TY - JOUR A1 - Schlegel, Moritz-Caspar A1 - Müller, Urs A1 - Panne, Ulrich A1 - Emmerling, Franziska T1 - Deciphering the sulfate attack of cementitious materials by high-resolution micro-x-ray diffraction N2 - The durability of cementitious materials depends, among others, on their resistance against chemical attack during the service life of a building. Here, we present an approach to analyze changes in the phase composition due to chemical attack in the form of sulfate ingress within the microstructure. Micro-X-ray (µX-ray) diffraction using synchrotron radiation in Debye–Scherrer (transmission) geometry allowed a spatial resolution of 10 µm. Phase transformations in the wake of damaging processes were observed in a detailed high-resolution imaging study. In comparison, samples containing supplementary cementitious materials were investigated and used to reconstruct the influence of different degeneration processes in detail. Additionally, reaction fronts within the bulk were localized by micro-X-ray fluorescence analysis. The experimental setup provided the possibility for analyzing the phase assemblage of a given sample without destroying the microstructure. The specimens for phase analysis are thick sections of the primary material and can be used for further microscopic analysis of the microstructure and microchemistry, e.g., scanning electron microscopy–energy-dispersive X-ray spectroscopy (SEM–EDX) or Raman spectroscopy. PY - 2011 DO - https://doi.org/10.1021/ac200181g SN - 0003-2700 SN - 1520-6882 VL - 83 IS - 10 SP - 3744 EP - 3749 PB - American Chemical Society CY - Washington, DC AN - OPUS4-23669 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dutschke, Andreas A1 - Lohrer, Christian A1 - Kurth, Lutz A1 - Seeger, Stefan A1 - Barthel, Mathias A1 - Panne, Ulrich T1 - Aerosol emissions from outdoor firework displays N2 - The results of investigations on the emission of particulate matter from three outdoor firework displays are presented. During these events, possibly harmful and toxic aerosol emissions were measured. Aerosols in the size range from 30 to 450 nm were detected. The maxima in the observed particle size distribution were between 80 and 175 nm, and the highest value determined was ~1.3 · 106 particles per cm³, while the highest mass concentration was approximately 1.8 mg m–3. The time-averaged particle mass concentration did, however, not exceed 0.7 mg m–3 (over 15 min). KW - Firework display KW - Particle size range KW - Particulate matter KW - Threshold values PY - 2011 DO - https://doi.org/10.1002/ceat.201100080 SN - 0930-7516 SN - 1521-4125 VL - 34 IS - 12 SP - 2044 EP - 2050 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-24929 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Leiterer, Jork A1 - Panne, Ulrich A1 - Thünemann, Andreas A1 - Weidner, Steffen T1 - Container-less polymerization in acoustically levitated droplets: an analytical study by GPC and MALDI-TOF mass spectrometry N2 - Molecular masses and end groups of polystyrene (PS) formed in a novel container-less polymerization strategy, based on levitated droplets in an acoustic trap, were determined by Gel Permeation Chromatography (GPC) and Matrix-assisted Laser Desorption/Ionization Time of Flight Mass spectrometry (MALDI-TOF MS). KW - Ultraschallfalle KW - MALDI Massenspektrometrie KW - Polymerisation PY - 2011 DO - https://doi.org/10.1039/c0ay00390e SN - 1759-9660 SN - 1759-9679 VL - 3 IS - 1 SP - 70 EP - 73 PB - RSC Publ. CY - Cambridge AN - OPUS4-23655 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schlegel, Moritz-Caspar A1 - Müller, Urs A1 - Panne, Ulrich A1 - Emmerling, Franziska A1 - Meng, Birgit ED - Rogge, A. ED - Meng, B. T1 - Neue Wege in der Zementanalytik - Hochaufgelöste in-situ Sy-XRD T2 - 52. DAfStb-Forschungskolloquium CY - Berlin, Deutschland DA - 2011-11-07 PY - 2011 SN - 978-3-9814281-0-0 SP - 18 EP - 24 PB - BAM Bundesanstalt für Materialforschung und -prüfung CY - Berlin AN - OPUS4-25197 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kühn, Andreas A1 - Scharf, Oliver A1 - Ordavo, I. A1 - Riesemeier, Heinrich A1 - Reinholz, Uwe A1 - Radtke, Martin A1 - Berger, Achim A1 - Ostermann, Markus A1 - Panne, Ulrich T1 - Pushing the limits for fast spatially resolved elemental distribution patterns N2 - A new setup for fast spatially resolved measurements of elemental trace amounts under total reflection conditions using a new colour X-ray camera is described. Samples prepared on conventional total reflection X-ray fluorescence (TXRF) reflectors were measured at BESSY II synchrotron. A spatial resolution of 50 × 50 µm² was obtained, while the required time for the investigation of a 10 × 10 mm² sample is 30 seconds. The set-up is up to 350 times faster than conventional X-ray fluorescence systems for elemental traces. The major components of the X-ray camera are polycapillary optics and a pn-CCD chip with an active area of 13 × 13 mm². This area is divided into 264 × 264 pixels of 48 × 48 µm². A full X-ray spectrum with a resolution of 152 eV @ 5.9 keV and a chip temperature of 246 K is recorded for each pixel. The chip has a read-out rate of 400 Hz. PY - 2011 DO - https://doi.org/10.1039/c1ja10069f SN - 0267-9477 SN - 1364-5544 VL - 26 SP - 1986 EP - 1989 PB - Royal Society of Chemistry CY - London AN - OPUS4-24386 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -