TY - JOUR A1 - Just, Ulrich A1 - Weidner, Steffen A1 - Kilz, P. A1 - Hofe, T. T1 - Polymer Reference Materials: Round-Robin Tests for the Determination of Molar Masses N2 - This article reports round-robin tests dealing with static light scattering (LS), size exclusion chromatography (SEC), and viscometry measurements of 10 reference materials of various polymer classes: poly(styrene)s (PS), poly(methyl methacrylate)s (PMMA), poly(ethylene oxide)s (PEO), and poly(lactide)s (PLA). In the certificates, molar masses and intrinsic viscosities as well as their uncertainties are specified. Additional values from nuclear magnetic resonance (NMR), infrared spectroscopy (IR), differential scanning calorimetry (DSC), melt flow index (MFR), and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS), which were determined exclusively in BAM laboratories are given, as well. These results represent the base for the BAM certification work of creating polymer reference materials according to the BAM Guidelines for the Production and Certification of BAM Reference Materials, a version of the European guidelines (BCR/01/97). These samples are available for third-party user. KW - Polymer reference materials KW - CRM KW - Molar mass determination KW - Intrinsic viscosity KW - Light scattering (LS) KW - Size exclusion chromatography (SEC) PY - 2005 DO - https://doi.org/10.1080/10236660500418039 SN - 1023-666X SN - 1563-5341 VL - 10 IS - 3-4 SP - 225 EP - 243 PB - Gordon and Breach Publ. CY - Amsterdam AN - OPUS4-11815 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kona, Balakantha Rao A1 - Weidner, Steffen A1 - Friedrich, Jörg Florian T1 - Epoxidation of Polydienes Investigated by MALDI-TOF Mass Spectrometry and GPC-MALDI Coupling N2 - Polybutadienes (PB) and polyisoprenes (PI) with various molecular weights and polydispersities were epoxidized applying two different synthetic routes. The degree of epoxidation was determined by means of matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS). It has been found that the degree of functionalization of polybutadiene is generally lower than that for polyisoprenes. Additionally, PB shows lower degrees of epoxidation at higher masses, whereas the level of functionalization of PI was unaffected by the molar mass. Coupling of gel permeation chromatography (GPC) with MALDI-TOF mass spectrometry was successfully used for the investigation of epoxidized polymers with higher masses. Using mass spectra of single fractions, the degree of epoxidation could be determined and applied for a calibration of GPC. PY - 2005 DO - https://doi.org/10.1080/10236660490935736 SN - 1023-666X SN - 1563-5341 VL - 10 IS - 1-2 SP - 85 EP - 109 PB - Gordon and Breach Publ. CY - Amsterdam AN - OPUS4-11860 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Falkenhagen, Jana A1 - Weidner, Steffen T1 - Detection limits of matrix-assisted laser desorption/ionisation mass spectrometry coupled to chromatography - a new application of solvent-free sample preparation N2 - The detection limits of matrix-assisted laser desorption/ionisation mass spectrometry (MALDI-MS) by semi-online coupling with chromatography were investigated using various mixtures of polyethylene oxides (PEOs) with different end groups. In contrast to the common dried-droplet sample preparation technique, which results in an inhomogeneous sample-to-matrix ratio within the MALDI spot, the used coupling technique offers a very high reproducibility combined with surpassing sensitivity of a few femtograms over a broad range of sample-to-matrix ratios. These results are in correlation with the results of the recently established solvent-free MALDI-TOFMS method utilising the grinding approach and are also of assistance towards the more theoretical aspect of MALDI that suggests that there is no necessity for an analyte incorporation into a matrix crystal for excellent matrix-assistance. PY - 2005 DO - https://doi.org/10.1002/rcm.2256 SN - 0951-4198 SN - 1097-0231 VL - 19 IS - 24 SP - 3724 EP - 3730 PB - Wiley CY - Chichester AN - OPUS4-11859 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gonzalez-Rojano, N. A1 - Arias-Marin, E. A1 - Navarro-Rodriguez, D. A1 - Weidner, Steffen T1 - Bidirectional Synthesis of a Series of 2,5- Dodecanoy-phenylene-ethynylene oligomers N2 - A family of rigid rod like 2,5-dodecanoxy-phenyleneethynylene oligomers having 3, 5, 7, and 9 repeating units was selectively synthesized by a bi-directional iterative divergent-convergent approach. Starting from a central 1,4-bis(dodecanoxy)-2,5-diiodobenzene monomer, only two repetitive reactions were involved with each cycle of oligomerization: a Pd/Cu cross-coupling with the bifunctional monomer 1-(3,3-diethyltriazene)-2,5-bis(dodecanoxy)-4-(ethynyl)benzene, generating oligomers with terminal triazene groups, followed by a further nucleophilic substitution with iodine. KW - Conjugated oligomers KW - Phenyleneethynylenes KW - Tri­azenes KW - Aryl iodides KW - Sonoga PY - 2005 DO - https://doi.org/10.1055/s-2005-868474 SN - 0936-5214 SN - 1437-2096 IS - 8 SP - 1259 EP - 1262 PB - Thieme CY - Stuttgart AN - OPUS4-11100 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weidner, Steffen A1 - Falkenhagen, Jana A1 - Krüger, Ralph-Peter A1 - Just, Ulrich T1 - Principle of Two-Dimensional Characterization of Copolymers N2 - Two-dimensional polymer characterization is used for a simultaneous analysis of molar masses and chemical heterogeneities (e.g., end groups, copolymer composition, etc.). This principle is based on coupling of two different chromatographic modes. Liquid adsorption chromatography at critical conditions (LACCC) is applied for a separation according to the chemical heterogeneity, whereas in the second-dimension fractions are analyzed with regard to their molar mass distribution by means of size exclusion chromatography (SEC). Because appropriate standards for a calibration of the SEC are seldom available, matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF MS) was used to substitute the SEC. The LACCC-MALDI MS coupling enables acquiring additional structural information on copolymer composition, which can considerably enhance the performance of this coupled method. KW - MALDI-TOF MS KW - Chromatographie KW - Kopplung PY - 2007 DO - https://doi.org/10.1021/ac062145f SN - 0003-2700 SN - 1520-6882 VL - 79 IS - 13 SP - 4814 EP - 4819 PB - American Chemical Society CY - Washington, DC AN - OPUS4-17722 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Trimpin, S. A1 - Weidner, Steffen A1 - Falkenhagen, Jana A1 - McEwen, C.N. T1 - Fractionation and Solvent-Free MALDI-MS Analysis of Polymers Using Liquid Adsorption Chromatography at Critical Conditions in Combination with a Multisample On-Target Homogenization/Transfer Sample Preparation Method N2 - A solvent-free homogenization/transfer matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) method is described for the preparation and precise transfer of up to 100 samples simultaneously on a single MALDI plate. This method is demonstrated using a poly(ethylene oxide) (PEO) mixture consisting of different molecular weights (500-6000) and end groups (PEO, dimethoxy-PEO, monomethoxy monomethacrylate-PEO, and dimethacrylate-PEO) that was fractionated using liquid adsorption chromatography at critical conditions. Off-line fractionation is performed prior to the on-target homogenization/transfer solvent-free sample preparation and MALDI mass analysis. The miniaturization of the solvent-free MALDI approach allowed analysis of less than 2 g per PEO component per fraction corresponding to ~200 pmol for PEO 6000. The amounts of polymer sample used for LC separation and the quality of the MS results are equivalent to the "dry spray" method; however, three times more fractions were collected and analyzed with the newly developed hyphenated approach. The off-line method eliminates optimization of, for example, spray conditions or spreading of organic solvents on the MALDI plate that occurs with droplet deposition methods. The widespread applications of MALDI make this solvent-free, multisample method particularly important as it expands the capabilities for obtaining mass measurements with great efficiencies in areas with increased sample numbers. In addition, the solvent-free method is well suited for automated MALDI analysis as it virtually eliminates the "dead-spot" phenomenon. PY - 2007 DO - https://doi.org/10.1021/ac070986w SN - 0003-2700 SN - 1520-6882 VL - 79 IS - 19 SP - 7565 EP - 7570 PB - American Chemical Society CY - Washington, DC AN - OPUS4-17737 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weidner, Steffen A1 - Falkenhagen, Jana A1 - Maltsev, Sergey A1 - Sauerland, V. A1 - Rinken, M. T1 - A novel software tool for copolymer characterization by coupling of liquid chromatography with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry N2 - The results of copolymer characterization by coupling of chromatography and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) techniques and subsequent calculation of copolymer composition using a novel software tool MassChrom2D are presented. For high-resolution mass analysis copolymer samples were fractionated by means of liquid adsorption chromatography (LAC). These fractions were investigated off-line by MALDI-TOF MS. Various mono-n-butyl ethers of polyethylene oxide-polypropylene oxide copolymers (PEO-co-PPO) were investigated. As well as the copolymer composition presented in two-dimensional plots, the applied approach can give additional hints on specific structure-dependent separation conditions in chromatography. KW - Copolymeranalytik KW - MALDI KW - Software KW - MS/MS KW - Kopplungsmethoden PY - 2007 DO - https://doi.org/10.1002/rcm.3146 SN - 0951-4198 SN - 1097-0231 VL - 21 IS - 16 SP - 2750 EP - 2758 PB - Wiley CY - Chichester AN - OPUS4-17723 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weidner, Steffen A1 - Trimpin, S. T1 - Mass Spectrometry of Synthetic Polymers KW - Mass Spectrometry KW - Polymers KW - Application PY - 2008 DO - https://doi.org/10.1021/ac8006413 SN - 0003-2700 SN - 1520-6882 VL - 80 IS - 12 SP - 4349 EP - 4361 PB - American Chemical Society CY - Washington, DC AN - OPUS4-17718 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Garaleh, M. A1 - Lahcini, M. A1 - Kricheldorf, H.R. A1 - Weidner, Steffen T1 - Syntheses of aliphatic polyesters catalyzed by lanthanide triflates N2 - Polycondensations of 1,6-hexane diol and sebacic acid were conducted in bulk with addition of a lanthanide triflate as acidic catalyst. With exception of promethium triflate all lanthanide triflates were studied. A particularly low molecular weight was obtained with neodym triflate and the best results with samarium triflate. With Sm(OTf)3 weight average (Mw) values up to 65 kDa (uncorrected SEC data) were achieved after optimization of the reaction conditions. Comparison of these results with those obtained from bismuth, magnesium, and zinc triflates, on the one hand, and comparison with the acidities of all catalysts, on the other, indicates that the esterification mechanism involves complexation of monomer by metal ions. Preparation of multiblock copoly(ether ester)s failed due to insufficient incorporation of poly(tetrahydrofuran) diols. KW - Biodegradable polyesters KW - Lanthanide ions KW - Macrocycles KW - MALDI-TOF KW - Polycondensation PY - 2009 DO - https://doi.org/10.1002/pola.23136 SN - 0360-6376 SN - 0887-624X VL - 47 IS - 1 SP - 170 EP - 177 PB - Wiley CY - Hoboken, NJ AN - OPUS4-19626 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Thünemann, Andreas A1 - Rolf, Simone A1 - Knappe, Patrick A1 - Weidner, Steffen T1 - In Situ Analysis of a Bimodal Size Distribution of Superparamagnetic Nanoparticles N2 - The dispersed iron oxide nanoparticles of ferrofluids in aqueous solution are difficult to characterize due to their protective polymer coatings. We report on the bimodal size distribution of superparamagnetic iron oxide nanoparticles found in the MRI contrast agent Resovist, which is a representative example of commercial nanoparticle-based pharmaceutical formulations. The radii of the majority of the nanoparticles (>99%) range from 4 to 13 nm (less than 1% of the particles display radii up to 21 nm). The maxima of the size distributions are at 5.0 and 9.9 nm. The analysis was performed with in situ characterization of Resovist via online coupling of asymmetrical flow field-flow fractionation (A4F) with small-angle X-ray scattering (SAXS) using a standard copper X-ray tube as a radiation source. The outlet of the A4F was directly coupled to a flow capillary on the SAXS instrument. SAXS curves of nanoparticle fractions were recorded at 1-min time intervals. We recommend using the A4F-SAXS coupling as a routine method for analysis of dispersed nanoparticles with sizes in the range of 1-100 nm. It allows a fast and quantitative comparison of different batches without the need for sample preparation. PY - 2009 DO - https://doi.org/10.1021/ac802009q SN - 0003-2700 SN - 1520-6882 VL - 81 IS - 1 SP - 296 EP - 301 PB - American Chemical Society CY - Washington, DC AN - OPUS4-18658 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -