TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Marinenko, R.B. A1 - Rackwitz, Vanessa A1 - Bremser, Wolfram A1 - Unger, Wolfgang T1 - Determination of the k-values of copper-gold alloys with ED- and WD-EPMA - Results of an inter-laboratory comparison N2 - An inter-laboratory comparison organized as a pilot study (PS) has been performed under the umbrella of the Consultative Committee for Amount of Substance – Metrology in Chemistry (CCQM) / Surface Analysis Working Group (SAWG) with the objective to compare k-values measured with Electron Probe X-ray Microanalysis (EPMA) for copper-gold alloys. The k-value, defined as the ratio of the Xray photon intensity of an X-ray characteristic line of the unknown sample to the corresponding one in the reference material, is a rough estimate of the mass fraction of the respective element. Basically, the mass fractions can be calculated from the k-values after applying a matrix correction procedure, which includes empirical approaches, so that traceability gets lost. Due to its physical, measurable nature, the k-value has been selected in the present PS as the primary measurand. The mass fraction has been set as the secondary (derived) measurand. Both EDX and WDX have been employed. The WDX results and the overall comparability between the k-values obtained by EDX and WDX are still in progress. KW - Interlaboratory comparison KW - EDX KW - WDX KW - EPMA KW - K-values KW - Cu-Au alloy KW - CCQM PY - 2014 U6 - https://doi.org/10.1017/S1431927614005376 SN - 1431-9276 SN - 1435-8115 VL - 20 IS - Suppl. S 3 SP - 730 EP - 731 PB - Cambridge University Press CY - New York, NY AN - OPUS4-31338 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Procop, M. A1 - Rackwitz, Vanessa T1 - Check and specification of the performance of EDS systems attached to the SEM by means of a new test material EDS-TM002 and an updated evaluation software package EDS spectrometer test - Version 3.4. N2 - Four years ago BAM has made available via its webshop a test material, EDS-TM001, as well as an accompanying software package, "EDX spectrometer check", to be employed by both EDS (energy dispersive spectrometer) users and manufacturers to check and pecify, respectively, the performance of an EDS. KW - EDS detector KW - EDX KW - Test material KW - EDS-TM002 KW - EDS performance test KW - Software PY - 2013 U6 - https://doi.org/10.1017/S1431927613008271 SN - 1431-9276 SN - 1435-8115 VL - 19 IS - Suppl. 2 SP - 1256 EP - 1257 PB - Cambridge University Press CY - New York, NY AN - OPUS4-29421 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Rackwitz, Vanessa T1 - Prediction of detection limits of micro X-ray fluorescence (muXRF) KW - X-ray scattering KW - Limits of detection KW - Peak-to-background KW - Peak-to-noise KW - XRF KW - Modelling PY - 2012 U6 - https://doi.org/10.1017/S1431927612006563 SN - 1431-9276 SN - 1435-8115 VL - 18 IS - Suppl. 2 SP - 942 EP - 943 PB - Cambridge University Press CY - New York, NY AN - OPUS4-26754 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Rackwitz, Vanessa T1 - Gaining improved chemical composition by exploitation of compton-to-rayleigh intensity ratio in XRF analysis N2 - The high specificity of the coherent (Rayleigh), as well as incoherent (Compton) X-ray scattering to the mean atomic number of a specimen to be analyzed by X-ray fluorescence (XRF), is exploited to gain more information on the chemical composition. Concretely, the evaluation of the Compton-to-Rayleigh intensity ratio from XRF spectra and its relation to the average atomic number of reference materials via a calibration curve can reveal valuable information on the elemental composition complementary to that obtained from the reference-free XRF analysis. Particularly for matrices of lower mean atomic numbers, the sensitivity of the approach is so high that it can be easily distinguished between specimens of mean atomic numbers differing from each other by 0.1. Hence, the content of light elements which are “invisible” for XRF, particularly hydrogen, or of heavier impurities/additives in light materials can be calculated 'by difference' from the scattering calibration curve. The excellent agreement between such an experimental, empirical calibration curve and a synthetically generated one, on the basis of a reliable physical model for the X-ray scattering, is also demonstrated. Thus, the feasibility of the approach for given experimental conditions and particular analytical questions can be tested prior to experiments with reference materials. For the present work a microfocus X-ray source attached on an SEM/EDX (scanning electron microscopy/energy dispersive X-ray spectroscopy) system was used so that the Compton-to-Rayleigh intensity ratio could be acquired with EDX spectral data for improved analysis of the elemental composition. PY - 2014 U6 - https://doi.org/10.1021/ac5000619 SN - 0003-2700 SN - 1520-6882 VL - 86 IS - 14 SP - 6858 EP - 6864 PB - American Chemical Society CY - Washington, DC AN - OPUS4-31179 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Rackwitz, Vanessa A1 - Reuter, Dirk T1 - X-ray scattering and its benefits for X-ray spectrometry at the SEM PY - 2009 U6 - https://doi.org/10.1017/S1431927609094392 SN - 1431-9276 SN - 1435-8115 VL - 15 IS - Suppl. 2 SP - 1122 EP - 1123 PB - Cambridge University Press CY - New York, NY AN - OPUS4-19792 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Rackwitz, Vanessa A1 - Reuter, Dirk T1 - Micro-focus X-ray fluorescence (mu-XRF) as an extension of the analytical SEM KW - mu-XRF KW - SEM KW - EDS PY - 2010 U6 - https://doi.org/10.1017/S1431927610054115 SN - 1431-9276 SN - 1435-8115 VL - 16 IS - Suppl. 2 SP - 904 EP - 905 PB - Cambridge University Press CY - New York, NY AN - OPUS4-27220 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Radtke, Martin A1 - Vincze, L. A1 - Rackwitz, Vanessa A1 - Reuter, Dirk T1 - X-ray scattering in X-ray fluorescence spectra with X-ray tube excitation - Modelling, experiment, and Monte-Carlo simulation N2 - X-ray scattering may contribute significantly to the spectral background of X-ray fluorescence (XRF) spectra. Based on metrological measurements carried out with a scanning electron microscope (SEM) having attached a well characterised X-ray source (polychromatic X-ray tube) and a calibrated energy dispersive X-ray spectrometer (EDS) the accuracy of a physical model for X-ray scattering is systematically evaluated for representative samples. The knowledge of the X-ray spectrometer efficiency, but also of the spectrometer response functions makes it possible to define a physical spectral background of XRF spectra. Background subtraction relying on purely mathematical procedures is state-of-the-art. The results produced by the analytical model are at least as reliable as those obtained by Monte-Carlo simulations, even without considering the very challenging contribution of multiple scattering. Special attention has been paid to Compton broadening. Relevant applications of the implementation of the analytical model presented in this paper are the prediction of the limits of detection for particular cases or the determination of the transmission of X-ray polycapillary lenses. KW - X-ray scattering KW - X-ray fluorescence KW - Spectral background KW - Modelling KW - Monte-Carlo simulation PY - 2010 U6 - https://doi.org/10.1016/j.nimb.2010.09.017 SN - 0168-583X SN - 1872-9584 VL - 268 IS - 24 SP - 3568 EP - 3575 PB - Elsevier CY - Amsterdam AN - OPUS4-22357 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Salge, T. A1 - Terborg, R. A1 - Rackwitz, Vanessa T1 - Advanced elemental analysis with ED-EPMA, WD-EPMA and mu-XRF at a SEM N2 - It is a latent wish of any SEM/EDS (scanning electron microscope with an energy dispersive spectrometer) analyst to “see more” of the analyzed specimen, i.e. to improve the existing analytical figures of merit. One key issue are the relatively poor limits of detection (not below 0.1 mass-%) provided by energy dispersive X-ray spectrometry (EDX) with the conventional electron excitation (ED-EPMA). This is a consequence of relatively low peak-to-background ratios and reduced energy resolution when compared to wavelength dispersive spectrometry (WD-EPMA). Recent technological developments make possible to equip the SEM with a wavelength dispersive spectrometer (WDS), so that significantly better energy resolution can be attained. Also a relative new product that can be easily attached to a SEM/EDS system is a micro-focus X-ray source. Hence, it is possible to perform (micro-focus) X-ray fluorescence spectrometry (μ-XRF) and take advantage of the enhanced peak-to-background ratios (well suited for trace analysis). However, there are also some disadvantages: an increased measurement time and excitation with a high current in the 10s of nA range are usually required for WDS. μ-XRF provides more bulk information and poor limits of detection for light elements. By combining the advantages of these analytical techniques “seeing more” becomes possible. KW - ED-EPMA KW - WD-EPMA KW - (mu-)XRF KW - EDX PY - 2011 U6 - https://doi.org/10.1017/S1431927611003874 SN - 1431-9276 SN - 1435-8115 VL - 17 IS - Suppl. 2 SP - 600 EP - 601 PB - Cambridge University Press CY - New York, NY AN - OPUS4-26751 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rackwitz, Vanessa A1 - Hodoroaba, Vasile-Dan T1 - An attempt of exploiting the compton-to-rayleigh intensity ratio for improved analysis with muXRF at a SEM KW - X-ray scattering KW - Compton scattering KW - Rayleigh scattering KW - XRF PY - 2012 U6 - https://doi.org/10.1017/S1431927612006678 SN - 1431-9276 SN - 1435-8115 VL - 18 IS - Suppl. 2 SP - 964 EP - 965 PB - Cambridge University Press CY - New York, NY AN - OPUS4-26753 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rackwitz, Vanessa A1 - Krumrey, M. A1 - Laubis, C. A1 - Scholze, F. A1 - Hodoroaba, Vasile-Dan T1 - New reference and test materials for the characterization of energy dispersive X-ray spectrometers at scanning electron microscopes N2 - Checking the performance of energy dispersive X-ray spectrometers as well as validation of the results obtained with energy dispersive X-ray spectrometry (EDX) at a scanning electron microscope (SEM) involve the use of (certified) reference and dedicated test materials. This paper gives an overview on the test materials mostly employed by SEM/EDX users and accredited laboratories as well as on those recommended in international standards. The new BAM reference material EDS-CRM, which is currently in the process of certification, is specifically designed for the characterization of EDS systems at a SEM through calibration of the spectrometer efficiency in analytical laboratories in a simple manner. The certification of the spectra by means of a reference EDS is described. The focus is on the traceability of EDS efficiency which is ensured by measurements of the absolute detection efficiency of silicon drift detectors (SDD) and Si(Li) detectors at the laboratory of the PTB using the electron storage ring BESSY II as a primary X-ray source standard. A new test material in development at BAM for testing the performance of an EDS in the energy range below 1 keV is also briefly presented. KW - EDX KW - EDS KW - Performance check KW - SEM KW - Test materials KW - Spectrometer efficiency PY - 2015 U6 - https://doi.org/10.1007/s00216-014-8242-5 SN - 1618-2642 SN - 1618-2650 VL - 407 IS - 11 SP - 3045 EP - 3053 PB - Springer CY - Berlin AN - OPUS4-33025 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -