TY - JOUR A1 - Höpken, C. A1 - Swart, Claudia A1 - Traub, Heike T1 - A fragment of a dichroic cage cup from Dülük Baba Tepesi/Doliche, Turkey KW - Diatretglas KW - LA-ICP-MS PY - 2008 SN - 0075-4250 VL - 50 SP - 303 EP - 306 CY - Corning, NY AN - OPUS4-18442 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Phukphatthanachai, Pranee A1 - Vogl, Jochen A1 - Traub, Heike A1 - Jakubowski, Norbert A1 - Panne, Ulrich T1 - A new approach of using polyethylene frits for the quantification of sulphur in copper metals by isotope dilution LA-ICP-MS and comparison with conventional IDMS techniques N2 - Polyethylene (PE) frits were used to quantify sulphur in copper and its alloys by isotope dilution combined with LA-ICP-MS as an alternative approach to conventional sample preparation: the copper samples were spiked, the spiked samples were dissolved, the resulting solutions were absorbed in the PE frits and finally the PE frits were analysed by LA-ICP-MS. A prerequisite for such a support material is a low sulphur blank and thus PE was selected for this purpose. The absorption efficiency of the PE frits was studied for varying sulphur amounts ranging from 2 mg S to 80 mg S showing that more than 99.5% of the loaded sulphur was absorbed by the frit. The so prepared PE frits were measured by LA-ICP-MS and yielded a good linearity (R2 ¼ 0.999) for the sulphur ion intensities corresponding to sulphur amounts up to 40 mg S; the associated sensitivity is approximately 3.4 x 10⁴ cps μg⁻¹ for ³²S. For the validation of the developed procedure the reference materials BAM-M376a, BAM-228 and BAM-227 were applied such that 2 μg S, 5 μg S and 11 μg S were absorbed in the PE frits, respectively. These samples were pre-quantified for the adsorbed sulphur amount by external calibration LA-ICP-MS yielding sulphur amounts of 0.9 μg, 5.1 μg and 8.5 μg (quantified for ³²S only), respectively. Relative Standard deviations of the isotope ratios were below 5% in average (n ¼ 3 lines) in all cases (except for the pure spike solution). These samples were then analysed by LA-ICP-IDMS and the measurement results were validated by comparing them with the results obtained by conventional ICP-IDMS. The obtained relative expanded measurement uncertainties ranged between 10% and 26%. Pearson's coefficient was used to express the correlation between both techniques; the obtained value was 0.999 demonstrating a strong correlation. Contrary to most published LA-ICP-IDMS procedures, the developed procedure enables SI-traceability for the measurement results. The metrological traceability to the SI for the sulphur mass fractions in copper was established by an unbroken chain of comparisons, each accompanied by an uncertainty budget. Thus, the measurement results are considered reliable, acceptable and comparable within the stated measurement uncertainty. The metrological traceability chain from the kg down to mass fraction in the samples obtained by LA-ICP-IDMS is presented as well. KW - Laser ablation KW - IDMS KW - Traceability KW - Uncertainty KW - Purity PY - 2018 DO - https://doi.org/10.1039/c8ja00116b SN - 0267-9477 SN - 1364-5544 VL - 33 IS - 9 SP - 1506 EP - 1517 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-45899 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Scharek, Vera M. A1 - Kröger, Tommy A1 - Keil, Karin A1 - Traub, Heike A1 - Meermann, Björn T1 - A new elemental analytical approach for microplastic sum parameter analysis—ETV/ICP-MS with CO2 N2 - Microplastics (MPs) are pervasive environmental pollutants and are considered one of the main challenges of our time. However, a fast and comprehensive analytical approach for MP analysis in complex matrices traceable to SI units is still lacking. In this context, we report a fast screening tool for the sum parameter analysis of MPs using electrothermal vaporization (ETV) coupled to inductively coupled plasma-mass spectrometry (ICP-MS). In our proof-of-concept study, we observed size-independent detection of MPs as peaks above the 13C+ signal background in the nano- to micrometer range without limitations regarding the polymer type. Quantification of the 13C+ MP signals was accomplished via an external gas calibration utilizing dynamic dilution of carbon dioxide with argon, yielding recovery rates of 80–96% for MP reference material (RM) of polymer types commonly found in the environment. The applicability to a soil sample was demonstrated through spiking experiments with a polyethylene (PE) MP RM in soil. The limit of detection (LOD) was estimated to be 0.13 µg C, equaling the detection of a single spherical low-density-PE particle of about 70 µm, and a limit of quantification (LOQ) of 0.42 µg C. KW - ETV/ICP-MS KW - Mikroplastik KW - Summenparameter PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-646418 DO - https://doi.org/10.1007/s00216-025-06146-x SN - 1618-2642 SP - 1 EP - 10 PB - Springer CY - Berlin ; Heidelberg AN - OPUS4-64641 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kaufmann, Jan Ole A1 - Brangsch, J. A1 - Kader, A. A1 - Saatz, Jessica A1 - Mangarova, D. B. A1 - Zacharias, M. A1 - Kempf, W. E. A1 - Schwaar, T. A1 - Ponader, Marco A1 - Adams, L. C. A1 - Möckel, J. A1 - Botnar, R. M. A1 - Taupitz, M. A1 - Mägdefessel, L. A1 - Traub, Heike A1 - Hamm, B. A1 - Weller, Michael G. A1 - Makowski, M. R. T1 - ADAMTS4-specific MR-probe to assess aortic aneurysms in vivo using synthetic peptide libraries N2 - The incidence of abdominal aortic aneurysms (AAAs) has substantially increased during the last 20 years and their rupture remains the third most common cause of sudden death in the cardiovascular field after myocardial infarction and stroke. The only established clinical parameter to assess AAAs is based on the aneurysm size. Novel biomarkers are needed to improve the assessment of the risk of rupture. ADAMTS4 (A Disintegrin And Metalloproteinase with ThromboSpondin motifs 4) is a strongly upregulated proteoglycan cleaving enzyme in the unstable course of AAAs. In the screening of a one-bead-one-compound library against ADAMTS4, a low-molecular-weight cyclic peptide is discovered with favorable properties for in vivo molecular magnetic resonance imaging applications. After identification and characterization, it’s potential is evaluated in an AAA mouse model. The ADAMTS4-specific probe enables the in vivo imaging-based prediction of aneurysm expansion and rupture. KW - Peptide KW - Peptide library KW - OBOC library KW - Combinatorial chemistry KW - Peptide aptamers KW - Binding molecule KW - Affinity KW - Synthetic peptides KW - Contrast agent KW - Magnetic resonance imaging KW - One-bead-one-compound library KW - On-chip screening KW - Lab-on-a-chip KW - MALDI-TOF MS KW - SPR KW - Surface plasmon resonance KW - Alanine scan KW - Fluorescence label KW - MST KW - Docking KW - Chelate PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-560930 DO - https://doi.org/10.1038/s41467-022-30464-8 N1 - Geburtsname von Ponader, Marco: Wilke, M. - Birth name of Ponader, Marco: Wilke, M. VL - 13 IS - 1 SP - 1 EP - 18 PB - Springer Nature Limited CY - Heidelberg AN - OPUS4-56093 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schannor, Mathias A1 - Oelze, Marcus A1 - Traub, Heike A1 - He, Yubei A1 - Schmidt, Robin A1 - Heidemann, Luisa A1 - Savic, Lynn Jeanette A1 - Vogl, Jochen A1 - Meermann, Björn T1 - Advancing Biomarker Research: In Situ Cu Isotope Analysis in Liver Tumors by LA-MC-ICP-MS N2 - Stable metal isotopes have received increasing attention as medical biomarkers due to their potential to detect changes in metal metabolism related to diseases. In particular, copper stable isotopes are a powerful tool to identify isotopic variation between tumors and healthy tissue, suggesting application in cancer diagnosis. However, potential mechanisms causing isotope fractionation, such as redox- or bond-forming reactions and interactions of metals during transmembrane import and export, are less well understood. Here, we established an in situ method using laser ablation-multicollector-inductively coupled plasma-mass spectrometry (LA-MC-ICP-MS) to advance our understanding of the underlying processes responsible for isotope fractionation between normal and diseased tissues. Gelatin-based bracketing standards and quality control reference materials, crucial for laser ablation analysis, were developed to allow correction for instrumentally induced isotope fractionation during LA-MC-ICP-MS analysis. Using such matrix-matched standards, the method achieved intermediate precisions for delta values of better than 0.15 ‰ (2 s) for inorganic reference materials and of better than 0.17 ‰ (2 s) for biological reference materials. The developed routine was tested on rabbit VX2 liver tumor samples, a model system resembling human hepatocellular carcinoma (HCC) used to study liver cancer. In situ Cu isotope compositions between healthy (𝛿65/63NIST976(Cu) = −1.5 ‰ to 0.2 ‰) and tumorous (𝛿65/63NIST976(Cu) = 0.0 ‰ to 1.3 ‰) liver tissue show distinct differences in their isotope ratios. The observed isotopic dichotomy is consistent with previous solution-based MC-ICP-MS work, showing enrichment of heavy 65Cu in cancer biopsies relative to healthy tissue. KW - Biomarker KW - Laser Ablation KW - Reference Material PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-626865 DO - https://doi.org/10.1021/acs.analchem.4c05626 SN - 1520-6882 VL - 97 IS - 8 SP - 4425 EP - 4432 PB - American Chemical Society (ACS) AN - OPUS4-62686 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Analyse von Hochtechnologiematerialien mit ETV und Bogen T2 - Solid-Samping-User-Meeting CY - Kempten, Germany DA - 2004-05-24 PY - 2004 AN - OPUS4-3571 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Analyse von reinem Kupfer mit LA-ICP-MS: Möglichkeiten der Kalibrierung mit synthetischen Standards T2 - CANAS '07, Colloquium Analytische Atomspektroskopie CY - Konstanz, Germany DA - 2007-03-18 PY - 2007 AN - OPUS4-14627 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Analyse von Reinkupfer mit LA-ICP-MS: Vergleich unterschiedlicher Kalibrierstrategien T2 - ANAKON 2009 CY - Berlin, Germany DA - 2009-03-17 PY - 2009 AN - OPUS4-19009 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Shigeta, K. A1 - Traub, Heike A1 - Panne, Ulrich A1 - Okino, A. A1 - Rottmann, L. A1 - Jakubowski, Norbert T1 - Application of a micro-droplet generator for an ICP-sector field mass spectrometer - optimization and analytical characterization N2 - A micro-droplet generator (µDG) sample introduction system was coupled to a sector field ICP-MS instrument to investigate the analytical figures of merit with respect to single cell analysis. The sector field instrument was operated for the first time in a fast scanning mode (E-scan) with the shortest time resolution of 100 µs to measure the single droplet time resolved and using the original detector in a pulse counting mode without modification of the existing electronics. For reduction of the droplet diameter a triple pulse mode of the droplet generator was applied and a droplet diameter down to 23 µm has been achieved for this investigation with a 100% transport efficiency of droplets. Signal duration times of single droplets of less than 500 µs have been measured. Overall detection efficiencies in the range of 10-3 counts per atom have been achieved and absolute limits of detection range between 120 ag for Fe and 1.1 ag for Mg as a mean value from 1000 droplet events. PY - 2013 DO - https://doi.org/10.1039/c2ja30207a SN - 0267-9477 SN - 1364-5544 VL - 28 IS - 5 SP - 646 EP - 656 PB - Royal Society of Chemistry CY - London AN - OPUS4-29447 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Traub, Heike T1 - Application of different calibration strategies for the analysis of pure copper using nano- and femtosecond laser ablation ICP-MS T2 - European Winter Conference on Plasma Spectrochemistry CY - Graz, Austria DA - 2009-02-15 PY - 2009 AN - OPUS4-19007 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -