TY - CONF A1 - Seeger, Stefan A1 - Pollakowski-Herrmann, Beatrix A1 - Osan, J. A1 - Gross, A. A1 - Stosnach, H. A1 - Kayser, Y. A1 - Beckhoff, B. T1 - Quantification of element mass concentrations in aerosols by combination of cascade impactor sampling and in-situ TXRF Spectroscopy N2 - A mobile Bruker S2 Picofox TXRF spectrometer has been used in two field campaigns within the EMPIR env07 AEROMET project for the on-site analysis of cascade impactor aerosol samples.The results show that even at moderate air pollution levels – i.e.PM10 fairly below 20 μg/m³ - element mass concentrations in air in the range of 100 pg/m³could be measured in up to 13 size bins after sampling times of less than only 0.5 days. T2 - UFP 2019 Ultrafeinstaub in der Atmosphäre und in Innenräumen, 3. Symposium CY - Technische Universität Berlin, Germany DA - 19.09.2019 KW - TXRF ambient air aerosol chemical analysis aerosol element composition KW - Aerosol KW - TXRF KW - Cascade impactor KW - Aerosol element alanysis KW - Aerosol element mass concentration PY - 2019 AN - OPUS4-49580 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kayser, Y. A1 - Gross, A. A1 - Hönicke, P. A1 - Osan, J. A1 - Pollakowski-Herrmann, B. A1 - Seeger, Stefan A1 - Beckhoff, B. T1 - Reliable chemical analysis of aerosols by reference-free X-ray spectrometry for monitoring airborne particulate matter N2 - The physical and chemical analysis of aerosols using reliable and physically traceable methods is important for the thorough investigation of airborne particles to support a better understanding of their origin as well as their health and climate impacts. Within the European Metrology Research AeroMet project,the aim of hysikalisch–Technische Bundesanstalt’s (PTB) X-ray spectrometry group is to develop and establish traceable and reliable X-ray methods to measure the elemental mass deposition per unit area, the elemental composition,and the chemical binding state of particulate matter supported by a flat substrate. This approach can substantially contribute to support quantitative analytical methods during on-site measurement campaigns where portable Instrumentation is employed by qualifying suitable calibration samples for commercial analytical X-ray instruments and by investigating samples collected during the field campaign. KW - AEROMET project KW - X-Ray analysis KW - TXRF KW - Aerosols KW - Particles KW - Air pollution KW - Elemental composition PY - 2020 UR - https://www.spectroscopyonline.com/view/reliable-chemical-analysis-of-aerosols-by-reference-free-x-ray-spectrometry-for-monitoring-airborne-particulate-matter SN - 0887-6703 VL - 35 IS - 10 SP - 42 EP - 46 PB - MJH Life Sciences CY - Cranbury, NJ AN - OPUS4-53357 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Seeger, Stefan A1 - Brödner, Doris A1 - Jacobi, T. A1 - Rasch, Fabian A1 - Rothhardt, Monika A1 - Wilke, Olaf T1 - Emissions of fine and ultrafine particles and volatile organic compounds from different filament materials operated on a low-cost 3D printer T1 - Emissionen feiner und ultrafeiner Partikel sowie flüchtiger organischer Verbindungen beim Einsatz verschiedener Filamentmaterialien in einem „low-cost“-3D-Drucker N2 - 3D-printing or additive manufacturing has many promising and unique advantages. Especially low cost molten polymer Deposition Printers are increasingly populär in the private and educational sector. Their environmental friendliness can be questioned due to recently reported ultrafine particle and suspected VOC emissions, To further investigate 3D-printing as a potential indoor air pollution source we characterized fine and ultrafine particle emissions from a molten polymer deposition printer producing a 3D object with ten marketable polymer filament materials under controlled conditions in a test chamber. VOC emissions from the filaments have also been compared. Using a straightforward emission model time dependent and averaged particle emission rates were determined. The results indicate that under comparable conditions some filament materials produce mainly ultrafine particles up to an average rate of 1013 per minute. This value is in the upper ränge of typical indoor ultrafine particle sources (e.g. Smoking, frying, candle light, laser printer). The observed material-specific rates differ by five Orders of magnitude. Filament-specific gaseous emissions of organic compounds such as bisphenol A, styrene and others were also detected. Our results suggest a detailed evaluation of related risks and considering protective measures such as housing and filtering. N2 - 3D-Druck oder additive Herstellungsverfahren haben eine Menge vielversprechender und einzigartiger Vorteile. Insbesondere günstige 3D-Drucker für Polymere werden im privaten und ausbildenden Bereich zunehmend beliebter. Ihre Umweltfreundlichkeit kann aufgrund jüngst berichteter Emissionen ultrafeiner Partikel und vermuteter VOC-Emissionen infrage gestellt werden. Um 3D-Drucker für Polymere als mögliche Quelle von Innenraumluftverunreinigungen weiter zu untersuchen, charakterisierten wir die Emissionen feiner und ultrafeiner Partikel bei der Herstellung eines 3D-Objekts unter Verwendung zehn marktgängiger Polymerfilamente unter kontrollierten Bedingungen in einer Emissionsprüfkammer. Die VOC-Emissionen der verschiedenen Filamente wurden ebenfalls verglichen. Die zeitabhängigen und gemittelten Partikelemissionsraten wurden durch Anwendung eines einfachen Emissionsmodells bestimmt. Die Ergebnisse zeigen, dass unter vergleichbaren Bedingungen einige Filamente mit einer mittleren Rate von 10 KW - Emission KW - Ultrafine particles KW - VOC KW - 3D printer PY - 2018 SN - 0949-8036 SN - 0039-0771 VL - 78 IS - 3 SP - 79 EP - 87 PB - Springer-VDI-Verl. CY - Düsseldorf AN - OPUS4-44954 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seeger, Stefan T1 - VOC, Fine and Ultrafine Particles Emissions from Additive Manufacturing and 3D-Printers N2 - The presentation gives an overview on Additive Manufacturing techniques and related potential risks from emission of hazardous gases and aerosols, based on emission characterizations in BAM. Voluntary mitigation strategies are presented T2 - BAM - JBMIA (Japan Business Machine and Information System Industries Association) Meeting, JBMIA Emissions Working Group Meeting CY - Tokyo, Japan DA - 04.05.2019 KW - 3D Printing KW - Additive Manufacturing KW - Particulate emissions KW - Emissions of hazardous gases KW - Filament comparison PY - 2019 AN - OPUS4-47812 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seeger, Stefan T1 - UBA Projects on Particulate Emissions from Laser Printers N2 - The presentation gives an overview on past and ongoing projects in BAM on laser printer particulate emissions, funded by the German Environment Agency (UBA) in order to further develop award criteria for the Blue Angel ecolabel for office machines T2 - BAM - JBMIA (Japan Business Machine and Information System Industries Association) Meeting, JBMIA Emissions Working Group Meeting CY - Tokyo, Japan DA - 04.05.2019 KW - Laser Printer KW - Particulate emission KW - Blue Angel ecolabel KW - Office machines PY - 2019 AN - OPUS4-47811 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jörres, R. A1 - Ehret, M. A1 - Karrasch, S. A1 - Herbig, B A1 - Schierl, R. A1 - Seeger, Stefan A1 - Langner, J. A1 - Nowak, D. T1 - Respiratorische Effekte von Drucker- und Kopierer-Emissionen – eine kontrollierte Expositionsstudie N2 - Die möglichen gesundheitlichen Auswirkungen von Laserdruckeremissionen sind immer wieder Gegenstand von Aufmerksamkeit. Wir untersuchten die Effekte 75-minütigerExpositionen gegenüber Low-Emittern (LE, Untergrund 2000 – 4000 UFP/cm3) und High-Emittern (HE, 100.000 UFP/cm3). T2 - 56. Kongress der Deutschen Gesellschaft für Pneumologie und Beatmungsmedizin e.V. CY - Berlin, Germany DA - 18.03.2015 KW - Expositionsstudie in-vivo KW - Bürogeräte KW - Emissionen KW - Partikel PY - 2015 DO - https://doi.org/10.1055/s-0035-1544873 VL - 69-V516 SP - V516 PB - Thieme CY - Stuttgart AN - OPUS4-38752 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -