TY - JOUR A1 - Zhang, K. A1 - Mezhov, Alexander A1 - Schmidt, Wolfram T1 - Chemical and thixotropic contribution to the structural build-up of cementitious materials JF - Construction and Building Materials N2 - The structural build-up of fresh cement paste is often considered as a purely thixotropic phenomenon in literature even though cementitious materials undergo a non-reversible hydration process that can have an influence on the structuration process. In the current paper a method is proposed to validate the impact of the non-reversible structural build-up. It is shown that fresh cement paste samples lose their structural gain almost completely due to thixotropy while the structural build-up due to hydration can be observed but occurs in a significantly lower order of magnitude over the course of the first hours of hydration. In addition, it is shown, that the chemical component of the structural build-up accelerates with the onset of the acceleration period of hydration, while its contribution in the entire structural build-up remains constant. KW - Thixotropy KW - Structural build-up KW - Penetration test KW - Rheological properties PY - 2022 DO - https://doi.org/10.1016/j.conbuildmat.2022.128307 SN - 0950-0618 VL - 345 IS - 128307 SP - 1 EP - 10 PB - Elsevier Ltd. AN - OPUS4-58248 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zhang, K. A1 - Mezhov, Alexander A1 - Schmidt, Wolfram T1 - Thixotropic and chemical structural build-up of cement pastes with superplasticizer under different storage conditions T2 - International Concrete Abstracts Portal N2 - Synopsis: The paper presents the results of a study on the influence of agitation on the structural build-up of fresh cement pastes using a penetration test. It first presents results about the influence of the penetrating shape’s geometry on the influence on the cement paste specimen. Then, results are shown for the load-deflection curves depending upon time and agitation before testing. Based on the observation of the force required to penetrate the sample, conclusions on the structural build-up can be made. The observations were made over the course of time with samples that were left at rest and partly agitated before testing at different time steps. The setup allows to identify the contribution of the chemical reaction to the structural build-up process. The presence of superplasticizer obviously reduces the load that cement paste can withstand, while the loss of thixotropy is found notably lower than that of neat cement pates T2 - 13th International Conference on Superplasticizers and Other Chemical Admixtures in Concrete CY - Milan, Italy DA - 10.07.2022 KW - Thixotropy KW - Superplasticizer KW - Structural build-up KW - Texture analyzer KW - Penetration test PY - 2022 DO - https://doi.org/10.14359/51736058 VL - 354 SP - 13 EP - 24 PB - ACI Special Publications AN - OPUS4-58324 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -