TY - JOUR A1 - Hein, Sebastian A1 - Philipp, Rosemarie A1 - Duewer, D.L. A1 - Gasca-Aragon, H. A1 - Lippa, K. A1 - Toman, B. A1 - Bremser, Wolfram A1 - Calderon, M.A.Á. A1 - Castorena, A.P. A1 - Caixeiro, J.M.R. A1 - Do Rego, E.C.P. A1 - Rosso, A. A1 - De Arechavaleta, R. A1 - O'Connor, G. A1 - Holcombe, G. A1 - Ellison, S.L.R. A1 - Splett, J.D. A1 - Schantz, M.M. A1 - Sharpless, K.E. A1 - Croft, M. A1 - Archer, M. A1 - De Vos, J. A1 - Konopelko, L.A. A1 - Kustikov, Y. T1 - Final report on CCQM-K79: Comparison of value-assigned CRMs and PT materials: Ethanol in aqueous matrix N2 - The 2010 CCQM-K79 'Comparison of value-assigned CRMs and PT materials: Ethanol in aqueous media' is the second key comparison directly testing the chemical measurement services provided to customers by National Metrology Institutes (NMIs) and Designated Institutes (DIs). CCQM-K79 compared the assigned ethanol values of proficiency test (PT) and certified reference materials (CRMs) using measurements made on these materials under repeatability conditions. Nine NMIs submitted 27 CRM or value-assigned PT materials for evaluation. These materials represent many of the higher-order reference materials then available for this commercially and forensically important measurand. The assigned ethanol mass fraction in the materials ranged from 0.1 mg/kg to 334 mg/kg. All materials were stored and prepared according the specifications provided by each NMI. Samples were processed and analyzed under repeatability conditions by one analytical team using a gas chromatography with flame ionization detection (GC-FID) method of demonstrated trueness and precision. Given the number of materials and the time required for each analysis, the majority of the measurements were made in two measurement campaigns ('runs'). Due to a shipping delay from one NMI, an unanticipated third campaign was required. In all three campaigns, replicate analyses (three injections of one preparation separated in time) were made for one randomly selected unit of each of the 27 materials. Nine of the 27 materials were gravimetrically diluted before measurement to provide solutions with ethanol mass fraction in the established linear range of the GC-FID method. The repeatability measurement value for each analyzed solution was estimated as the mean of all replicate values. The within- and between-campaign variance components were estimated using one-way ANOVA. Markov Chain Monte Carlo Bayesian analysis was used to estimate 95% level-of-confidence coverage intervals for the mean values. Uncertainty-weighted generalized distance regression was used to establish the key comparison reference function (KCRF) relating the assigned values to the repeatability measurements. On the basis of leave-one-out cross-validation, all of the assigned values for all 27 materials were deemed equivalent at the 95% level of confidence. These materials were used to define the KCRF. Parametric bootstrap Monte Carlo was used to estimate 95% level-of-confidence coverage intervals for the degrees of equivalence of materials, d ± U95(d), and of the participating NMIs, D ± U95(D). Because of the very wide range of ethanol mass fraction in the materials, these degrees of equivalence are expressed in percent relative form: %d ± U95(%d) and %D ± U95(%D). The median of the absolute values of the %D for the participating NMIs is less than 0.05% with a median U95(%D) of less than 1%. These results demonstrate that the participating NMIs have the ability to correctly value-assign CRMs and proficiency test materials for ethanol in aqueous media and similar measurands. PY - 2013 U6 - https://doi.org/10.1088/0026-1394/50/1A/08005 SN - 0026-1394 SN - 1681-7575 VL - 50 IS - 1A / Technical Suppl. 2013 / 08005 SP - 1 EP - 49 PB - Inst. of Physics Publ. CY - Bristol AN - OPUS4-27730 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Philipp, Rosemarie A1 - Schantz, M. A1 - Urquiza, M.P. A1 - Calderón, M.A.A. A1 - Torres, M.M. A1 - Carter, D. A1 - O'Connor, G. A1 - Sejeroe-Olsen, B. A1 - Ricci, M. A1 - Lalere, B. A1 - Peignaux, M. A1 - Kim, D.-H. A1 - Itoh, N. A1 - Wong, S.-K. A1 - Man, T.O. A1 - Caixeiro, J.M.R. T1 - CCQM-K50: Polycyclic aromatic hydrocarbons (PAHs) in soil/particulate matter PY - 2010 U6 - https://doi.org/10.1088/0026-1394/47/1A/08006 SN - 0026-1394 SN - 1681-7575 VL - 47 SP - 08006-1 - 08006-47 PB - Inst. of Physics Publ. CY - Bristol AN - OPUS4-20821 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Westwood, S. A1 - Josephs, R. A1 - Choteau, T. A1 - Daireaux, A. A1 - Mesquida, C. A1 - Wielgosz, R. A1 - Rosso, A. A1 - de Arechavaleta, M.R. A1 - Davies, S. A1 - Wang, H. A1 - do Rego, E.C.P. A1 - Rodrigues, J.M. A1 - de Freitas Guimaraes, E. A1 - Sousa, M.V.B. A1 - Monteiro, T.M. A1 - das Neves Valente, L.A. A1 - Violante, F.G.M. A1 - Almeida, R. R. R. A1 - Quaresma, M.C.B. A1 - Nogueira, R. A1 - Windust, A. A1 - Dai, X. A1 - Li, X. A1 - Zhang, W. A1 - Li, M. A1 - Shao, M. A1 - Wei, C. A1 - Wong, S.-K. A1 - Cabillic, J. A1 - Gantois, F. A1 - Philipp, Rosemarie A1 - Pfeifer, Dietmar A1 - Hein, Sebastian A1 - Klyk-Seitz, Urszula-Anna A1 - Ishikawa, K. A1 - Castro, E. A1 - Gonzalez, N. A1 - Krylov, A. A1 - Lin, T.T. A1 - Kooi, L.T. A1 - Fernandes-Whaley, M. A1 - Prévoo, D. A1 - Archer, M. A1 - Visser, R. A1 - Nlhapo, N. A1 - de Vos, B. A1 - Ahn, S. A1 - Pookrod, P. A1 - Wiangnon, K. A1 - Sudsiri, N. A1 - Muaksang, K. A1 - Cherdchu, C. A1 - Gören, A.C. A1 - Bilsel, M. A1 - LeGoff, T. A1 - Bearden, D. A1 - Bedner, M. A1 - Duewer, D. A1 - Hancock, D. A1 - Lang, B. A1 - Lippa, K. A1 - Schantz, M. A1 - Sieber, j. T1 - Final report on key comparison CCQM-K55.b (aldrin): An international comparison of mass friction purity assignment of aldrin N2 - Under the auspices of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a key comparison, CCQM K55.b, was coordinated by the Bureau International des Poids et Mesures (BIPM) in 2010/2011. Nineteen national measurement institutes and the BIPM participated. Participants were required to assign the mass fraction of aldrin present as the main component in the comparison sample for CCQM-K55.b which consisted of technical grade aldrin obtained from the National Measurement Institute Australia that had been subject to serial recrystallization and drying prior to sub-division into the units supplied for the comparison. Aldrin was selected to be representative of the performance of a laboratory's measurement capability for the purity assignment of organic compounds of medium structural complexity [molar mass range 300 Da to 500 Da] and low polarity (pKOW < -2) for which related structure impurities can be quantified by capillary gas phase chromatography (GC). The key comparison reference value (KCRV) for the aldrin content of the material was 950.8 mg/g with a combined standard uncertainty of 0.85 mg/g. The KCRV was assigned by combination of KCRVs assigned by consensus from participant results for each orthogonal impurity class. The relative expanded uncertainties reported by laboratories having results consistent with the KCRV ranged from 0.3% to 0.6% using a mass balance approach and 0.5% to 1% using a qNMR method. The major analytical challenge posed by the material proved to be the detection and quantification of a significant amount of oligomeric organic material within the sample and most participants relying on a mass balance approach displayed a positive bias relative to the KCRV (overestimation of aldrin content) in excess of 10 mg/g due to not having adequate procedures in place to detect and quantify the non-volatile content–specifically the non-volatile organics content–of the comparison sample. There was in general excellent agreement between participants in the identification and the quantification of the total and individual related structure impurities, water content and the residual solvent content of the sample. The comparison demonstrated the utility of 1H NMR as an independent method for quantitative analysis of high purity compounds. In discussion of the participant results it was noted that while several had access to qNMR estimates for the aldrin content that were inconsistent with their mass balance determination they decided to accept the mass balance result and assumed a hidden bias in their NMR data. By contrast, laboratories that placed greater confidence in their qNMR result were able to resolve the discrepancy through additional studies that provided evidence of the presence of non-volatile organic impurity at the requisite level to bring their mass balance and qNMR estimates into agreement. PY - 2012 U6 - https://doi.org/10.1088/0026-1394/49/1A/08014 SN - 0026-1394 SN - 1681-7575 VL - 49 IS - CCQM-K55.b Final Report October 2012 SP - 1 EP - 41 PB - Inst. of Physics Publ. CY - Bristol AN - OPUS4-26831 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Westwood, S. A1 - Josephs, R. A1 - Daireaux, A. A1 - Wielgosz, R. A1 - Davies, S. A1 - Wang, H. A1 - Rodrigues, J. A1 - Wollinger, W. A1 - Windust, A. A1 - Kang, M. A1 - Fuhai, S. A1 - Philipp, Rosemarie A1 - Kuhlich, Paul A1 - Wong, S.-K. A1 - Shimizu, Y. A1 - Pérez, M. A1 - Avila, M. A1 - Fernandes-Whaley, M. A1 - Prevoo, D. A1 - de Vos, J. A1 - Visser, R. A1 - Archer, M. A1 - LeGoff, T. A1 - Wood, S. A1 - Bearden, D. A1 - Bedner, M. A1 - Boroujerdi, A. A1 - Duewer, D. A1 - Hancock, D. A1 - Lang, B. A1 - Porter, B. A1 - Schantz, M. A1 - Sieber, J. A1 - White, E. A1 - Wise, S. A. T1 - Final report on key comparison CCQM-K55.a (estradiol): an international comparison of mass fraction purity assignment of estradiol N2 - Under the auspices of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a key comparison, CCQM K55.a, was coordinated by the Bureau International des Poids et Mesures (BIPM) in 2009/2010. Eleven national measurement institutes and the BIPM participated. Participants were required to assign the mass fraction of estradiol present as the main component in the comparison sample (CCQM-K55.a) which consisted of a bulk estradiol hemihydrate material obtained from a commercial supplier that had been extensively but not exhaustively dried prior to sub-division into the units supplied for the comparison. Estradiol was selected to be representative of the performance of a laboratory's measurement capability for the purity assignment of organic compounds of medium structural complexity [molar mass range 300–500 Da] and low polarity (pKOW < -2) for which related structure impurities can be quantified by capillary gas phase chromatography (GC) or by high performance liquid chromatography (LC). The majority of participants used a mass balance approach to determine the estradiol content. The key comparison reference value (KCRV) for estradiol in CCQM-K55.a was assigned by combination of KCRVs assigned by consensus from participant results for each orthogonal impurity class. This allowed participants to demonstrate the efficacy (or otherwise) of their implementation of the mass balance approach and to demonstrate that their assigned value for the main component agreed with the KCRV through use of internally consistent contributing methods. The KCRV for the estradiol content of the material was 984.3 mg/g with a combined standard uncertainty of 0.42 mg/g. The individual participant results showed that a relative expanded uncertainty for the purity assignment of 0.2% is a reasonable estimate of the best achievable result by an individual laboratory for a material of this complexity available in this amount at this level of purity. The relative expanded uncertainties reported by laboratories having results consistent with the KCRV ranged from 0.2% to 0.8%. The review of results that were biased from the KCRV showed that two major analytical challenges are posed by the material: the measurement of its water content and controlling for related substance artefact formation during the analysis process. The results displaying a positive bias relative to the KCRV (overestimation of estradiol content) were due to underestimation of the water content of the material, while those with a negative bias (underestimation of estradiol) overestimated the total related substance impurities through a failure to detect and control for artefact formation arising from in situ oxidative dimerization of estradiol in neutral solution prior to analysis. There was however good agreement between all participants in the identification and the quantification of the individual related structure impurities actually present in the sample. The comparison also demonstrated the utility of high-field 1H NMR for both quantitative and qualitative analysis of high purity compounds. It is noted that all the participants who used qNMR as a major or contributing technique and included it as part of, combined it or confirmed it with a conventional 'mass balance' data estimate, obtained results consistent with the KCRV. PY - 2012 U6 - https://doi.org/10.1088/0026-1394/49/1A/08009 SN - 0026-1394 SN - 1681-7575 VL - 49 IS - 1A Tech. Suppl. / 08009 SP - 1 EP - 33 PB - Inst. of Physics Publ. CY - Bristol AN - OPUS4-26411 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Urquiza, M.P. A1 - Torres, M.M. A1 - Mitani, Y. A1 - Schantz, M.M. A1 - Duewer, D.L. A1 - May, W.E. A1 - Parris, R.M. A1 - Wise, S. A. A1 - Kaminski, Katja A1 - Philipp, Rosemarie A1 - Win, Tin A1 - Rosso, A. A1 - Kim, D.H. A1 - Ishikawa, K. A1 - Krylov, A.I. A1 - Kustikov, Y.A. A1 - Baldan, A. T1 - Final report on CCQM-K47: Volatile organic compounds in methanol N2 - KEY COMPARISON At the October 2005 CCQM Organic Analysis Working Group Meeting (IRMM, Belgium), the decision was made to proceed with a Key Comparison study (CCQM-K47) addressing the calibration function for the determination of volatile organic compounds (VOCs) used for water quality monitoring. This was coordinated by CENAM and NIST. Benzene, o-xylene, m-xylene and p-xylene were chosen as representative VOCs. The solvent of choice was methanol. Key Comparison CCQM-K47 demonstrated the capabilities of participating NMIs to identify and measure the four target VOCs in a calibration solution using GC-based methods. The measurement challenges in CCQM-K47, such as avoiding volatility loss, achieving adequate chromatographic resolution and isolating potential interferences, are typical of those required for value-assigning volatile reference materials. Participants achieving comparable measurements for all four VOCs in this Key Comparison should be capable of providing reference materials and measurements for VOCs in solutions when present at concentration levels greater than 10 µg/g. PY - 2013 U6 - https://doi.org/10.1088/0026-1394/50/1A/08021 SN - 0026-1394 SN - 1681-7575 VL - 50 SP - 08021, 1 EP - 24 PB - Inst. of Physics Publ. CY - Bristol AN - OPUS4-31071 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zeleny, R. A1 - Voorspoels, S. A1 - Ricci, M. A1 - Becker, Roland A1 - Jung, Christian A1 - Bremser, Wolfram A1 - Sittidech, M. A1 - Panyawathanakit, N. A1 - Wong, W. F. A1 - Choi, S.M. A1 - Lo, K.C. A1 - Yeung, W. Y. A1 - Kim, D.H. A1 - Han, J. A1 - Ryu, J. A1 - Mingwu, S. A1 - Chao, W. A1 - Schantz, M.M. A1 - Lippa, K.A. A1 - Matsuyama, S. T1 - Evaluation of the state-of-the-art measurement capabilities for selected PBDEs and decaBB in plastic by the international intercomparison CCQM-P114 N2 - An international intercomparison involving eight national metrology institutes (NMIs) was conducted to establish their current measurement capabilities for determining five selected congeners from the brominated flame retardant classes polybrominated diphenyl ethers and polybrominated biphenyls. A candidate reference material consisting of polypropylene fortified with technical mixtures of penta-, octa- and decabromo diphenyl ether and decabromo biphenyl, which was thoroughly assessed for material homogeneity and stability, was used as study material. The analytical procedures applied by the participants differed with regard to sample pre-treatment, extraction, clean-up, employed calibrants and type of calibration procedure as well as regarding analytical methods used for separation, identification and quantification of the flame retardant congeners (gas chromatography coupled to an electron capture detector (GC-ECD), gas chromatography-mass spectrometry in the electron ionisation mode (GC-EI-MS), gas chromatography-mass spectrometry in the electron capture negative ionisation mode (GC-ECNI-MS), and liquid chromatography-inductive coupled plasma-mass spectrometry (LC-ICP-MS)). The laboratory means agreed well with relative standard deviations of the mean of means of 1.9%, 4.8%, 5.5% and 5.4% for brominated diphenyl ether (BDE) 47, 183 and 209 and for the brominated biphenyl (BB) congener 209, respectively. For BDE 206, a relative standard deviation of 28.5% was obtained. For all five congeners, within-laboratory relative standard deviations of six measurements obtained under intermediate precision conditions were between 1% and 10%, and reported expanded measurements uncertainties typically ranged from 4% to 10% (8% to 14% for BDE 206). Furthermore, the results are in good agreement with those obtained in the characterization exercise for determining certified values for the flame retardant congeners in the same material. The results demonstrate the state-of-the-art measurement capabilities of NMIs for quantifying representative BDE congeners and BB 209 in a polymer. The outcome of this intercomparison (pilot study) in conjunction with possible improvements for employing exclusively calibrants with thoroughly assessed purity suggests that a key comparison aiming at underpinning calibration and measurement capability (CMC) claims of NMIs can be conducted. KW - Flame retardants KW - Polymer KW - Polybrominated diphenyl ethers (PBDEs) KW - Polybrominated biphenyls (PBBs) KW - International intercomparison PY - 2010 U6 - https://doi.org/10.1007/s00216-009-3314-7 SN - 1618-2642 SN - 1618-2650 VL - 396 IS - 4 SP - 1501 EP - 1511 PB - Springer CY - Berlin AN - OPUS4-22905 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Duewer, D.L. A1 - May, W.E. A1 - Parris, R.M. A1 - Schantz, M.M. A1 - Wise, S. A. A1 - Piechotta, Christian A1 - Philipp, Rosemarie A1 - Win, Tin A1 - Avila, M. A1 - Pérez Urquiza, M. A1 - Ulberth, F. A1 - Kim, B. A1 - Ishikawa, K. A1 - Chen, D. A1 - Krylov, A.I. A1 - Kustidov, Y.A. A1 - Lopushanskaya, E.M. T1 - Final report on CCQM-K38: Determination of PAHs in solution PY - 2009 U6 - https://doi.org/10.1088/0026-1394/46/1A/08003 SN - 0026-1394 SN - 1681-7575 VL - 46 IS - 08003 SP - 1 EP - 13 PB - Inst. of Physics Publ. CY - Bristol AN - OPUS4-20029 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Westwood, S. A1 - Josephs, R. A1 - Daireaux, A. A1 - Wielgosz, R. A1 - Davies, S. A1 - Kang, M. A1 - Ting, H. A1 - Philipp, Rosemarie A1 - Malz, Frank A1 - Shimizu, Y. A1 - Frias, E. A1 - Pérez, M. A1 - Apps, P. A1 - Fernandes-Whaley, M. A1 - De Vos, B. A1 - Wiagnon, K. A1 - Ruangrittinon, N. A1 - Wood, S. A1 - Duewer, D.L. A1 - Schantz, M.M. A1 - Bedner, M. A1 - Hancock, D. A1 - Esker, J. T1 - An international comparison of mass fraction purity assignment of theophylline: CCQM pilot study CCQM-P20.e (Theophylline) PY - 2009 U6 - https://doi.org/10.1088/0026-1394/46/1A/08019 SN - 0026-1394 SN - 1681-7575 VL - 46 IS - 08019 SP - 1 EP - 37 PB - Inst. of Physics Publ. CY - Bristol AN - OPUS4-20030 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Westwood, S. A1 - Josephs, R. A1 - Choteau, T. A1 - Daireaux, A. A1 - Wielgosz, R. A1 - Davies, S. A1 - Moad, M. A1 - Chan, B. A1 - Munoz, A. A1 - Conneely, P. A1 - Ricci, M. A1 - Do Rego, E.C.P. A1 - Garrido, B.C. A1 - Violante, F.G.M. A1 - Windust, A. A1 - Dai, X. A1 - Huang, T. A1 - Zhang, W. A1 - Su, F. A1 - Quan, C. A1 - Wang, H. A1 - Lo, M. A1 - Wong, W. A1 - Gantois, F. A1 - Lalerle, B. A1 - Dorgerloh, Ute A1 - Koch, Matthias A1 - Klyk-Seitz, Urszula-Anna A1 - Pfeifer, Dietmar A1 - Philipp, Rosemarie A1 - Piechotta, Christian A1 - Recknagel, Sebastian A1 - Rothe, Robert A1 - Yamazaki, T. A1 - Zakaria, O. B. A1 - Castro, E. A1 - Balderas, M. A1 - González, N. A1 - Salazar, C. A1 - Regalado, L. A1 - Valle, E. A1 - Rodríguez, L. A1 - Laguna, L.Á.. A1 - Ramírez, P. A1 - Avila, M. A1 - Ibarra, J. A1 - Valle, L. A1 - Arce, M. A1 - Mitani, Y. A1 - Konopelko, L. A1 - Krylov, A. A1 - Lopushanskaya, E. A1 - Lin, T.T. A1 - Liu, Q. A1 - Kooi, L.T. A1 - Fernandes-Whaley, M. A1 - Prevoo-Franzsen, D. A1 - Nhlapo, N. A1 - Visser, R. A1 - Kim, B. A1 - Lee, H. A1 - Kankaew, P. A1 - Pookrod, P. A1 - Sudsiri, N. A1 - Shearman, K. A1 - Gören, A.C. A1 - Bilsel, G. A1 - Yilmaz, H. A1 - Bilsel, M. A1 - Cergel, M. A1 - Coskun, F.G. A1 - Uysal, E. A1 - Gündüz, S. A1 - Ün, I. A1 - Warren, J. A1 - Bearden, D.W. A1 - Bedner, M. A1 - Duewer, D.L. A1 - Lang, B.E. A1 - Lippa, K.A. A1 - Schantz, M.M. A1 - Sieber, J.R. T1 - Final report on key comparison CCQM-K55.c (L-(+)-Valine): Characterization of organic substances for chemical purity N2 - KEY COMPARISON Under the auspices of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a key comparison, CCQM K55.c, was coordinated by the Bureau International des Poids et Mesures (BIPM) in 2012. Twenty National Measurement Institutes or Designated Institutes and the BIPM participated. Participants were required to assign the mass fraction of valine present as the main component in the comparison sample for CCQM-K55.c. The comparison samples were prepared from analytical grade L-valine purchased from a commercial supplier and used as provided without further treatment or purification. Valine was selected to be representative of the performance of a laboratory's measurement capability for the purity assignment of organic compounds of low structural complexity [molecular weight range 100–300] and high polarity (pKOW > –2). The KCRV for the valine content of the material was 992.0 mg/g with a combined standard uncertainty of 0.3 mg/g. The key comparison reference value (KCRV) was assigned by combination of KCRVs assigned from participant results for each orthogonal impurity class. The relative expanded uncertainties reported by laboratories having results consistent with the KCRV ranged from 1 mg/g to 6 mg/g when using mass balance based approaches alone, 2 mg/g to 7 mg/g using quantitative 1H NMR (qNMR) based approaches and from 1 mg/g to 2.5 mg/g when a result obtained by a mass balance method was combined with a separate qNMR result. The material provided several analytical challenges. In addition to the need to identify and quantify various related amino acid impurities including leucine, isoleucine, alanine and a-amino butyrate, care was required to select appropriate conditions for performing Karl Fischer titration assay for water content to avoid bias due to in situ formation of water by self-condensation under the assay conditions. It also proved to be a challenging compound for purity assignment by qNMR techniques. There was overall excellent agreement between participants in the identification and the quantification of the total and individual related structure impurities, water content, residual solvent and total non-volatile content of the sample. Appropriate technical justifications were developed to rationalise observed discrepancies in the limited cases where methodology differences led to inconsistent results. The comparison demonstrated that to perform a qNMR purity assignment the selection of appropriate parameters and an understanding of their potential influence on the assigned value is critical for reliable implementation of the method, particularly when one or more of the peaks to be quantified consist of complex multiplet signals. PY - 2014 U6 - https://doi.org/10.1088/0026-1394/51/1A/08010 SN - 0026-1394 SN - 1681-7575 VL - 51 SP - 08010, 1 EP - 44 PB - Inst. of Physics Publ. CY - Bristol AN - OPUS4-31072 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -