TY - JOUR A1 - Heisterkamp, I. A1 - Ratte, M. A1 - Schoknecht, Ute A1 - Gartiser, S. A1 - Kalbe, Ute A1 - Ilvonen, O. T1 - Ecotoxicological evaluation of construction products: inter-laboratory test with DSLT and percolation test eluates in an aquatic biotest battery N2 - Background A European inter-laboratory test with 29 participating laboratories investigated whether a battery of four ecotoxicological tests is suitable for assessing the environmental compatibility of construction products. For this purpose, a construction product was investigated with the dynamic surface leaching test (DIN CEN/TS 16637-2) and the percolation test (DIN CEN/TS 16637-3). The eluates were produced centrally by one laboratory and were tested by the participants using the following biotests: algae test (ISO 8692), acute daphnia test (ISO 6341), luminescent bacteria test (DIN EN ISO 11348), and fish egg test (DIN EN ISO 15088). As toxicity measures, EC50 and LID values were calculated. Results Toxic effects of the eluates were detected by all four biotests. The bacteria test was by far the most sensitive, followed by the algae test and the daphnia test; the fish egg test was the least sensitive for eluates of both leaching tests. The toxicity level of the eluates was very high in the bacteria, daphnia, and algae test, with lowest ineffective dilution values of LID = 70 to LID = 13,000 and corresponding EC50 values around or even below 1 volume percent. The reproducibility (approximated by interlaboratory variability) of the biotests was good (< 53%) to very good (< 20%), regardless of the toxicity level of the eluates. The reproducibility of the algae test was up to 80%, and thus still acceptable. Conclusion It can be confirmed that the combination of leaching and ecotoxicity tests is suitable to characterize with sufficient reproducibility the environmental impact posed by the release of hazardous substances from construction products. KW - Inter-laboratory test KW - Construction products KW - Leaching tests KW - Ecotoxicity tests KW - Grouts PY - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-529198 VL - 33 IS - 1 SP - Article number: 75 PB - Springer AN - OPUS4-52919 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gartiser, S. A1 - Heisterkamp, I. A1 - Schoknecht, Ute A1 - Bandow, Nicole A1 - Burkhardt, M. A1 - Ratte, M. A1 - Ilvonen, O. T1 - Recommendation for a test battery for the ecotoxicological evaluation of the environmental safety of construction products N2 - The European Construction Products Regulation allows Member States to adopt rules for evaluating the environmental impact of their buildings. The aim of the project was to develop recommendations for a test battery for the ecotoxicological assessment of the environmental impact of construction products for outdoor use and contribute to the European harmonization of test methods. From a shortlist of 39 products 20 products were included in the ecotoxicological testing program. Monolithic and plate-like construction products were eluted in the Dynamic Surface Leaching test (DSLT) in accordance with CEN/TS 16637-2, granular products were eluted in a one stage batch test in accordance with DIN EN 12457-1. The eluates were examined in four aquatic toxicity tests (algae, daphnia, luminescent bacteria, fish eggs), a genotoxicity test (umu test) and in the respirometer test (OECD 301 F). Here, low to very high ecotoxicity was observed (up to a dilution factor of 1536). Six out of 8 eluates, whose TOC exceeded 10 mg L⁻1 showed a good biodegradability above 75%. The intra-laboratory repeatability of the Lowest Ineffective Dilution (LID) usually was within ±1 dilution steps (ecotoxicity tests) and ±2 dilution steps (leaching and ecotoxicity tests). This is acceptable, when considering that the overall variability of sample preparation, leaching test, and bioassays add up. The conclusions lead to practical recommendations for a suitable combination of leaching and ecotoxicity tests. KW - Biodegradability KW - Construction products KW - Leaching tests KW - Exotoxicity PY - 2017 U6 - https://doi.org/10.1016/j.chemosphere.2016.12.115 SN - 0045-6535 SN - 1879-1298 VL - 171 SP - 580 EP - 587 PB - Elsevier Ltd. AN - OPUS4-38861 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gartiser, S. A1 - Heisterkamp, I. A1 - Schoknecht, Ute A1 - Burkhardt, M. A1 - Ratte, M. A1 - Ilvonen, O. A1 - Brauer, F. A1 - Brückmann, J. A1 - Dabrunz, A. A1 - Egeler, P. A1 - Eisl, A.-M. A1 - Feiler, U. A1 - Fritz, I. A1 - König, S. A1 - Lebertz, H. A1 - Pandard, P. A1 - Pötschke, G. A1 - Scheerbaum, D. A1 - Schreiber, F. A1 - Soldán, P. A1 - Weiß, R. A1 - Weltens, R. T1 - Results from a round robin test for the ecotoxicological evaluation of construction products using two leaching tests and an aquatic test battery N2 - A European round robin test according to ISO 5725-2 was conceptually prepared, realised, and evaluated. The aim was to determine the inter-laboratory variability of the overall process for the ecotoxicological characterization of construction products in eluates and bioassays. To this end, two construction products BAM-G1 (granulate) and HSR-2 (roof sealing sheet), both made of EPDM polymers (rubber), were selected. The granular construction product was eluted in a one stage batch test, the planar product in the Dynamic Surface Leaching test (DSLT). A total of 17 laboratories from 5 countries participated in the round robin test: Germany (12), Austria (2), Belgium (1), Czech Republic (1) and France (1). A test battery of four standardised ecotoxicity tests with algae, daphnia, luminescent bacteria and zebrafish eggs was used. As toxicity measures, EC50 and LID values were calculated. All tests, except the fish egg test, were basically able to demonstrate toxic effects and the level of toxicity. The reproducibility of test results depended on the test specimens and the test organisms. Generally, the variability of the EC50 or LID values increased with the overall level of toxicity. For the very toxic BAM-G1 eluate a relative high variability of CV ¼ 73%e110% was observed for EC50 in all biotests, while for the less toxic HSR-2 eluate the reproducibility of EC50 varied with sensitivity: it was very good (CV ¼ 9.3%) for the daphnia test with the lowest sensitivity, followed by the algae test (CV ¼ 36.4%). The luminescent bacteria test, being the most sensitive bioassay for HSR-2 Eluate, showed the highest variability (CV ¼ 74.8%). When considering the complex overall process the reproducibility of bioassays with eluates from construction products was acceptable. KW - Round robin test KW - Construction products KW - Leaching tests KW - Eluates KW - Ecotoxicity tests PY - 2017 U6 - https://doi.org/10.1016/j.chemosphere.2017.01.146 SN - 0045-6535 SN - 1879-1298 VL - 175 SP - 138 EP - 146 PB - Elsevier Ltd. AN - OPUS4-39174 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -