TY - JOUR A1 - Schiel, D. A1 - Rienitz, O. A1 - Jährling, R. A1 - Güttler, B. A1 - Matschat, Ralf A1 - Scharf, Holger A1 - Birkhahn, Jürgen A1 - Labarraque, G. A1 - Fisicaro, P. A1 - Borchers, U. A1 - Schwesig, D. T1 - Metrological concept for comparable measurement results under the European water framework directive: demonstration of its applicability in elemental analysis N2 - Within the scope of a project of the 'European Association of National Metrology Institutes' (EURAMET), a European metrological dissemination System (network) providing traceable reference values assigned to matrix materials for validation purposes is described and put to the test. It enables testing laboratories (TL) to obtain comparable results for measurements under the 'EU Water Framework Directive 2000/60/EC' (WFD) and thus, to comply with a core requirement of this very directive. The dissemination system is characterized by the fact that it is available to all laboratories throughout Europe which intend to perform measurements in the context of the WFD and that it can ensure sustainable metrological traceability to the International System of Units (SI) as a reference point for the measurement results. This Dissemination system is set up in a hierarchical manner and links up the level of the national metrology institutes (NMI) with that of the TLs via an intermediate level of calibration laboratories (CL) by comparison measurements. The CLs are expert laboratories with respect to the measurement of the analytes considered here (within the project, the CLs are called potential calibration laboratories (PCL)) and are additionally involved in the organization of comparison measurements within the scope of regional quality assurance (QA) systems. Three comparison measurements have been performed to support the approach. A total of about 130 laboratories participated in this exercise with the focus on the measurement of the priority substances Pb, Cd, Hg, and Ni defined in the WFD. The elemental concentrations in the water samples roughly corresponded to one of the established environmental quality standards (EQS), the annual average concentration (AA-EQS), which is defined in the daughter Directive 2008/105/EC of the WFD. It turned out that a significant number of TLs still need to improve their measurement methods in order to be able to fulfill the Minimum requirements of the WFD, in particular, with regard to the elements Cd and Hg probably due to their low EQS values. Furthermore, it became obvious that the hierarchical Dissemination system suggested here actually corresponds to the measuring capabilities of the three participating Groups (NMIs, PCLs, and TLs). KW - Metrology KW - Metrological traceability KW - Comparability KW - Elemental analysis KW - Water framework directive PY - 2011 U6 - https://doi.org/10.1007/s00769-011-0792-z SN - 0949-1775 SN - 1432-0517 VL - 16 IS - 10 SP - 489 EP - 498 PB - Springer CY - Berlin AN - OPUS4-24485 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tirez, K. A1 - Scharf, Holger A1 - Calzolari, D. A1 - Cleven, R. A1 - Kisser, M. A1 - Lück, Detlef T1 - Validation of a European standard for the determination of hexavalent chromium in solid material N2 - A European standard for the determination of Cr(VI) in solid material has been elaborated in the framework of an international co-operation and finally validated in the course of an interlaboratory comparison. The procedure is based on the alkaline digestion prescribed by EPA method 3060A followed by ion chromatography and determines an operationally defined content of Cr(VI), including water-soluble and insoluble chromates. A preliminary robustness study was carried out in order to compare different extraction methodologies and to study the equivalency of different analytical methods for the determination of Cr(VI) in alkaline extracts of soil and waste materials. During an interlaboratory validation trial with 19 European laboratories a set of 4 samples (2 soil and 2 waste samples) was analysed to determine performance characteristics for different combinations of digestion and detection methods. With the procedures prescribed by the new European standard (EN 15192) acceptable results were obtained for both soil samples and one of the waste samples (sludge). However, for the second waste sample (fly ash) a large deviation in analytical results was observed. This indicates that particularly for waste materials a possible occurrence of strong matrix effects has to be considered and supplementary quality control data are needed in order to assess the validity of analytical results. The accuracy of the determination of Cr(VI) in solid matrices remains a challenging field in terms of maximum extraction efficiency and minimum species interconversion. KW - Umweltanalytik KW - Chrom(VI) KW - Boden KW - Abfall KW - Validierung KW - Europäische Norm PY - 2007 SN - 1464-0325 SN - 1464-0333 VL - 9 IS - 7 SP - 749 EP - 759 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-15043 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Scharf, Holger A1 - Becker, Roland A1 - Bremser, Wolfram A1 - Buge, Hans-Gerhard A1 - Lück, Detlef T1 - Certification of the mass fractions of trace elements and pentachlorophenol in an impregnated wood reference material N2 - The resource-saving utilisation of recovered waste wood is a matter of growing concern. In several European countries, this utilisation is governed by regulations and is dependent on the contents of certain trace elements and organic compounds. Thus, for decisionmaking with respect to waste wood management (recycling or combustion), reliable analytical data are needed and, due to their great economic and environmental impact, must be assured by appropriate quality control. To support the improvement in quality assurance in waste wood analysis, for the first time, a wood reference material was certified for its mass fractions of arsenic, cadmium, chromium, copper, lead, mercury, and pentachlorophenol (PCP). These analytes were selected because they represent typical constituents of wood preservatives most widely used in the past. Material preparation and testing of homogeneity and stability were carried out by BAM Federal Institute for Materials Research and Testing. The certification measurements were performed involving selected laboratories with documented expertise in the field of waste wood analysis. The certified values and their corresponding uncertainties were assigned in full compliance with the requirements of ISO Guide 35. The certified mass fractions and their expanded uncertainties (k/i> = 2) are as follows: (3.1 ± 0.5) mg/kg for As, (3.02 ± 0.24) mg/kg for Cd, (36.4 ± 2.6) mg/kg for Cr, (22.9 ± 1.7) mg/kg for Cu, (0.60 ± 0.14) mg/kg for Hg, (39 ± 4) mg/kg for Pb, and (7.9 ± 0.6) mg/kg for PCP. The certified material is available as European Reference Material ERM®-CD100. KW - Waste wood KW - Trace elements KW - Pentachlorophenol KW - Certification KW - European reference material PY - 2010 U6 - https://doi.org/10.1007/s00769-010-0699-0 SN - 0949-1775 SN - 1432-0517 VL - 15 IS - 11 SP - 613 EP - 619 PB - Springer CY - Berlin AN - OPUS4-22392 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Chinthalapati, Siva Kesava Raju A1 - Cossmer, Antje A1 - Scharf, Holger A1 - Panne, Ulrich A1 - Lück, Detlef T1 - Speciation of gadolinium based MRI contrast agents in environmental water samples using hydrophilic interaction chromatography hyphenated with inductively coupled plasma mass spectrometry KW - HPLC-ICP-MS KW - HILIC chromatography KW - Speciation KW - Gadolinium KW - MRI contrast agent PY - 2010 U6 - https://doi.org/10.1039/b919959d SN - 0267-9477 SN - 1364-5544 VL - 25 SP - 55 EP - 61 PB - Royal Society of Chemistry CY - London AN - OPUS4-20705 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Chinthalapati, Siva Kesava Raju A1 - Lück, Detlef A1 - Scharf, Holger A1 - Jakubowski, Norbert A1 - Panne, Ulrich T1 - A novel solid phase extraction method for pre-concentration of gadolinium and gadolinium based MRI contrast agents from the environment N2 - An efficient solid phase extraction (SPE) method using bis-(2-ethylhexyl)-phosphate (HDEHP) coated reverse phase C18 support has been developed for the pre-concentration of Gadolinium (Gd) and Gd contrast agents widely used in magnetic resonance imaging (MRI). Enrichment of Gd in the ionic form has been compared with strong cation exchange material Chromabond SA (SCX), weak ion exchange material Chelex-100 and also with lanthanide specific HDEHP modified reverse phase C18. The determination of Gd and its complexes after enrichment were performed using inductively coupled plasma mass spectrometry (ICP-MS) and on the basis of 158Gd. Among the three SPE materials, HDEHP coated reverse phase C18 SPE has been found to be most efficient, yielding a hundredfold Gd enrichment with > 95% recovery for linear and cyclic contrast agents like Gd-DTPA (Magnevist), Gd-DOTA (Dotarem), Gd-BOPTA (Multihance), and Gd-BT-DO3A (Gadovist). The developed SPE method has been successfully applied to the surface water and waste water samples originated from different places in Berlin, Germany. The results were in good agreement with the results obtained with direct measurement with ICP-MS. The developed pre-concentration method can be efficiently used for the determination of trace levels of gadolinium in the environment even with less sensitive analytical techniques. KW - Solid phase extraction KW - Magnetic resonance imaging KW - Gadolinium KW - Gd based contrast agents KW - Chelex-100 KW - HDEHP KW - Speciation PY - 2010 U6 - https://doi.org/10.1039/c003251d SN - 0267-9477 SN - 1364-5544 VL - 25 IS - 10 SP - 1573 EP - 1580 PB - Royal Society of Chemistry CY - London AN - OPUS4-21985 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nan, A. A1 - Turcu, R. A1 - Craciunescu, I. A1 - Pana, O. A1 - Scharf, Holger A1 - Liebscher, J. T1 - Microwave-assisted graft polymerization of epsilon-Caprolactone onto magnetite N2 - The graft polymerization of ε-caprolactone (ε-CL) onto magnetite was carried out under microwave irradiation in the presence of tin(II) 2-ethylhexanoate. The molar ratio of ε-CL to tin(II) 2-ethylhexanoate was 300, whereas the molar ratio of ε-CL to magnetite was 5. The chemical structures of the obtained poly(ε-caprolactone) coated magnetic nanoparticles were characterized by FTIR and XPS spectroscopy. These magnetic-polymer hybrid nanostructures were further investigated by X-ray diffraction and magnetization measurements. The morphology of the magnetic core-shell nanostructures were determined by TEM. KW - Magnetite KW - Epsilon-caprolactone KW - Magnetic core shell nanoparticles KW - Microwave KW - Nanoparticles KW - Polymerization KW - Ring-opening polymerization PY - 2009 U6 - https://doi.org/10.1002/pola.23589 SN - 0360-6376 SN - 0887-624X VL - 47 IS - 20 SP - 5397 EP - 5404 PB - Wiley CY - Hoboken, NJ AN - OPUS4-20022 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Scharf, Holger A1 - Bremser, Wolfram T1 - Certification of a reference material for determination of total cyanide in soil to support implementation of the international standard ISO 11262:2011 N2 - Cyanides are among the most important inorganic pollutants to be tested and monitored in environmental compartments. They can be distinguished and determined as free cyanide, weak acid dissociable cyanide or as total cyanide. However, in any case obtained, measurement results are operationally defined referring to the applied analytical method. In 2011, the International Standard ISO 11262 has been published which specifies a normative analytical method for the determination of total cyanide in soil. The objective of the project described in this paper was to provide the first soil reference material (CRM) certified for its mass fraction of total cyanide on the basis of this standard. A total of 12 German laboratories with proven experience in the determination of cyanides in environmental samples participated in the certification study. Measurement results were evaluated in full compliance with the requirements of ISO Guide 35. Taking into account the results of the inter-laboratory comparison as well as the outcome of the homogeneity and stability studies, a certified mass fraction of total cyanide of 21.1 mg/kg and an expanded uncertainty (k=2) of 1.3 mg/kg were assigned to the material. The reference material has been issued as CRM BAM-U114. KW - Certified reference material KW - Total cyanide KW - Soil KW - Quality assurance KW - International standard PY - 2015 U6 - https://doi.org/10.1007/s00216-014-8149-1 SN - 1618-2642 SN - 1618-2650 VL - 407 IS - 11 SP - 3219 EP - 3223 PB - Springer CY - Berlin AN - OPUS4-33023 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Peplinski, Burkhard A1 - Adamczyk, Burkart A1 - Formanek, P. A1 - Meyer, Christian A1 - Krüger, O. A1 - Scharf, Holger A1 - Reinsch, Stefan A1 - Ostermann, Markus A1 - Nofz, Marianne A1 - Jäger, Christian A1 - Adam, Christian A1 - Emmerling, Franziska T1 - Nanocrystalline and stacking-disordered beta-cristobalite AlPO4 chemically stabilized at room temperature: synthesis, physical characterization, and X-ray powder diffraction data N2 - This paper reports the first successful synthesis and the structural characterization of nanocrystalline and stacking-disordered β-cristobalite AlPO4 that is chemically stabilized down to room temperature and free of crystalline impurity phases. Several batches of the title compound were synthesized and thoroughly characterized by X-ray powder diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy, selected area electron diffraction, energy dispersive X-ray spectroscopy mapping in SEM, solid-state 31P nuclear magnetic resonance (31P-NMR) spectroscopy including the TRAPDOR method, differential thermal analysis (DTA), gas-sorption methods, optical Emission spectroscopy, X-ray fluorescence spectroscopy, and ion chromatography. Parameters that are critical for the synthesis were identified and optimized. The synthesis procedure yields reproducible results and is well documented. A high-quality XRD pattern of the title compound is presented, which was collected with monochromatic copper radiation at room temperature in a wide 2θ range of 5°–100°. KW - Stabilization of high-temperature phase at RT KW - Nanochrystalline AlPO4 KW - Beta-christobalite structure type KW - High-cristobalite form KW - Aluminium phosphate PY - 2017 U6 - https://doi.org/10.1017/S0885715617000537 SN - 1945-7413 SN - 0885-7156 VL - 32 IS - S1 SP - S193 EP - S200 PB - JCPDS-ICDD CY - Cambridge AN - OPUS4-42235 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wienold, Julia A1 - Recknagel, Sebastian A1 - Scharf, Holger A1 - Hoppe, Marion A1 - Michaelis, Matthias T1 - Elemental analysis of printed circuit boards considering the ROHS regulations N2 - The EU RoHS Directive (2002/95/EC of the European Parliament and of the Council) bans the placing of new electrical and electronic equipment containing more than agreed levels of lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE) flame retardants on the EU market. It necessitates methods for the evaluation of RoHS compliance of assembled electronic equipment. In this study mounted printed circuit boards from personal computers were analyzed on their content of the three elements Cd, Pb and Hg which were limited by the EU RoHS directive. Main focus of the investigations was the influence of sample pre-treatment on the precision and reproducibility of the results. The sample preparation steps used were based on the guidelines given in EN 62321. Five different types of dissolution procedures were tested on different subsequent steps of sample treatment like cutting and milling. Elemental analysis was carried out using ICP–OES, XRF and CV–AFS (Hg). The results obtained showed that for decision-making with respect to RoHS compliance a size reduction of the material to be analyzed to particles ≤1.5 mm can already be sufficient. However, to ensure analytical results with relative standard deviations of less than 20%, as recommended by the EN 62321, a much larger effort for sample processing towards smaller particle sizes might be required which strongly depends on the mass fraction of the element under investigation. KW - RoHS KW - Printed circuit boards KW - Electrotechnical products KW - Elemental composition PY - 2011 U6 - https://doi.org/10.1016/j.wasman.2010.10.002 SN - 0956-053X VL - 31 IS - 3 SP - 530 EP - 535 PB - Elsevier Ltd. CY - New York, NY AN - OPUS4-23986 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -