TY - GEN A1 - Smales, Glen Jacob A1 - Pauw, Brian Richard T1 - Technical Drawings for The MOUSE Modular Sample Holder: Capillary Flow-through Cell N2 - OpenSCAD, STL and technical drawings for the capillary flow-through cell designed primarily for use with The MOUSE instruments. This flow-through cell can be used in conjunction with: - Modular sample holder (10.5281/zenodo.7499416) - Solid sample rack/plate (10.5281/zenodo.7499424) - Laser-cut sample holder (10.5281/zenodo.7499437) KW - X-ray scattering KW - SAXS KW - Sample holder KW - MOUSE PY - 2023 U6 - https://doi.org/10.5281/zenodo.7499421 PB - Zenodo CY - Geneva AN - OPUS4-56776 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Pauw, Brian Richard A1 - Röder, Bettina A1 - Smales, Glen Jacob T1 - High temperature in-vacuum flow-through sample holder (sandwich design version 1.1) N2 - Technical drawings and documents for building a compact, heated, vacuum compatible flow-through sample holder. This holder is in use at the BAM MOUSE instrument as well as at the I22 beamline at the Diamond Light Source (see references for instrument details). This holder has several features: - The holder can be used in vacuum environments as well as in atmosphere - It has two G 1/4" UNF fittings to attach HPLC tubing for (optionally) flowing a medium through the sample cell - There are two additional (unflowed) sample positions for backgrounds and calibrants, held at the same temperature - The low-mass design coupled with a 250W heating element can achieve heating rates of 1 degree C per second, when coupled (for example) with an Omron E5CC PID controller. - The sample holder insert can be made from various materials depending on the application. Sealing the sample from the vacuum can be achieved using kapton, teflon or Magic tape, depending on the temperature requirements. The inlet and outlet holes will need to be punctured with a needle to enable flow. - Large exit cones ensure a clear exit angle of at least 45 degrees two theta. - It has been tested with temperatures up to 400 degrees C. - Compression area has been raised and polished to ensure a good vacuum seal. KW - SAXS KW - X-ray scattering KW - Sample cell KW - Sample holder KW - Heated KW - Flow-through KW - Vacuum compatible KW - XRD KW - WAXS PY - 2023 U6 - https://doi.org/10.5281/zenodo.7501030 PB - Zenodo CY - Geneva AN - OPUS4-56777 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Smales, Glen Jacob A1 - Pauw, Brian Richard T1 - Technical Drawings for The MOUSE Modular Sample Holder: Solid Sample Rack/Plate N2 - OpenSCAD, STL and technical drawings for the solid sample rack designed primarily for use with The MOUSE instruments. This solid sample rack can be used in conjunction with: - Laser-cut sample holder (10.5281/zenodo.7499437) - Modular sample holder (10.5281/zenodo.7499416) - Capillary flow-cell for liquid samples (10.5281/zenodo.7499421) KW - X-ray scattering KW - SAXS KW - Sample holder KW - MOUSE PY - 2023 U6 - https://doi.org/10.5281/zenodo.7499424 PB - Zenodo CY - Geneva AN - OPUS4-56778 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Smales, Glen Jacob A1 - Pauw, Brian Richard T1 - Technical Drawings for The MOUSE Modular Sample Holder: Laser-cut Sample Holder N2 - PDF file for the laser-cut sample holder designed primarily for use with The MOUSE instruments. This sample holder can be used in conjunction with: - Solid sample rack/plate (10.5281/zenodo.7499424) - Modular sample holder (10.5281/zenodo.7499416) - Capillary flow-cell for liquid samples (10.5281/zenodo.7499421) KW - X-ray scattering KW - SAXS KW - Sample holder KW - MOUSE PY - 2023 U6 - https://doi.org/10.5281/zenodo.7499437 PB - Zenodo CY - Geneva AN - OPUS4-56779 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Smales, Glen Jacob A1 - Pauw, Brian Richard T1 - Technical Drawings for The MOUSE Modular Sample Holder N2 - OpenSCAD, STL and technical drawings for the Modular sample holder designed primarily for use with The MOUSE instruments. This modular sample holder can be used in conjunction with the following: - Capillary flow-cell for liquid samples (10.5281/zenodo.7499421) - Solid sample rack/plate (10.5281/zenodo.7499424) - Laser-cut sample holder (10.5281/zenodo.7499437) KW - X-ray scattering KW - SAXS KW - Sample holder KW - MOUSE PY - 2023 U6 - https://doi.org/10.5281/zenodo.7499416 PB - Zenodo CY - Geneva AN - OPUS4-56775 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -