TY - CONF A1 - Traub, Heike T1 - Localisation and quantification of metallic nanoparticles in single cells by laser ablation ICP-MS T2 - NanoBio Europe, 10th International Congress & Exhibition on Nanobiotechnology CY - Münster, Germany DA - 2014-06-02 PY - 2014 AN - OPUS4-30781 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, L. A1 - Traub, Heike A1 - Jakubowski, Norbert T1 - Novel applications of lanthanoides as analytical or diagnostic tools in the life sciences by ICP-MS-based techniques N2 - Inductively coupled plasma mass spectrometry (ICP-MS) is a well-established analytical method for multi-elemental analysis in particular for elements at trace and ultra-trace levels. It has found acceptance in various application areas during the last decade. ICP-MS is also more and more applied for detection in the life sciences. For these applications, ICP-MS excels by a high sensitivity, which is independent of the molecular structure of the analyte, a wide linear dynamic range and by excellent multi-element capabilities. Furthermore, methods based on ICP-MS offer simple quantification concepts, for which usually (liquid) standards are applied, low matrix effects compared to other conventional bioanalytical techniques, and relative limits of detection (LODs) in the low pg g−1 range and absolute LODs down to the attomol range. In this chapter, we focus on new applications where the multi-element capability of ICP-MS is used for detection of lanthanoides or rare earth elements, which are applied as elemental stains or tags of biomolecules and in particular of antibodies. KW - ICP-MS KW - Life sciences KW - Mass cytometry KW - Laser ablation (LA)-ICP-MS KW - Bioimaging PY - 2016 DO - https://doi.org/10.1515/psr-2016-0064 SN - 2365-659X SN - 2365-6581 VL - 1 IS - 11 SP - 1 EP - 19 AN - OPUS4-40234 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Scharek, Vera M. A1 - Pfeifer, Jens A1 - Vogl, Jochen A1 - Traub, Heike A1 - Meermann, Björn T1 - Tin fractionation analysis in sediment samples via on-line ID ETV/ICP-MS N2 - We report a quantification approach for directly determining total tin and tin-based pollutants/species in sediments via electrothermal vaporization/inductively coupled plasma-mass spectrometry (ETV/ICP-MS) utilizing an on-line isotope dilution mass spectrometry (IDMS) approach. The method was developed and validated using an estuarine sediment reference material (BCR-277R), yielding a recovery of 106%. A relative standard deviation (RSD) of 14%, comparable to published data using a similar method, was obtained. A limit of quantification (LOQ) was estimated at 0.008 mg Sn kg−1 and sufficient for quantifying the total tin mass fraction of surface sediments along the tidal River Elbe course. Hereby, a decrease towards the river mouth, presumably due to dilution effects by less polluted marine sediment, was observed. Besides total tin, monitoring of organotin compounds (OTCs)/species is of interest in sediments due to their toxic effects on aquatic life. The method’s capability was extended by separating an OTC fraction in a sediment certified reference material (CRM) through the ETV temperature program. While spiking experiments with OTC standards confirmed the assignment, only a small fraction of the total certified OTC amount (3%), likely due to matrix effects, was recovered. However, applying the method to real-world samples, OTCs were detectable along the River Elbe course. By this, we demonstrated the potential of our method as a complementary fast-screening approach to species-specific analysis procedures. KW - ETV KW - Sn-Speciation KW - Sediment PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-640137 DO - https://doi.org/10.1007/s00216-025-06064-y SN - 1618-2642 SP - 1 EP - 10 PB - Springer Science and Business Media LLC AN - OPUS4-64013 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Drescher, D. A1 - Büchner, T. A1 - Schrade, P. A1 - Traub, Heike A1 - Werner, S. A1 - Guttmann, P. A1 - Bachmann, S. A1 - Kneipp, J. T1 - Influence of Nuclear Localization Sequences on the Intracellular Fate of Gold Nanoparticles N2 - Directing nanoparticles to the nucleus by attachment of nuclear localization sequences (NLS) is an aim in many applications. Gold nanoparticles modified with two different NLS were studied while crossing barriers of intact cells, including uptake, endosomal escape, and nuclear translocation. By imaging of the nanoparticles and by characterization of their molecular interactions with surface-enhanced Raman scattering (SERS), it is shown that nuclear translocation strongly depends on the particular incubation conditions. After an 1 h of incubation followed by a 24 h chase time, 14 nm gold particles carrying an adenoviral NLS are localized in endosomes, in the cytoplasm, and in the nucleus of fibroblast cells. In contrast, the cells display no nanoparticles in the cytoplasm or nucleus when continuously incubated with the nanoparticles for 24 h. The ultrastructural and spectroscopic data indicate different processing of NLS-functionalized particles in endosomes compared to unmodified particles. NLS functionalized nanoparticles form larger intraendosomal aggregates than unmodified gold nanoparticles. SERS spectra of cells with NLS-functionalized gold nanoparticles contain bands assigned to DNA and were clearly different from those with unmodified gold nanoparticles. The different processing in the presence of an NLS is influenced by a continuous exposure of the cells to nanoparticles and an ongoing nanoparticle uptake. This is supported by mass-spectrometry-based quantification that indicates enhanced uptake of NLS-functionalized nanoparticles compared to unmodified particles under the same conditions. The results contribute to the optimization of nanoparticle analysis in cells in a variety of applications, e.g., in theranostics, biotechnology, and bioanalytics. KW - Nanoparticle KW - Laser ablation KW - SERS KW - ICP-MS PY - 2021 DO - https://doi.org/10.1021/acsnano.1c04925 SN - 1936-086X VL - 15 IS - 9 SP - 14838 EP - 14849 PB - American Chemical Society AN - OPUS4-54047 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Erste praktische Erfahrungen mit einem ETV ICP OES-System T2 - Anwenderseminar über die direkte Analyse von Festproben mit simultaner ICP-OES / Analyse organischer und anorganischer Proben mit elektrothermischer Verdampfung (ETV) und Lichtbogen-Emission CY - Neu-Isenburg, Deutschland DA - 2002-09-23 PY - 2002 AN - OPUS4-1932 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Traub, Heike A1 - Scharf, Holger T1 - NH4NO3 extractable trace element contents of soil samples prepared for proficiency testing - a stability study N2 - In view of its intended use as a sample for proficiency testing or as a reference material the stability of the extractable trace element contents of a soil from an irrigation field was tested using the extraction with 1 mol/L ammonium nitrate solution according to DIN 19730. Therefore, changes of the extractability of sterilized and non sterilized soil samples stored at different temperatures were evaluated over a period of 18 months. Sets of bottles were kept at -20 °C, +4 °C, about +20 °C and +40 °C, respectively. The NH4NO3 extractable contents of Cd, Cr, Cu, Ni, Pb and Zn were determined immediately after bottling and then after 3, 6, 12 and 18 months with ICP-AES or ETAAS. Appropriate storage conditions are of utmost importance to prevent deterioration of soil samples prepared for the determination of NH4NO3 extractable trace element contents. Temperatures above +20 °C must be avoided. The observed changes in the extractability of the metals (especially for Cr and Cu) most likely could be related to thermal degradation of the organic matter of the soil. There is no need to sterilize dry soil samples, because microbiological activity in soils with a low moisture content appears to be negligible with regard to trace element mobilization. KW - Spurenelemente KW - Boden KW - Stabilität KW - Referenzmaterial PY - 2001 DO - https://doi.org/10.1007/s002160100748 SN - 0937-0633 VL - 370 IS - 2-3 SP - 270 EP - 274 PB - Springer CY - Berlin AN - OPUS4-1073 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Erste praktische Erfahrungen mit einem ETV-ICP-OES - System T2 - Anwenderseminar der Fa. Thermo Elemental CY - Neu-Isenburg, Germany DA - 2002-09-23 PY - 2002 AN - OPUS4-2945 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Analyse von Hochtechnologiematerialien mit ETV und Bogen T2 - Solid-Samping-User-Meeting CY - Kempten, Germany DA - 2004-05-24 PY - 2004 AN - OPUS4-3571 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Matschat, Ralf A1 - Czerwensky, Michael A1 - Traub, Heike A1 - Heinrich, Hans-Joachim A1 - Kipphardt, Heinrich T1 - Special new techniques of atomic spectrometric methods for trace analysis of high purity metals PY - 2003 SN - 0032-6895 SN - 1778-3771 VL - 91 IS - Décembre SP - 37 EP - 50, N° Hors Série CY - Paris AN - OPUS4-6188 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Direkte Feststoffanalyse von Hochtechnologie-Materialien mit ETV ICP OES und DC-Arc-OES T2 - Abteilungsseminar der Abt. I CY - Berlin, Germany DA - 2005-06-20 PY - 2005 AN - OPUS4-11909 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Comparison of different calibration strategies for the analysis of pure copper by LA-ICP-MS T2 - 13th International Conference on ultra high-purity base metals, BAM CY - Berlin, Germany DA - 2006-09-11 PY - 2006 AN - OPUS4-13480 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Determination of trace impurities in pure copper using LA-ICP-MS T2 - 16. Jahreskolloquium der Interessengemeinschaft Atomspektroskopie (IGAS) CY - Berlin, Germany DA - 2006-11-08 PY - 2006 AN - OPUS4-13778 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Analyse von reinem Kupfer mit LA-ICP-MS: Möglichkeiten der Kalibrierung mit synthetischen Standards T2 - CANAS '07, Colloquium Analytische Atomspektroskopie CY - Konstanz, Germany DA - 2007-03-18 PY - 2007 AN - OPUS4-14627 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Vergleich unterschiedlicher Ansätze zur Kalibrierung bei der Analyse von reinem Kupfer mit LA-ICP-MS T2 - ANAKON 2007 CY - Jena, Germany DA - 2007-03-27 PY - 2007 AN - OPUS4-14642 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Homogenitätsprüfung und Analyse von reinem Kupfer mit Laserablation-ICP-Massenspektrometrie T2 - 4. Hochschul-Kupfersymposium CY - Berlin, Germany DA - 2007-11-06 PY - 2007 AN - OPUS4-14803 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Traub, Heike A1 - Czerwensky, Michael A1 - Matschat, Ralf A1 - Kipphardt, Heinrich A1 - Panne, Ulrich T1 - Homogenitätsprüfung und Analyse von reinem Kupfer mit Laserablation-ICP-Massenspektrometrie KW - Laserablation KW - Kupfer KW - Homogenität KW - ZRM PY - 2007 SN - 0026-0746 VL - 61 IS - 11 SP - 744 EP - 745 PB - Giesel Verlag GmbH CY - Isernhagen AN - OPUS4-16153 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Laser ablation ICP-MS for the determination of trace impurities in pure copper T2 - EuroAnalysis XIV CY - Antwerp, Belgium DA - 2007-09-09 PY - 2007 AN - OPUS4-15692 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Application of synthetic calibration samples for the analysis of pure copper using femtosecond LA-ICP-MS T2 - 9th European Workshop on laser ablation in elemental and isotopic analysis CY - Prague, Czech Republic DA - 2008-07-07 PY - 2008 AN - OPUS4-17541 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Einsatz synthetischer Kalibrierproben für die Analyse von Reinkupfer mit fs-LA-ICP-MS T2 - 21. ICP-MS Anwendertreffen und 8. Symposium über Massenspektrometrische Verfahren der Elementspurenanalyse CY - Dresden, Germany DA - 2008-09-17 PY - 2008 AN - OPUS4-17719 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Beitrag der LA-ICP-MS zur Charakterisierung von Kupfer-Referenzmaterialien T2 - 21. ICP-MS Anwendertreffen und 8. Symposium über Massenspektrometrische Verfahren der Elementspurenanalyse CY - Dresden, Germany DA - 2008-09-17 PY - 2008 AN - OPUS4-17715 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Fast determination of the boron isotope ratio in steel and aluminium alloys using LA-ICP-MS T2 - 9th European Workshop on Laser Ablation in Elemental and Isotopic Analysis CY - Prague, Czech Republic DA - 2008-07-07 PY - 2008 AN - OPUS4-18063 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Höpken, C. A1 - Swart, Claudia A1 - Traub, Heike T1 - A fragment of a dichroic cage cup from Dülük Baba Tepesi/Doliche, Turkey KW - Diatretglas KW - LA-ICP-MS PY - 2008 SN - 0075-4250 VL - 50 SP - 303 EP - 306 CY - Corning, NY AN - OPUS4-18442 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Application of different calibration strategies for the analysis of pure copper using nano- and femtosecond laser ablation ICP-MS T2 - European Winter Conference on Plasma Spectrochemistry CY - Graz, Austria DA - 2009-02-15 PY - 2009 AN - OPUS4-19007 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wienold, Julia A1 - Traub, Heike A1 - Lange, Britta A1 - Giray, Thorsten A1 - Recknagel, Sebastian A1 - Kipphardt, Heinrich A1 - Matschat, Ralf A1 - Panne, Ulrich T1 - Elemental analysis of copper and magnesium alloy samples using IR-laser ablation in comparison with spark and glow discharge methods N2 - Three methods for direct solid sampling of bulk material namely IR laser ablation, glow discharge and spark OES, were compared with respect to analytical figures of merit obtained for elemental analysis with atomic spectrometry. Matrices investigated were copper, pressed doped copper powder, and magnesium alloys. For the vast majority of analytes, statistical equivalence regarding precision (usually ≤ 5%) and the performance of the calibrations between the compared methods was demonstrated. KW - LA-ICP-MS KW - GD-MS KW - Spark-OES KW - LA-ICP-OES KW - Copper KW - Magnesium PY - 2009 DO - https://doi.org/10.1039/b903251g SN - 0267-9477 SN - 1364-5544 VL - 24 SP - 1570 EP - 1574 PB - Royal Society of Chemistry CY - London AN - OPUS4-20257 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Larissa A1 - Traub, Heike A1 - Jakubowski, Norbert A1 - Drescher, Daniela A1 - Baranov, Vladimir A1 - Kneipp, Janina T1 - Trends in single-cell analysis by use of ICP-MS N2 - The analysis of single cells is a growing research field in many disciplines such as toxicology, medical diagnosis, drug and cancer research or metallomics, and different methods based on microscopic, mass spectrometric, and spectroscopic techniques are under investigation. This review focuses on the most recent trends in which inductively coupled plasma mass spectrometry (ICP-MS) and ICP optical emission spectrometry (ICP-OES) are applied for single-cell analysis using metal atoms being intrinsically present in cells, taken up by cells (e.g., nanoparticles), or which are artificially bound to a cell. For the latter, especially element tagged antibodies are of high interest and are discussed in the review. The application of different sample introduction systems for liquid analysis (pneumatic nebulization, droplet generation) and elemental imaging by laser ablation ICP-MS (LA-ICP-MS) of single cells are highlighted. Because of the high complexity of biological systems and for a better understanding of processes and dynamics of biologically or medically relevant cells, the authors discuss the idea of 'multimodal spectroscopies.' KW - Bioanalytical methods KW - Cell systems/single cell analysis KW - Mass spectrometry/ICP-MS PY - 2014 DO - https://doi.org/10.1007/s00216-014-8143-7 SN - 1618-2642 SN - 1618-2650 VL - 406 IS - 27 SP - 6963 EP - 6977 PB - Springer CY - Berlin AN - OPUS4-31717 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Büchner, Tina A1 - Drescher, Daniela A1 - Traub, Heike A1 - Schrade, P. A1 - Bachmann, S. A1 - Jakubowski, Norbert A1 - Kneipp, Janina T1 - Relating surface-enhanced Raman scattering signals of cells to gold nanoparticle aggregation as determined by LA-ICP-MS micromapping N2 - The cellular response to nanoparticle exposure is essential in various contexts, especially in nanotoxicity and nanomedicine. Here, 14-nm gold nanoparticles in 3T3 fibroblast cells are investigated in a series of pulse-chase experiments with a 30-min incubation pulse and chase times ranging from 15 min to 48 h. The gold nanoparticles and their aggregates are quantified inside the cellular ultrastructure by laser ablation inductively coupled plasma mass spectrometry micromapping and evaluated regarding the surface-enhanced Raman scattering (SERS) signals. In this way, both information about their localization at the micrometre scale and their molecular nanoenvironment, respectively, is obtained and can be related. Thus, the nanoparticle pathway from endocytotic uptake, intracellular processing, to cell division can be followed. It is shown that the ability of the intracellular nanoparticles and their accumulations and aggregates to support high SERS signals is neither directly related to nanoparticle amount nor to high local nanoparticle densities. The SERS data indicate that aggregate geometry and interparticle distances in the cell must change in the course of endosomal maturation and play a critical role for a specific gold nanoparticle type in order to act as efficient SERS nanoprobe. This finding is supported by TEM images, showing only a minor portion of aggregates that present small interparticle spacing. The SERS spectra obtained after different chase times show a changing composition and/or structure of the biomolecule corona of the gold nanoparticles as a consequence of endosomal processing. KW - Gold nanoparticles KW - Surface-enhanced Raman scattering KW - LA-ICP-MS KW - Fibroblast KW - Cell KW - Particle aggregation KW - Endosome PY - 2014 DO - https://doi.org/10.1007/s00216-014-8069-0 SN - 1618-2642 SN - 1618-2650 VL - 406 IS - 27 SP - 7003 EP - 7014 PB - Springer CY - Berlin AN - OPUS4-31718 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Studying cellular uptake and processing of nanoparticles by LA-ICP-MS N2 - In recent years, elemental imaging of biological samples using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is gaining in importance. Recent improvements regarding spatial resolution (down to 1 µm) and washout time make LA-ICP-MS particularly interesting for single cell analysis. Many current nanomaterials can serve as contrast agents in cellular or tissue imaging, drug delivery vehicles or therapeutics, whereas others can cause toxic effects. In order to evaluate nano-bio interactions, the number of nanoparticles (NPs) inside cells as well as their localisation within cellular substructures is of particular interest. LA-ICP-MS was used to study the NP pathway from uptake, via intracellular processing up to cell division. Fibroblast cells were incubated with different metallic NPs under varying experimental conditions. For LA analysis the cells were fixed with formaldehyde and dried. Our results show that LA-ICP-MS is able to localise NP aggregates within cellular substructures. The NPs accumulate in the perinuclear region in the course of intracellular processing, e.g. multivesicular fusion and endosomal maturation, but do not enter the nucleus [1, 2]. A strong dependence of NP uptake on concentration and incubation time was found. Additionally, the number of NPs internalized by individual cells was determined and variations within the cell population became visible. A new laser ablation system providing a short washout time (50 ms) together with small spot sizes (< 4 µm) and high repetition rates allows high spatial resolution applications. First results of cell imaging will be shown. The findings demonstrate the potential of LA-ICP-MS providing insight into NP uptake and intracellular distribution dependent on experimental parameters. T2 - 13th European Workshop on Laser Ablation CY - Ljubljana, Slovenia DA - 12.07.2016 KW - LA-ICP-MS KW - Nanoparticle KW - Bio-imaging KW - Cell PY - 2016 AN - OPUS4-36891 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Studying nanoparticle-cell interaction by LA ICP-MS N2 - The interaction of nanoparticles (NPs) with cells has become a major field of interest, ranging from medical applications to nanotoxicology. Size, shape and surface modification of the NPs determine the uptake rate and pathway into the cells, and therefore impact specific cell components and processes. Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is an established quantitative multi-elemental analysis and mapping technique. In recent years, it was shown that LA-ICP-MS can provide quantitative as well as distribution information of NPs in cell samples. Here LA-ICP-MS was applied for the imaging of individual cells to study the uptake and intracellular processing of metal-containing nanostructures. Additionally, the local distribution of naturally occurring elements in cells like P was measured to indicate cell morphology. The cells were incubated with different types of NPs under varying experimental conditions. For LA analysis, the cells were fixed and dried. Our findings show, that LA-ICP-MS is suitable for the localisation of nanoparticle aggregates within cellular compartments. The studied NPs accumulate in the perinuclear region in the course of intracellular processing, but do not enter the cell nucleus. The uptake efficiency depends strongly on the physicochemical properties of the nanostructures as well as on the incubation conditions like concentration and incubation time. The results demonstrate the potential of LA-ICP-MS providing insight into NP uptake, intracellular distribution and cell-to-cell variation dependent on experimental parameters. T2 - Workshop on Laser Bioimaging Mass Spectrometry CY - Münster, Germany DA - 24.05.2018 KW - Imaging KW - Laser ablation KW - ICP-MS KW - Nanoparticle KW - Cell PY - 2018 AN - OPUS4-45071 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - LA-ICP-MS to study nanoparticle-cell interaction N2 - Nanoparticles (NPs) have found a wide range of applications in research and industry. Thereby the interaction of NPs with biological systems like cells has become a major field of interest, ranging from medical applications to nanotoxicology. Size, shape and surface modification of the nanomaterials determine the uptake rate and pathway into the cells, and therefore impact specific cell components and processes. In recent years, elemental imaging of biological samples using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is gaining more and more importance. Improvements concerning both spatial resolution (down to 1 µm) and signal-to-background ratio due to low-dispersion LA chambers make LA-ICP-MS particularly interesting for single cell analysis. Here LA-ICP-MS was applied for the imaging of individual cells to study the uptake and intracellular processing of metal-containing nanostructures. The cells were incubated with different NPs under varying experimental conditions and afterwards fixed with para-formaldehyde and dried for LA analysis. High-spatial resolution LA-ICP-MS was achieved by careful optimisation of the laser ablation parameters. Our findings show, that LA-ICP-MS is applicable to localize NP aggregates within cellular compartments. The uptake efficiency depends strongly on the physicochemical properties of the nanostructures as well as on the incubation conditions like concentration and incubation time. The results demonstrate the potential of LA-ICP-MS providing insight into nanoparticle-cell interaction dependent on experimental parameters. T2 - 14th European Workshop on Laser Ablation (EWLA) CY - Pau, France DA - 26.06.2018 KW - Laser ablation KW - ICP-MS KW - Imaging KW - Nanoparticle KW - Cell PY - 2018 AN - OPUS4-45570 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike A1 - Phukphatthanachai, Pranee T1 - Quantification of sulphur in copper metals by isotope dilution LA-ICP-MS using polyethylene frits N2 - Sulphur is one of the relevant impurities in copper and its alloys affecting their material properties. To ensure the quality of copper products, fast direct solid sampling techniques are very attractive. However, for the calibration suitable matrix reference materials are required. For the certification of such reference materials appropriate, SI-traceable analytical methods are essential. Therefore, a procedure was developed to quantify total sulphur in copper by combining the classical isotope dilution (ID) technique and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Here, for the first time, polyethylene (PE) frits were used to prepare appropriate solid samples for the sulphur quantification in copper metals (alloyed/unalloyed) by isotope dilution LA-ICP-MS. The properties of the PE frit meet the requirements as porous material with high absorption efficiency, thermal and chemical resistance as well as low sulphur blank. Different copper reference materials were used to develop and validate the procedure. The copper samples were spiked with 34S, digested with nitric acid and then the digests were absorbed on PE frits. After drying, the frits were analysed by LA-ICP-IDMS using a Nd:YAG laser at 213 nm coupled to an ICP sector field mass spectrometer. It could be demonstrated, that the sample solution dispersed on the frits did not influence the 32S/34S ratio significantly even though the sulphur intensities were fluctuating along the scanned lines. Relative standard deviations of the isotope ratios were below 5 % in average between three line scans (except for the pure spike solution and procedure blank). The measurement results were validated by comparing them with the results obtained by conventional ICP-IDMS after analyte-matrix separation. Plotting the mass fraction of sulphur in copper obtained by LA-ICP-IDMS versus those obtained by ICP-IDMS yields a linear curve with a correlation coefficient of 0.9999 showing a strong agreement between both techniques. The metrological traceability to the SI from the kg down to the sulphur mass fraction in copper is established by an unbroken chain of comparisons, each accompanied by an uncertainty budget. Thus, the measurement results are considered reliable, acceptable and comparable within the stated measurement uncertainty. T2 - 14th European Workshop on Laser Ablation (EWLA) CY - Pau, France DA - 26.06.2018 KW - ICP-MS KW - Laser ablation KW - Isotope dilution KW - Copper PY - 2018 AN - OPUS4-45569 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Drescher, D. A1 - Traub, Heike A1 - Büchner, T. A1 - Jakubowski, Norbert A1 - Kneipp, J. T1 - Properties of in situ generated gold nanoparticles in the cellular context N2 - Gold nanostructures that serve as probes for nanospectroscopic analysis of eukaryotic cell cultures can be obtained by the in situ reduction of tetrachloroauric acid (HAuCl4). To understand the formation process of such intracellularly grown particles depending on the incubation medium, the reaction was carried out with 3T3 fibroblast cells in three different incubation media, phosphate buffer, Dulbecco's Modified Eagle Medium (DMEM), and standard cell culture medium (DMEM with fetal calf serum). The size, the optical properties, the biomolecular corona, and the localization of the gold nanoparticles formed in situ vary for the different conditions. The combination of surface-enhanced Raman scattering (SERS) and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) microscopic mapping and transmission electron microscopy (TEM) provides complementary perspectives on plasmonic nanoparticles and non-plasmonic gold compounds inside the cells. While for the incubation with HAuCl4 in PBS, gold particles provide optical signals from the nucleus, the incubation in standard cell culture medium leads to scavenging of the toxic molecules and the formation of spots of high gold concentration in the cytoplasm without formation of SERS-active particles inside the cells. The biomolecular corona of nanoparticles formed in situ after incubation in buffer and DMEM differs, suggesting that different intracellular molecular species serve for reduction and stabilization. Comparison with data obtained from ready-made gold nanoparticles suggests complementary application of in situ and ex situ generated nanostructures for optical probing. KW - Nanoparticles KW - Laser ablation KW - ICP-MS KW - SERS KW - Cell PY - 2017 DO - https://doi.org/10.1039/C7NR04620K SN - 2040-3372 VL - 9 IS - 32 SP - 11647 EP - 11656 PB - The Royal Society of Chemistry RSC CY - Cambridge, UK AN - OPUS4-41871 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Studying cellular uptake of metal-containing nanoparticles by LA-ICP-MS N2 - Nanoparticles (NPs) have potential applications in medical diagnostics, imaging, drug delivery and other kinds of therapy. Furthermore, studies concerning nanoparticle uptake by cells are important for risk assessment. Size, shape and surface modification of the NPs determine the uptake rate and pathway into the cells, and therefore impact specific cell components and processes. Understanding the different uptake mechanisms and involved processes require sub-cellular resolution to determine, for example, whether the nanoparticles are reaching the nucleus. Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is an established quantitative multi-elemental analysis and mapping technique. However, sub-cellular imaging has traditionally been challenging to achieve due to a lack of sensitivity at small laser spots. But now novel laser ablation systems with improved sensitivity and washout time allow imaging at high lateral resolution with spot sizes down to 1 µm. Here LA-ICP-MS was applied for the imaging of individual fibroblast cells to study the uptake and intracellular processing of metal-containing NPs. To indicate cell morphology the local distribution of naturally occurring elements in cells like P and Zn was measured, too. Our results show that LA-ICP-MS can be used to localise nanoparticle aggregates within cellular compartments. The studied NPs accumulate in the perinuclear region in the course of intracellular processing, but do not enter the cell nucleus. The uptake efficiency depends strongly on the physico-chemical properties of the nanostructures as well as on the incubation conditions like concentration and incubation time. The potential of LA-ICP-MS for analysis at single cell level will be demonstrated. T2 - Euroanalysis 2017 CY - Stockholm, Sweden DA - 28.08.2017 KW - Laser ablation KW - ICP-MS KW - Nanoparticle KW - Cell PY - 2017 AN - OPUS4-41883 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Jakubowski, Norbert A1 - Müller, Larissa A1 - Traub, Heike A1 - Esteban-Fernandez, Diego A1 - Panne, Ulrich A1 - Herrmann, Antje A1 - Schellenberger, E. A1 - Kneipp, Janina T1 - Lecture 5 Bio- and immuno-imaging by use of laser ablation ICP-MS N2 - ICP-MS is a well-established analytical method which excels by high accuracy, high dynamic range and extremely low limits of detection for most metals. Furthermore ICP-MS offers a very high multi-element coverage so that many elements of the periodic table can be detected simultaneously. In this series of lectures, we want to focus on the historical developments, fundamentals, instrumentation and novel applications of ICP-MS in the life and material sciences. KW - Imaging KW - Laser ablation ICP-MS PY - 2017 AN - OPUS4-40943 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Müller, L. A1 - Traub, Heike A1 - Jakubowski, Norbert ED - Prof. Dr. Golloch, Alfred T1 - Novel applications of lanthanoides as analytical or diagnostic tools in the life sciences by ICP-MS-based techniques N2 - Inductively coupled plasma mass spectrometry (ICP-MS) is a well-established analytical method for multi-elemental analysis in particular for elements at trace and ultra-trace levels. It has found acceptance in various application areas during the last decade. ICP-MS is also more and more applied for detection in the life sciences. For these applications, ICP-MS excels by a high sensitivity, which is independent of the molecular structure of the analyte, a wide linear dynamic range and by excellent multi-element capabilities. Furthermore, methods based on ICP-MS offer simple quantification concepts, for which usually (liquid) standards are applied, low matrix effects compared to other conventional bioanalytical techniques, and relative limits of detection (LODs) in the low pg g−1 range and absolute LODs down to the attomol range. In this chapter, we focus on new applications where the multi-element capability of ICP-MS is used for detection of lanthanoides or rare earth elements, which are applied as elemental stains or tags of biomolecules and in particular of antibodies. KW - ICP-MS KW - Life sciences KW - Mass cytometry KW - Laser ablation (LA)-ICP-MS KW - Bioimaging PY - 2017 SN - 978-3-11-036523-8 SP - Chapter 11, 301 EP - 320 PB - De Gruyter AN - OPUS4-40244 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schannor, Mathias A1 - Oelze, Marcus A1 - Traub, Heike A1 - He, Yubei A1 - Schmidt, Robin A1 - Heidemann, Luisa A1 - Savic, Lynn Jeanette A1 - Vogl, Jochen A1 - Meermann, Björn T1 - Advancing Biomarker Research: In Situ Cu Isotope Analysis in Liver Tumors by LA-MC-ICP-MS N2 - Stable metal isotopes have received increasing attention as medical biomarkers due to their potential to detect changes in metal metabolism related to diseases. In particular, copper stable isotopes are a powerful tool to identify isotopic variation between tumors and healthy tissue, suggesting application in cancer diagnosis. However, potential mechanisms causing isotope fractionation, such as redox- or bond-forming reactions and interactions of metals during transmembrane import and export, are less well understood. Here, we established an in situ method using laser ablation-multicollector-inductively coupled plasma-mass spectrometry (LA-MC-ICP-MS) to advance our understanding of the underlying processes responsible for isotope fractionation between normal and diseased tissues. Gelatin-based bracketing standards and quality control reference materials, crucial for laser ablation analysis, were developed to allow correction for instrumentally induced isotope fractionation during LA-MC-ICP-MS analysis. Using such matrix-matched standards, the method achieved intermediate precisions for delta values of better than 0.15 ‰ (2 s) for inorganic reference materials and of better than 0.17 ‰ (2 s) for biological reference materials. The developed routine was tested on rabbit VX2 liver tumor samples, a model system resembling human hepatocellular carcinoma (HCC) used to study liver cancer. In situ Cu isotope compositions between healthy (𝛿65/63NIST976(Cu) = −1.5 ‰ to 0.2 ‰) and tumorous (𝛿65/63NIST976(Cu) = 0.0 ‰ to 1.3 ‰) liver tissue show distinct differences in their isotope ratios. The observed isotopic dichotomy is consistent with previous solution-based MC-ICP-MS work, showing enrichment of heavy 65Cu in cancer biopsies relative to healthy tissue. KW - Biomarker KW - Laser Ablation KW - Reference Material PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-626865 DO - https://doi.org/10.1021/acs.analchem.4c05626 SN - 1520-6882 VL - 97 IS - 8 SP - 4425 EP - 4432 PB - American Chemical Society (ACS) AN - OPUS4-62686 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Löwa, N. A1 - Golusda, L. A1 - Paclik, D. A1 - Traub, Heike A1 - Schannor, Mathias A1 - Saatz, Jessica A1 - Freise, C. A1 - Taupitz, M. A1 - Siegmund, B. A1 - Kühl, A. A. A1 - Wiekhorst, F. T1 - Magnetic particle spectroscopy for Eu-VSOP quantification in intestinal inflammation: Distinguishing nanoparticle signals from dietary contamination N2 - Magnetic nanoparticles are gaining increasing attention as a promising alternative to gadolinium-based contrast agents in magnetic resonance imaging, primarily due to their low toxicity. In this study, we investigated the use of magnetic iron oxide nanoparticles in mouse models of intestinal inflammation to assess their potential for detecting changes in the extracellular matrix. For magnetic quantification, we employed magnetic particle spectroscopy, which offers high sensitivity and minimal interference from biological tissue. However, we observed significant variations in magnetic signals within the intestine, as well as measurable signals in control animals, indicating possible magnetic contamination. By doping the nanoparticles with europium, we were able to confirm this suspicion through quantitative elemental analysis. Examination of mouse feed and feces allowed us to identify the source of contamination. Based on these findings, we developed a method to reliably distinguish genuine signals of magnetic nanoparticles from those caused by external magnetic contaminations. This approach is essential to ensure reliable results in future diagnostic and preclinical research. KW - ICP-MS KW - Nanoparticle KW - Magnetic particle spectroscopy KW - Quantification PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-642238 DO - https://doi.org/10.1039/D5NA00452G SN - 2516-0230 IS - 00452 SP - 1 EP - 10 PB - Royal Society of Chemistry (RSC) CY - Cambridge AN - OPUS4-64223 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Phukphatthanachai, Pranee A1 - Vogl, Jochen A1 - Traub, Heike A1 - Jakubowski, Norbert A1 - Panne, Ulrich T1 - A new approach of using polyethylene frits for the quantification of sulphur in copper metals by isotope dilution LA-ICP-MS and comparison with conventional IDMS techniques N2 - Polyethylene (PE) frits were used to quantify sulphur in copper and its alloys by isotope dilution combined with LA-ICP-MS as an alternative approach to conventional sample preparation: the copper samples were spiked, the spiked samples were dissolved, the resulting solutions were absorbed in the PE frits and finally the PE frits were analysed by LA-ICP-MS. A prerequisite for such a support material is a low sulphur blank and thus PE was selected for this purpose. The absorption efficiency of the PE frits was studied for varying sulphur amounts ranging from 2 mg S to 80 mg S showing that more than 99.5% of the loaded sulphur was absorbed by the frit. The so prepared PE frits were measured by LA-ICP-MS and yielded a good linearity (R2 ¼ 0.999) for the sulphur ion intensities corresponding to sulphur amounts up to 40 mg S; the associated sensitivity is approximately 3.4 x 10⁴ cps μg⁻¹ for ³²S. For the validation of the developed procedure the reference materials BAM-M376a, BAM-228 and BAM-227 were applied such that 2 μg S, 5 μg S and 11 μg S were absorbed in the PE frits, respectively. These samples were pre-quantified for the adsorbed sulphur amount by external calibration LA-ICP-MS yielding sulphur amounts of 0.9 μg, 5.1 μg and 8.5 μg (quantified for ³²S only), respectively. Relative Standard deviations of the isotope ratios were below 5% in average (n ¼ 3 lines) in all cases (except for the pure spike solution). These samples were then analysed by LA-ICP-IDMS and the measurement results were validated by comparing them with the results obtained by conventional ICP-IDMS. The obtained relative expanded measurement uncertainties ranged between 10% and 26%. Pearson's coefficient was used to express the correlation between both techniques; the obtained value was 0.999 demonstrating a strong correlation. Contrary to most published LA-ICP-IDMS procedures, the developed procedure enables SI-traceability for the measurement results. The metrological traceability to the SI for the sulphur mass fractions in copper was established by an unbroken chain of comparisons, each accompanied by an uncertainty budget. Thus, the measurement results are considered reliable, acceptable and comparable within the stated measurement uncertainty. The metrological traceability chain from the kg down to mass fraction in the samples obtained by LA-ICP-IDMS is presented as well. KW - Laser ablation KW - IDMS KW - Traceability KW - Uncertainty KW - Purity PY - 2018 DO - https://doi.org/10.1039/c8ja00116b SN - 0267-9477 SN - 1364-5544 VL - 33 IS - 9 SP - 1506 EP - 1517 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-45899 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Studying nanoparticle-cell interaction by ICP-MS based techniques N2 - Nanoparticles (NPs) have found a wide range of applications in research and industry. Thereby the interaction of NPs with biological systems like cells has become a major field of interest, ranging from medical applications to nanotoxicology. Size, shape and surface modification of the nanomaterials determine the uptake rate and pathway into the cells, and therefore impact specific cell components and processes. Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is an established quantitative multi-elemental analysis and mapping technique. In recent years, it was shown that LA-ICP-MS can provide quantitative as well as distribution information of metal containing nanoparticles (NPs) in cell samples. Here LA-ICP-MS was applied for the imaging of individual fibroblast cells to study the uptake and intracellular processing of NPs. Our results show that LA-ICP-MS can be used to localize nanoparticle aggregates within cellular compartments. The studied NPs accumulate in the perinuclear region in the course of intracellular processing, but do not enter the cell nucleus. The uptake efficiency depends strongly on the physico-chemical properties of the nanostructures as well as on the incubation conditions like concentration and incubation time. ICP-MS was used to determine the composition of the nanomaterials as well as the number of NPs in cells after acid digestion of the samples. T2 - 13. Symposium „Massenspektrometrische Verfahren der Element­spurenanalyse“ & 26. ICP-MS-Anwendertreffen CY - Berlin, Germany DA - 03.09.2018 KW - ICP-MS KW - Nanoparticle KW - Cell KW - Laser ablation PY - 2018 AN - OPUS4-45860 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - LA-ICP-MS for the analysis of nanoparticles in cells N2 - Many current nanomaterials can serve as contrast agents in cellular or tissue imaging, drug delivery vehicles or therapeutics, whereas others can cause toxic effects. In order to evaluate nano-bio interactions, the number of nanoparticles (NPs) inside cells as well as their localisation within cellular substructures is of particular interest. The cellular uptake depends on the primary characteristics of the NPs (e.g. size, shape, surface coating) and on the cell type. Laser ablation inductively coupled plasma mass spectrometry (LA‑ICP‑MS) is more and more used to study the NP pathway from uptake, via intracellular processing up to cell division. High-spatial resolution laser ablation at single cell level is achieved using novel low-dispersion LA chambers and by careful optimisation of laser energy, ablation frequency and scan speed at small laser spot sizes down to 1 µm. Different examples from BAM, Division 1.1 and cooperation partners using LA-ICP-MS to localize and quantify metal-containing nanoparticles are shown. The results demonstrate the potential of LA-ICP-MS providing insight into NP uptake, intracellular distribution and cell-to-cell variation. T2 - 13. Symposium "Massensprektrometrische Verfahren der Elementspurenanalyse" + 26. ICP-MS Anwendertreffen CY - Berlin, Germany DA - 03.09.2018 KW - Laser ablation KW - Cells KW - Nanoparticles KW - Imaging PY - 2018 AN - OPUS4-46440 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Drescher, Daniela A1 - Giesen, Charlotte A1 - Traub, Heike A1 - Panne, Ulrich A1 - Kneipp, Janina A1 - Jakubowski, Norbert T1 - Quantitative imaging of gold and silver nanoparticles in single eukaryotic cells by laser ablation ICP-MS N2 - Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was utilized for spatially resolved bioimaging of the distribution of silver and gold nanoparticles in individual fibroblast cells upon different incubation experiments. High spatial resolution was achieved by optimization of scan speed, ablation frequency, and laser energy. Nanoparticles are visualized with respect to cellular substructures and are found to accumulate in the perinuclear region with increasing incubation time. On the basis of matrix-matched calibration, we developed a method for quantification of the number of metal nanoparticles at the single-cell level. The results provide insight into nanoparticle/cell interactions and have implications for the development of analytical methods in tissue diagnostics and therapeutics. KW - Imaging KW - Cell KW - Nanoparticles KW - Laser ablation KW - ICP-MS PY - 2012 DO - https://doi.org/10.1021/ac302639c SN - 0003-2700 SN - 1520-6882 VL - 84 IS - 22 SP - 9684 EP - 9688 PB - American Chemical Society CY - Washington, DC AN - OPUS4-27440 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - LA-ICP-MS zur Analyse einzelner Zellen T2 - 23. ICPMS Anwendertreffen und 10. Symposium Massenspektrometrische Verfahren der Elementspurenanalyse CY - Tulln an der Donau, Austria DA - 2012-09-10 PY - 2012 AN - OPUS4-27480 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Evaluation of solution doped powder pellets for the analysis of pure copper using PP-TOFMS T2 - 6th International GD Day CY - Paris, France DA - 2012-09-21 PY - 2012 AN - OPUS4-27481 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Application of solution doped powder pellets for the analysis of pure copper using Plasma Profiling TOFMS T2 - 16. Anwendertreffen "Analytische Glimmentladungsspektrometrie" 2013 CY - Duisburg, Germany DA - 2013-04-24 PY - 2013 AN - OPUS4-28779 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Shigeta, K. A1 - Traub, Heike A1 - Panne, Ulrich A1 - Okino, A. A1 - Rottmann, L. A1 - Jakubowski, Norbert T1 - Application of a micro-droplet generator for an ICP-sector field mass spectrometer - optimization and analytical characterization N2 - A micro-droplet generator (µDG) sample introduction system was coupled to a sector field ICP-MS instrument to investigate the analytical figures of merit with respect to single cell analysis. The sector field instrument was operated for the first time in a fast scanning mode (E-scan) with the shortest time resolution of 100 µs to measure the single droplet time resolved and using the original detector in a pulse counting mode without modification of the existing electronics. For reduction of the droplet diameter a triple pulse mode of the droplet generator was applied and a droplet diameter down to 23 µm has been achieved for this investigation with a 100% transport efficiency of droplets. Signal duration times of single droplets of less than 500 µs have been measured. Overall detection efficiencies in the range of 10-3 counts per atom have been achieved and absolute limits of detection range between 120 ag for Fe and 1.1 ag for Mg as a mean value from 1000 droplet events. PY - 2013 DO - https://doi.org/10.1039/c2ja30207a SN - 0267-9477 SN - 1364-5544 VL - 28 IS - 5 SP - 646 EP - 656 PB - Royal Society of Chemistry CY - London AN - OPUS4-29447 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Studying cellular uptake and processing of nanoparticles by LA-ICP-MS T2 - European Winter Conference on Plasma Spectrochemistry - EWCPS 2015 CY - Münster, Germany DA - 2015-02-22 PY - 2015 AN - OPUS4-32748 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Traub, Heike ED - Milacic, R. ED - Scancar, J. ED - Goenaga-Infante, H. ED - Vidmar, J. T1 - Imaging of metal-based nanoparticles in tissue and cell samples by laser ablation inductively coupled plasma mass spectrometry N2 - Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is nowadays a versatile and powerful analytical method for direct solid sample analysis. The applicability has been demonstrated for a wide variety of samples covering hard and soft materials. In an imaging mode the technique provides quantitative information on the elemental distribution within a sample. LA-ICP-MS imaging is of particular interest in biomedical research as the distribution of an element gives valuable insight on uptake and distribution of essential and toxic trace elements, administered contrast agents as well es nanoparticles. LA-ICP-MS is therefore a powerful complement to other imaging techniques. Recent instrumental improvements, especially in sample chamber design, have contributed to better sensitivity and spatial resolution enabling subcellular imaging. The book chapter provides a comprehensive overview about spatially resolved localisation and quantification of various nanoparticles in cells and tissue thin sections by LA-ICP-MS. Furthermore, different sample preparation strategies and internal standardisation and calibration approaches for bioimaging by LA-ICP-MS are summarized and discussed. Metal-containing nanomaterials are used in numerous fields ranging from industrial applications to nanomedicine. Several studies have demonstrated that the physicochemical properties of nanoparticles have an impact on their pharmacokinetics, transfer and clearance. The high sensitivity and multielement capability of LA-ICP-MS enables the elucidation of interactions between tissue components and nanomaterials used as imaging probes or drug carriers. Potential toxic effects are investigated as well. Thus, LA imaging significantly supports the clinical translation of safe and efficient nanoparticles for diagnostic and therapeutic purposes. KW - Laser ablation KW - ICP-MS KW - Imaging KW - Nanoparticle KW - Nanomaterial KW - Tissue KW - Cell PY - 2021 SN - 978-0-323-85305-7 SN - 0166-526X VL - 93 SP - 173 EP - 240 PB - Elsevier CY - Amsterdam ET - 1 AN - OPUS4-52775 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Blanchard, V. A1 - Traub, Heike T1 - Central project for biochemical analysis of proteoglycans and glycosaminoglycans and for element-specific microscopy N2 - Nearly all disease processes are associated with variations of components of the extracellular matrix (ECM) that are typically observed during the development of inflammation. This concerns for example proteoglycans and their associated glycosaminoglycans (GAG), which have been shown to bind to cationic metal imaging probes due to their strong complexing activity. The complexing activity largely depends on the degree of GAG sulfation and/or carboxylation as well as on the GAG isomericity. In this central project, we investigate GAG structures from inflammatory disorders (namely cardiovascular diseases, inflammatory intestinal diseases and neuroinflammation) provided by researchers of the Collaborative Research Center at the molecular disaccharidic level using chromatographic and mass spectrometric methods. In parallel, the spatial localization and quantification of metal-based imaging probes are evaluated by LA-ICP-MS imaging. T2 - 1st International Symposium In vivo Visualization of Extracellular Matrix Pathology CY - Online Meeting DA - 27.05.2021 KW - Laser ablation KW - ICP-MS KW - MALDI PY - 2021 AN - OPUS4-52716 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Yang, Q.-C. A1 - Jochum, K.P. A1 - Stoll, B. A1 - Weis, U. A1 - Kuzmin, D. A1 - Wiedenbeck, M. A1 - Traub, Heike A1 - Andreae, M. O. T1 - BAM-S005 type A and B: new silicate reference glasses for microanalysis N2 - To test whether the silicate reference glasses BAM-S005-A and BAM-S005-B from BAM (The Federal Institute for Materials Research and Testing, Germany) are suitable materials for microanalysis, we investigated the homogeneity of these reference glasses using the microanalytical techniques EPMA, LA-ICP-MS and SIMS. Our study indicated that all major and most trace elements are homogeneously distributed at micrometre sampling scale in both types of glass. However, some trace elements (e.g., Cs, Cl, Cr, Mo and Ni) seem to be inhomogeneously distributed. We also determined the composition of BAM-S005-A and BAM-S005-B. The EPMA data of major elements confirmed the information values specified by the certificate. With the exception of Sr, Ba, Ce and Pb, our trace element data by LA-ICP-MS were also in agreement with the certified values within the stated uncertainty limits. The reasons for the discrepancy in these four elements are still unclear. In addition, we report new data for twenty-two further trace elements, for which the concentrations were not certified. Based on our investigation, we suggest that both of these materials are suitable for many microanalytical applications. KW - BAM-S005 KW - Microanalysis KW - Reference glasses KW - Homogeneity KW - Characterisation KW - Laser ablation ICP-MS KW - EPMA KW - SIMS KW - Glass KW - Reference material PY - 2012 DO - https://doi.org/10.1111/j.1751-908X.2012.00171.x SN - 1639-4488 SN - 1751-908X VL - 36 IS - 3 SP - 301 EP - 313 PB - Blackwell CY - Oxford AN - OPUS4-26563 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Phukphatthanachai, P. A1 - Panne, Ulrich A1 - Traub, Heike A1 - Pfeifer, Jens A1 - Vogl, Jochen T1 - Quantification of sulphur in copper and copper alloys by GDMS and LA-ICP-MS, demonstrating metrological traceability to the international system of units N2 - The quantification of the sulphur mass fraction in pure copper and copper alloys by GDMS and LA-ICP-MS revealed a lack of traceability mainly due to a lack of suitable certified reference materials for calibrating the instruments. Within this study GDMS and LA-ICP-MS were applied as routine analytical tools to quantify sulphur in copper samples by applying reference materials as calibrators, which were characterized for their sulphur mass fraction by IDMS beforehand. Different external calibration strategies were applied including a matrix cross type calibration. Both techniques with all calibration strategies were validated by using certified reference materials (others than those used for calibration) and good agreement with the reference values was achieved except for the matrix cross type calibration, for which the agreement was slightly worse. All measurement results were accompanied by an uncertainty statement. For GDMS, the relative expanded (k = 2) measurement uncertainty ranged from 3% to 7%, while for LA-ICP-MS it ranged from 11% to 33% when applying matrix-matched calibration in the sulphur mass fraction range between 25 mg kg-1 and 1300 mg kg-1. For cross-type calibration the relative expanded (k = 2) measurement uncertainty need to be increased to at least 12% for GDMS and to at least 54% for LA-ICP-MS to yield metrological compatibility with the reference values. The so obtained measurement results are traceable to the international system of units (SI) via IDMS reference values, which is clearly illustrated by the unbroken chain of calibrations in the metrological traceability scheme. KW - Sulfur KW - Copper KW - GDMS KW - LA-ICP-MS KW - Uncertainty KW - Traceability KW - SI PY - 2021 DO - https://doi.org/10.1039/d1ja00137j SN - 0267-9477 VL - 36 IS - 11 SP - 2404 EP - 2414 PB - Royal Society of Chemistry AN - OPUS4-53412 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Elemental mapping to study the interaction of MRI contrast agents with extracellular matrix components N2 - Non-specific Gd-based contrast agents (GBCAs) have long been routinely used in clinical magnetic resonance imaging (MRI) diagnostics. Nevertheless, the interaction of such contrast agents with tissue components is not yet fully understood. Typically, they go into extracellular space. The extracellular matrix (ECM) is a three-dimensional network of macromolecules providing structural and biochemical support of the surrounding cells in all mammalian tissues. It is composed of structural proteins (e.g., collagen, elastin) and proteoglycans, which consist of glycosaminoglycans (GAGs) covalently bound to a protein core. GAGs are long, linear polysaccharides composed of repeating disaccharide units that differ in molecular mass, disaccharide structure and degree of sulfation. Many diseases, including inflammation, fibrosis, and tumor invasion, are associated with characteristic ECM changes, especially at an early stage of disease development. As disease severity increases, the amount of one or more different GAG types in the ECM and the extent of GAG sulfation increases. Characteristic of GAGs is their ability to form complexes with cations, e.g., with lanthanides. Thus, GAGs could be a potential binding partner for GBCA molecules as a whole or for dechelated Gd. Currently, there are still many unanswered questions about the interaction of contrast agents with ECM components. In this study, therefore, the uptake and distribution of ionic Gd and various linear and macrocyclic GBCAs was investigated in spheroids as model systems mimicking the complex physiologically relevant tissue microenvironment. Chinese hamster ovary (CHO) cells and CRL-2242 cells, a CHO mutant that does not produce sulfated GAGs, were used to prepare spheroids. Afterwards the spheroids were incubated with gadolinium chloride and GBCAs. For elemental mapping laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-TOFMS) and synchrotron radiation nano X-ray fluorescence spectroscopy (syn-nanoXRF) were used. Although all spheroids were exposed to identical Gd concentrations, differences were observed in the spatial distribution and the amount of Gd taken up. After incubation with linear and macrocyclic GBCAs, Gd is detected in the interior of both types of spheroids. Furthermore, differences in the Gd amount were found depending on the GBCA used. In contrast, incubation with gadolinium chloride leads to an Gd enrichment in the outer regions of the spheroids as well as to much higher Gd contents compared to incubation with GBCAs. Both LA-ICP-TOFMS and syn-nanoXRF can make an important contribution to better understand the relationship between the affinity of GBCAs and ECM components. However, to elucidate such complex interactions, further studies are needed, also with other (bio-)analytical techniques. T2 - Euroanalysis 2025 CY - Barcelona, Spain DA - 31.08.2025 KW - ICP-MS KW - Laser ablation KW - Contrast agent KW - Spheroid KW - Extracellular matrix PY - 2025 AN - OPUS4-64143 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Theiner, S. A1 - Corte Rodriguez, M. A1 - Traub, Heike ED - Golloch, A. T1 - Novel applications of lanthanoids as analytical or diagnostic tools in the life sciences by ICP-MS based techniques N2 - Inductively coupled plasma-mass spectrometry (ICP-MS) is a well-established analytical method offering high sensitivity and multi-element analysis. ICP-MS has found acceptance in various application areas ranging from material analysis to applications in the life sciences. Within the last 15 years new strategies for the sensitive detection and accurate quantification of biomolecules in complex biomedical samples have been developed. Recent instrumental improvements have contributed to this progress. As most of the biomolecules do not contain endogenous metals etectable with ICP-MS, bioconjugation with artificial metal-containing tags based on metal-loaded chelate complexes or nanoparticles is increasingly applied to determine biomolecules indirectly. Especially, the combination of immunohistochemical workflows using lanthanoid-tagged antibodies and ICP-MS detection provides new insights in the complexity and interdependency of cellular processes. Single-cell ICP-MS, also termed as mass cytometry, allows high-dimensional analysis of biomarkers in cell populations at single-cell resolution. For that purpose, lanthanoid isotope labelled antibodies are used to detect their corresponding target molecules. The visualisation of the elemental distribution is possible with laser ablation ICP-MS (LA-ICPMS) at high spatial resolution. Especially, the combination of LA with ICP time-of-flight mass spectrometry, also referred to as imaging mass cytometry (IMC), opens new possibilities for multiparametric tissue imaging at the single-cell level and even below. The lanthanoid localisation and concentration can be linked to their conjugated antibody target providing valuable information about surface markers, intracellular signalling molecules to measure biological function, and the network state of an individual cell in a tissue. This book chapter focuses on new applications, where the multi-element capabilities of ICP-MS are used for the detection of lanthanoids applied as artificial elemental stains or tags for biomolecules and in particular antibodies. KW - ICP-MS KW - Laser ablation KW - Cell KW - Antibody KW - Immunohistochemistry KW - Lanthanoid KW - Mass cytometry KW - Imaging PY - 2022 SN - 978-3-11069-645-5 SN - 978-3-11069-636-3 DO - https://doi.org/10.1515/9783110696455-013 SP - 399 EP - 444 PB - De Gruyter CY - Berlin, Boston ET - 2. rev. and exten. edition AN - OPUS4-55118 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Püschel, S. A1 - Liestmann, Z. A1 - Kalusniak, S. A1 - Kränkel, C. A1 - Schulz, Andreas A1 - Traub, Heike A1 - Tanaka, H. T1 - Impact of Ho3+, Er3+, and Tm3+ on laser cooling of Yb:YLF N2 - Ytterbium-doped LiYF4 (Yb:YLF) is a promising material for all-solid-state optical cryocoolers, but the impact of foreign rare-earth impurities on the laser-cooling performance is not completely understood. In particular, Tm3+ has been reported to reduce the background absorption. This study quantitatively assesses the impact of Ho3+, Tm3+, and Er3+ impurities on laser-cooling of Yb:YLF by anti-Stokes fluorescence. We grew five Yb(5%):YLF crystals intentionally doped with tens of ppm levels of these impurities. Laser-induced thermal modulation spectroscopy tests confirmed that these rare-earth impurities reduce the external quantum efficiency of Yb:YLF without affecting the background absorption coefficient. Although Er3+ is a well-known quencher for Yb3+, Er3+ co-doping only slightly decreases the laser-cooling efficiency at low pump intensities but becomes detrimental at high pump intensities (>5 kW cm−2). However, this detrimental effect diminishes at lower temperatures, as evidenced by cooling an Er3+ co-doped crystal to the same minimum temperature of 144K as a solely Yb3+-doped crystal. Contrary to previous reports, Tm3+ proved to be the most detrimental among the three impurities. KW - ICP KW - Laser cooling KW - Impurity KW - LiYF4 KW - Crystal PY - 2024 DO - https://doi.org/10.1364/OME.538215 VL - 14 IS - 10 SP - 2334 EP - 2348 PB - Optica Publishing Group CY - Washington DC, USA AN - OPUS4-61046 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Scharek, Vera M. A1 - Kröger, Tommy A1 - Keil, Karin A1 - Traub, Heike A1 - Meermann, Björn T1 - A new elemental analytical approach for microplastic sum parameter analysis—ETV/ICP-MS with CO2 N2 - Microplastics (MPs) are pervasive environmental pollutants and are considered one of the main challenges of our time. However, a fast and comprehensive analytical approach for MP analysis in complex matrices traceable to SI units is still lacking. In this context, we report a fast screening tool for the sum parameter analysis of MPs using electrothermal vaporization (ETV) coupled to inductively coupled plasma-mass spectrometry (ICP-MS). In our proof-of-concept study, we observed size-independent detection of MPs as peaks above the 13C+ signal background in the nano- to micrometer range without limitations regarding the polymer type. Quantification of the 13C+ MP signals was accomplished via an external gas calibration utilizing dynamic dilution of carbon dioxide with argon, yielding recovery rates of 80–96% for MP reference material (RM) of polymer types commonly found in the environment. The applicability to a soil sample was demonstrated through spiking experiments with a polyethylene (PE) MP RM in soil. The limit of detection (LOD) was estimated to be 0.13 µg C, equaling the detection of a single spherical low-density-PE particle of about 70 µm, and a limit of quantification (LOQ) of 0.42 µg C. KW - ETV/ICP-MS KW - Mikroplastik KW - Summenparameter PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-646418 DO - https://doi.org/10.1007/s00216-025-06146-x SN - 1618-2642 SP - 1 EP - 10 PB - Springer CY - Berlin ; Heidelberg AN - OPUS4-64641 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bayerl, C. A1 - Shahryari, M. A1 - Reiter, R. A1 - Proß, V. A1 - Lehmann, K. A1 - Kühl, A. A. A1 - Becker, Dorit A1 - Schulz, Andreas A1 - Infante Duarte, C. A1 - Taupitz, M. A1 - Geisel, D. A1 - Tzschätzsch, H. A1 - Saatz, Jessica A1 - Traub, Heike A1 - Asbach, P. T1 - Quantitative Analysis of Gadolinium Deposits in Liver Tissue of Patients After Single or Multiple Gadolinium-based Contrast Agent Application N2 - Gadolinium-based contrast agents (GBCAs) are widely used in magnetic resonance imaging. Concerns exist regarding gadolinium deposition and its potential histopathologic tissue alterations, especially after repeated administrations of linear, less stable GBCAs. This study aimed to quantify gadolinium mass fractions in liver specimens of subjects exposed to GBCAs in correlation with histopathologic features. In this study, mass fractions of gadolinium in human liver specimens from 25 subjects who underwent liver tumor resection surgery and had received GBCA (1 to 9 times over 4 years), were quantitatively analyzed using inductively coupled plasma–mass spectrometry (ICP-MS). Histomorphology was assessed based on the nonalcoholic fatty liver disease activity score (NAS). Our results suggest that after intravenous administration of GBCA, a small fraction of gadolinium is retained in the liver over a time period of at least several weeks. A relationship was observed between Gadolinium retention and the number of GBCA administrations, but not with the cumulative dose and the degree of fatty liver disease. KW - ICP-MS KW - Contrast agent KW - Gadolinium KW - Liver PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-646608 DO - https://doi.org/10.1097/RLI.0000000000001254 SN - 1536-0210 SP - 1 EP - 10 PB - Lippincott Williams & Wilkins CY - Philadelphia, Pa. AN - OPUS4-64660 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Boyraz, B. A1 - Saatz, Jessica A1 - Pompös, I.-M. A1 - Gad, Michel A1 - Dernedde, J. A1 - Maier, A.-M. B. A1 - Moscovitz, O. A1 - Seeberger, P. H. A1 - Traub, Heike A1 - Tauber, R. T1 - Imaging Keratan Sulfate in Ocular Tissue Sections by Immunofluorescence Microscopy and LA-ICP-MS N2 - Carbohydrate-specific antibodies can serve as valuable tools to monitor alterations in the extracellular matrix resulting from pathologies. Here, the keratan sulfate-specific monoclonal antibody MZ15 was characterized in more detail by immunofluorescence microscopy as well as laser ablation ICP-MS using tissue cryosections and paraffin-embedded samples. Pretreatment with keratanase II prevented staining of samples and therefore demonstrated efficient enzymatic keratan sulfate degradation. Random fluorescent labeling and site-directed introduction of a metal cage into MZ15 were successful and allowed for a highly sensitive detection of the keratan sulfate landscape in the corneal stroma from rats and human tissue. KW - Laser ablation KW - Imaging KW - Glycosaminoglycan KW - ICP-MS KW - Immunohistochemistry KW - Immunofluorescence KW - Tissue PY - 2022 DO - https://doi.org/10.1021/acsabm.1c01240 VL - 5 IS - 2 SP - 853 EP - 861 PB - American Chemical Society CY - Washington AN - OPUS4-54341 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Unraveling the interaction of MRI contrast agents with tissue using LA ICP MS N2 - Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is increasingly used to study the distribution of metal-containing drugs, imaging probes and nanomaterials in connection with disease related changes and therapy progress. Additionally, biomolecules can be detected indirectly by using metal-tagged antibodies. The extracellular matrix (ECM) is, besides the cells, an important component of all body tissues. The macromolecular network of the ECM consists of structural proteins (e.g., collagen, elastin) and proteoglycans composed of highly negatively charged carbohydrates, the glycosaminoglycans (GAGs), which are covalently linked to a protein core. Many diseases, including inflammatory processes and tumors, are associated with characteristic ECM changes at an early stage. Recent studies have shown that contrast agents for magnetic resonance imaging (MRI), which are based on gadolinium containing chelate complexes or iron oxide nanoparticles, can bind themselves to ECM components. To elucidate the role of GAGs like keratan sulfate (KS) and its modification state in disease, highly specific tools are necessary. As a complement to conventional immunohistochemistry LA-ICP-MS was applied to investigate the distribution of KS in tissue thin sections using a well characterized anti-KS antibody labelled with metal ions. Furthermore, LA-ICP-MS was used for the detection of MRI contrast agents and the identification of their target cells and molecules in tissue samples from animal models, e.g. for cardiovascular diseases. The results show the possibilities of LA-ICP-MS for the elucidation of pathological tissue changes. T2 - European Workshop on Laser Ablation (EWLA 2022) CY - Berne, Switzerland DA - 12.07.2022 KW - Laser ablation KW - Imaging KW - ICP-MS KW - Antibody PY - 2022 AN - OPUS4-55315 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Laser Ablation ICP-ToF-MS to investigate the interaction of MRI contrast agents with extracellular matrix components N2 - Non-specific Gd-based contrast agents (GBCAs) have long been routinely used in clinical magnetic resonance imaging (MRI). However, the interaction of such contrast agents with tissue components is not yet fully understood. Alongside cells, the extracellular matrix (ECM) is an important component of mammalian tissue. It is a three-dimensional network of macromolecules that provides structural and biochemical support to the surrounding cells. Many diseases, including inflammation, fibrosis, and tumour invasion, are associated with characteristic ECM changes. The ECM consists of structural proteins (e.g., collagen, elastin) and proteoglycans, which are composed of glycosaminoglycans (GAGs) covalently linked to a protein core. GAGs are long, linear polysaccharides consisting of repeated disaccharide units widely varying in molecular mass, disaccharide structure, and sulfation degree. Characteristic of GAGs is their ability to form complexes with cations such as lanthanides. Thus, GAGs could be a potential binding partner for GBCA molecules as a whole or for dechelated Gd. Currently, there are still many unanswered questions about the interaction of contrast agents with ECM components. This study therefore investigated the uptake and distribution of different GBCAs in spheroids that mimic biological tissue and have different ECM expressions. Chinese hamster ovary (CHO) cells and GAG-depleted CRL-2242 cells were used to prepare spheroids. These were then incubated for several minutes with gadolinium chloride and various linear and macrocyclic GBCAs. Cryosections of the spheroids were used for imaging measurements with a low-dispersion laser ablation system coupled to an inductively coupled plasma time-of-flight mass spectrometer (LA/ICP-ToF-MS). Gelatine doped with multi-element solutions was used for matrix-matched quantification of Gd and other relevant elements such as Cu, Fe and Zn. Although all spheroids were incubated with identical Gd concentrations, significant differences in the amount of Gd taken up were observed. Gadolinium chloride is absorbed more strongly than the contrast agents and accumulates mainly in the outer regions of the spheroids. In contrast, after incubation with the linear and macrocyclic contrast agents, Gd is detected in the interior of both types of spheroids. T2 - European Workshop on Laser Ablation, EWLA 2024 CY - Ghent, Belgium DA - 02.07.2024 KW - ICP-MS KW - Laser ablation KW - Spheroid KW - Contrast agent PY - 2024 AN - OPUS4-60575 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pisonero, J. A1 - Bouzas-Ramos, D. A1 - Traub, Heike A1 - Cappella, Brunero A1 - Alvarez-Llamas, C. A1 - Richter, Silke A1 - Mayo, J. C. A1 - Costa-Fernandez, J. M. A1 - Bordel, N. A1 - Jakubowski, Norbert T1 - Critical evaluation of fast and highly resolved elemental distribution in single cells using LA-ICP-SFMS N2 - The analytical potential of a nanosecond laser ablation inductively coupled plasma mass spectrometer (ns-LA-ICP-SFMS) system, equipped with an ultra-fast wash-out ablation chamber, is critically investigated for fast and highly spatially resolved (∼μm) qualitative elemental distribution within single cells. Initially, a low surface roughness (< 10 nm) thin In–SnO2 layer (total coating thickness ∼200 nm) deposited on glass is employed to investigate the size, morphology and overlapping of laser-induced craters obtained at different laser repetition rates, making use of Atomic Force Microscopy (AFM). Conical craters with a surface diameter of about 2 µm and depths of about 100 nm were measured after a single laser shot. Furthermore, the influence of the sampling distance (i.e. distance between the sample surface and the inner sniffer of the ablation chamber) on the LA-ICP-MS ion signal wash-out time is evaluated. A significant decrease of the transient 120Sn+ ion signal is noticed after slight variations (±200 μm) around the optimum sampling position. Ultra-fast wash-outs (< 10 ms) are achieved reducing the aerosol mixing from consecutive laser shots even when operating the laser at high repetition rates (25 – 100 Hz). Fast and highly spatially resolved images of elemental distribution within mouse embryonic fibroblast cells (NIH/3T3 fibroblast cells) and human cervical carcinoma cells (HeLa cells), incubated with gold nanoparticles (Au NPs) and Cd-based quantum dots (QDs), respectively, are determined at the optimized operating conditions. Elemental distribution of Au and Cd in single cells is achieved using a high scanning speed (50 µm/s) and high repetition rate (100 Hz). The results obtained for the distribution of fluorescent Cd-based QDs within the HeLa cells are in good agreement with those obtained by confocal microscopy. The size, morphology and overlapping of laser-induced craters in the fixed cells are also investigated using AFM, observing conical craters with a surface diameter of about 2.5 µm and depths of about 800 nm after a single laser shot. KW - Laser ablation KW - ICP-MS KW - Nanoparticle KW - Atomic Force Microscopy KW - Cell PY - 2018 DO - https://doi.org/10.1039/c8ja00096d SP - 1 EP - 9 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-45564 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pisonero, J. A1 - Traub, Heike A1 - Cappella, Brunero A1 - Álvarez-Llamas, C. A1 - Méndez, A. A1 - Richter, Silke A1 - Ruiz Encinar, J. A1 - Costa-Fernandez, J. M. A1 - Bordel, N. T1 - Exploring quantitative cellular biomaging and assessment of CdSe/ZnS quantum dots cellular uptake in single cells, using ns-LA-ICP-SFMS N2 - High spatially resolved quantitative bioimaging of CdSe/ZnS Quantum Dots uptake in two kinds of cells is investigated combining laser ablation inductively coupled plasma mass spectrometry and the spatially resolved analysis of dried pL-droplets from a solution with a known concentration of Quantum Dots. Single cells and dried pL-droplets are morphologically characterized by Atomic Force Microscopy. A number concentration of CdSe/ZnS QDs between 3.5 104 and 48 104 is estimated to be uptaken by several selected single cells, after being incubated in the presence of a QDs suspension added to a standard cell culture medium. Mono-elemental bioimaging at subcellular resolution seems to show a higher number concentration of the CdSe/ZnS QDs in the cytosol around the cell nucleus. KW - LA-ICP-SFMS KW - Fast single pulse response KW - Quantitative bioimaging KW - Cellular uptake KW - HT22 KW - HeLa KW - Single cell KW - pL-droplets KW - CdSe/ZnS quantum Dots KW - AFM PY - 2021 DO - https://doi.org/10.1016/j.talanta.2021.122162 SN - 0039-9140 VL - 227 SP - 122162 PB - Elsevier B.V. AN - OPUS4-52121 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - LA-ICP-TOFMS to study the interaction of MRI contrast agents with extracellular matrix components N2 - Non-specific Gd-based contrast agents (GBCAs) have been used in clinical magnetic resonance imaging (MRI) for more than 35 years. However, the interaction of such contrast agents with tissue components is not yet fully understood. Many diseases are associated with characteristic changes of the extracellular matrix (ECM). The ECM is a three-dimensional network of macromolecules providing structural and biochemical support of the surrounding cells in all mammalian tissues. It is composed of structural proteins (e.g., collagen, elastin) and proteoglycans, which consist of glycosaminoglycans (GAGs) covalently bound to a protein core. GAGs are long, linear polysaccharides composed of repeating disaccharide units that differ in molecular mass, disaccharide structure and degree of sulfation. GAGs are also characterized by their ability to form complexes with cations such as lanthanides. Thus, GAGs could be a potential binding partner for GBCAs as a whole or for dechelated Gd. Laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-TOFMS) was used to investigate the uptake and distribution of ionic Gd and various linear and macrocyclic GBCAs in spheroids mimicking biological tissue and exhibiting different ECM expressions. In addition to Gd, other relevant elements such as Cu, Fe, P and Zn were also monitored. Spheroids from Chinese hamster ovary (CHO) cells and GAG-depleted CRL-2242 cells were incubated with gadolinium chloride and various GBCAs. Although all spheroids were exposed to identical Gd concentrations, differences were observed in the spatial distribution and the amount of Gd taken up. After incubation with linear and macrocyclic GBCAs, Gd is detected in the interior of both types of spheroids. In contrast, incubation with gadolinium chloride leads to an enrichment in the outer regions of the spheroids as well as to much higher Gd contents compared to incubation with GBCAs. LA-ICP-TOFMS can make an important contribution to better understand the relationship between the affinity of GBCAs and ECM components such as GAGs. However, to elucidate such complex interactions, further studies are needed, also with other (bio-)analytical techniques. T2 - 20th European Winter Conference on Plasma Spectrochemistry (EWCPS-2025) CY - Berlin, Germany DA - 02.03.2025 KW - ICP-MS KW - Laser ablation KW - Contrast agent KW - Spheroid KW - Extracellular matrix PY - 2025 AN - OPUS4-62692 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - LA-ICP-MS investigation of the the interaction of MRI contrast agents with extracellular matrix components N2 - In clinical magnetic resonance imaging, non-specific Gd-based contrast agents (GBCAs) are frequently used to improve image quality. However, the interaction of GBCAs with tissue components is not yet fully understood. Many diseases, including inflammation, fibrosis, and tumor invasion, are associated with characteristic changes of the extracellular matrix (ECM). The ECM is a three-dimensional scaffold that embeds the cells of all mammalian tissues. It is composed of structural proteins (e.g., collagen, elastin) and proteoglycans, which consist of glycosaminoglycans (GAGs) covalently bound to a protein core. GAGs are characterized by their ability to form complexes with cations such as lanthanides. Thus, GAGs could be a potential binding partner for GBCAs as a whole or for dechelated Gd. Laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA/ICP-ToF-MS) was used to investigate the uptake and distribution of different GBCAs in spheroids mimicking biological tissue and exhibiting different ECM expressions. Spheroids from Chinese hamster ovary (CHO) cells and GAG-depleted CRL-2242 cells were incubated with gadolinium chloride and various linear and macrocyclic GBCAs. Although all spheroids were exposed to identical Gd concentrations, differences in the amount of Gd taken up were observed. Gadolinium chloride is more strongly absorbed and accumulates mainly in the outer regions of the spheroids. In contrast, after incubation with linear and macrocyclic GBCAs, Gd is detected in the interior of both types of spheroids. Furthermore, differences in the Gd amount were found depending on the GBCA used. However, further studies are needed to elucidate such complex interactions, also using other (bio)analytical techniques. T2 - 2nd Annual Conference on Mass Spectrometry Imaging and Integrated Topics, IMSIS-2024 CY - Münster, Germany DA - 09.09.2024 KW - ICP-MS KW - Laser ablation KW - Contrast agent KW - Spheroid KW - Extracellular matrix PY - 2024 AN - OPUS4-61049 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Meermann, Björn A1 - Lisec, Jan A1 - Jaeger, Carsten A1 - Saatz, Jessica A1 - Traub, Heike A1 - von der Au, Marcus T1 - Mehr Analyten, kleinere Proben N2 - Molekülmassenspektrometrie entwickelt sich weg von klassischer Target- hin zu Nontarget-Analytik. Elementmassenspektrometrie liefert hohe Ortsauflösung beim Element-Imaging und analysiert einzelne Zellen. Aufgrund der Fortschritte bei den Geräten für Timeof-Flight-Massenspektrometrie mit induktiv gekoppeltem Plasma (ICPToF-MS) lässt sich das gesamte Periodensystem der Elemente in kurzen transienten Signalen quasi-simultan massenspektrometrisch erfassen. KW - Massenspektrometrie KW - Non-target KW - ICP-ToF-MS KW - Laser Ablation/Imaging PY - 2021 VL - 69 IS - Juni SP - 64 EP - 67 PB - Wiley-VCH AN - OPUS4-52800 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Traub, Heike A1 - Win, Tin A1 - Lück, Detlef A1 - Koch, Matthias A1 - Becker, Roland T1 - Evaluation and Development of Methods for the Analysis of Soils according to § 8 of the German Federal Soil Protection Act T2 - 7th International FZK/TNO Conference on Contaminated Soil ; 7th ConSoil 2000 CY - Leipzig, Germany DA - 2000-09-18 KW - Soil KW - Heavy metals KW - Cyanide KW - Chromium KW - Organic contaminants KW - Analytical methods KW - Standardization KW - National law PY - 2000 SN - 0-7277-2954-3 VL - 2 SP - 904 EP - 905 PB - Telford CY - London AN - OPUS4-876 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Traub, Heike A1 - Koch, Matthias A1 - Lück, Detlef A1 - Win, Tin A1 - Lehnik-Habrink, Petra A1 - Schultze, Karin A1 - Saring, U. A1 - Plagemann, R. T1 - Evaluierung von Verfahren für die Untersuchung von Böden nach § 8 Bundes-Bodenschutzgesetz (BBodSchG) (Forschungsbericht 299 71 224 / UBA-FB 000303) N2 - Evaluation of methods for the analysis of soils according to § 8 of the German Federal Soil Protection Act (BBodSchG) The German Federal Soil Protection Act establishes the conditions for effective soil protection and remediation of contaminated sites. In the German Federal Soil Protection and Contaminated Sites Ordinance (BBodSchV) limiting values and methods for the determination of environmentally harmful substances in soils are fixed. The aim of this project was to evaluate selected methods by comparative investigations and proficiency testing schemes. New methods for the determination of inorganic and organic pollutants should be developed and compared with the existing standard methods. Despite the widespread use of ICP-OES up to now no national or international standard is available for the determination of heavy metals in soil extracts with this analytical method. The influence of spectral and non spectral interferences on the accuracy of the results was systematically investigated, especially based on aqua regia soil extracts. Analyte concentration equivalents were determined, too. Based on these results a proposal for a standard was submitted to the corresponding working group of ISO TC 190.[...] KW - Evaluierung von Analyseverfahren KW - ICP-OES KW - Chrom(VI) KW - Cyanide KW - Säulenelution KW - Bodenluft KW - Vor-Ort-Analytik KW - PAK KW - OCP KW - PCB KW - PCP KW - Referenzmaterialien KW - Messunsicherheit PY - 2002 UR - http://www.umweltbundesamt.de/publikationen/evaluierung-von-verfahren-fuer-untersuchung-von SN - 1862-4804 SN - 0722-186X IS - 32 SP - 1 EP - 339 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-1760 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Büchner, T. A1 - Drescher, D. A1 - Merk, V. A1 - Traub, Heike A1 - Guttmann, P. A1 - Werner, St. A1 - Jakubowski, Norbert A1 - Schneider, G. A1 - Kneipp, J. T1 - Biomolecular environment, quantification, and intracellular interaction of multifunctional magnetic SERS nanoprobes N2 - Multifunctional composite nanoprobes consisting of iron oxide nanoparticles linked to silver and gold nanoparticles, Ag–Magnetite and Au–Magnetite, respectively, were introduced by endocytic uptake into cultured fibroblast cells. The cells containing the non-toxic nanoprobes were shown to be displaceable in an external magnetic field and can be manipulated in microfluidic channels. The distribution of the composite nanostructures that are contained in the endosomal system is discussed on the basis of surfaceenhanced Raman scattering (SERS) mapping, quantitative laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) micromapping, and cryo soft X-ray tomography (cryo soft-XRT). Cryo soft-XRT of intact, vitrified cells reveals that the composite nanoprobes form intra-endosomal aggregates. The nanoprobes provide SERS signals from the biomolecular composition of their surface in the endosomal environment. The SERS data indicate the high stability of the nanoprobes and of their plasmonic properties in the harsh environment of endosomes and lysosomes. The spectra point at the molecular composition at the surface of the Ag–Magnetite and Au–Magnetite nanostructures that is very similar to that of other Composite structures, but different from the composition of pure silver and gold SERS nanoprobes used for intracellular investigations. As shown by the LA-ICP-MS data, the uptake efficiency of the magnetite composites is approximately two to three times higher than that of the pure gold and silver nanoparticles. KW - Nanoparticles KW - SERS KW - Cell KW - LA-ICP-MS KW - X-ray tomography PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-371811 DO - https://doi.org/10.1039/c6an00890a SN - 0003-2654 VL - 141 IS - 17 SP - 5096 EP - 5106 PB - Royal Society of Chemistry CY - Cambridge, UK AN - OPUS4-37181 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Imaging of biological samples by LA-ICP-MS N2 - In recent years, elemental imaging of biological samples like tissue thin sections using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is gaining more and more importance. Improvements concerning spatial resolution as well as signal-to-background ratio due to low-dispersion sample chambers make LA-ICP-MS also interesting for single cell analysis. To evaluate the interaction of nanoparticles (NPs) with cells LA-ICP-MS was applied for the imaging of individual cells. Our findings show, that NP aggregates can be localized within cellular compartments. The uptake efficiency depends strongly on the physico-chemical properties of the nanostructures (size, chemical composition, surface modification), as well as on the incubation conditions (concentration, time). Moreover, LA-ICP-MS is increasingly becoming an important complementary technique in bioanalysis by using element-tagging strategies to determine biomolecules indirectly. Based on the specific binding between antibodies and their corresponding antigens, proteins and peptides can be detected in tissue or cells using tagged antibodies. As artificial tags metal chelates loaded with lanthanides, polymer-based elemental tags or metal-containing nanoparticles can be used. Thereby LA-ICP-MS is a sensitive detection tool for multiplexed immuno-histochemistry of tissue and cell samples. Our results demonstrate the potential of LA-ICP-MS to investigate the distribution of naturally occurring elements, administered agents as well as biomolecules by using metal-tagged antibodies. T2 - Workshop on tandem LIBS/LA-ICP-MS 2019 CY - Berlin, Germany DA - 18.11.2019 KW - Laser ablation KW - ICP-MS KW - Nanoparticles KW - Imaging PY - 2019 AN - OPUS4-49704 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Arakawa, Akihiro A1 - Jakubowski, Norbert A1 - Koellensperger, G. A1 - Theiner, S. A1 - Schweikert, A. A1 - Flemig, Sabine A1 - Iwahata, D. A1 - Traub, Heike A1 - Hirata, T. T1 - Imaging of Ag NP transport through collagen-rich microstructures in fibroblast multicellular spheroids by high-resolution laser ablation inductively coupled plasma time-of-flight mass spectrometry N2 - We investigated the penetration of silver nanoparticles (Ag NPs) into a three-dimensional in vitro tissue analog using NPs with various sizes and surface coatings, and with different incubation times. A high-Resolution laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) time-of-flight (TOF) instrument was applied for imaging the distributions of elements in thin sample sections (20 μm thick). A fibroblast multicellular spheroid (MCS) was selected as the model system and cultured for more than 8 days to produce a natural barrier formed by the extracellular matrix containing collagen. The MCS was then exposed for up to 48 h to one of four types of Ag NPs (∅ 5 nm citrate coated, ∅ 20 nm citrate coated, ∅ 20 nm polyvinylpyrrolidone coated, and ∅ 50 nm citrate coated). Imaging showed that the penetration pathway was strongly related to steric networks formed by collagen fibrils, and Ag NPs with a hydrodynamic diameter of more than 41 nm were completely trapped in an outer rim of the MCSs even after incubation for 48 h. In addition, we examined the impact of these NPs on essential elements (P, Fe, Cu, and Zn) in areas of Ag NP accumulation. We observed a linear increase at the sub-femtogram level in the total concentration of Cu (fg per pixel) in samples treated with small or large Ag NPs (∅ 5 nm or ∅ 50 nm) for 48 h. KW - Nanoparticle KW - Laser ablation KW - ICP-MS KW - Imaging KW - Cell PY - 2019 DO - https://doi.org/10.1039/c9an00856j SN - 0003-2654 VL - 144 IS - 16 SP - 4935 EP - 4942 PB - Royal Society of Chemistry RSC CY - Cambridge AN - OPUS4-48531 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pisonero, J. A1 - Bouzas-Ramos, D. A1 - Traub, Heike A1 - Cappella, Brunero A1 - Álvarez-Llamas, C. A1 - Richter, Silke A1 - Mayo, J. C. A1 - Costa-Fernandez, J. M. A1 - Bordel, N. A1 - Jakubowski, Norbert T1 - Critical evaluation of fast and highly resolved elemental distribution in single cells using LA-ICP-SFMS N2 - The analytical potential of a nanosecond laser ablation coupled plasma mass spectrometer (ns-LA-ICP-SFMS)system is investigated for fast and highly spatially resolved (~µm) elemental distribution within single cells. The size, morphology and overlapping of laser-induced craters has been investigated with Atomic Force Microscopy (AFM). KW - Atomic Force Microscopy KW - Laser Ablation KW - Elemental Distribution PY - 2019 DO - https://doi.org/10.1039/c8ja00096d SN - 0267-9477 VL - 34 IS - 4 SP - 655 EP - 663 PB - RSC AN - OPUS4-48549 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Arakawa, Akihiro A1 - Jakubowski, Norbert A1 - Koellensperger, G. A1 - Theiner, S. A1 - Schweikert, A. A1 - Flemig, Sabine A1 - Iwahata, D. A1 - Traub, Heike A1 - Hirata, T. T1 - Quantitative Imaging of Silver Nanoparticles and Essential Elements in Thin Sections of Fibroblast Multicellular Spheroids by High Resolution Laser Ablation Inductively Coupled Plasma Time-of-Flight Mass Spectrometry N2 - We applied high resolution laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-TOF-MS) with cellular spatial resolution for bioimaging of nanoparticles uptaken by fibroblast multicellular spheroids (MCS). This was used to quantitatively investigate interactions of silver nanoparticles (Ag NPs) and the distributions of intrinsic minerals and biologically relevant elements within thin sections of a fibroblast MCS as a three-dimensional in vitro tissue model. We designed matrix-matched calibration standards for this purpose and printed them using a noncontact piezo-driven array spotter with a Ag NP suspension and multielement standards. The limits of detection for Ag, Mg, P, K, Mn, Fe, Co, Cu, and Zn were at the femtogram (fg) level, which is sufficient to investigate intrinsic minerals in thin MCS sections (20 μm thick). After incubation for 48 h, Ag NPs were enriched in the outer rim of the MCS but not detected in the core. The localization of Ag NPs was inhomogeneous in the outer rim, and they were colocalized with a single-cell-like structure visualized by Fe distribution (pixel size of elemental images: 5 × 0.5 μm). The quantitative value for the total mass of Ag NPs in a thin section by the present method agreed with that obtained by ICP-sector field (SF)-MS with a liquid mode after acid digestion. KW - Laser ablation KW - ICP-MS KW - Imaging KW - Nanoparticle KW - Cell KW - Spheroid PY - 2019 UR - https://pubs.acs.org/doi/10.1021/acs.analchem.9b02239 DO - https://doi.org/10.1021/acs.analchem.9b02239 SN - 0003-2700 VL - 91 IS - 15 SP - 10197 EP - 10203 PB - American Chemical Society, ACS Publications CY - Washington D.C. AN - OPUS4-48719 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Arakawa, Akihiro A1 - Jakubowski, Norbert A1 - Flemig, Sabine A1 - Koellensperger, G. A1 - Rusz, M. A1 - Iwahata, D. A1 - Traub, Heike A1 - Hirata, T. T1 - High-resolution laser ablation inductively coupled plasma mass spectrometry used to study transport of metallic nanoparticles through collagen-rich microstructures in fibroblast multicellular spheroids N2 - We have efficiently produced collagen-rich microstructures in fibroblast multicellular spheroids (MCSs) as a three-dimensional in vitro tissue analog to investigate silver (Ag) nanoparticle (NP) penetration. The MCS production was examined by changing the seeding cell number (500 to 40,000 cells) and the growth period (1 to 10 days). MCSs were incubated with Ag NP suspensions with a concentration of 5 μg/mL for 24 h. For this study, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used to visualize Ag NP localization quantitatively. Thin sections of MCSs were analyzed by LA-ICP-MS with a laser spot size of 8 μm to image distributions of 109Ag, 31P, 63Cu, 66Zn, and 79Br. A calibration using a NP suspension was applied to convert the measured Ag intensity into the number of NPs present. The determined numbers of NPs ranged from 30 to 7200 particles in an outer rim of MCS. The particle distribution was clearly correlated with the presence of 31P and 66Zn and was localized in the outer rim of proliferating cells with a width that was equal to about twice the diameter of single cells. Moreover, abundant collagens were found in the outer rim of MCSs. For only the highest seeding cell number, NPs were completely captured at the outer rim, in a natural barrier reducing particle transport, whereas Eosin (79Br) used as a probe of small molecules penetrated into the core of MCSs already after 1 min of exposure. KW - Laser ablation KW - ICP-MS KW - Nanoparticle KW - Cell KW - Speroid PY - 2019 DO - https://doi.org/10.1007/s00216-019-01827-w SN - 1618-2642 SN - 1618-2650 VL - 411 IS - 16 SP - 3497 EP - 3506 PB - Springer CY - Berlin, Heidelberg AN - OPUS4-47900 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Elemental imaging by laser ablation ICP-MS N2 - Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is nowadays an established multi-elemental analysis and mapping technique. It was shown that LA-ICP-MS can visualize the elemental distribution within tissue thin sections or cell samples. Quantification is possible by using appropriate matrix-matched calibration samples. Besides naturally occurring elements and metals from contrast agents, biomolecules using metal-tagged antibodies were detected in different bio-medical samples. By combining the results with findings from histology, magnetic resonance imaging (MRI) and other techniques disease related changes like alterations of the extracellular matrix can be investigated. T2 - 4th Colloquium of CRC 1340 "Matrix in Vision" CY - Berlin, Germany DA - 09.04.2019 KW - Laser ablation KW - ICP-MS KW - Imaging PY - 2019 AN - OPUS4-47752 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Piechotta, Christian A1 - Iznaguen, Hassan A1 - Traub, Heike A1 - Feldmann, Ines A1 - Köppen, Robert A1 - Witt, Angelika A1 - Jung, Christian A1 - Becker, Roland A1 - Oleszak, Katrin A1 - Bücker, Michael A1 - Urban, Klaus A1 - Reger, Christian A1 - Ostermann, Markus T1 - Bewitterungsszenarien im Vergleich – Veränderungen in der Oberflächenmorphologie von Polypropylen (PP) und Polystyrol (PS) unter dem Aspekt des Austrags von polybromierten Flammschutzmitteln N2 - Gegenstand der vorzustellenden Arbeiten ist die Prüfung der Umwelt-beständigkeit und -verträglichkeit von Materialien und Produkten hinsichtlich der Emission von potenziellen Schadstoffen in die Umwelt. Hierzu werden chemisch-physikalische Einflüsse (Bewitterung) und mikrobielle Beanspruchungen an Modellmaterialien evaluiert. So werden die Freisetzungsraten von Schadstoffen in Abhängigkeit der Beanspruchung beschrieben. Als Modellmaterialien kommen die Polymere Polystyrol (PS) und Polypropylen (PP) zum Einsatz. Synergistische Effekte der Bewitterungsparameter und der mikrobiologischen Beanspruchung sollen dabei ebenso betrachtet werden, wie die gezielte Alterung. Auch findet eine Beschreibung des Verhaltens der ausgetragenen Schadstoffe in den Umweltkompartimenten Boden oder Wasser statt. Hier sind mit Hilfe der zu entwickelnden Screening- und non-Target-Analyseverfahren die Transformation und der Metabolismus durch Mikroorganismen zu beschreiben. Aus den Ergebnissen sollen Korrelationen zwischen den künstlichen Alterungsverfahren und realen Szenarien abgeleitet werden. T2 - 47. Jahrestagung der GUS CY - Blankenloch-Stutensee, Germany DA - 21.03.2018 KW - Schadstoffaustrag KW - Umweltsimulation KW - Bewitterung PY - 2018 SN - 978-981-18507-2-7 VL - 47 SP - 115 EP - 128 AN - OPUS4-49802 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -