal Environmental Agency). A focus was set on the emission test chamber experiments and the connected analytical procedure. VOC have a dominating influence when applying the German AgBB scheme for health evaluation of building products. Therefore it is necessary to ensure that the results between the testing laboratories are comparable. The successful participation to such round robin tests is offen essential for the acceptance of results given by an analytical laboratory. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Round robin test KW - VOC KW - Construction product KW - Emission PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23880 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Wiegner, Katharina T1 - Inter-laboratory study to check the performance ot test chamber measurements for product emission testing N2 - The labelling of construction products or building materials as “low-emitting” is based on measurements using third-party emission test chambers. Unfortunately there is no method to validate the performance of such test chamber measurements. This might give a Variation of results when testing one material at different laboratories. Therefore it is necessary to hold round robin tests as part of the quality management System to ensure comparable results. A research project financed by the Federal Environmental Agency focused on the development of an external quality management System for the detection of relevant Chemical compounds from products and in ambient air. The project was structured in four phases (Horn et al., 2009 and 2011; Wilke et al., 2009a) This paper shows results of the fourth phase of the project, which was an inter-laboratory study for VOC-emission testing by means of emission test chambers. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Emission test chamber KW - Product emission testing KW - VOC-Emission KW - Round robin test PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23884 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Wiegner, Katharina A1 - Scheffer, Harald A1 - Brödner, Doris T1 - VOC-Emissions from Plywood boards N2 - Wood and wood products are often used as construction material for buildings and even more for furniture and indoor decoration. Therefore Chemical emissions from wood have an influence on the indoor air quality. A research project financed by the Federal Environmental Agency focused on VOC emissions from oriented Strand boards (OSB) and also from plywood made from pine and spruce (Wilke et al., 2011a). This paper shows results of the plywood testing because only little information is available about plywood emission behaviour and its impact on indoor air quality. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - VOC-Emission KW - Plywood KW - Terpenes KW - Aldehydes KW - Indoor air quality PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23885 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris A1 - Scheffer, Harald A1 - Kalus, Sabine T1 - Emissionsminderung von Aldehyden durch den Einsatz von Antioxidantien bei der OSB-Plattenherstellung T2 - 8. Holzwerkstoff-Kolloquium - Ressourcenschonender Rohstoffeinsatz und energieeffiziente Technologien CY - Dresden, Deutschland DA - 2009-12-10 KW - OSB KW - VOC KW - Oriented strand board KW - Volatile organic compound KW - Emissionen KW - Reduktion KW - Aldehyde KW - Antioxidantien KW - Holz PY - 2009 SP - 1 EP - 7 AN - OPUS4-20675 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Till, Carola T1 - Interlaboratory study with Tenax thermal desorption - Phase 2 - Tenax tubes spiked by BAM T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - ISO 16000-6 KW - Interlaboratory study KW - VOC KW - External quality management system PY - 2009 IS - Paper 345 SP - 1 EP - 2 CY - Syracuse, NY, USA AN - OPUS4-20094 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Brödner, Doris A1 - Juritsch, Elevtheria A1 - Till, Carola A1 - Kirchner, D. T1 - European Interlaoratory Study for Sampling VOC Emissions - Step 3 - Emission test champer measurements T2 - Healthy Buildings CY - Syracuse, NY, USA DA - 2009-09-13 PY - 2009 AN - OPUS4-20091 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Wiegner, Katharina T1 - Inter-laboratory Study to Check the Performance of Test Chamber Measurements for Product Emission Testing T2 - International Conference on Indoor Air 2011 CY - Austin, TX, USA DA - 2011-06-05 PY - 2011 AN - OPUS4-24138 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Wiegner, Katharina A1 - Brödner, Doris A1 - Scheffer, Harald T1 - VOC-Emissions from Plywood Boards T2 - Conference on Indoor Air 2011 CY - Austin, TX, USA DA - 2011-06-05 PY - 2011 AN - OPUS4-24142 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Wilke, Olaf A1 - Wiegner, Katharina A1 - Jann, Oliver A1 - Brödner, Doris A1 - Scheffer, Harald T1 - Emissionsverhalten von Holz und Holzwerkstoffen (UBA-FB 001580) N2 - In diesem Vorhaben wurden 8 OSB-Platten und sieben Leimholzplatten aus Baumärkten gemäß den Vorgaben des AgBB-Schemas in Emissionsmesskammern geprüft. Hinzu kamen Messungen an 17 im Technikum hergestellten OSB, an denen der Einfluss von Herstellungsparametern auf VOCEmission untersucht wurde. Grundsätzliches Ziel war es, durch die Untersuchungen Lösungsansätze für die Emissionsminderung von VOC aus Holzwerkstoffen zu finden. Dazu wurde auch der Einsatz von Antioxidantien bei der OSB-Herstellung getestet. Die Emissionen des Rohstoffes Kiefernholz wurden an 6 Proben aus Splint- oder Kernholz aus unterschiedlichen Stammabschnitten einer frisch gefällten Kiefer untersucht. Insgesamt konnte mit dem Projekt gezeigt werden, dass einige der im Handel erhältlichen OSB und auch Leimhölzer eine Bewertung nach dem AgBB-Schema aufgrund von zu hohen Aldehyd- und Terpenemissionen nicht bestehen. Für die Aldehydemissionen (insbesondere Hexanal und ungesättigte höhere Aldehyde) konnte durch den Einsatz von Antioxidantien bei der OSB-Herstellung eine Verminderung auf ein Drittel erreicht werden, allerdings stiegen dadurch die Terpenemissionen an. In this project, eight Oriented Strand Boards (OSB) and seven plywood boards from DIY stores were tested in emission test chambers according to the AgBB scheme’s specifications. In addition, 17 OSBs manufactured in a pilot plant were tested to investigate the effect of production parameters on VOC emission. The use of antioxidants in OSB production was also tested. The main objective of the investigation was to find potential solutions for reducing VOC emissions from timber materials. The emissions from pine wood were investigated on six sapwood or heartwood samples from different trunk sections of freshly felled pine. The project’s results show that, due to their high aldehyde and terpene emissions, some types of commercially available OSB and plywood did not meet the AgBB scheme’s requirements. By using antioxidants in OSB production it was possible to reduce aldehyde emissions (especially hexanal and unsaturated higher aldehydes) to one third. However, this caused an increase in terpene emissions. KW - Bauprodukte KW - AgBB-Schema KW - Emissionsprüfkammern KW - Geruchsmessungen KW - VOC KW - VVOC KW - SVOC KW - Thermodesorption KW - GC/MS KW - Holzwerkstoffe KW - OSB KW - Leimholz KW - Construction products KW - AgBB Scheme KW - Emission test chamber KW - Odour measurement KW - Thermal desorption KW - Wood Products KW - Oriented Strand Board KW - Plywood Board PY - 2012 UR - http://www.umweltbundesamt.de/publikationen/emissionsverhalten-von-holz-holzwerkstoffen IS - 07 SP - 1 EP - 224 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-25843 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Emissions of very volatile organic compounds (VVOC) from particle boards N2 - The latest version of the German AgBB evaluation scheme (2015) for construction products includes some VVOC, e.g. formaldehyde, acetaldehyde and acetone. For these VVOC so-called LCI values (lowest concentration of interest) were derived which are used for the calculation of the so-called R-value (risk index, see reference 1 for the calculation). Test chamber measurements of particle boards show that the emissions of VVOC might have significant impact on the R-value and therefore for the health evaluation. T2 - Indoor Air 2016, The 14th international conference of Indoor Air Quality and Climate CY - Gent, Belgium DA - 03.07.2016 KW - Formaldehyde KW - AgBB evaluation scheme KW - VVOC KW - Particle board KW - OSB KW - Emission test chamber PY - 2016 AN - OPUS4-37033 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Emissions of very volitale organic compounds (VVOC) from particle boards N2 - The latest version of the German AgBB evaluation scheme (2015) for construction products includes some VVOC, e.g. formaldehyde, acetaldehyde and acetone. For these VVOC so-called LCI values (lowest concentration of interest) were derived which are used for the calculation of the so-called R-value (risk index, see reference 1 for the calculation). Test chamber measurements of particle boards show that the emissions of VVOC might have significant impact on the R-value and therefore for the health evaluation. T2 - The 14th international conference of Indoor Air Quality and Climate, Indoor Air 2016 CY - Gent, Belgium DA - 03.07.2016 KW - Formaldehyde KW - AgBB evaluation scheme KW - Particle board KW - OSB KW - VVOC KW - Emission test chamber PY - 2016 SP - Paper 965, 1 AN - OPUS4-37030 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Janine A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Grundlagen und Hintergrundinformation im UFOPLAN-Vorhaben FKZ 3714953100 N2 - Zur Definition geeigneter Prüfbedingungen und zur Auswahl geeigneter Holzwerkstoffe für die im Vorhaben (UFOPLAN-Vorhaben Standardisierte Formaldehyd- und VOC-Messungen bei Holzwerkstoffen FKZ 3714 95 310 0) geplanten Untersuchungen wurde eine Recherche zu Forschungsergebnissen bezüglich realer Bedingungen (Luftwechsel, Beladung, klimatische Bedingungen im Sommer) durchgeführt. Zu bekannten Fällen von Überschreitungen wurde recherchiert, welche Produkte als Emissionsquellen in Frage kommen. Unter diesem Gesichtspunkt wurden auch Berichte abgeschlossener Forschungsvorhaben ausgewertet. T2 - 2. Fachbeirat zum UFOPLAN-Vorhaben Standardisierte Formaldehyd- und VOC-Messungen bei Holzwerkstoffen (FKZ 3714 95 310 0) CY - Berlin, Germany DA - 14.06.2016 KW - Formaldehyd KW - Holzwerkstoffe KW - VOC KW - Prüfverfahren PY - 2016 AN - OPUS4-38768 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Janine A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Standardisierte Formaldehyd- und VOC-Messungen N2 - Der Innenraumluftrichtwert für Formaldehyd in Höhe von 0,1 ppm ist durch das BfR bestätigt worden und bleibt bis auf weiteres bestehen. Die Prüfbedingungen für Formaldehydemissionen aus Holzwerkstoffen dagegen sind nicht mehr aktuell. Das Prüfverfahren für Holzwerkstoffe gilt seit 1991 und basiert auf dem Gebäudestandard von 1984. Eine Definition und Anpassung der Prüfbedingungen an moderne „dichtere“ Bauweise ist notwendig. Es zeigt sich, dass für Verbraucherinnen und Verbraucher eine Unterscheidung von formaldehydbelasteten und -unbelasteten Produkten in der Praxis schwierig ist. Es kann zu fehlerhaftem Einsatz und nicht fachgerechter Verarbeitung der Holzwerkstoffe kommen. Das Ziel des Vorhabens ist die möglichst sichere Einhaltung des Schutzniveaus durch die Anpassung der Prüfbedingungen an den heutigen Gebäudestandard. Aktuelle Versuche und Ergebnisse des Projektes werden vorgestellt. Ergänzende Screening-Versuche (Prüfkammermessungen) weisen Formaldehydemissionen bei verschiedenen Holzwerkstoffen aus dem Handel nach. Für die betrachteten OSB-Platten sind die FA-Emissionen im Allgemeinen geringer als für die untersuchten Spanplatten. Die OSB-Platten zeigen höhere Emissionen für Aceton und Hexanal als die Spanplatten. An ausgewählten Werkstoffen wurden Versuche zu den Auswirkungen einer individuellen Bearbeitung und Messungen unter veränderten Prüfbedingungen durchgeführt. Zum einem wurde schrittweise der Luftwechsel von 1 bis 0,2 1/h reduziert. Zum anderen wurden die Werkstoffe unter sommerlichen Bedingungen vermessen. Die Reduzierung des Luftwechsels ruft einen Anstieg der Formaldehyd-Konzentration hervor, dieser Effekt ist jedoch für einige VOCs stärker ausgeprägt. Bei Luftwechseln von 0,2-0,3 1/h, welche in der Praxis in Gebäuden erreicht werden können, ist eine Überschreitung des Formaldehyd-Grenzwertes von 0,1 ppm vor allem für Spanplatten möglich. Die VOC-Emission steigt unter sommerlichen Bedingungen an, es zeigt sich aber ein schnelles Abklingen nach kurzer Zeit. Die erhöhte Formaldehydemission bleibt über einen längeren Zeitraum erhalten. Die Bearbeitung von unbeschichteten Holzwerkstoffen (in mehrere Teile zersägt) führt zu einem kurzzeitigen Anstieg der FA- und VOC-Emission, nach einer bestimmten Abklingzeit (wenige Tage) wird erneut der Ausgangswert erreicht. Es wurden weiterhin Messungen zu Kombinationen aus OSB- und Spanplatten und einem Holzmöbel durchgeführt. Trotz Erhöhung der Beladung und Beibehalten des Luftwechsels konnte nur ein geringer Anstieg der Formaldehyd- und VOC-Konzentration beobachtet werden. Es erfolgte keine Addition der Einzelkonzentration. T2 - 2. Fachbeirat zum UFOPLAN-Vorhaben Standardisierte Formaldehyd- und VOC-Messungen bei Holzwerkstoffen (FKZ 3714 95 310 0) CY - Berlin, Deutschland DA - 14.06.2016 KW - Formaldehyd KW - Holzwerkstoffe KW - VOC KW - Prüfverfahren PY - 2016 AN - OPUS4-38754 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Pech, Anja A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Analysis of very volatile organic compounds (VVOC) with thermal desorption GC-MS N2 - Most VVOC were rarely considered in the evaluation of construction products. (Salthammer, 2014) In Germany this will change because the latest version of the German AgBB scheme for health evaluation (2015) now include VVOC, e.g. ethyl acetate and ethanol. In this study selected compounds were tested with the procedure described in ISO 16017 and a method for measuring VVOC with thermal desorption was developed. Three different adsorbents Tenax TA, Carbograph 5TD and Carbopack X were tested to analyse VVOC according to ISO 16017. For the tested VVOC, Carbograph 5TD showed the best results under the chosen analytical conditions. T2 - Indoor Air 2016, The 14th international conference of Indoor Air Quality and Climate CY - Gent, Belgium DA - 03.07.2016 KW - Thermal desorption KW - VVOC KW - Carbograph 5TD KW - Carbopack X PY - 2016 AN - OPUS4-37037 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Richter, Janine A1 - Jann, Oliver T1 - Standardisierte Formaldehyd- und VOC-Messungen N2 - Der Innenraumluftrichtwert für Formaldehyd in Höhe von 0,1 ppm ist durch das BfR bestätigt worden und bleibt bis auf weiteres bestehen. Die Prüfbedingungen für Formaldehydemissionen aus Holzwerkstoffen dagegen sind nicht mehr aktuell. Das Prüfverfahren für Holzwerkstoffe gilt seit 1991 und basiert auf dem Gebäudestandard von 1984. Eine Definition und Anpassung der Prüfbedingungen an moderne „dichtere“ Bauweise ist notwendig. Es zeigt sich, dass für Verbraucherinnen und Verbraucher eine Unterscheidung von formaldehydbelasteten und -unbelasteten Produkten in der Praxis schwierig ist. Es kann zu fehlerhaftem Einsatz und nicht fachgerechter Verarbeitung der Holzwerkstoffe kommen. Das Ziel des Vorhabens ist die möglichst sichere Einhaltung des Schutzniveaus durch die Anpassung der Prüfbedingungen an den heutigen Gebäudestandard. Es werden das Projekt (UFOPLAN-Vorhaben FKZ 3714 95 310 0) und erste Messergebnisse vorgestellt. Erste Messungen von Holzwerkstoffen im laufenden Vorhaben unter „worst case“-Bedingungen (erhöhte Beladung, geringer Luftwechsel) zeigen hohe Formaldehyd-Emissionen. T2 - 1. Fachbeirat zum UFOPLAN-Vorhaben Standardisierte Formaldehyd- und VOC-Messungen bei Holzwerkstoffen (FKZ 3714 95 310 0) CY - Berlin, Germany DA - 15.01.2016 KW - Formaldehyd KW - Holzwerkstoffe KW - Prüfverfahren PY - 2016 AN - OPUS4-38753 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Seeger, Stefan A1 - Rasch, Fabian A1 - Erdmann, Kerstin A1 - Brödner, Doris A1 - Wilke, Olaf T1 - Weiterentwicklung des Prüfwertes für Ultrafeinstaubpartikel beim Umweltzeichen Blauer Engel für Drucker N2 - Berichtet wird über ein abgeschlossenes Folgeprojekt zu vorangegangenen Forschungsprojekte zum gleichen Thema. In diesem Projekt wurde das Messverfahren und der Prüfwert für die Partikelemission aus Bürogeräten (siehe Vergabegrundlage DE-UZ 205, Anhang S-M) validiert und weiterentwickelt. Dies geschah erstens durch Auswertung der Qualität der im Zuge der Antragsbearbeitung für das Umweltzeichen beim RAL vorgelegten Prüfberichte der zugelassenen Prüfinstitute und - basierend darauf - durch Erarbeitung von technisch-methodischen Veränderungsvorschlägen für die Prüfung der chemischen Emissionen, inklusive der Partikelemissionen. Zweitens wurde zur Beurteilung der Veränderung der Emissionen aktueller gegenüber älteren Geräte-generationen ein nicht repräsentativer Pool von table-top-Laserdruckern aufgebaut und die chemischen Emissionen wurden gemäß DE-UZ-205, Anhang S-M gemessen. Ergänzend wurde eine quantitative chemische Analyse der anorganischen Feststoffe - insbesondere der Metalle - in den emittierten Aerosolen vorgenommen die Feststoffgehalte um 2 Massen-% ergaben. Diese Ergebnisse wurden gemeinsam mit neueren wissenschaftlichen Untersuchungen zur gesundheitlichen Bewertung der Emissionen aus Laserdruckern ausgewertet, es besteht kein Handlungsbedarf hinsichtlich einer Veränderung von Prüfkriterien und Prüfwerten. Drittens wurde untersucht und bestätigt, dass mit dem Ziel eines zukünftigen Umweltzeichens das Emissionsverhalten Kunststoff verarbeitender 3D-FDM-Drucker und/oder die darin verarbeiteten Verbrauchsmaterialien (Filamente) mit dem für Laserdrucker entwickelten Mess- und Prüfschema charakterisiert und quantifiziert werden können. Untersuchungen an Stereo-lithografie (SLA)-Druckern und Vorrichtungen zur Nach-Aushärtung (Curing Units) ergaben keine nachweisbaren Partikelemissionen. KW - Blauer Engel KW - Bürogeräte mit Druckfunktion KW - Emissionen KW - Aerosole KW - Schadgase PY - 2020 UR - https://www.umweltbundesamt.de/publikationen/weiterentwicklung-des-pruefwertes-fuer SN - 1862-4804 VL - 217 SP - 5 EP - 82 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-51745 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf T1 - Emission Testing for Indoor Products N2 - The chemical emissions from products are tested by means of emission test chambers under defined conditions (climate, loading, air change rate). The standard method for the determination of volatile organic compounds (VOC) is the sampling onto Tenax-tubes followed by thermal desorption (TDS) and gas chromatography-mass spectrometry (GC-MS) analysis. The EU-LCI list includes some very volatile organic compounds (VVOC) and some VOC for which there are limitations when using the standard method. For VVOC additional sampling is required using stronger absorbers like Carbotrap or multi-bed adsorption tubes. The analysis of VVOC also requires a different GC oven program and a different column for the separation. For the determination of formaldehyde and other low boiling aldehydes (e.g. acetaldehyde, acetone, propanal, propenal) DNPH-cartridges are used which are extracted with acetonitrile followed by liquid chromatography (HPLC-UV) analysis. The derivatisation of propenal and other unsaturated aldehydes (e.g. 2-butenal) with DNPH might lead to lower findings due to incomplete derivatization and forming of by-products. For a better quantification of acetic acid the use of ion chromatography (IC) is recommended because the analysis of acetic acid with the standard method (TDS) leads to lower findings due to break through during sampling. The use of ion chromatography for the analysis of organic acids requires a third sampling technique. The acids are adsorbed onto silica-gel and extracted with water. T2 - ISESISIAQ 2019 CY - Kaunas, Lituania DA - 18.08.2019 KW - Indoor Air Quality KW - Emission Testing KW - Indoor Products KW - VOC Emission KW - Construction Products PY - 2019 AN - OPUS4-49406 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Standardisierte Formaldehyd- (und VOC-) Messungen bei Holzwerkstoffen zur Einspeisung der Daten in Normungsprozesse N2 - UBA und BAM schlagen die Durchführung der Prüfkammermessungen bei 23 °C und 50% relativer Luftfeuchte, einer Beladung von 1,8 m²/m³ und einem Luftwechsel von 0,5 pro Stunde vor. Diese Parameter orientieren sich an der EN 16516, die als zukünftige „Referenznorm“ zu betrachten ist. Die Schmalflächenversiegelung ist auch zukünftig wie in der EN 717-1 beschrieben vorzunehmen. Nach 28 Tagen wird der Mittelwert einer Doppelbestimmung als Endkonzentration („entsprechend der Ausgleichskonzentration“) berechnet. Alternativ dazu kann die Prüfung vorzeitig abgebrochen werden, wenn an 5 Messtagen der Prüfung eine Formaldehydkonzentration von 0,1 ppm nicht überschritten wird. Prüfungen nach der EN 717-1 sollen weiterhin gleichberechtigt möglich sein. Ergebnisse von Messungen, die nach der EN 717-1 ermittelt wurden, sind mit dem Faktor 2,0 zu multiplizieren. Abgeleitete Verfahren wie z.B. das Gasanalyseverfahren sollen weiterhin möglich sein. Das Perforatorverfahren entfällt hier, da eine allgemeine für alle Holzwerkstoffe gültige Korrelationen nicht existiert. Die entsprechenden Änderungen sind in der vom BMUB veröffentlichten „Bekanntmachung analytischer Verfahren für Probenahmen und Untersuchungen für die im Anhang der Chemikalien-Verbotsverordnung genannten Stoffe und Stoffgruppen“ entsprechend zu ändern. T2 - UFOPLAN Workshop CY - Berlin, Germany DA - 22.06.2018 KW - EN 717-1 KW - Prüfkammer KW - Formaldehyd KW - EN 16516 PY - 2018 AN - OPUS4-45632 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Liaskos, C. A1 - Rhoderick, G. A1 - Hodges, J. A1 - Possolo, A. A1 - Wilke, Olaf T1 - Pilot comparison CCQM-P177 - monoterpenes in nitrogen at 2.5 nmol/mol - final report N2 - Growing awareness of the impact of monoterpenes on climate, atmospheric chemistry, and indoor air quality has necessitated the development of measurement standards to globally monitor and control their emissions. For National Metrology Institutes to develop such standards, it is essential that they demonstrate measurement equivalence for assigned values at the highest levels of accuracy. This report describes the results of a pilot comparison for 4 key monoterpene species: α-pinene, 3-carene, R-limonene and 1,8-cineole, at a nominal amount-of-substance fraction of 2.5 nmol mol-1. The objective of this comparison is to evaluate participant capabilities to measure trace-level monoterpenes using their own calibration techniques. KW - Pilot comparison KW - CCQM KW - Monoterpene KW - Accuracy PY - 2020 U6 - https://doi.org/10.1088/0026-1394/57/1A/08018 SN - 0026-1394 SN - 1681-7575 VL - 57 IS - 1A SP - 08018-1 EP - 08018-21 PB - IOP Science AN - OPUS4-51111 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Even, Morgane A1 - Hutzler, C. A1 - Wilke, Olaf A1 - Luch, A. T1 - Emissions of volatile organic compounds from polymer-based consumer products: comparison of three emission chamber sizes N2 - The ISO 16000 standard series provide guidelines for emission measurements of volatile organic compounds (VOCs) from building materials. However, polymer-based consumer products such as toys may also release harmful substances into indoor air. In such cases, the existing standard procedures are unsuitable for official control laboratories due to high costs for large emission testing chambers. This paper aims at developing and comparing alternative and more competitive methods for the emission testing of consumer products. The influence of the emission chamber size was investigated as smaller chambers are more suited to the common size of consumer products and may help to reduce the costs of testing. Comparison of the performance of a 203 l emission test chamber with two smaller chambers with the capacity of 24 l and 44 ml, respectively, was carried out by using a polyurethane reference material spiked with 14 VOCs during the course of 28 days. The area-specific emission rates obtained in the small chambers were always similar to those of the 203 l reference chamber after a few hours. This implies that smaller chambers can provide at least useful numbers on the extent of polymer-based consumer product emissions into indoor air, thereby supporting meaningful exposure assessments. KW - Comparison KW - Consumer products KW - Emission chamber KW - Reference material KW - Volatile organic compounds PY - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-493697 VL - 30 IS - 1 SP - 40 EP - 48 PB - Wiley VCH-Verlag AN - OPUS4-49369 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Plehn, W. A1 - Brozowski, F. T1 - Untersuchungen zur Etablierung der DIN EN 16516 als neuer Referenznorm für die Prüfung von Formaldehydemissionen aus Holzwerkstoffen gemäß Chemikalien-Verbotsverordnung T1 - Investigations to establish DIN EN 16516 as new reference standard for testing of formaldehyde emissions from wood-based panels under the Chemikalien-Verbotsverordnung N2 - Im Januar 2018 wurde die DIN EN 16516 „Bauprodukte: Bewertung der Freisetzung gefährlicher Stoffe – Bestimmung von Emissionen in die Innenraumluft“ als harmonisierte europäische Prüfnorm veröffentlicht. Für die Etablierung der DIN EN 16516 als neue Referenznorm wurden verschiedene Emissionsprüfungen mit dem Ziel durchgeführt, ein neues Prüfverfahren für Formaldehydemissionen aus Holzwerkstoffen zu erarbeiten. Das übergeordnete Ziel ist die Minimierung des Risikos von Überschreitungen des Innenraumrichtwertes für Formaldehyd. Die Untersuchungen ergaben teilweise hohe Formaldehydemissionen, insbesondere bei höheren Beladungsfaktoren und Temperaturen, sowie bei niedrigen Luftwechselraten. Eine getestete Spanplatte hätte aufgrund ihrer hohen Formaldehydemission nicht auf den deutschen Markt gebracht werden dürfen. Durch vergleichende Untersuchungen konnte ein Umrechnungsfaktor in Höhe von 2,0 für die Umrechnung von Prüfwerten nach DIN EN 717-1 zu DIN EN 16516 abgeleitet werden. N2 - DIN EN 16516 "Construction products: Assessment of release of dangerous substances - Determination of emissions into indoor air" was published as a harmonized European standard in January 2018. For the establishment of DIN EN 16516 as the new reference standard various emission tests were carried out with the aim to develop a new test procedure for the measurement of formaldehyde emissions from wood-based panels. The superior aim is to minimize the risk of exceeding the indoor air reference value for formaldehyde. The investigations showed some particularly high formaldehyde emissions, especially at higher loading and temperature and at low air change rates. One of the tested particle boards exceeded the formaldehyde limit value and should not have been sold in Germany. For the conversion of test values from DIN EN 717-1 to DIN EN 16516 a conversion factor of 2.0 was derived from the comparative investigations. KW - Formaldehyd KW - DIN EN 16516 KW - Innenraumluft KW - Emissionsprüfung PY - 2019 SN - 0949-8036 VL - 79 IS - 3 SP - 79 EP - 85 PB - VDI Fachmedien CY - Düsseldorf AN - OPUS4-47666 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Formaldehydmessungen an Holzwerkstoffplatten N2 - Die von der BAM eingekauften Holzwerkstoffplatten (Verlegespanplatten, OSB, Multiplexplatten) verschiedener Hersteller zeigten teilweise hohe Formaldehyd-emissionen unter den Prüfbedingungen nach EN 16516, eine Spanplatte hielt den Grenzwert von 0,1 ppm selbst bei Prüfung nach DIN EN 717-1 nicht ein, dürfte also in Deutschland gar nicht in den Verkauf gelangen. Holzwerkstoffe, die unter den Prüfbedingungen der DIN EN 717-1 die Formaldehydklasse E1 einhalten, können insbesondere bei großflächigem Einsatz im Innenraum zu Überschreitungen des Richtwertes für die Innenraumluft führen. Zusätzlich zur Anpassung des Luftwechsels ist auch der Parameter Beladung bei einer Überarbeitung der Norm anzupassen. In der DIN EN 16516 werden produktspezifische (am Einsatz der Produkte orientierte) Beladungsfaktoren vorgegeben. Für den Einsatz von Holzwerkstoffplatten ergäben sich Beladungen von 0,4 (Boden oder Decke), 1,0 (Wände), 1,4 (Wände plus Boden oder Decke) und 1,8 m²/m³ (Wände, Boden und Decke). Um die realen Bedingungen in modernen Gebäuden abzubilden, ist deshalb eine Beladung von 1,8 m²/m³ für die Prüfkammermessung erforderlich. Hierbei ist darauf hinzuweisen, dass für die Beladung im Referenzraum Möbel nicht berücksichtigt wurden. Damit soll sichergestellt werden, dass die Einhaltung des Schutzniveaus bei realen Innenraumbedingungen auch unter den Randbedingungen eines niedrigen Luftwechsels sowie bei sommerlichen Bedingungen und heutigem Lüftungsverhalten der Menschen soweit wie möglich gewährleistet ist. T2 - 26. WaBoLu-Innenraumtage CY - Berlin, Germany DA - 20.05.2019 KW - Formaldehyd KW - Emissionsprüfkammer KW - DIN EN 16516 KW - DIN EN 717-1 PY - 2019 AN - OPUS4-48065 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tang, Chi-Long A1 - Wilke, Olaf A1 - Seeger, Stefan A1 - Kalus, Sabine A1 - Erdmann, Kerstin T1 - Chemical characterization of ultrafine particles released from 3D printers N2 - Previous studies have shown that desktop 3D printers (Fused Filament Fabrication) emit high numbers of particulate matter, mainly as ultrafine particles (UFP, particle diameter less than 100 nm). However, the chemical composition of emitted particles has been less extensively investigated. In this study, we therefore focused on the chemical composition of particles emitted from 3D printing. The measurements were conducted in a 1 m³ emission test chamber. Emitted particles were sampled by a 13-stage low-pressure cascade impactor onto aluminum foils and then analyzed by TD-GC/MS to identify their organic compounds. Nine commercial filaments made from basic polymers such as Acrylonitrile Butadiene Styrene (ABS), Acrylonitrile Styrene Acrylate (ASA), Polycarbonate (PC), Poly(methyl methacrylate) (PMMA), Nylon, High Performance Polystyrene (HIPS) and a copper-filled Polylactide (PLA) were investigated. The results show that the organic components of the particles are primarily plastic additives such as plasticizer, antioxidant agents, lubricants, UV-absorbers and UV-stabilizers from the filaments. T2 - 17th International Conference Healthy Buildings Europe 2021 CY - Online Meeting DA - 21.06.2021 KW - Chemical characterization KW - FFF-3D-Printer KW - UFP KW - Chamber measurement PY - 2021 SP - 251 EP - 252 AN - OPUS4-54255 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Seeger, Stefan A1 - Brödner, Doris A1 - Erdmann, Kerstin A1 - Rasch, Fabian T1 - Chemical characterization of ultra-fine particles released from laser printers N2 - 11 laser printers from 5 manufacturers were purchased in 2017 and tested for their UFP emissions. Size resolved sampling of the emitted particles was done with a 13 stage (30 nm to 10 µm) low pressure cascade impactor. The sampled particles were analysed for their chemical composition by thermal extraction (vaporization at 290°C) followed by GC-MS analysis. High boiling cyclic siloxanes (D10 to D16) were detected as constituents of UFP from laser printers. In comparison to measurements in 2008, aliphatic long-chain alkanes (C22 to C34) were detected additionally as chemical constituents of UFP from most of the tested printers and their amounts were higher than for cyclic siloxanes. Printers of one manufacturer showed very low UPF emissions compared to the other manufacturers. T2 - Indoor Air Conference 2022 CY - Kuopio, Finland DA - 12.06.2022 KW - UFP KW - Thermal extraction KW - Cascade impactor PY - 2022 SP - 1 EP - 4 AN - OPUS4-55106 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Seeger, Stefan A1 - Brödner, Doris A1 - Erdmann, Kerstin A1 - Rasch, Fabian T1 - Chemical characterization of ultra-fine particles released from laser printers N2 - 11 laser printers from 5 manufacturers were purchased in 2017 and tested for their UFP emissions. Size resolved sampling of the emitted particles was done with a 13 stage (30 nm to 10 µm) low pressure cascade impactor. The sampled particles were analysed for their chemical composition by thermal extraction (vaporization at 290°C) followed by GC-MS analysis. High boiling cyclic siloxanes (D10 to D16) were detected as constituents of UFP from laser printers. In comparison to measurements in 2008, aliphatic long-chain alkanes (C22 to C34) were detected additionally as chemical constituents of UFP from most of the tested printers and their amounts were higher than for cyclic siloxanes. Printers of one manufacturer showed very low UPF emissions compared to the other manufacturers. T2 - Indoor Air Conference 2022 CY - Kuopio, Finland DA - 12.06.2022 KW - UFP KW - Thermal extraction KW - Cascade impactor PY - 2022 AN - OPUS4-55107 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -