TY - JOUR A1 - Beck, Matthias A1 - Burkert, Andreas A1 - Harnisch, J. A1 - Isecke, Bernd A1 - Osterminski, K. A1 - Raupach, M. A1 - Schießl, P. A1 - Tian, W. A1 - Warkus, J. T1 - Deterioration model and input parameters for reinforcement corrosion N2 - The paper presents the damage model of German Research Unit 537 which was used as a working hypothesis for the development of a user-friendly design model. Excerpts from the laboratory experiments and numerical calculations processed in project A of the research unit are presented here. The excerpts include the quantification of self-corrosion, geometrical effects in the macrocell corrosion, development of corroding steel surface and pit depth as well as the quantification of the resistivity of the concrete and the corrosion of steel in cracked concrete. KW - Reinforcement corrosion KW - Macrocell corrosion model KW - Design for durability PY - 2012 U6 - https://doi.org/10.1002/suco.201200004 SN - 1464-4177 VL - 13 IS - 3 SP - 145 EP - 155 PB - Ernst & Sohn CY - Berlin AN - OPUS4-26581 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mundra, S. A1 - Samson, G. A1 - Masi, G. A1 - Achenbach, R. A1 - Bastidas, D. M. A1 - Bernal, S. A. A1 - Bignozzi, M. C. A1 - Criado, M. A1 - Cyr, M. A1 - Gartner, N. A1 - von Greve-Dierfeld, S. A1 - Legat, A. A1 - Nikoonasab, Ali A1 - Provis, J. L. A1 - Raupach, M. A1 - Gluth, Gregor T1 - Application of electrochemical methods for studying steel corrosion in alkali-activated materials N2 - Alkali-activated materials (AAMs) are binders that can complement and partially substitute the current use of conventional cement. However, the present knowledge about how AAMs protect steel reinforcement in concrete elements is incomplete, and uncertainties exist regarding the application of electrochemical methods to investigate this issue. The present review by EFC WP11-Task Force ‘Corrosion of steel in alkali-activated materials’ demonstrates that important differences exist between AAMs and Portland cement, and between different classes of AAMs, which are mainly caused by differing pore solution compositions, and which affect the outcomes of electrochemical measurements. The high sulfide concentrations in blast furnace slag-based AAMs lead to distinct anodic polarisation curves, unusually low open circuit potentials, and low polarisation resistances, which might be incorrectly interpreted as indicating active corrosion of steel reinforcement. No systematic study of the influence of the steel–concrete interface on the susceptibility of steel to corrosion in AAMs is available. Less common electrochemical methods present an opportunity for future progress in the field. KW - Alkali-activated materials KW - Reinforcement corrosion KW - Steel corrrosion KW - Electrochemical methods KW - Concrete PY - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-572241 SN - 1521-4176 VL - 74 IS - 7 SP - 988 EP - 1008 PB - Wiley-VCH CY - Weinheim AN - OPUS4-57224 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -