TY - JOUR A1 - Bahlmann, Arnold A1 - Carvalho, José Joao A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - Immunoassays as high-throughput tools: monitoring spatial and temporal variations of carbamazepine, caffeine and cetirizine in surface and wastewaters N2 - Carbamazepine (CBZ), caffeine and cetirizine were monitored by enzyme-linked immunosorbent assays (ELISAs) in surface and wastewaters from Berlin, Germany. This fast and cost-efficient method enabled to assess the spatial and temporal variation of these anthropogenic markers in a high-throughput screening. CBZ and cetirizine were detected by the same antibody, which selectively discriminates between both compounds depending on the pH value used in the incubation step. To our best knowledge, this is the first dual-analyte immunoassay working with a single antibody. The frequent sampling with 487 samples being processed allowed for the repeated detection of unusually high concentrations of CBZ and caffeine. ELISA results correlate well with the ones obtained by liquid chromatography tandem mass spectrometry (LC-MS/MS). Caffeine concentrations found in surface waters were elevated by combined sewer overflows after stormwater events. During the hay fever season, the concentrations of the antihistamine drug cetirizine increased in both surface and wastewaters. Caffeine was almost completely removed during wastewater treatment, while CBZ and cetirizine were found to be more persistent. The maximum concentrations of caffeine, CBZ and cetirizine found in influent wastewater by LC–MS/MS were 470, 5.0 and 0.49 µg L-1, while in effluent wastewater the concentrations were 0.22, 4.5 and 0.51 µg L-1, respectively. For surface waters, concentrations up to 3.3, 4.5 and 0.72 µg L-1 were found, respectively. KW - ELISA KW - Carbamazepine KW - Caffeine KW - Cetirizine KW - Environmental monitoring KW - Anthropogenic markers PY - 2012 U6 - https://doi.org/10.1016/j.chemosphere.2012.05.020 SN - 0045-6535 SN - 0366-7111 VL - 89 IS - 11 SP - 1278 EP - 1286 PB - Elsevier Science CY - Kidlington, Oxford AN - OPUS4-26187 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carvalho, José Joao A1 - Walter, Astrid A1 - Baermann, Yvonne A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schenk, J.A. A1 - Schneider, Rudolf T1 - Non-invasive monitoring of immunization progress in mice via IgG from feces N2 - A non-invasive method to monitor the humoral immune response in mice after immunization is described. From fecal pellets of an individual mouse, a sufficient amount of active immunoglobulins or their fragments can be extracted to perform a regular examination of the status of the immune response by immunoassay. Hapten-specific antibodies from the feces of mice from three immunization trials showed very similar characteristics to those obtained from serum at a given date. Therefore, it can be suspected that some serum IgG enters the intestinal lumen and ends up in the feces, where they appear to be considerably stable. Hapten-specific IgAs were not found in the feces. Being able to analyze antibody titers in feces could be an interesting animal welfare refinement to standard practice that does not entail repeated blood sampling. KW - Immunization monitoring KW - IgG KW - Coproantibodies KW - Feces KW - Animal welfare KW - 3R concept PY - 2012 UR - http://iv.iiarjournals.org/content/26/1/63.full.pdf+html SN - 0258-851x VL - 26 IS - 1 SP - 63 EP - 70 PB - In vivo CY - Athens AN - OPUS4-25283 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weller, Michael G. A1 - Ramin, Steffen A1 - Walter, Astrid T1 - Detection of explosives by bioanalytical techniques T2 - Potsdam Days on Bioanalysis 2011 CY - Potsdam, Germany DA - 2011-11-09 PY - 2011 AN - OPUS4-24952 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schwarz, G. A1 - Beck, S. A1 - Weller, Michael G. A1 - Linscheid, M.W. T1 - Comparison of the fragmentation behavior of differentially metal-coded affinity tag (MeCAT)-labeled peptides PY - 2012 U6 - https://doi.org/10.1002/jms.3036 SN - 1076-5174 SN - 1096-9888 VL - 47 IS - 7 SP - 885 EP - 889 PB - Wiley CY - Chichester AN - OPUS4-27436 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weller, Michael G. T1 - A unifying review of bioassay-guided fractionation, effect-directed analysis and related techniques N2 - The success of modern methods in analytical chemistry sometimes obscures the problem that the ever increasing amount of analytical data does not necessarily give more insight of practical relevance. As alternative approaches, toxicity- and bioactivity-based assays can deliver valuable information about biological effects of complex materials in humans, other species or even ecosystems. However, the observed effects often cannot be clearly assigned to specific chemical compounds. In these cases, the establishment of an unambiguous cause-effect relationship is not possible. Effect-directed analysis tries to interconnect instrumental analytical techniques with a biological/biochemical entity, which identifies or isolates substances of biological relevance. Successful application has been demonstrated in many fields, either as proof-of-principle studies or even for complex samples. This review discusses the different approaches, advantages and limitations and finally shows some practical examples. The broad emergence of effect-directed analytical concepts might lead to a true paradigm shift in analytical chemistry, away from ever growing lists of chemical compounds. The connection of biological effects with the identification and quantification of molecular entities leads to relevant answers to many real life questions. KW - Toxicity KW - Drug discovery KW - Natural products KW - Environmental analysis KW - Lead identification PY - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-262960 SN - 1424-8220 VL - 12 IS - 7 SP - 9181 EP - 9209 PB - MDPI CY - Basel AN - OPUS4-26296 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Descalzo López, Ana Belén A1 - Xu, H.-J. A1 - Xue, Z.-L. A1 - Hoffmann, Katrin A1 - Shen, Z. A1 - Weller, Michael G. A1 - You, X.-Z. A1 - Rurack, Knut T1 - Phenanthrene-Fused Boron-Dipyrromethenes as Bright Long-Wavelength Fluorophores N2 - A new class of boron-dipyrromethene (BDP or BODIPY) dyes was obtained by phenanthrene fusion to the β-pyrrole positions, absorbing in the wavelength range of important laser sources. Despite a 'propeller-like' distorted structure in the crystalline state, the chromophore absorbs (log ε ≥ 5) and fluoresces (Φf ≥ 0.8) strongly and can be easily turned into a fluorescence light-up probe. Incorporation into latex beads produces bright and photostable single-dye and Förster Resonance Energy Transfer (FRET) particles for microscopy applications. KW - Fluoreszenz KW - Absorption KW - BODIPY-Farbstoffe KW - Ladungstransfer KW - NIR-Farbstoffe PY - 2008 U6 - https://doi.org/10.1021/ol800271e SN - 1523-7060 SN - 1523-7052 VL - 10 IS - 8 SP - 1581 EP - 1584 PB - American Chemical Society CY - Washington, DC AN - OPUS4-17511 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weller, Michael G. T1 - Schnelle analytische Techniken für Screening und Monitoring KW - Immunsensoren KW - Immunoassays KW - Teststreifen KW - Probenahme PY - 2008 SN - 0939-0065 IS - 2 SP - 24 PB - Gesellschaft Deutscher Chemiker CY - Frankfurt, M. AN - OPUS4-17599 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weller, Michael G. A1 - Knopp, U. A1 - Niessner, R. T1 - Identification of toxicants in complex environmental samples using HPLC combined online with toxicity testing T2 - Anakon 2007 CY - Jena, Germany DA - 2007-03-27 PY - 2007 AN - OPUS4-14737 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Cervino, C. A1 - Knopp, D. A1 - Weller, Michael G. A1 - Niessner, R. T1 - Novel Aflatoxin derivatives and protein conjugates N2 - Aflatoxins, a group of structurally related mycotoxins, are well known for their toxic and carcinogenic effects in humans and animals. Aflatoxin derivatives and protein conjugates are needed for diverse analytical applications. This work describes a reliable and fast synthesis of novel aflatoxin derivatives, purification by preparative HPLC and characterisation by ESI-MS and one- and two-dimensional NMR. Novel aflatoxin bovine serum albumin conjugates were prepared and characterised by UV absorption and MALDI-MS. These aflatoxin protein conjugates are potentially interesting as immunogens for the generation of aflatoxin selective antibodies with novel specificities. KW - Aflatoxin KW - Mycotoxin KW - Hapten KW - Protein conjugation KW - Immunogen KW - Antigen KW - Antibody PY - 2007 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-147572 UR - http://www.mdpi.org/molecules/papers/12030641.pdf UR - http://www.mdpi.org/molecules/papers/12030641sm.pdf SN - 1420-3049 VL - 12 IS - 3 SP - 641 EP - 653 PB - MDPI CY - Basel AN - OPUS4-14757 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Stolper, P. A1 - Fabel, S. A1 - Weller, Michael G. A1 - Knopp, D. A1 - Niessner, R. T1 - Whole-cell luminescence-based flow-through biodetector for toxicity testing N2 - A new type of biodetector was designed based on a bioluminescence test with the bacterium Vibrio fischeri performed in a liquid continuous flow-through system. Here we describe the modification of a commercial tube luminescence detector to work in the flow mode by building a new flow cell holder and a new case including “top cover” to connect the flow cell with the waste and the incubation capillary in a light-proof manner. As different samples were injected successively it was necessary to keep the individual peaks separated. This was done using an air-segmented flow in the reaction coil. To afford fast screening, the incubation time of the sample and the Vibrio fischeri, which equaled the dead time of the detection system, was set at 5.6 min. Rapid monitoring of toxic substances is achieved by using 20 µL of sample and flow-rates of 110–150 µL min-1. As a proof-of-principle, we show results for the detection of five selected di-, tri- and tetrachlorophenols at different concentrations varying from 1 to 200 mg L-1. Calculation of inhibition rates and EC50 values were performed and compared with corresponding values from the DIN EN ISO 11348-2 microplate format. Compared with the latter, the inhibition rates obtained with our flow-through biodetector for the compounds tested were generally about twofold lower, but importantly, a much faster detection is possible. KW - Biosensor KW - Air-segmented flow KW - Vibrio fischeri KW - Bioluminescence KW - Toxicity test PY - 2008 U6 - https://doi.org/10.1007/s00216-007-1770-5 SN - 1618-2642 SN - 1618-2650 VL - 390 IS - 4 SP - 1181 EP - 1187 PB - Springer CY - Berlin AN - OPUS4-17713 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -