TY - JOUR A1 - Wang, X.-D. A1 - Meier, R.J. A1 - Schmittlein, C. A1 - Schreml, S. A1 - Schäferling, Michael A1 - Wolfbeis, Otto S. T1 - A water-sprayable, thermogelating and biocompatible polymer host for use in fluorescent chemical sensing and imaging of oxygen, pH values and temperature N2 - We report on the use of a sprayable and thermogelating biomaterial (Poloxamer™; a.k.a. Pluronic™) in optical imaging of pH values, local oxygen and temperature. The material is highly biocompatible and easy to handle. We also show that the material is well permeable to oxygen (thus making it a good choice for use in oxygen sensors), and is stable in liquid solution and at elevated temperature. We demonstrate its applicability in optical sensors for oxygen, pH and temperature. This was accomplished by incorporating appropriate luminescent probes in various kinds of microparticles (which act as hosts for the probes and prevent dye leaching and aggregation), and then dispersing the microparticles in the thermogelating polymer. The resulting sensor gels were deposited on the surface of interest via spraying at temperatures of <20 °C. At these temperatures, the gels adhere well to the target, even on uneven surfaces such as skin, wounds, and bacterial cultures. If temperature is risen to above 25 °C, the gels form a thin and soft but solid sensing layer which, however, can be simply removed from surface of interest by cooling and wiping it off, or by washing with water. Sprayable thermogelating sensors present obvious advantages over other sensors by not causing damage to the surface of interest. In our perception, the sensing materials also have wide further applicability in sensors for other species including clinically relevant gases, enzyme substrates (such as glucose or lactate) and ions. KW - Chemical sensing KW - Imaging KW - Biocompatible polymer KW - Sprayable sensor KW - Fluorescence KW - Poloxamer KW - Pluronic KW - Oxygen sensor KW - pH sensor KW - Temperature sensor PY - 2015 U6 - https://doi.org/10.1016/j.snb.2015.05.082 SN - 0925-4005 SN - 1873-3077 VL - 221 SP - 37 EP - 44 PB - Elsevier CY - Amsterdam [u.a.] AN - OPUS4-33855 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wang, X.-d. A1 - Meier, R.J. A1 - Schäferling, Michael A1 - Bange, S. A1 - Lupton, J.M. A1 - Sperber, M. A1 - Wegener, J. A1 - Ondrus, V. A1 - Beifuss, U. A1 - Henne, U. A1 - Klein, C. A1 - Wolfbeis, Otto S. T1 - Two-photon excitation temperature nanosensors based on a conjugated fluorescent polymer doped with an Europium probe N2 - A strongly fluorescent organic semiconducting polymer doped with a highly temperature dependent fluorescent europium(III) complex is converted into a nanosized material that is capable of optically sensing temperature (T) in the range from 0 to 50 °C via two-photon excitation at 720 nm. The nanosensors are prepared from a blue-fluorescent polyfluorene that acts as both a lightharvesting antenna (to capture two-photon energy) and an energy donor in a fluorescence resonance energy transfer (FRET) system. The photonic energy absorbed by the polymer is transferred to the T-sensitive red-luminescent europium complex contained in the nanoparticles. The close spatial proximity of the donor and the acceptor warrants efficient FRET. A poly(ethylene glycol)- co-poly(propylene oxide) block copolymer is also added to render the particles biocompatible. It is shown that T can be calculated from a) the intensity of the luminescence of the europium complex, b) the ratio of the intensities of the red and blue luminescence, or c) the T-dependent luminescence lifetime of the Eu(III) complex. KW - Optical sensor KW - Temperature sensor KW - Nanosensor KW - FRET system PY - 2016 UR - http://onlinelibrary.wiley.com/doi/10.1002/adom.201600601/abstract U6 - https://doi.org/10.1002/adom.201600601 SN - 2195-1071 VL - 4 IS - 11 SP - 1854 EP - 1859 PB - Wiley-VCH CY - Weinheim AN - OPUS4-38737 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -