TY - INPR A1 - Tannenberg, Robert A1 - Tscheuschner, Georg A1 - Raab, Christopher A1 - Flemig, Sabine A1 - Döring, Sarah A1 - Ponader, Marco A1 - Thurmann, Melinda A1 - Paul, Martin A1 - Weller, Michael G. T1 - Simplified Sample Preparation and Lateral Flow Immunoassay for the Detection of Plant Viruses N2 - Lateral flow immunoassays (LFA) are widely used for decentralized testing, but their application for in-field plant virus diagnostics is often limited by tedious sample preparation. Here, we present a simplified dipstick LFA for the detection and monitoring of cowpea chlorotic mottle virus (CCMV) as a model plant pathogen. The assay employes a monoclonal mouse antibody for capture and a polyclonal rabbit antibody conjugated to 80-nm gold nanoparticles for detection. Conventional sample and conjugate pads are omitted, allowing the test strips to be dipped directly into wells containing plant extract and antibody-gold conjugate. In addition, no plastic casing was necessary, which significantly reduces waste. It was shown that CCMV concentrations as low as 4 μg/L or 400 pg per sample could be reliably detected in 15 minutes. Specificity tests confirmed that other plant viruses, cowpea mosaic virus (CPMV) and tobacco mosaic virus (TMV), did not produce false positive results. Furthermore, we describe a field-compatible sampling procedure using a manual punch and a disposable syringe. This step combines sample grinding, extraction, and conjugate reconstitution within the syringe frit, enabling the analysis of punched leaf discs without laboratory equipment. When applied to CCMV-infected cowpea plants, the assay revealed systemic infection before visual symptoms became apparent. This work demonstrates that simplified LFAs combined with innovative sampling techniques can provide sensitive, specific, and rapid diagnostics for crop monitoring and support early intervention strategies in agriculture. N2 - Lateral Flow Immunoassays (LFA) werden häufig für dezentrale Tests verwendet, aber ihre Anwendung für die Diagnose von Pflanzenviren im Feld wird oft durch die mühsame Probenvorbereitung eingeschränkt. Hier stellen wir einen vereinfachten Dipstick-LFA zum Nachweis und zur Überwachung des Cowpea Chlorotic Mottle Virus (CCMV) als Modellpflanzenpathogen vor. Der Assay verwendet einen monoklonalen Maus-Antikörper zum Einfangen des Virus und einen polyklonalen Kaninchen-Antikörper, der an 80-nm-Goldnanopartikel konjugiert ist, zum Nachweis. Herkömmliche Proben- und Konjugatpads entfallen, sodass die Teststreifen direkt in Vertiefungen getaucht werden können, die Pflanzenextrakt und Antikörper-Gold-Konjugat enthalten. Darüber hinaus war keine Kunststoffhülle erforderlich, was den Abfall erheblich reduziert. Es zeigte sich, dass CCMV-Konzentrationen von nur 4 μg/L oder 400 pg pro Probe innerhalb von 15 Minuten zuverlässig nachgewiesen werden konnten. Spezifitätstests bestätigten, dass andere Pflanzenviren, das Cowpea Mosaic Virus (CPMV) und das Tobacco Mosaic Virus (TMV), keine falsch positiven Ergebnisse lieferten. Darüber hinaus beschreiben wir ein feldtaugliches Probenahmeverfahren unter Verwendung eines manuellen Stanzers und einer Einwegspritze. Dieser Schritt kombiniert das Zerkleinern der Probe, die Extraktion und die Rekonstitution des Konjugats innerhalb der Spritzenfritte und ermöglicht so die Analyse von ausgestanzten Blattscheiben ohne Laborausrüstung. Bei der Anwendung auf CCMV-infizierte Augenbohnenpflanzen zeigte der Test eine systemische Infektion, bevor visuelle Symptome sichtbar wurden. Diese Arbeit zeigt, dass vereinfachte LFAs in Kombination mit innovativen Probenahmetechniken eine sensitive, spezifische und schnelle Diagnostik für die Überwachung von Nutzpflanzen ermöglichen und frühzeitige Interventionsstrategien in der Landwirtschaft unterstützen können. KW - Vigna unguiculata KW - Cowpea KW - Sample preparation KW - Plant pathogen KW - Mobile detection KW - Crop monitoring KW - Plastic waste KW - Lateral flow immunoassay KW - Plant virus KW - Sample pad KW - Conjugate pad PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-651731 DO - https://doi.org/10.20944/preprints202512.1492.v1 SP - 1 EP - 14 PB - MDPI CY - Basle, Switzerland AN - OPUS4-65173 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tannenberg, Robert A1 - Paul, Martin A1 - Röder, Bettina A1 - Gande, S. L. A1 - Sreeramulu, S. A1 - Saxena, K. A1 - Richter, C. A1 - Schwalbe, H. A1 - Swart, C. A1 - Weller, Michael G. T1 - Chemiluminescence biosensor for the determination of cardiac troponin I (cTnI) N2 - Cardiac troponin I (cTnI) is a crucial biomarker for diagnosing cardiac vascular diseases, including acute myocardial infarction (AMI). This study presents a proof-of-concept chemiluminescence-based immunosensor for rapid and accurate measurement of cTnI, with the potential for online monitoring. The immunosensor incorporates a flow cell design and a sensitive complementary metal-oxide-semiconductor (CMOS) camera for optical readout. A microfluidic setup was established to enable selective and quasi-online determination of cTnI within ten minutes. The sensor was tested with recombinant cTnI in phosphate buffer, demonstrating measurements in the concentration range of 2–25 µg/L, with a limit of detection (LoD) of 0.6 µg/L (23 pmol/L) achieved using the optimized system. The immunosensor exhibited high selectivity, as no cross-reactivity was observed with other recombinant proteins such as cTnT and cTnC at a concentration of 16 µg/L. Measurements with diluted blood plasma and serum yielded an LoD of 60 µg/L (2.4 nmol/L) and 70 µg/L (2.9 nmol/L), respectively. This biosensor offers a promising approach for the rapid and sensitive detection of cTnI, contributing to the diagnosis and management of acute myocardial infarction and other cardiac vascular diseases. N2 - Das kardiale Troponin I (cTnI) ist ein wichtiger Biomarker für die Diagnose von Herz-Kreislauf-Erkrankungen, einschließlich des akuten Myokardinfarkts (AMI). In dieser Studie wird ein auf Chemilumineszenz basierender Immunsensor für die schnelle und genaue Messung von cTnI vorgestellt, der das Potenzial für eine Online-Überwachung hat. Der Immunsensor besteht aus einer Durchflusszelle und einer empfindlichen CMOS-Kamera (Complementary Metal-Oxide-Semiconductor) zur optischen Detektion. Es wurde ein mikrofluidischer Aufbau entwickelt, der eine selektive und quasi Online-Bestimmung von cTnI innerhalb von zehn Minuten ermöglicht. Der Sensor wurde mit rekombinantem cTnI in Phosphatpuffer getestet und zeigte einen Messbereich von 2-25 µg/L, wobei mit dem optimierten System eine Nachweisgrenze (LoD) von 0,6 µg/L (23 pmol/L) erreicht wurde. Der Immunsensor zeigte eine hohe Selektivität, da keine Kreuzreaktivität mit anderen rekombinanten Proteinen wie cTnT und cTnC bei einer Konzentration von 16 µg/L beobachtet wurde. Messungen mit verdünntem Blutplasma und Serum ergaben einen LoD von 60 µg/L (2,4 nmol/L) bzw. 70 µg/L (2,9 nmol/L). Dieser Biosensor bietet einen vielversprechenden Ansatz für den schnellen und empfindlichen Nachweis von cTnI, der zur Diagnose und Behandlung des akuten Myokardinfarkts und anderer kardialer Gefäßerkrankungen beitragen kann. KW - Acute myocardial infarction KW - Heart attack KW - Emergency KW - Diagnosis KW - Cardiac troponin KW - Biomarker KW - Immunosensor KW - Biosensor KW - Chemiluminescence KW - Luminol KW - Peroxidase KW - Monoclonal antibodies KW - Flow injection immunoassay KW - Immunometric assay KW - Immunometric biosensor KW - Microfluidic system KW - Monolithic column KW - Online biosensor PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-575471 DO - https://doi.org/10.3390/bios13040455 SN - 2079-6374 VL - 13 IS - 4 SP - 1 EP - 20 PB - MDPI CY - Basel AN - OPUS4-57547 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tannenberg, Robert A1 - Paul, Martin A1 - Fünning, Tabea A1 - Schuhmann, Christoph A1 - Weller, Michael G. A1 - Steglich, Patrick T1 - Multichannel real-time detection of biomarkers with highly miniaturized photonic microchips N2 - The development of novel photonic integrated microchips (PIC) is a promising approach to allow for the convenient detection of key biomarkers in complex matrices through multichannel real-time analysis in a highly compact package. This study reports the successful development and application of a backside released CMOS chip designed for the multichannel real-time detection of biomarkers. Operating at the C-band at approx. 1550 nm, the microchip features three dedicated detection sensors in addition to a reference sensor, enabling simultaneous analysis of multiple biomarkers. The compact and highly miniaturized design of this microchip, with a footprint of just 1 mm², positions it as promising candidate for point-of-care diagnostics and personalized medicine applications. This technology opens a path to transform biomarker detection across various medical fields, offering rapid, reliable, and cost-effective diagnostic solutions. In conclusion, the presented multichannel photonic microchips signify a substantial leap forward in real-time biomarker detection, providing a highly capable platform for future research and clinical applications. T2 - SPIE Optics + Optoelectronics 2025 CY - Prague, Czech Republic DA - 07.04.2025 KW - Photonic integrated circuit KW - Ring resonator KW - Real-time detection KW - Multiplexing KW - Semiconductor KW - CMOS KW - C-reactive protein KW - CRP KW - Biomarker PY - 2025 SN - 978-1-5106-8850-6 DO - https://doi.org/10.1117/12.3056453 VL - 13527 SP - 1 EP - 6 PB - SPIE CY - Prague, Czech Republic AN - OPUS4-63478 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fünning, Tabea A1 - Peczek, Anna A1 - Kroh, Aleksandra A1 - Mai, Christian A1 - Paul, Martin A1 - Thomsen, Florian A1 - Tannenberg, Robert A1 - Schumann, Christoph A1 - Weller, Michael G. A1 - Mai, Andreas A1 - Steglich, Patrick C. ED - Lieberman, Robert A. ED - Baldini, Francesco ED - Homola, Jiri T1 - Optimization of local backside released micro-ring resonators for sensing applications using silicon photonic integrated circuits in a SOI technology N2 - Photonic micro-ring resonators (MRR) are widely studied for their high sensitivity across applications like environmental monitoring, healthcare, and chemical analysis. Their evanescent field sensing requires partially unembedded waveguides compatible with CMOS processing. Our approach uses local backside etching with an additional buried oxide (BOX) etch to release waveguides while preserving the back-end of line (BEOL) structure, enabling spatial separation of the sensing area and electronics. The BOX etch critically affects sensor performance, as waveguide surface roughness can alter MRR properties and coupling. We analyzed MRR design variations, comparing wet and dry etching techniques for their effects on optical performance across rib and strip waveguides in quasi-TE and quasi-TM modes. Wafer-level measurements show that backside-released MRR achieve high extinction ratios with slightly reduced quality factors, advancing high-sensitivity photonic sensors. T2 - SPIE Optics + Optoelectronics 2025 CY - Prague, Czech Republic DA - 23.05.2025 KW - Photonic sensors KW - Micro-ring resonator (MRR) KW - Silicon on insulator (SOI) KW - CMOS KW - Local backside etching PY - 2025 SN - 978-1-5106-8851-3 DO - https://doi.org/10.1117/12.3056481 VL - 13527 SP - 1 EP - 8 PB - SPIE CY - Bellingham, WA , USA AN - OPUS4-63585 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Steglich, Patrick A1 - Paul, Martin A1 - Fünning, Tabea A1 - Schumann, Christoph A1 - Mai, Christian A1 - Tannenberg, Robert A1 - Mai, Andreas ED - Cheben, Pavel ED - Čtyroký, Jiří ED - Molina-Fernández, Iñigo T1 - Towards monolithic integration of polymer-based electro-optical devices in silicon photonic integrated circuits using a 250nm SOI technology N2 - Photonic micro-ring resonators (MRR) are widely studied for their high sensitivity across applications like environmental monitoring, healthcare, and chemical analysis. Their evanescent field sensing requires partially unembedded waveguides compatible with CMOS processing. Our approach uses local backside etching with an additional buried oxide (BOX) etch to release waveguides while preserving the back-end of line (BEOL) structure, enabling spatial separation of the sensing area and electronics. The BOX etch critically affects sensor performance, as waveguide surface roughness can alter MRR properties and coupling. We analyzed MRR design variations, comparing wet and dry etching techniques for their effects on optical performance across rib and strip waveguides in quasi-TE and quasi-TM modes. Wafer-level measurements show that backside-released MRR achieve high extinction ratios with slightly reduced quality factors, advancing high-sensitivity photonic sensors. T2 - SPIE Optics + Optoelectronics 2025 CY - Prague, Czech Republic DA - 05.06.2025 KW - Photonic sensors KW - Micro-ring resonator (MRR) KW - Silicon on insulator (SOI) KW - CMOS KW - Local backside etching (LBE) PY - 2025 DO - https://doi.org/10.1117/12.3056280 VL - 13530 SP - 1 EP - 8 PB - SPIE CY - Bellingham, WA , USA AN - OPUS4-63587 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Paul, Martin A1 - Tannenberg, Robert A1 - Tscheuschner, Georg A1 - Ponader, Marco A1 - Weller, Michael G. T1 - Cocaine detection by a laser-induced immunofluorometric biosensor N2 - The trafficking of illegal drugs by criminal networks at borders, harbors, or airports is an increasing issue for public health as these routes ensure the main supply of illegal drugs. The prevention of drug smuggling, including the installation of scanners and other analytical devices to detect small traces of drugs within a reasonable time frame, remains a challenge. The presented immunosensor is based on a monolithic affinity column with a large excess of immobilized hapten, which traps fluorescently labeled antibodies as long as the analyte cocaine is absent. In the presence of the drug, some binding sites of the antibody will be blocked, which leads to an immediate breakthrough of the labeled protein, detectable by highly sensitive laser-induced fluorescence with the help of a Peltier-cooled complementary metal-oxide-semiconductor (CMOS) camera. Liquid handling is performed with high-precision syringe pumps and microfluidic chip-based mixing devices and flow cells. The biosensor achieved limits of detection of 7 ppt (23 pM) of cocaine with a response time of 90 s and a total assay time below 3 min. With surface wipe sampling, the biosensor was able to detect 300 pg of cocaine. This immunosensor belongs to the most sensitive and fastest detectors for cocaine and offers near-continuous analyte measurement. KW - Online detection KW - Security KW - Monoclonal antibody KW - Microfluidic mixing KW - Microfluidics KW - Lab-on-a-chip KW - Monolithic column KW - Affinity chromatography KW - Laser-induced fluorescence KW - LIF KW - ELISA KW - Wipe test KW - Low-cost PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-534487 DO - https://doi.org/10.3390/bios11090313 VL - 11 IS - 9 SP - 1 EP - 15 PB - MDPI CY - Basel AN - OPUS4-53448 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Paul, Martin A1 - Tannenberg, Robert A1 - Tscheuschner, Georg A1 - Ponader, Marco A1 - Weller, Michael G. T1 - Cocaine detection by a laser-induced immunofluorometric biosensor N2 - The trafficking of illegal drugs by criminal networks at borders, harbors, or airports is an increasing issue in public health as these routes ensure the main supply of illegal drugs. The prevention of drug smuggling, including the installation of scanners and other analytical devices to detect ultra-small traces of drugs within a reasonable time frame, remains a challenge. The presented immunosensor is based on a monolithic affinity column with a large excess of immobilized hapten, which traps fluorescently labeled antibodies as long as the analyte cocaine is absent. In the presence of the drug, some binding sites of the antibody will be blocked, which leads to an immediate breakthrough of the labeled protein, detectable by highly sensitive laser-induced fluorescence with the help of a Peltier-cooled complementary metal-oxide-semiconductor (CMOS) camera. Liquid handling is performed with high-precision syringe pumps and microfluidic chip-based mixing devices and flow cells. The biosensor achieved limits of detection of 23 pM (7 ppt) of cocaine with a response time of 90 seconds and a total assay time below 3 minutes. With surface wipe sampling, the biosensor was able to detect 300 pg of cocaine. This immunosensor belongs to the most sensitive and fastest detectors for cocaine and offers near-continuous analyte measurement. KW - Drug search KW - Customs KW - Confiscation KW - Border surveillance KW - Narcotics KW - International drug trade KW - Drug trafficking KW - Illicit drug KW - Immunosensor KW - Antibodies KW - Detection PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-529951 DO - https://doi.org/10.20944/preprints202107.0521.v1 SN - 2310-287X N1 - Geburtsname von Ponader, Marco: Wilke, M. - Birth name of Ponader, Marco: Wilke, M. SP - 1 PB - MDPI CY - Basel AN - OPUS4-52995 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tannenberg, Robert A1 - Tscheuschner, Georg A1 - Raab, Christopher A1 - Flemig, Sabine A1 - Döring, Sarah A1 - Ponader, Marco A1 - Thurmann, Melinda A1 - Paul, Martin A1 - Weller, Michael G. T1 - Simplified Sample Preparation and Lateral Flow Immunoassay for the Detection of Plant Viruses N2 - Lateral flow immunoassays (LFAs) are widely used for on-site testing; however, their use for the rapid detection of plant viruses in the field is often limited by inconvenient sample preparation. Here, we present a new sampling method and a simplified dipstick LFA format for the detection and monitoring of cowpea chlorotic mottle virus (CCMV) as a model plant pathogen. The assay employs a monoclonal mouse antibody for capture and a poly-clonal rabbit antibody conjugated to 80 nm gold nanoparticles for detection. Conventional sample and conjugate pads are omitted, allowing the test strips to be dipped directly into wells containing plant extract and antibody–gold conjugate. No plastic casing was required, which could lead to a reduction in waste. It was shown that CCMV concentrations as low as 3.5 µg/L or 350 pg per sample could be reliably detected in 15 min. Specificity tests confirmed that other plant viruses, cowpea mosaic virus (CPMV) and tobacco mosaic virus (TMV), did not produce false-positive results. In addition, we describe a new method for on-site sampling using a manual punch and a syringe equipped with a frit. This step combines grinding the sample, extraction, filtration, and reconstitution and mixing of the antibody-gold conjugate, enabling the analysis of punched leaf disks without laboratory equipment. When applied to CCMV-infected cowpea plants, the assay revealed systemic infection before visual symptoms became apparent. This work demonstrates that simplified LFAs combined with innovative sampling techniques can provide sensitive, specific, and rapid diagnostics for crop monitoring and support early intervention strategies in agriculture. N2 - Lateral-Flow-Immunoassays (LFAs) werden häufig für Vor-Ort-Tests eingesetzt; ihr Einsatz zum schnellen Nachweis von Pflanzenviren im Feld wird jedoch oft durch eine umständliche Probenvorbereitung eingeschränkt. Hier stellen wir eine neue Probenahmemethode und ein vereinfachtes Dipstick-LFA-Format zum Nachweis und zur Überwachung des Cowpea Chlorotic Mottle Virus (CCMV) als Modellpflanzenpathogen vor. Der Test verwendet einen monoklonalen Maus-Antikörper zur Bindung und einen polyklonalen Kaninchen-Antikörper, der an 80-nm-Goldnanopartikel konjugiert ist, zum Nachweis. Herkömmliche Proben- und Konjugatpads entfallen, sodass die Teststreifen direkt in Vertiefungen getaucht werden können, die Pflanzenextrakt und das Antikörper-Gold-Konjugat enthalten. Es ist keine Kunststoffhülle erforderlich, was zu einer Reduzierung des Abfallaufkommens führen könnte. Es zeigte sich, dass CCMV-Konzentrationen von nur 3,5 µg/L oder 350 pg pro Probe innerhalb von 15 Minuten zuverlässig nachgewiesen werden konnten. Spezifitätstests bestätigten, dass andere Pflanzenviren, das Cowpea Mosaic Virus (CPMV) und das Tobacco Mosaic Virus (TMV), keine falsch-positiven Ergebnisse lieferten. Darüber hinaus beschreiben wir eine neue Methode zur Probenahme vor Ort unter Verwendung eines manuellen Lochers und einer mit einer Fritte ausgestatteten Spritze. Dieser Schritt kombiniert das Zerkleinern der Probe, die Extraktion, die Filtration sowie die Rekonstitution und das Mischen des Antikörper-Gold-Konjugats und ermöglicht so die Analyse der ausgestanzten Blattscheiben ohne Laborausrüstung. Bei der Anwendung an mit CCMV infizierten Augenbohnenpflanzen zeigte der Assay eine systemische Infektion, bevor visuelle Symptome erkennbar wurden. Diese Arbeit zeigt, dass vereinfachte LFAs in Kombination mit innovativen Probenahmetechniken eine sensitive, spezifische und schnelle Diagnostik für die Pflanzenüberwachung bieten und Strategien zur frühzeitigen Intervention in der Landwirtschaft unterstützen können. KW - Point-of-care diagnostics KW - Dipstick immunoassay KW - Pre-symptomatic detection KW - Precision agriculture KW - Integrated pest management KW - Crop health monitoring PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-657039 DO - https://doi.org/10.3390/bios16020100 SN - 2079-6374 VL - 16 IS - 2 SP - 1 EP - 16 PB - MDPI AG CY - Basle, Switzerland AN - OPUS4-65703 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -