TY - JOUR A1 - Enthaler, S. A1 - Krackl, S. A1 - Epping, J.D. A1 - Eckhardt, B. A1 - Weidner, Steffen A1 - Fischer, A. T1 - Iron-based pre-catalyst supported on polyformamidine for C-C bond formation N2 - In the present study the incorporation of iron into an organic polymer, composed of formamidine subunits [R–N=C(H)–NH–R], has been examined. The catalytic ability of the recyclable material was investigated in the iron-catalyzed formation of C–C bonds. After optimization of the reaction conditions, excellent yields and chemoselectivities were feasible. KW - Polyforamidine KW - Synthesis KW - Catalytic ability PY - 2012 DO - https://doi.org/10.1039/c2py00540a SN - 1759-9954 SN - 1759-9962 VL - 3 IS - 3 SP - 751 EP - 756 AN - OPUS4-25461 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Falkenhagen, Jana A1 - Dalgic, Mete-Sungur A1 - Weidner, Steffen T1 - Quantitative MALDI-TOF Mass Spectrometry of Star-Shaped Polylactides Based on Chromatographic Hyphenation N2 - The end groups of three- and four-arm star-shaped polylactides (PLA) with trimethylolpropane and pentaerythritol core structures were functionalized with acetic acid. Reaction products with different degrees of functionalization were analyzed by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Additional gradient elution liquid adsorption chromatography (GELAC) measurements were performed to determine the degree of functionalization. This technique enabled clear separation and sufficient quantification of the formed species. These chromatographic data could be used inversely to quantify mass spectrometric results, which are usually biased by the unknown ionization probabilities of different polymer end group structures. Our results showed that, in this particular case, the peak intensity in the MALDITOF mass spectra can be used to semiquantitatively determine the degree of functionalization in incompletely functionalized multiarm PLA. KW - Polylactides KW - MALDI-TOF-MS KW - Gradient elution liquid adsorption chromatography PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-625292 DO - https://doi.org/10.1021/jasms.4c00491 SN - 1879-1123 SP - 1 EP - 9 PB - American Chemical Society (ACS) AN - OPUS4-62529 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Falkenhagen, Jana A1 - Friedrich, Jörg Florian A1 - Schulz, Günter A1 - Krüger, Ralph-Peter A1 - Much, Helmut A1 - Weidner, Steffen T1 - Liquid Adsorption Chromatography near Critical Conditions of Adsorption coupled with Matrix-assisted Laser Desorption/Ionization Mass Spectrometry N2 - Chemical heterogeneities and molecular weight distributions of poly(ethylene oxide) (PEO)-co-polymethylene (PM) model oligomers, which are relevant to the synthesis of commonly used tensides, were investigated. For analytical characterization, the well-known principle of liquid adsorption chromatography at 'critical conditions' (LACCC) was modified. Near the critical conditions of adsorption of the PEO unit, e.g., at slight adsorption conditions of PM, the copolymers could be separated according to their PM chain length. The eluates were separated and single fractions of each peak were continuously transferred onto the MALDI target by means of a commercially available device. Simultaneously, the MALDI matrix solution was continuously added with a second pump. This procedure offers the possibility of the formation of homogeneous matrix-polymer textures. By MALDI-MS a complete characterization of the chemical composition (PEO and PM chain length) of each peak could be achieved. The obtained MALDI mass spectra of the eluates at different retention times could be used for the molecular weight calibration of the LAC system. In this way, an additional application of SEC, as in conventional 2D-chromatography, was avoided by using the MALDI method as quasi chromatographic separation KW - Liquid adsorption chromatography KW - Matrix-assisted laser desorption KW - Ionization mass spectrometry KW - Coupling methods KW - MALDI PY - 2000 DO - https://doi.org/10.1080/10236660008034644 SN - 1023-666X SN - 1563-5341 VL - 5 SP - 549 EP - 562 PB - Gordon and Breach Publ. CY - Amsterdam AN - OPUS4-2168 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Falkenhagen, Jana A1 - Krüger, Ralph-Peter A1 - Much, Helmut A1 - Schulz, Günter A1 - Weidner, Steffen ED - Grellmann, W. T1 - Characterization and identification of new polymer structures by optimization and coupling of HPLC and MALDI-TOF-MS T2 - Polymerwerkstoffe 2000 CY - Halle (Saale), Germany DA - 2000-09-25 PY - 2000 SN - 3-86010-605-8 PB - Martin-Luther-Univ. CY - Halle AN - OPUS4-2250 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Falkenhagen, Jana A1 - Krüger, Ralph-Peter A1 - Schulz, Günter A1 - Weidner, Steffen T1 - Polymer Characterization by LC / MALDI-MS Coupling T2 - Vortragstagung "Funktionspolymere für Systemlösungen" CY - Darmstadt, Germany DA - 2002-03-18 PY - 2002 AN - OPUS4-1805 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Falkenhagen, Jana A1 - Krüger, Ralph-Peter A1 - Schulz, Günter A1 - Weidner, Steffen T1 - Polymer characterization by LC / MALDI-MS coupling T2 - Bayreuther Polymer Symposium 2001 CY - Bayreuth, Germany DA - 2001-09-16 PY - 2001 CY - Bayreuth AN - OPUS4-2256 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Falkenhagen, Jana A1 - Weidner, Steffen T1 - Detection limits of matrix-assisted laser desorption/ionisation mass spectrometry coupled to chromatography - a new application of solvent-free sample preparation N2 - The detection limits of matrix-assisted laser desorption/ionisation mass spectrometry (MALDI-MS) by semi-online coupling with chromatography were investigated using various mixtures of polyethylene oxides (PEOs) with different end groups. In contrast to the common dried-droplet sample preparation technique, which results in an inhomogeneous sample-to-matrix ratio within the MALDI spot, the used coupling technique offers a very high reproducibility combined with surpassing sensitivity of a few femtograms over a broad range of sample-to-matrix ratios. These results are in correlation with the results of the recently established solvent-free MALDI-TOFMS method utilising the grinding approach and are also of assistance towards the more theoretical aspect of MALDI that suggests that there is no necessity for an analyte incorporation into a matrix crystal for excellent matrix-assistance. PY - 2005 DO - https://doi.org/10.1002/rcm.2256 SN - 0951-4198 SN - 1097-0231 VL - 19 IS - 24 SP - 3724 EP - 3730 PB - Wiley CY - Chichester AN - OPUS4-11859 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Falkenhagen, Jana A1 - Weidner, Steffen T1 - Determination of critical conditions of adsorption for chromatography of polymers N2 - Liquid chromatography (LC) at critical conditions of adsorption was used to separate various poly(ethylene oxides), poly(propylene oxides) and their copolymers. For the first time, the determination of the critical conditions by means of Ultra Performance Liquid Chromatography (UPLC) coupled to Electrospray Ionization Time-of-flight Mass Spectrometry (ESI-TOF MS) is reported. In contrast to established, mostly laborious routines to find suitable chromatographic separation conditions, this coupling enables a very fast adjustment of parameters. Similar to LC Matrix-assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (LC/MALDI MS) coupling, a two-dimensional analysis of homo- and copolymers regarding its functionality type and molecular weight distribution, as well as copolymer composition, can be performed simultaneously. Furthermore, there is no need for using polymer standards for the determination of critical conditions or Size Exclusion Chromatography calibration. KW - Polymere KW - UPLC KW - ESI-Massenspektrometrie KW - Kopplung PY - 2009 DO - https://doi.org/10.1021/ac8019784 SN - 0003-2700 SN - 1520-6882 VL - 81 IS - 1 SP - 282 EP - 287 PB - American Chemical Society CY - Washington, DC AN - OPUS4-19619 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Falkenhagen, Jana A1 - Weidner, Steffen ED - Barner-Kowollik, C. ED - Gründling, T. ED - Falkenhagen, Jana ED - Weidner, S. T1 - Hyphenated techniques KW - MALDI KW - Chromatography KW - Coupling techniques PY - 2012 SN - 978-3-527-32924-3 SP - 209 EP - 235 PB - Wiley-VCH Verlag GmbH & Co. KGaA AN - OPUS4-26395 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fandrich, Nick A1 - Falkenhagen, Jana A1 - Weidner, Steffen A1 - Pfeifer, Dietmar A1 - Staal, B. A1 - Thünemann, Andreas A1 - Laschewsky, A. T1 - Characterization of new amphiphilic block copolymers of N-vinyl pyrrolidone and vinyl acetate, 1 - analysis of copolymer composition, end groups, molar masses and molar mass distributions N2 - New amphiphilic block copolymers consisting of N-vinyl pyrrolidone and vinyl acetate were synthesized via controlled radical polymerization using a reversible addition/fragmentation chain transfer (RAFT)/macromolecular design via the interchange of xanthates (MADIX) system. The synthesis was carried out in 1,4-dioxane as process solvent. In order to get conclusions on the mechanism of the polymerization the molecular structure of formed copolymers was analysed by means of different analytical techniques. 13C NMR spectroscopy was used for the determination of the monomer ratios. End groups were analysed by means of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. This technique was also used to determine possible fragmentations of the RAFT end groups. By means of a combination of size exclusion chromatography, 13C NMR and static light scattering molar mass distributions and absolute molar masses could be analysed. The results clearly show a non-ideal RAFT mechanism. KW - Amphiphiles KW - Block copolymers KW - Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOF MS) KW - N-vinyl pyrrolidone KW - Reversible addition/fragmentation chain transfer (RAFT) PY - 2010 DO - https://doi.org/10.1002/macp.200900466 SN - 1022-1352 SN - 1521-3935 VL - 211 IS - 8 SP - 869 EP - 878 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-21905 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fandrich, Nick A1 - Falkenhagen, Jana A1 - Weidner, Steffen A1 - Staal, B. A1 - Thünemann, Andreas A1 - Laschewsky, A. T1 - Characterization of new amphiphilic block copolymers of N-vinylpyrrolidone and vinyl acetate, 2 - chromatographic separation and analysis by MALDI-TOF and FT-IR coupling N2 - PVP-block-PVAc block copolymers were synthesized by controlled radical polymerization applying a RAFT/MADIX system and were investigated by HPLC and by coupling of chromatography to FT-IR spectroscopy and MALDI-TOF MS. Chromatographic methods (LACCC and gradient techniques) were developed that allowed a separation of block copolymers according to their repeating units. The results of the spectroscopic and spectrometric analysis clearly showed transfer between radicals and process solvent. With the use of hyphenated techniques differences between main and side products were detected. In agreement with previously published results, obtained by NMR, SEC, static light scattering and MALDI-TOF MS, our data proved a non-ideal RAFT polymerization. KW - Amphiphiles KW - Block copolymers KW - Liquid chromatography KW - MALDI KW - Reversible addition fragmentation chain transfer (RAFT) KW - Liquid adsorption chromatography at critical conditions KW - Gradient chromatography KW - MALDI-TOF mass spectrometry KW - Hyphenated techniques KW - Mechanism of polymerization PY - 2010 DO - https://doi.org/10.1002/macp.201000044 SN - 1022-1352 SN - 1521-3935 VL - 211 IS - 15 SP - 1678 EP - 1688 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-22012 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fischer, J.L. A1 - Lutomski, C.A. A1 - El-Baba, T.J. A1 - Siriwardena-Mahanama, B.N. A1 - Weidner, Steffen A1 - Falkenhagen, Jana A1 - Allen, M. J. A1 - Trimpin, S. T1 - Matrix-assisted ionization-ion mobility spectrometry-mass spectrometry: Selective analysis of a europium-PEG complex in a crude mixture N2 - The analytical utility of a new and simple to use ionization method, matrix-assisted ionization (MAI), coupled with ion mobility spectrometry (IMS) and mass spectrometry (MS) is used to characterize a 2-armed europium(III)-containing poly(ethylene glycol) (Eu-PEG) complex directly from a crude sample. MAI was used with the matrix 1,2-dicyanobenzene, which affords low chemical background relative to matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI). MAI provides high ion abundance of desired products in comparison to ESI and MALDI. Inductively coupled plasma-MS measurements were used to estimate a maximum of 10% of the crude sample by mass was the 2-arm Eu-PEG complex, supporting evidence of selective ionization of Eu-PEG complexes using the new MAI matrix, 1,2-dicyanobenzene. Multiply charged ions formed in MAI enhance the IMS gas-phase separation, especially relative to the singly charged ions observed with MALDI. Individual components are cleanly separated and readily identified, allowing characterization of the 2-arm Eu-PEG conjugate from a mixture of the 1-arm Eu-PEG complex and unreacted starting materials. Size-exclusion chromatography, liquid chromatography at critical conditions, MALDI-MS, ESI-MS, and ESI-IMS-MS had difficulties with this analysis, or failed. KW - Matrix-assisted ionization ion mobility spectrometry mass spectrometry KW - Europium KW - Poly(ethylene glycol) KW - Size-exclusion chromatography KW - Liquid chromatography at critical conditions KW - Electrospray ionization KW - Matrix-assisted laser desorption/ionization KW - Inductively coupled plasma-mass spectrometry KW - ESI KW - MALDI KW - SEC PY - 2015 DO - https://doi.org/10.1007/s13361-015-1233-8 SN - 1044-0305 VL - 26 IS - 12 SP - 2086 EP - 2095 PB - Elsevier CY - New York, NY AN - OPUS4-35283 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Friedrich, Jörg Florian A1 - Gerstung, Vanessa A1 - Mix, Renate A1 - Kühn, Gerhard A1 - Weidner, Steffen ED - d'Agostino, R. T1 - Pulsed plasma initiated homo- and copolymerisation - molar masses T2 - 16th International Symposium on Plasma Chemistry (ISPC-16) CY - Taormina, Italy DA - 2003-06-22 PY - 2003 IS - CD-ROM PB - Dep. of Chemistry, Univ. CY - Bari AN - OPUS4-2710 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Friedrich, Jörg Florian A1 - Ghode, Archana A1 - Kühn, Gerhard A1 - Weidner, Steffen A1 - Geng, Shiming A1 - Retzko, Iris A1 - Unger, Wolfgang A1 - Lippitz, Andreas ED - Schindel-Bidinelli, E. T1 - Polymeroberflächenfunktionalisierungen im gepulsten Plasma mit nachfolgender chemischer Behandlung T2 - 14. Internationales Symposium Swissbonding ; 14. Internationaler Kongreß Swiss Bonding ; 14th Swiss Bonding 00 CY - Rapperswil, Schweiz DA - 2000-05-16 PY - 2000 SP - 31 EP - 44 PB - SWIBOTECH GmbH CY - Bülach AN - OPUS4-6980 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Friedrich, Jörg Florian A1 - Kühn, Gerhard A1 - Mix, Renate A1 - Retzko, Iris A1 - Gerstung, Vanessa A1 - Weidner, Steffen A1 - Schulze, Rolf-Dieter A1 - Unger, Wolfgang ED - Mittal, K. L. T1 - Plasma polymer adhesion promoters for metal-polymer systems T2 - 2nd International Symposium on Polyimides and Other High Temperature Polymers: Synthesis, Characterization and Applications CY - Newark, NJ, USA DA - 2001-12-03 KW - r.f. pulsed plasma KW - Plasma polymers with functional groups KW - Copolymers KW - Adhesion promoting interlayers KW - Metal-polymer systems PY - 2003 SN - 90-6764-378-5 VL - 2 SP - 359 EP - 388 PB - VSP CY - Utrecht AN - OPUS4-6967 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Friedrich, Jörg Florian A1 - Schulz, Eckhard A1 - Weidner, Steffen A1 - Kühn, Gerhard T1 - Verbesserungen der mechanischen Festigkeiten von Faser-Polymer-Verbundwerkstoffen durch Vorbehandlung der Fasern im Niederdruckplasma T2 - Vortragsbände des 8. Internationalen Techtextil-Symposiums 1997 CY - Frankfurt am Main, Deutschland DA - 1997-05-12 PY - 1997 VL - 8 SP - 1(?) EP - 16(?) PB - Messe Frankfurt CY - Frankfurt am Main AN - OPUS4-7287 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Friedrich, Jörg Florian A1 - Schulz, Eckhard A1 - Weidner, Steffen A1 - Kühn, Gerhard T1 - Improvement in Mechanical Strength of Fibre Polymer Composites by Fibre Pretreatment in Low-Pressure Plasmas T2 - Vortragsbände des 8. Internationalen Techtextil-Symposiums 1997 CY - Frankfurt am Main, Deutschland DA - 1997-05-12 PY - 1997 SP - 1(?) EP - 16(?) PB - Messe Frankfurt CY - Frankfurt am Main AN - OPUS4-7286 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Friedrich, Jörg Florian A1 - Unger, Wolfgang A1 - Lippitz, Andreas A1 - Geng, Sh. A1 - Koprinarov, Ivaylo A1 - Kühn, Gerhard A1 - Weidner, Steffen T1 - Modelling plasma-induced reactions on polymer surfaces using aliphatic self-assembling and LB layers PY - 1998 SN - 0257-8972 VL - 98 SP - 1132 EP - 1141 PB - Elsevier Science CY - Lausanne AN - OPUS4-6999 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Friedrich, Jörg Florian A1 - Unger, Wolfgang A1 - Lippitz, Andreas A1 - Giebler, Rainer A1 - Koprinarov, Ivaylo A1 - Weidner, Steffen A1 - Kühn, Gerhard ED - Mittal, K. L. T1 - Significance of interfacial redox reactions and formation of metal-organic complexes for the adhesion of metals on pristine and plasma-treated polymers KW - Oxygen low-pressure plasma treatment of polymers KW - Metal-polymer interactions KW - Peel strength PY - 2000 SN - 90-6764-327-0 VL - 2 SP - 137 EP - 171 PB - VSP CY - Utrecht AN - OPUS4-6979 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Friedrich, Jörg Florian A1 - Unger, Wolfgang A1 - Lippitz, Andreas A1 - Koprinarov, Ivaylo A1 - Kühn, Gerhard A1 - Weidner, Steffen A1 - Vogel, Lydia T1 - Chemical reactions at polymer surfaces interacting with a gas plasma or with metal atoms - their relevance to adhesion N2 - The chemical and morphological stabilities of polymer segments in the near-surface layer were investigated by spectroscopic methods such as X-ray photoelectron spectroscopy and near-edge X-ray absorption fine structure spectroscopy. Model studies were undertaken with Langmuir–Blodgett films, self-assembled monolayers and oligomer films. For thin polymer layers (30 to 500 nm), the changes in molecular-weight distributions of some polymers were investigated systematically by size exclusion chromatography, matrix-assisted laser desorption/ionization–time-of-flight mass spectrometry and thermal-field flow fractionation for oxygen- and helium-plasma exposures. The polymer surfaces were found to be relatively stable at exposure to an oxygen low-pressure plasma up to ca. 2 s. This is important information to get maximum adhesion to metals in composites. In correlation to their redox potentials, potassium, aluminium and chromium react with oxygen functional groups at the polymer/metal interface. In a dedicated study, chromium was found to attack aromatic rings and form different reaction products. PY - 1999 DO - https://doi.org/10.1016/S0257-8972(99)00229-7 SN - 0257-8972 VL - 116-119 SP - 772 EP - 782 PB - Elsevier Science CY - Lausanne AN - OPUS4-6981 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Friedrich, Jörg Florian A1 - Unger, Wolfgang A1 - Lippitz, Andreas A1 - Koprinarov, Ivaylo A1 - Kühn, Gerhard A1 - Weidner, Steffen A1 - Vogel, Lydia ED - Mittal, K. T1 - Plasma Pretreatment of Polymer Surfaces - Relevance to Adhesion of Metals T2 - 5th Symposium on Metallized Plastics ; 6th Symposium on Metallized Plastics CY - Los Angeles, CA, USA DA - 1996-05-05 PY - 1998 SN - 90-6764-290-8 SP - 271 EP - 293 PB - VSP CY - Utrecht AN - OPUS4-6987 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Friedrich, Jörg Florian A1 - Unger, Wolfgang A1 - Lippitz, Andreas A1 - Koprinarov, Ivaylo A1 - Weidner, Steffen A1 - Kühn, Gerhard ED - Schindel-Bidinelli, E. T1 - Umweltfreundliches Metallisieren von Kunststoffen durch Plasmavorbehandlung in einem geschlossenen Reaktor T2 - Swissbonding 97 ; 11. Internationales Symposium Klebtechnik und Umwelt ; 11th International Symposium Bonding and Sealing Technology CY - Rapperswil, Schweiz DA - 1997-05-26 PY - 1997 SP - 1(?) EP - 3(?) PB - SWIBOTECH CY - Rorbas AN - OPUS4-6994 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Friedrich, Jörg Florian A1 - Unger, Wolfgang A1 - Lippitz, Andreas A1 - Koprinarov, Ivaylo A1 - Weidner, Steffen A1 - Kühn, Gerhard ED - Nowack, H. T1 - Wechselwirkungen zwischen plasmamodifizierten Polymeroberflächen und Metallen T2 - 5. Internationale Fachtagung - ND-Plasma-Technologie CY - Duisburg, Deutschland DA - 1997-09-22 PY - 1997 VL - 5 SP - 1(?) EP - 17(?) PB - Print-Service CY - Mülheim AN - OPUS4-6995 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Friedrich, Jörg Florian A1 - Unger, Wolfgang A1 - Lippitz, Andreas A1 - Weidner, Steffen A1 - Geng, Sh. A1 - Wigant, L. A1 - Wöll, Ch. A1 - Erdmann, J. A1 - Gorsler, H.-V. T1 - Characterization of plasma-modified organic surfaces by electron spectroscopy, SEIRA, and MALDI-TOF-MS T2 - 6th European Conference on Applications of Surface and Interface Analysis CY - Montreux, Switzerland DA - 1995-10-09 PY - 1995 SP - TC 11 PB - Wiley CY - Chichester AN - OPUS4-7001 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Friedrich, Jörg Florian A1 - Wigant, L. A1 - Unger, Wolfgang A1 - Lippitz, Andreas A1 - Weidner, Steffen A1 - Kühn, Gerhard A1 - Geng, Sh. A1 - Erdmann, J. A1 - Gorsler, H.-V. T1 - Plasmavorbehandlungen von Polymeroberflächen T2 - 2. Freiberger Polymertag CY - Freiberg DA - 1995-05-30 PY - 1995 SP - 17 Seiten CY - Freiberg AN - OPUS4-7014 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gabriel, Stefan A1 - Pfeifer, Dietmar A1 - Schwarzinger, C. A1 - Panne, Ulrich A1 - Weidner, Steffen T1 - Matrix-assisted laser desorption/ionization time-of-flight mass spectrometric imaging of synthetic polymer sample spots prepared using ionic liquid matrices N2 - RATIONALE Polymer sample spots for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) prepared by the dried-droplet method often reveal ring formation accompanied by possible segregation of matrix and sample molecules as well as of the polymer homologs itself. Since the majority of sample spots are prepared by this simple and fast method, a matrix or sample preparation method that excludes such segregation has to be found. METHODS Three different ionic liquid matrices based on conventionally used aromatic compounds for MALDI-TOF MS were prepared. The formation of ionic liquids was proven by 1H NMR spectroscopy. MALDI-Imaging mass spectrometry was applied to monitor the homogeneity. RESULTS Our results show a superior sample spot homogeneity using ionic liquid matrices. Spots could be sampled several times without visible differences in the mass spectra. A frequently observed loss of matrix in the mass spectrometer vacuum was not observed. The necessary laser irradiance was reduced, which resulted in less polymer fragmentation. CONCLUSIONS Ionic liquid matrices can be used to overcome segregation, a typical drawback of conventional MALDI dried-droplet preparations. Homogeneous sample spots are easy to prepare, stable in the MS vacuum and, thereby, improve the reproducibility of MALDI. PY - 2014 DO - https://doi.org/10.1002/rcm.6810 SN - 0951-4198 SN - 1097-0231 VL - 28 IS - 5 SP - 489 EP - 498 PB - Wiley CY - Chichester AN - OPUS4-30267 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gabriel, Stefan A1 - Schwarzinger, C. A1 - Schwarzinger, B. A1 - Panne, Ulrich A1 - Weidner, Steffen T1 - Matrix segregation as the major cause for sample inhomogeneity in MALDI dried droplet spots N2 - The segregation in dried droplet MALDI sample spots was analyzed with regard to the matrix-to-sample ratio using optical microscopy, MALDI imaging mass spectrometry (MALDI MSI) and IR imaging spectroscopy. In this context, different polymer/matrix/solvent systems usually applied in the analysis of synthetic polymers were investigated. The use of typical matrix concentrations (10 mg mL-1) in almost every case resulted in ring patterns, whereas higher concentrated matrix solutions always led to homogeneous sample spot layers. The data revealed that segregation is predominantly caused by matrix transport in the drying droplet, whereas polymer segregation seems to be only secondary. KW - MALDI KW - Imaging MS KW - Matrix segregation KW - Dried droplet KW - Sample preparation KW - Polymers PY - 2014 DO - https://doi.org/10.1007/s13361-014-0913-0 SN - 1044-0305 VL - 25 IS - 8 SP - 1356 EP - 1363 PB - American Society for Mass Spectrometry CY - New York, NY AN - OPUS4-32582 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gabriel, Stefan A1 - Steinhoff, R.F. A1 - Pabst, M. A1 - Schwarzinger, C. A1 - Zenobi, R. A1 - Panne, Ulrich A1 - Weidner, Steffen T1 - Improved analysis of ultra-high molecular mass polystyrenes in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using DCTB matrix and caesium salts N2 - Rationale The ionization of polystyrenes in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is typically achieved by the use of silver salts. Since silver salts can cause severe problems, such as cluster formation, fragmentation of polymer chains and end group cleavage, their substitution by alkali salts is highly desirable. Methods The influence of various cations (Ag+, Cs+ and Rb+) on the MALDI process of polystyrene (PS) mixtures and high mass polystyrenes was examined. The sample preparation was kept as straightforward as possible. Consequently, no recrystallization or other cleaning procedures were applied. Results The investigation of a polystyrene mixture showed that higher molecular polystyrenes could be more easily ionized using caesium, rather than rubidium or silver salts. In combination with the use of DCTB as matrix a high-mass polymer analysis could be achieved, which was demonstrated by the detection of a 1.1 MDa PS. Conclusions A fast, simple and robust MALDI sample preparation method for the analysis of ultra-high molecular weight polystyrenes based on the use of DCTB and caesium salts has been presented. The suitability of the presented method has been validated by using different mass spectrometers and detectors. KW - MALDI KW - Mega-dalton KW - Ionization KW - Caesium KW - Polystyrene KW - DCTB PY - 2015 UR - http://onlinelibrary.wiley.com/doi/10.1002/rcm.7197/full DO - https://doi.org/10.1002/rcm.7197 SN - 0951-4198 SN - 1097-0231 VL - 29 IS - 11 SP - 1039 EP - 1046 PB - Wiley CY - Chichester AN - OPUS4-33191 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Garaleh, M. A1 - Kricheldorf, H.R. A1 - Weidner, Steffen A1 - Yashiro, T. T1 - Hafnium chloride catalyzed polycondensation of Alpha, Omega-alkanediol with dicarboxylic acids or succinic anhydride KW - Polyester KW - Polycondensation KW - Hafnium KW - Cyclization PY - 2010 DO - https://doi.org/10.1080/10601320903539199 SN - 1060-1325 SN - 1520-5738 VL - 47 IS - 4 SP - 303 EP - 308 PB - Taylor & Francis CY - Philadelphia, PA AN - OPUS4-22953 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Garaleh, M. A1 - Lahcini, M. A1 - Kricheldorf, H.R. A1 - Weidner, Steffen T1 - Syntheses of aliphatic polyesters catalyzed by lanthanide triflates N2 - Polycondensations of 1,6-hexane diol and sebacic acid were conducted in bulk with addition of a lanthanide triflate as acidic catalyst. With exception of promethium triflate all lanthanide triflates were studied. A particularly low molecular weight was obtained with neodym triflate and the best results with samarium triflate. With Sm(OTf)3 weight average (Mw) values up to 65 kDa (uncorrected SEC data) were achieved after optimization of the reaction conditions. Comparison of these results with those obtained from bismuth, magnesium, and zinc triflates, on the one hand, and comparison with the acidities of all catalysts, on the other, indicates that the esterification mechanism involves complexation of monomer by metal ions. Preparation of multiblock copoly(ether ester)s failed due to insufficient incorporation of poly(tetrahydrofuran) diols. KW - Biodegradable polyesters KW - Lanthanide ions KW - Macrocycles KW - MALDI-TOF KW - Polycondensation PY - 2009 DO - https://doi.org/10.1002/pola.23136 SN - 0360-6376 SN - 0887-624X VL - 47 IS - 1 SP - 170 EP - 177 PB - Wiley CY - Hoboken, NJ AN - OPUS4-19626 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gille, M. A1 - Viertel, A. A1 - Weidner, Steffen A1 - Hecht, S. T1 - Modular synthesis of monomers for on-surface polymerization to graphene architectures N2 - We developed a modular synthesis of halogenated polycyclic aromatic monomers for on-surface polymerization to generate graphene wires, ribbons, and networks. KW - Graphene monomers KW - Graphene nanoribbons KW - Functionalized graphene nanoribbons KW - Graphene wires KW - Hexabenzocoronene KW - On-surface polymerization PY - 2013 DO - https://doi.org/10.1055/s-0032-1317959 SN - 0936-5214 SN - 1437-2096 VL - 24 IS - 2 SP - 0259 EP - 0263 PB - Thieme CY - Stuttgart AN - OPUS4-27621 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gonzalez-Rojano, N. A1 - Arias-Marin, E. A1 - Navarro-Rodriguez, D. A1 - Weidner, Steffen T1 - Bidirectional Synthesis of a Series of 2,5- Dodecanoy-phenylene-ethynylene oligomers N2 - A family of rigid rod like 2,5-dodecanoxy-phenyleneethynylene oligomers having 3, 5, 7, and 9 repeating units was selectively synthesized by a bi-directional iterative divergent-convergent approach. Starting from a central 1,4-bis(dodecanoxy)-2,5-diiodobenzene monomer, only two repetitive reactions were involved with each cycle of oligomerization: a Pd/Cu cross-coupling with the bifunctional monomer 1-(3,3-diethyltriazene)-2,5-bis(dodecanoxy)-4-(ethynyl)benzene, generating oligomers with terminal triazene groups, followed by a further nucleophilic substitution with iodine. KW - Conjugated oligomers KW - Phenyleneethynylenes KW - Tri­azenes KW - Aryl iodides KW - Sonoga PY - 2005 DO - https://doi.org/10.1055/s-2005-868474 SN - 0936-5214 SN - 1437-2096 IS - 8 SP - 1259 EP - 1262 PB - Thieme CY - Stuttgart AN - OPUS4-11100 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Grabicki, N. A1 - Nguyen, K. T. G. A1 - Weidner, Steffen A1 - Dumele, O. T1 - Confined Spaces in [n]Cyclo-2,7-pyrenylenes N2 - A set of strained aromatic macrocycles based on [n]cyclo2,7-(4,5,9,10-tetrahydro)pyrenylenes is presented with size dependent photophysical properties. The K-region of pyrene was functionalized with ethylene glycol groups to decorate the outer rim and thereby confine the space inside the macrocycle. This confined space is especially pronounced for n = 5, which leads to an internal binding of up to 8.0×104 M–1 between the ether-decorated [5]cyclo-2,7-pyrenylene and shape complementary crown ether–cation complexes. Both, the ether-decorated [n]cyclo-pyrenylenes as well as one of their host–guest complexes have been structurally characterized by single crystal X-ray analysis. In combination with computational methods the structural and thermodynamic reasons for the exceptionally strong binding have been elucidated. The presented rim confinement strategy makes cycloparaphenylenes an attractive supramolecular host family with a favorable, size-independent read-out signature and binding capabilities extending beyond fullerene guests. KW - Cycloparaphenylenes KW - Host–guest systems KW - Macrocycles KW - Molecular recognition KW - Supramolecular chemistry PY - 2021 DO - https://doi.org/10.1002/anie.202102809 SN - 1433-7851 VL - 60 IS - 27 SP - 1 EP - 7 PB - Wiley VCH AN - OPUS4-52517 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gross, J.H. A1 - Weidner, Steffen T1 - Influence of Electric Field Strength and Emitter Temperature on Field Desorption Mass Spectra of Polyethylene Oligomers N2 - The influence of electric field strength and emitter temperature on dehydrogenation and C–C cleavage in field desorption (FD) mass spectrometry of polyethylene (PE) oligomers of average molecular weights ranging from 500 to 2000 is examined. Low mass oligomers yield molecular weight (MW) distributions that are basically in accordance with results from gel-permeation chromatography. For these materials, dehydrogenation can be greatly reduced by reduction of the emitter potential. Furthermore, the influence of emitter potential on MW distributions indicates the occurrence of field-induced C–C cleavages. Reliable MW distributions are more difficult to obtain from higher mass oligomers by FD-MS because of the need for higher field strength and higher emitter temperatures to effect their desorption/ionization. Experiments reveal that the application of FD-MS to PE oligomers is limited not only by field-induced but also by thermally-induced fragmentations. Even then, FD mass spectra contain valuable information on mass range and homogeneity of PE samples up to about m/z 3600. PY - 2000 DO - https://doi.org/10.1255/ejms.300 SN - 1469-0667 SN - 1356-1049 SN - 1365-0718 IS - 6 SP - 11 EP - 17 PB - IM Publications CY - Chichester AN - OPUS4-11098 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gruendling, T. A1 - Weidner, Steffen A1 - Falkenhagen, Jana A1 - Barner-Kowollik, C. T1 - Mass spectrometry in polymer chemistry: a state-of-the-art up-date N2 - Two decades after the introduction of matrix assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI), soft ionization mass spectrometry represents a powerful toolset for the structural investigation of synthetic polymers. The present review highlights the current state-of-the-art, covering the latest developments of novel techniques, enabling instrumentation as well as the important applications of soft ionization MS from the beginning of 2008. Special attention is paid to the role that soft ionization MS has played in the mechanistic investigation of radical polymerization processes since 2005. KW - Polymerization mechanisms KW - Mass spectrometry KW - LC-MS coupling PY - 2010 DO - https://doi.org/10.1039/b9py00347a SN - 1759-9954 SN - 1759-9962 VL - 1 IS - 5 SP - 599 EP - 617 AN - OPUS4-21906 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hoskins, Jessica A1 - Falkenhagen, Jana A1 - Weidner, Steffen ED - Udomkichdecha, W. ED - Böllinghaus, Thomas ED - Manonukul, A. ED - Lexow, J. T1 - Characterization of randomly branched polymers utilizing liquid chromatography and mass spectrometry N2 - Branching in polymers is an important way to modify the materials properties, however the characterization of random branching in polymeric materials is a challenge in polymer analysis. In this work, liquid adsorption chromatography methods are developed for a commercially available hyperbranched polyester (Boltorn™). This Chromatographie techniques was then coupled to offline MALDI-TOF MS analysis, a first in the analysis of randomly branched polymers. The coupling of these two techniques provides superior MALDI-TOF spectra, enabling the easy identification of structural subdistributons based on theoretical molecular weight. Detailed analysis of the MALDI-TOF spectra shows that these Chromatographie conditions separate cyclic Boltorn polymers (with no core molecule) from non-cyclic polymers (with core molecule), and these are the only two architectures observed. MALDI MS also confirms that the Chromatographie Separation mode is adsorption, but further analysis is needed to determine if there is a Separation by degree of branching. KW - Hyperbranched polyesters KW - Polymer mass spectrometry KW - Polymer chromatography KW - Liquid adsorption chromatography KW - MALDI-TOF MS KW - Carbon capture KW - Climate change KW - Lubricant KW - Micro manufacturing KW - Multiphysics simulations KW - WMRIF PY - 2014 SN - 978-3-319-11339-5 SN - 978-3-319-11340-1 SP - 1 EP - 10 PB - Springer AN - OPUS4-32519 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Jlalia, I. A1 - Chabbah, T. A1 - Chatti, S. A1 - Schiets, F. A1 - Casabianca, H. A1 - Marestin, C. A1 - Mercier, R. A1 - Weidner, Steffen A1 - Kricheldorf, H. R. A1 - Errachid, A. A1 - Vulliet, E. A1 - Hammani, M. A1 - Jaffrezic-Renault, N. T1 - Alternating bio-based pyridinic copolymers modified with hydrophilic and hydrophobic spacers as sorbents of aromatic pollutants N2 - The main objective of this work was to design new advanced sorbent phases, alternating copolymers, derived from isosorbide and 2,6-difluorpyridine, to be used for the removal of aromatic organic pollutants present in water at low concentrations. Six different monomers, dianhydrohexitols isomers and bisphenol derivatives, weresynthesized in order to make it possible to study their hydrophilic and hydrophobiceffect on the sorption efficiency of the resulting polymeric phases. Before this study, we have confirmed the chemicals structures, molecular weights, and thermal properties of the obtained polymeric phases. Sorption results show a higher adsorption efficiency of P6 co-poly(ether-pyridine) based on bisphenol substituted with pyridineunits, for all tested pollutants, hydrophobic and hydrophilic ones, due to its less compact structure. Two aromatic organic pollutants, p-hydroxybenzoic acid and toluicacid, were selected as sorbates to study the adsorption characteristic, kinetics and isotherms of the copoly(ether pyridine) P6. Langmuir model led to a better fitting of the sorption isotherms; the sorption of toluic acid is easier than of that p-hydroxybenzoic acid. Comparing 1/n values for benzoic acid was two time lower for P6 compared to that for biochar and for crosslinked methacrylate resin, showing a higher efficiency KW - Alternating co-poly(ether pyridine)s KW - Aromatic organic compounds, KW - Biosourced isosorbide KW - Sorption isotherm KW - Sorption mechanism PY - 2021 DO - https://doi.org/10.1002/pat.5578 VL - 33 IS - 4 SP - 1057 EP - 1068 PB - Wiley Online Library AN - OPUS4-54031 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Jlalia, I. A1 - Gomri, M. A1 - Chabbah, T. A1 - Chatti, S. A1 - Weidner, Steffen A1 - Abderrazak, H. A1 - Marestin, C. A1 - Mercier, R. A1 - Ben Halima, H. A1 - Lakard, B. A1 - Jaffrezic Renault, N. T1 - Design of Fluorinated Poly(Ether-Pyridine) Films for Impedimetric Detection of Heavy Metal Ions N2 - A series of fluorinated poly(ether-pyridine)s were synthesized via polycondensation of bis-perfluoropyridine with either bisphe-nol A (BPA) or isosorbide, a bio-sourced diol. The polymers were characterized using 1 H and 19 F NMR spectroscopy, and their molecular weights were determined using GPC. Thermal properties were assessed using thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC). The presence of isosorbide in polymer P2 increases the glass transition temperature and results in a lower molecular weight and a higher hydrophilicity. On the other hand, polymer P3, based on BPA, shows the best thermal stability, the highest molecular weight, and the most pronounced hydrophobic character. Electrochemical impedance spectroscopy (EIS) was used to evaluate the modified gold electrodes for the selective detection of metal ions. Among the four target ions (Ni 2+, Cd 2+, Pb2+, and Hg 2+), defined by the European Water Framework Directive, Pb2+ was selectively detected on the hydrophilic polymer P2, while Cd 2+ was selectively detected on the hydrophobic polymer P3. The achieved detection limits were 5 × 10−11 M, corresponding to 10 ng/L for Pb2+ and 5.6 ng/L for Cd 2+, respectively. KW - Cadmium KW - Electrochemical impedance spectroscopy KW - Fluorinated polyether pyridines KW - Isosorbide KW - Lead PY - 2025 DO - https://doi.org/10.1002/pat.70038 SN - 1099-1581 VL - 36 IS - 1 SP - 1 EP - 14 PB - John Wiley & Sons Ltd. AN - OPUS4-62384 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Just, Ulrich A1 - Weidner, Steffen A1 - Kilz, P. A1 - Hofe, T. T1 - Polymer Reference Materials: Round-Robin Tests for the Determination of Molar Masses N2 - This article reports round-robin tests dealing with static light scattering (LS), size exclusion chromatography (SEC), and viscometry measurements of 10 reference materials of various polymer classes: poly(styrene)s (PS), poly(methyl methacrylate)s (PMMA), poly(ethylene oxide)s (PEO), and poly(lactide)s (PLA). In the certificates, molar masses and intrinsic viscosities as well as their uncertainties are specified. Additional values from nuclear magnetic resonance (NMR), infrared spectroscopy (IR), differential scanning calorimetry (DSC), melt flow index (MFR), and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS), which were determined exclusively in BAM laboratories are given, as well. These results represent the base for the BAM certification work of creating polymer reference materials according to the BAM Guidelines for the Production and Certification of BAM Reference Materials, a version of the European guidelines (BCR/01/97). These samples are available for third-party user. KW - Polymer reference materials KW - CRM KW - Molar mass determination KW - Intrinsic viscosity KW - Light scattering (LS) KW - Size exclusion chromatography (SEC) PY - 2005 DO - https://doi.org/10.1080/10236660500418039 SN - 1023-666X SN - 1563-5341 VL - 10 IS - 3-4 SP - 225 EP - 243 PB - Gordon and Breach Publ. CY - Amsterdam AN - OPUS4-11815 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Just, Ulrich A1 - Weidner, Steffen A1 - Wittke, Wolfgang A1 - Friedrich, Jörg Florian A1 - Rittig, F. A1 - Gruber, F. T1 - 2D-Characterization of Polyamides using Chromatography and MALDI-TOF-MS T2 - Waters International GPC 2003 and ISPAC-16-Symposium CY - Baltimore, MD, USA DA - 2003-06-09 PY - 2003 AN - OPUS4-2631 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Just, Ulrich A1 - Werthmann, Barbara A1 - Weidner, Steffen T1 - Referenzmaterialien für die Polymeranalytik - Verfahren zur Charakterisierung und Bewertung PY - 1998 SN - 0943-6677 VL - 49 IS - 6 SP - 223 EP - 228 PB - Rubikon CY - Gaiberg bei Heidelberg AN - OPUS4-11261 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Knappe, Patrick A1 - Bienert, Ralf A1 - Weidner, Steffen A1 - Thünemann, Andreas T1 - Poly(acrylic acid): A combined analysis with field-flow fractionation and SAXS N2 - Polyelectrolytes such as PAA and its salts are widely used, but are notoriously difficult to characterize due to their polyelectrolyte properties and broad molecular mass distributions. In this paper, we report on a new PAA analysis by combining asymmetrical flow field-flow fractionation and an advanced SAXS technique using an acoustic levitator to minimize background scattering. The proof-of-principle is demonstrated with a mixture of three standard PAAs with different molecular masses. Detailed information on the PAA fractions is available on radii of gyration, polymer contour lengths, and coil conformation. Our method is expected to be applicable for a wide range of water-soluble synthetic and natural polymers and ideal for molecular masses of 5 × 103–2 × 105 g · mol-1. KW - Fractionation of polymers KW - Molar mass distribution KW - Polyelectrolytes KW - Small-angle X-ray scattering KW - Water-soluble polymers PY - 2010 DO - https://doi.org/10.1002/macp.201000163 SN - 1022-1352 SN - 1521-3935 VL - 211 IS - 19 SP - 2148 EP - 2153 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-22005 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Knappe, Patrick A1 - Bienert, Ralf A1 - Weidner, Steffen A1 - Thünemann, Andreas T1 - Characterization of poly/N-vinyl-2-pyrrolidone)s with broad size distributions N2 - We report on the characterization of the solution structure of poly(N-vinyl-2-pyrrolidone)s (PVP) by small-angle X-ray scattering (SAXS) and by online coupling of asymmetrical flow field-flow fractionation (A4F), SAXS and dynamic light scattering (DLS). The commercial products PVP K30 and PVP K90 with nominal molar masses of 40 × 103 and 360 × 103 g mol-1, respectively, were investigated separately and as binary mixture. Detailed information for all polymer fractions is available on the polymer contour lengths and the diffusion coefficients. Key areas of applications for the A4F-SAXS-DLS coupling are seen in comparison to static light scattering for polymers with radii of gyration smaller than 10 nm, for which only SAXS produces precise analytical results on the size of the polymers in solution. KW - Small-angle X-ray scattering KW - SAXS KW - Field-flow fractionation PY - 2010 DO - https://doi.org/10.1016/j.polymer.2010.02.039 SN - 0032-3861 SN - 1873-2291 VL - 51 IS - 8 SP - 1723 EP - 1727 PB - Springer CY - Berlin AN - OPUS4-21222 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kona, Balakantha Rao A1 - Weidner, Steffen A1 - Friedrich, Jörg Florian T1 - Epoxidation of Polydienes Investigated by MALDI-TOF Mass Spectrometry and GPC-MALDI Coupling N2 - Polybutadienes (PB) and polyisoprenes (PI) with various molecular weights and polydispersities were epoxidized applying two different synthetic routes. The degree of epoxidation was determined by means of matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS). It has been found that the degree of functionalization of polybutadiene is generally lower than that for polyisoprenes. Additionally, PB shows lower degrees of epoxidation at higher masses, whereas the level of functionalization of PI was unaffected by the molar mass. Coupling of gel permeation chromatography (GPC) with MALDI-TOF mass spectrometry was successfully used for the investigation of epoxidized polymers with higher masses. Using mass spectra of single fractions, the degree of epoxidation could be determined and applied for a calibration of GPC. PY - 2005 DO - https://doi.org/10.1080/10236660490935736 SN - 1023-666X SN - 1563-5341 VL - 10 IS - 1-2 SP - 85 EP - 109 PB - Gordon and Breach Publ. CY - Amsterdam AN - OPUS4-11860 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Koshkina, Olga A1 - Lang, Thomas A1 - Thiermann, R. A1 - Docter, D. A1 - Stauber, R.H. A1 - Secker, C. A1 - Schlaad, H. A1 - Weidner, Steffen A1 - Mohr, B. A1 - Maskos, M. A1 - Bertin, Annabelle T1 - Temperature-triggered protein adsorption on polymer-coated nanoparticles in serum N2 - The protein corona, which forms on the nanoparticle's surface in most biological media, determines the nanoparticle’s physicochemical characteristics. The formation of the protein corona has a significant impact on the biodistribution and clearance of nanoparticles in vivo. Therefore, the ability to influence the formation of the protein corona is essential to most biomedical applications, including drug delivery and imaging. In this study, we investigate the protein adsorption on nanoparticles with a hydrodynamic radius of 30 nm and a coating of thermoresponsive poly(2-isopropyl-2-oxazoline) in serum. Using multiangle dynamic light scattering (DLS) we demonstrate that heating of the nanoparticles above their phase separation temperature induces the formation of agglomerates, with a hydrodynamic radius of 1 µm. In serum, noticeably stronger agglomeration occurs at lower temperatures compared to serum-free conditions. Cryogenic transmission electron microscopy (cryo-TEM) revealed a high packing density of agglomerates when serum was not present. In contrast, in the presence of serum, agglomerated nanoparticles were loosely packed, indicating that proteins are intercalated between them. Moreover, an increase in protein content is observed upon heating, confirming that protein adsorption is induced by the alteration of the surface during phase separation. After cooling and switching the surface back, most of the agglomerates were dissolved and the main fraction returned to the original size of approximately 30 nm as shown by asymmetrical flow-field flow fractionation (AF-FFF) and DLS. Furthermore, the amounts of adsorbed proteins are similar before and after heating the nanoparticles to above their phase-separation temperature. Overall, our results demonstrate that the thermoresponsivity of the polymer coating enables turning the corona formation on nanoparticles on and off in situ. As the local heating of body areas can be easily done in vivo, the thermoresponsive coating could potentially be used to induce the agglomeration of nanoparticles and proteins and the accumulation of nanoparticles in a targeted body region. PY - 2015 DO - https://doi.org/10.1021/acs.langmuir.5b00537 SN - 0743-7463 SN - 1520-5827 VL - 31 IS - 32 SP - 8873 EP - 8881 PB - American Chemical Society CY - Washington, DC AN - OPUS4-34163 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Krause, Benjamin Christoph A1 - Seifert, Stephan A1 - Panne, Ulrich A1 - Kneipp, Janina A1 - Weidner, Steffen T1 - Matrix-assisted laser desorption/ionization mass spectrometric investigation of pollen and their classification by multivariate statistics N2 - RATIONALE A fast and reliable online identification of pollen is not yet available. The identification of pollen is based mainly on the evaluation of morphological data obtained by microscopic methods. METHODS Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOF MS) was applied to the analysis of extracts and milled pollen samples. The obtained MALDI data were explored for characteristic peak patterns which could be subjected to a multivariate statistical analysis. RESULTS Two sample preparation methods are presented, which require only minimal or no chemical extraction of the pollen. MALDI pollen spectra could be recorded showing various peak patterns. A multivariate statistics approach allowed the classification of pollen into clusters indicating similarities and differences between various species. CONCLUSIONS These results demonstrate the potential and the reliability of MALDI-TOF MS for the identification and, in combination with multivariate statistics, also for the classification of pollen. KW - MALDI TOF mass spectrometry KW - Pollen KW - Multivariate statistics PY - 2012 DO - https://doi.org/10.1002/rcm.6202 SN - 0951-4198 SN - 1097-0231 VL - 26 IS - 9 SP - 1032 EP - 1038 PB - Wiley CY - Chichester AN - OPUS4-25648 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kricheldorf, H. R. A1 - Meyer, A. A1 - Weidner, Steffen T1 - High Tm Poly(l-lactide)s by Means of Bismuth Catalysts? N2 - One series of BiSub-catalyzed ring-opening polymerizations (ROPs) is per-formed at 160 °C for 3 days with addition of difunctional cocatalysts to find out, if poly(l-lactide) crystallizes directly from the reaction mixture. An analogous series is performed with monofunctional cocatalysts. High Tm crystal-lites (Tm > 190 °C) are obtained from all bifunctional cocatalysts, but not from all monofunctional ones. It is shown by means of SAXS measurements that the high Tm values are mainly a consequence of a transesterification–homogenization process across the lamellar surfaces resulting in thickness and smoothing of the surfaces. An unusual enthalpy-driven modification of the molecular weight distribution is found for samples that have crystallized during the polymerization. A third series of ROPs is performed at 170 °C for 2 h followed by annealing at 120 °C (2 h) to induce crystallization. Complete transformation of the resulting low Tm crystallites (Tm < 180 °C) into the high Tm crystallites by annealing at 170 °C for 1 d is not achieved, despite variation of the cocatalyst. KW - Polylactide KW - MALDI-TOF MS KW - Crystallization PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-522777 DO - https://doi.org/10.1002/macp.202100019 SN - 1022-1352 VL - 222 IS - 8 SP - 19 PB - Wiley AN - OPUS4-52277 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kricheldorf, H. R. A1 - Scheliga, F. A1 - Weidner, Steffen T1 - What does conversion mean in polymer science? N2 - The definition of the term “conversion” is discussed for a variety of polymer syntheses. It is demonstrated that in contrast to organic and inorganic chemistry several different definitions are needed in polymer science. The influence of increasing conversion on structure and topology of homo- and Copolymers is illustrated. Chain-growth polymerizations, such as radical polymerization or living anionic polymerizations of vinyl monomers, condensative chain polymerization, two and three-dimensional step-growth polymerizations, ring–ring or chain–chain equilibration and chemical modification of polymers are considered. KW - Polymers KW - Polymerization KW - Conversion KW - Polycondensation PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-523597 DO - https://doi.org/10.1002/macp.202100010 VL - 222 IS - 8 SP - 10 PB - Wiley VCH AN - OPUS4-52359 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kricheldorf, H. R. A1 - Weidner, Steffen T1 - The Ring-Opening Polymerisation-Polycondensation (ROPPOC) Approach to cyclic Polymers N2 - A new concept called “Ring-Opening Polymerization (ROP) combined with simultaneous POlyCondensation” (ROPPOC) is presented and discussed. This synthetic strategy is based on the intermediate formation of chains having two end groups that can react with each other. The ROPPOC syntheses are subdivided into three groups according to the nature of the chain ends: two ionic end groups, one ionic and one covalent chain end and a combination of two reactive covalent end groups may be involved, depending on the catalyst. The usefulness for the preparation of cyclic polymers is discussed with a review of numerous previously published examples. These examples concern to following classes of cyclic polymers: polypeptides, polyamides, polyesters, including polycarbonates, and cyclic polysiloxanes. It is demonstrated, that the results of certain ROPPOC syntheses are in contradiction to the Jacobson-Stockmayer theory. Finally, the usefulness of ROPPOCs for the detection of polydisperse catenanes is discussed. KW - Ring-opening Polymerisation KW - MALDI-TOF MS KW - ROPPOC KW - Cyclic PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-508509 DO - https://doi.org/10.1002/marc.202000152 SP - 2000152 PB - Wiley AN - OPUS4-50850 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kricheldorf, H. R. A1 - Weidner, Steffen T1 - Polymerization of L-lactide with SnCl2: A Low Toxic and Eco-friendly Catalyst N2 - Polymerizations of L-lactide catalyzed either by neat SnCl2 or by SnCl2 + difunctional cocatalysts were conducted in bulk at 180, 160 and 140 °C with variation of the Lac/Cat ratio and time. With neat SnCl2 poly(L-lactide) having weight average molecular weights (uncorrected Mw’s) up to 190 000 g mol−1 were obtained mainly consisting of linear chains. Addition of salicylic acid or 1,1-bisphenol yielded a higher fraction of cyclic polylactides but lower molecular weights. Furthermore, SnCl2 was compared with Bu2SnCl2 and various other metal chlorides and the best results were obtained with SnCl2. With ethyl L-lactate as initiator SnCl2-catalyzed ROPs were performed at 120 °C and the lac/initiator ratio was varied. All these experiments were conducted under conditions allowing for comparison with ROPs catalyzed with neat Sn(II)-2-ethyhexanoate. Such a comparison was also performed with ε-caprolactone as monomer. KW - Catalyst KW - Polylactide KW - MALDI-TOF MS KW - Polycondensation PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-520517 DO - https://doi.org/10.1007/s10924-020-02042-w SN - 1566-2543 SP - 1 EP - 13 PB - Springer Nature AN - OPUS4-52051 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -