TY - JOUR A1 - Pecher, Heike Susanne A1 - Zimathies, Annett A1 - Weller, Michael G. T1 - Oligoepoxide-based monoliths: synthesis and application as affinity capillary column for enrichment of immunoglobulin G N2 - A series of new epoxide-based monoliths is synthesized by self-polymerization of polyglycerol polyglycidyl ether as porous support for affinity chromatography. Porosity and mean pore sizes are investigated as a function of the porogen ratio and analyzed by mercury porosimetry. The morphologies are visualized by environmental scanning electron microscope. With a particularly rigid monolith prepared with 75 vol% porogen (66% porosity and 12 µm mean pore size), a capillary column (0.5 mm ID) is prepared and directly functionalized with recombinant protein A to extract immunoglobulin G from rabbit serum. KW - Affinity chromatography KW - Affinity extraction KW - Glycidylethers KW - Macroporous polymers KW - Polyethers PY - 2012 U6 - https://doi.org/10.1002/macp.201200206 SN - 1022-1352 SN - 1521-3935 VL - 213 IS - 22 SP - 2398 EP - 2403 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-27390 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carvalho, José Joao A1 - Walter, Astrid A1 - Baermann, Yvonne A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schenk, J.A. A1 - Schneider, Rudolf T1 - Non-invasive monitoring of immunization progress in mice via IgG from feces N2 - A non-invasive method to monitor the humoral immune response in mice after immunization is described. From fecal pellets of an individual mouse, a sufficient amount of active immunoglobulins or their fragments can be extracted to perform a regular examination of the status of the immune response by immunoassay. Hapten-specific antibodies from the feces of mice from three immunization trials showed very similar characteristics to those obtained from serum at a given date. Therefore, it can be suspected that some serum IgG enters the intestinal lumen and ends up in the feces, where they appear to be considerably stable. Hapten-specific IgAs were not found in the feces. Being able to analyze antibody titers in feces could be an interesting animal welfare refinement to standard practice that does not entail repeated blood sampling. KW - Immunization monitoring KW - IgG KW - Coproantibodies KW - Feces KW - Animal welfare KW - 3R concept PY - 2012 UR - http://iv.iiarjournals.org/content/26/1/63.full.pdf+html SN - 0258-851x VL - 26 IS - 1 SP - 63 EP - 70 PB - In vivo CY - Athens AN - OPUS4-25283 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carvalho, José Joao A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - Monitoring caffeine in human saliva using a newly developed ELISA N2 - Caffeine is a useful indicator to quickly assess liver function. High-throughput tests are needed for single-point caffeine measurements, with low cross-reactivity toward its major metabolite, paraxanthine. A newly developed ELISA was compared with an LC-MS/MS reference method, using 60 saliva samples from 10 individuals, before and after caffeine intake. Bland-Altman plot, Student t-test and F-test were used to compare the two methods. Proteins were precipitated using organic solvent and the caffeine recoveries compared with those obtained using sample microfiltration. The antibody, with a low cross-reactivity toward paraxanthine (0.08%), allows quantification of caffeine in saliva samples from 2.5 µg/L to 125 µg/L with high precision and the ELISA shows comparable results to those obtained by LC-MS/MS. A one-step protein precipitation using an organic solvent provides comparable results to a more costly and time-consuming microfiltration pre-treatment of samples. The new ELISA is a fit-for-purpose method to accurately and precisely determine caffeine in saliva samples. KW - Caffeine KW - Cytochrome P450 CYP1A2 KW - Enzyme-linked immunosorbent assay KW - LC-MS/MS KW - Liver function tests KW - Saliva PY - 2012 U6 - https://doi.org/10.1080/00032719.2012.696226 SN - 0003-2719 SN - 1532-236X VL - 45 IS - 17 SP - 2549 EP - 2561 PB - Taylor & Francis CY - Philadelphia, Pa. AN - OPUS4-27267 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bahlmann, Arnold A1 - Carvalho, José Joao A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - Immunoassays as high-throughput tools: monitoring spatial and temporal variations of carbamazepine, caffeine and cetirizine in surface and wastewaters N2 - Carbamazepine (CBZ), caffeine and cetirizine were monitored by enzyme-linked immunosorbent assays (ELISAs) in surface and wastewaters from Berlin, Germany. This fast and cost-efficient method enabled to assess the spatial and temporal variation of these anthropogenic markers in a high-throughput screening. CBZ and cetirizine were detected by the same antibody, which selectively discriminates between both compounds depending on the pH value used in the incubation step. To our best knowledge, this is the first dual-analyte immunoassay working with a single antibody. The frequent sampling with 487 samples being processed allowed for the repeated detection of unusually high concentrations of CBZ and caffeine. ELISA results correlate well with the ones obtained by liquid chromatography tandem mass spectrometry (LC-MS/MS). Caffeine concentrations found in surface waters were elevated by combined sewer overflows after stormwater events. During the hay fever season, the concentrations of the antihistamine drug cetirizine increased in both surface and wastewaters. Caffeine was almost completely removed during wastewater treatment, while CBZ and cetirizine were found to be more persistent. The maximum concentrations of caffeine, CBZ and cetirizine found in influent wastewater by LC–MS/MS were 470, 5.0 and 0.49 µg L-1, while in effluent wastewater the concentrations were 0.22, 4.5 and 0.51 µg L-1, respectively. For surface waters, concentrations up to 3.3, 4.5 and 0.72 µg L-1 were found, respectively. KW - ELISA KW - Carbamazepine KW - Caffeine KW - Cetirizine KW - Environmental monitoring KW - Anthropogenic markers PY - 2012 U6 - https://doi.org/10.1016/j.chemosphere.2012.05.020 SN - 0045-6535 SN - 0366-7111 VL - 89 IS - 11 SP - 1278 EP - 1286 PB - Elsevier Science CY - Kidlington, Oxford AN - OPUS4-26187 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ramin, Steffen A1 - Weller, Michael G. T1 - Extremely sensitive and selective antibodies against the explosive 2,4,6-trinitrotoluene by rational design of a structurally optimized hapten N2 - Antibodies are a promising tool for the fast and selective trace detection of explosives. Unfortunately, the production of high-quality antibodies is not trivial and often expensive. Therefore, excellent antibodies are a rare and limiting resource in fields such as biosensing, environmental analysis, diagnostics, cancer therapy, and proteomics. Here, we report the synthesis, bioconjugation, and application of the structurally optimized hapten 6-(2,4,6-trinitro)-phenylhexanoic acid to improve the selectivity and sensitivity of antibodies for the detection of one of the most important explosives, trinitrotoluene. With a conjugate of bovine serum albumin and a highly purified N-hydroxy-succinimide (NHS)–activated hapten, two rabbits were immunized to obtain polyclonal antibodies. The immunization process was monitored by enzyme-linked immunosorbent assay to gain information about the progress of antibody titer and affinity. Finally, the polyclonal antibodies reached an affinity constant of (5.1 ± 0.6) × 109l/mol (rabbit R1) and (2.3 ± 0.2) × 109l/mol (rabbit R2). The respective assays show a minimum test midpoint (IC50 value) of 0.1 ± 0.01 µg/l (R1) and 0.2 ± 0.02 µg/l (R2) and a working range of 0.005 to 150 µg/l (R1) and 0.007 to 200 µg/l (R2), which corresponds to more than four orders of magnitude for both. This is quite remarkable for a competitive immunoassay, which is often believed to have a narrow dynamic range. The limit of detection was calculated to 0.6 ng/l (R1) and 1.5 ng/l (R2), which is up to 100 times improvement in relation to the assay of Zeck et al. (1999) on the basis of a monoclonal antibody. The excellent selectivity of the polyclonal antibodies was comprehensively examined by determining the cross-reactivity to common explosives and other nitroaromatics including nitro musk components. The widely held belief that polyclonal antibodies generally display higher cross-reactivities than monoclonals could be disproved. KW - Immunoassay KW - ELISA KW - Security KW - Terrorism PY - 2012 U6 - https://doi.org/10.1002/jmr.2162 SN - 0952-3499 SN - 1099-1352 VL - 25 IS - 2 SP - 89 EP - 97 PB - Heyden CY - London AN - OPUS4-25441 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schwarz, G. A1 - Beck, S. A1 - Weller, Michael G. A1 - Linscheid, M.W. T1 - Comparison of the fragmentation behavior of differentially metal-coded affinity tag (MeCAT)-labeled peptides PY - 2012 U6 - https://doi.org/10.1002/jms.3036 SN - 1076-5174 SN - 1096-9888 VL - 47 IS - 7 SP - 885 EP - 889 PB - Wiley CY - Chichester AN - OPUS4-27436 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weller, Michael G. T1 - A unifying review of bioassay-guided fractionation, effect-directed analysis and related techniques N2 - The success of modern methods in analytical chemistry sometimes obscures the problem that the ever increasing amount of analytical data does not necessarily give more insight of practical relevance. As alternative approaches, toxicity- and bioactivity-based assays can deliver valuable information about biological effects of complex materials in humans, other species or even ecosystems. However, the observed effects often cannot be clearly assigned to specific chemical compounds. In these cases, the establishment of an unambiguous cause-effect relationship is not possible. Effect-directed analysis tries to interconnect instrumental analytical techniques with a biological/biochemical entity, which identifies or isolates substances of biological relevance. Successful application has been demonstrated in many fields, either as proof-of-principle studies or even for complex samples. This review discusses the different approaches, advantages and limitations and finally shows some practical examples. The broad emergence of effect-directed analytical concepts might lead to a true paradigm shift in analytical chemistry, away from ever growing lists of chemical compounds. The connection of biological effects with the identification and quantification of molecular entities leads to relevant answers to many real life questions. KW - Toxicity KW - Drug discovery KW - Natural products KW - Environmental analysis KW - Lead identification PY - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-262960 SN - 1424-8220 VL - 12 IS - 7 SP - 9181 EP - 9209 PB - MDPI CY - Basel AN - OPUS4-26296 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -