TY - JOUR A1 - Weidner, Steffen A1 - Kühn, Gerhard A1 - Just, Ulrich T1 - Characterization of oligomers in poly(ethylene terephthalate) by matrix-assisted laser desorption/ionization mass spectrometry PY - 1995 SN - 0951-4198 SN - 1097-0231 IS - 9 SP - 697 EP - 702 PB - Wiley CY - Chichester AN - OPUS4-11278 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weidner, Steffen A1 - Kühn, Gerhard A1 - Just, Ulrich A1 - Werthmann, Barbara A1 - Decker, Renate A1 - Schwarz, Bärbel A1 - Borowski, Renate T1 - MALDI/MS - A New Technique in Characterizing Chemical Heterogeneity of Degradation Products of Poly(Ethylene Terephthalate)s T2 - International GPC Symposium '96 CY - San Diego, CA, USA DA - 1996-09-08 PY - 1996 SP - 632 EP - 651 CY - Milford, Mass. AN - OPUS4-11905 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kühn, Gerhard A1 - Weidner, Steffen A1 - Just, Ulrich A1 - Hohner, G. T1 - Characterization of technical waxes - Comparison of chromatographic techniques and matrix-assisted laser-desorption/ionization mass spectrometry N2 - Technical waxes and paraffins were investigated using supercritical fluid chromatography (SFC), matrix-assisted laser-desorption/ionization mass spectrometry (MALDI-MS) and size-exclusion chromatography (SEC). SEC enables the simultaneous determination of molecular masses up to high values and molecular mass distributions. The resolution of homologous species, however, is poor. In this respect the use of SFC is advantageous. Proper resolution of homologues may be provided up to Mr~1200 without great difficulty. To compare these chromatographic results MALDI-MS was applied for the determination of molecular masses and mass distributions in technical waxes for the first time. Using reflectron mode excellent MALDI mass spectra could be achieved in the molecular mass range up to 1000 Da. The mean values of the molecular masses calculated by MALDI-MS were in sufficient agreement with those of SFC. In the linear mode of MALDI-MS molecular masses could be determined to nearly 3000 Da. Beyond this mass range SEC still remains the method of choice. Advantages and difficulties of the used methods are discussed in this paper. PY - 1996 U6 - https://doi.org/10.1016/0021-9673(95)01255-9 SN - 0021-9673 VL - 732 IS - 1 SP - 111 EP - 117 PB - Elsevier CY - Amsterdam AN - OPUS4-11347 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weidner, Steffen A1 - Kühn, Gerhard A1 - Werthmann, Barbara A1 - Schröder, Hartmut A1 - Just, Ulrich A1 - Borowski, Renate A1 - Decker, Renate A1 - Schwarz, Bärbel A1 - Schmücking, I. A1 - Seifert, Ingetraut T1 - A new approach of characterizing the hydrolytic degradation of poly(ethylene terephthalate) by MALDI-MS N2 - The hydrolytic degradation of technical poly(ethylene terephthalate) (PET) was investigated by means of different methods such as size-exclusion chromatography (SEC), viscometry, light-scattering, thin-layer chromatography, end-group titration, and matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The long-term degradation was simulated by exposing PET filament yarns to aqueous neutral conditions at 90°C for up to 18 weeks. By means of MALDI-MS and thin-layer chromatography, the formation of different oligomers was obtained during polymer degradation. As expected, an ester scission process was found generating acid terminated oligomers (H-[GT]m-OH) and T-[GT]m-OH and ethylene glycol terminated oligomers (H-[GT]m-G), where G is an ethylene glycol unit and T is a terephthalic acid unit. Additionally, the scission of the ester bonds during the chemical treatment led to a strong decrease in the number of cyclic oligomers ([GT]m). The occurrence of di-acid terminated species demonstrated a high degree of degradation. PY - 1997 U6 - https://doi.org/10.1002/(SICI)1099-0518(199708)35:11<2183::AID-POLA9>3.0.CO;2-Z SN - 0360-6376 SN - 0887-624X VL - 35 IS - 11 SP - 2183 EP - 2192 PB - Wiley CY - Hoboken, NJ AN - OPUS4-11357 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Just, Ulrich A1 - Werthmann, Barbara A1 - Weidner, Steffen T1 - Referenzmaterialien für die Polymeranalytik - Verfahren zur Charakterisierung und Bewertung PY - 1998 SN - 0943-6677 VL - 49 IS - 6 SP - 223 EP - 228 PB - Rubikon CY - Gaiberg bei Heidelberg AN - OPUS4-11261 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Just, Ulrich A1 - Weidner, Steffen A1 - Wittke, Wolfgang A1 - Friedrich, Jörg Florian A1 - Rittig, F. A1 - Gruber, F. T1 - 2D-Characterization of Polyamides using Chromatography and MALDI-TOF-MS T2 - Waters International GPC 2003 and ISPAC-16-Symposium CY - Baltimore, MD, USA DA - 2003-06-09 PY - 2003 AN - OPUS4-2631 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weidner, Steffen A1 - Just, Ulrich A1 - Wittke, Wolfgang A1 - Rittig, F. A1 - Gruber, F. A1 - Friedrich, Jörg Florian T1 - Analysis of modified polyamide 6.6 using coupled liquid chromatography and MALDI-TOF-mass spectrometry KW - MALDI-TOF-MS KW - Liquid chromatography KW - Coupling methods PY - 2004 SN - 0168-1176 SN - 0020-7381 SN - 1387-3806 SN - 1873-2798 VL - 238 IS - 3 SP - 235 EP - 244 PB - Elsevier CY - Amsterdam AN - OPUS4-6966 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Just, Ulrich A1 - Weidner, Steffen A1 - Kilz, P. A1 - Hofe, T. T1 - Polymer Reference Materials: Round-Robin Tests for the Determination of Molar Masses N2 - This article reports round-robin tests dealing with static light scattering (LS), size exclusion chromatography (SEC), and viscometry measurements of 10 reference materials of various polymer classes: poly(styrene)s (PS), poly(methyl methacrylate)s (PMMA), poly(ethylene oxide)s (PEO), and poly(lactide)s (PLA). In the certificates, molar masses and intrinsic viscosities as well as their uncertainties are specified. Additional values from nuclear magnetic resonance (NMR), infrared spectroscopy (IR), differential scanning calorimetry (DSC), melt flow index (MFR), and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS), which were determined exclusively in BAM laboratories are given, as well. These results represent the base for the BAM certification work of creating polymer reference materials according to the BAM Guidelines for the Production and Certification of BAM Reference Materials, a version of the European guidelines (BCR/01/97). These samples are available for third-party user. KW - Polymer reference materials KW - CRM KW - Molar mass determination KW - Intrinsic viscosity KW - Light scattering (LS) KW - Size exclusion chromatography (SEC) PY - 2005 U6 - https://doi.org/10.1080/10236660500418039 SN - 1023-666X SN - 1563-5341 VL - 10 IS - 3-4 SP - 225 EP - 243 PB - Gordon and Breach Publ. CY - Amsterdam AN - OPUS4-11815 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weidner, Steffen A1 - Falkenhagen, Jana A1 - Krüger, Ralph-Peter A1 - Just, Ulrich T1 - Principle of Two-Dimensional Characterization of Copolymers N2 - Two-dimensional polymer characterization is used for a simultaneous analysis of molar masses and chemical heterogeneities (e.g., end groups, copolymer composition, etc.). This principle is based on coupling of two different chromatographic modes. Liquid adsorption chromatography at critical conditions (LACCC) is applied for a separation according to the chemical heterogeneity, whereas in the second-dimension fractions are analyzed with regard to their molar mass distribution by means of size exclusion chromatography (SEC). Because appropriate standards for a calibration of the SEC are seldom available, matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF MS) was used to substitute the SEC. The LACCC-MALDI MS coupling enables acquiring additional structural information on copolymer composition, which can considerably enhance the performance of this coupled method. KW - MALDI-TOF MS KW - Chromatographie KW - Kopplung PY - 2007 U6 - https://doi.org/10.1021/ac062145f SN - 0003-2700 SN - 1520-6882 VL - 79 IS - 13 SP - 4814 EP - 4819 PB - American Chemical Society CY - Washington, DC AN - OPUS4-17722 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -