TY - JOUR A1 - Matschat, Ralf A1 - Czerwensky, Michael A1 - Traub, Heike A1 - Heinrich, Hans-Joachim A1 - Kipphardt, Heinrich T1 - Special new techniques of atomic spectrometric methods for trace analysis of high purity metals JF - Matériaux et techniques PY - 2003 SN - 0032-6895 SN - 1778-3771 VL - 91 IS - Décembre SP - 37 EP - 50, N° Hors Série CY - Paris AN - OPUS4-6188 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Matschat, Ralf A1 - Haßler, J. A1 - Traub, Heike A1 - Dette, Angelika T1 - Multielement trace determination in SiC powders: assessment of interlaboratory comparisons aimed at the validation and standardization of analytical procedures with direct solid sampling based on ETV ICP OES and DC arc OES JF - Analytical and bioanalytical chemistry N2 - The members of the committee NMP 264 Chemical analysis of non-oxidic raw and basic materials of the German Standards Institute (DIN) have organized two interlaboratory comparisons for multielement determination of trace elements in silicon carbide (SiC) powders via direct solid sampling methods. One of the interlaboratory comparisons was based on the application of inductively coupled plasma optical emission spectrometry with electrothermal vaporization (ETV ICP OES), and the other on the application of optical emission spectrometry with direct current arc (DC arc OES). The interlaboratory comparisons were organized and performed in the framework of the development of two standards related to the determination of mass fractions of metallic impurities in powders and grain sizes of ceramic raw and basic materials by both methods. SiC powders were used as typical examples of this category of material. The aim of the interlaboratory comparisons was to determine the repeatability and reproducibility of both analytical methods to be standardized. This was an important contribution to the practical applicability of both draft standards. Eight laboratories participated in the interlaboratory comparison with ETV ICP OES and nine in the interlaboratory comparison with DC arc OES. Ten analytes were investigated by ETV ICP OES and eleven by DC arc OES. Six different SiC powders were used for the calibration. The mass fractions of their relevant trace elements were determined after wet chemical digestion. All participants followed the analytical requirements described in the draft standards. In the calculation process, three of the calibration materials were used successively as analytical samples. This was managed in the following manner: the material that had just been used as the analytical sample was excluded from the calibration, so the five other materials were used to establish the calibration plot. The results from the interlaboratory comparisons were summarized and used to determine the repeatability and the reproducibility (expressed as standard deviations) of both methods. The calculation was carried out according to the related standard. The results are specified and discussed in this paper, as are the optimized analytical conditions determined and used by the authors of this paper. For both methods, the repeatability relative standard deviations were <25%, usually ~10%, and the reproducibility relative standard deviations were <35%, usually ~15%. These results were regarded as satifactory for both methods intended for rapid analysis of materials for which decomposition is difficult and time-consuming. Also described are some results from an interlaboratory comparison used to certify one of the materials that had been previously used for validation in both interlaboratory comparisons. Thirty laboratories (from eight countries) participated in this interlaboratory comparison for certification. As examples, accepted results are shown from laboratories that used ETV ICP OES or DC arc OES and had performed calibrations by using solutions or oxides, respectively. The certified mass fractions of the certified reference materials were also compared with the mass fractions determined in the interlaboratory comparisons performed within the framework of method standardization. Good agreement was found for most of the analytes. KW - Inductively coupled plasma optical emission spectrometry KW - Electrothermal vaporization KW - ETV ICP OES KW - Direct current optical emission spectrometry KW - DC arc OES KW - Direct solid sampling technique KW - Silicon carbide powder KW - Method validation KW - Method standardization KW - Direkte Feststoffanalytik KW - Normung KW - Methodenvalidierung KW - Ringversuche KW - Siliciumcarbid PY - 2005 DO - https://doi.org/10.1007/s00216-005-3415-x SN - 1618-2642 SN - 1618-2650 VL - 383 IS - 7-8 SP - 1060 EP - 1074 PB - Springer CY - Berlin AN - OPUS4-10890 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Traub, Heike A1 - Czerwensky, Michael A1 - Matschat, Ralf A1 - Kipphardt, Heinrich A1 - Panne, Ulrich T1 - Homogenitätsprüfung und Analyse von reinem Kupfer mit Laserablation-ICP-Massenspektrometrie JF - Metall KW - Laserablation KW - Kupfer KW - Homogenität KW - ZRM PY - 2007 SN - 0026-0746 VL - 61 IS - 11 SP - 744 EP - 745 PB - Giesel Verlag GmbH CY - Isernhagen AN - OPUS4-16153 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wienold, Julia A1 - Traub, Heike A1 - Lange, Britta A1 - Giray, Thorsten A1 - Recknagel, Sebastian A1 - Kipphardt, Heinrich A1 - Matschat, Ralf A1 - Panne, Ulrich T1 - Elemental analysis of copper and magnesium alloy samples using IR-laser ablation in comparison with spark and glow discharge methods JF - Journal of analytical atomic spectrometry N2 - Three methods for direct solid sampling of bulk material namely IR laser ablation, glow discharge and spark OES, were compared with respect to analytical figures of merit obtained for elemental analysis with atomic spectrometry. Matrices investigated were copper, pressed doped copper powder, and magnesium alloys. For the vast majority of analytes, statistical equivalence regarding precision (usually ≤ 5%) and the performance of the calibrations between the compared methods was demonstrated. KW - LA-ICP-MS KW - GD-MS KW - Spark-OES KW - LA-ICP-OES KW - Copper KW - Magnesium PY - 2009 DO - https://doi.org/10.1039/b903251g SN - 0267-9477 SN - 1364-5544 VL - 24 SP - 1570 EP - 1574 PB - Royal Society of Chemistry CY - London AN - OPUS4-20257 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Traub, Heike A1 - Wälle, M. A1 - Koch, J. A1 - Panne, Ulrich A1 - Matschat, Ralf A1 - Kipphardt, Heinrich A1 - Günther, D. T1 - Evaluation of different calibration strategies for the analysis of pure copper and zinc samples using femtosecond laser ablation ICP-MS JF - Analytical and bioanalytical chemistry N2 - Solution-doped metal powder pellets as well as aspirated liquids were used as calibration samples to analyze pure copper and zinc certified reference materials (CRMs) by femtosecond laser ablation ICP-MS. It was demonstrated that calibration by copper pellets resulted in relative deviations up to 20%, whereas fs-LA-ICP-MS among copper-based CRMs led to inaccuracies in the same range unless nominal mass fractions were chosen to be <3 mg/kg. Calibration by zinc pellets generally provided better accuracy. Depending on the analyte considered, deviations below 10% were obtained even for mass fractions close to the limit of quantification. Our data, therefore, indicate solution-doped metal powder pellets to be suitable as calibration samples for fs-LA-ICP-MS of metals. Furthermore, the utilization of liquid standards for calibration was found to result in stronger deviations of up to 50% for both copper and zinc samples which, in addition, turned out to be dependent on the plasma conditions. KW - Laser ablation KW - ICP-MS KW - Calibration KW - Copper KW - Zinc KW - Metal PY - 2009 DO - https://doi.org/10.1007/s00216-009-3061-9 SN - 1618-2642 SN - 1618-2650 VL - 395 IS - 5 SP - 1471 EP - 1480 PB - Springer CY - Berlin AN - OPUS4-20402 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Traub, Heike A1 - Czerwensky, Michael A1 - Matschat, Ralf A1 - Kipphardt, Heinrich A1 - Panne, Ulrich T1 - Different calibration strategies for the analysis of pure copper metal by nanosecond laser ablation inductively coupled plasma mass spectrometry JF - Journal of analytical atomic spectrometry N2 - In this work, different calibration strategies for the determination of trace elements in pure copper metal by nanosecond laser ablation ICP-MS were investigated. In addition to certified reference materials (CRMs), pellets of doped copper powder were used for calibration. The micro homogeneity of the CRMs as well as the solution-doped pellets was sufficient to use them as calibration samples in combination with a laser spot size of 200 µm. In contrast, pellets doped with analytes in solid form showed a significant heterogeneity. For most of the investigated analytes and copper CRMs the measured mass fractions were within ± 20% of their certified values when other copper CRMs were used as calibration samples. When solution-doped powder pellets were used as calibration samples a systematic trend towards mass fractions below the certified values was observed for nearly all elements determined in the analysed CRMs. Thermal fractionation effects during the ablation of the solution-doped pellets were suspected as the extent of the fractionation depends on the irradiance, whereas fractionation is reduced at higher irradiance. PY - 2010 DO - https://doi.org/10.1039/b915564c SN - 0267-9477 SN - 1364-5544 VL - 25 IS - 5 SP - 690 EP - 696 PB - Royal Society of Chemistry CY - London AN - OPUS4-21195 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -