TY - JOUR A1 - Höhse, Marek A1 - Gornushkin, Igor B. A1 - Merk, Sven A1 - Panne, Ulrich T1 - Assessment of suitability of diode pumped solid state lasers for laser induced breakdown and Raman spectroscopy N2 - The potential of a diode pumped solid state (DPSS) laser for laser induced breakdown spectroscopy (LIBS) and Raman spectroscopy was investigated. The DPSS laser operating at repetition rates of 1 Hz–200 kHz, pulse energy of ~1 mJ, and pulse duration of ~20 ns was added to a conventional LIBS system equipped with the flashlamp-pumped Nd:YAG laser (10 Hz, 400 mJ, 6 ns) to directly compare the two laser systems. Despite the lower mass ablated per laser pulse (~several nanograms) and a weaker plasma, the total mass ablated per measurement interval (~1 s) and total emission signal were significantly higher than those obtained with the flashlamp pumped Nd:YAG laser. This resulted in the improved signal-to-noise ratio and better limits of detection (LOD). The best LODs were obtained for Cu, Cr and Ni in ultrapure standard iron samples, 0.7 ppm, 1 ppm and 5 ppm, correspondingly. The plasma from the DPSS laser was characterized in terms of its radiative properties, temperature, and shockwave propagation speed. The suitability of this laser for LIBS-Raman was demonstrated by mapping the elemental and molecular composition of a mineral sample. The results strongly imply that DPSS lasers are the promising source for LIBS, Raman, or combined LIBS-Raman spectroscopy. PY - 2011 DO - https://doi.org/10.1039/c0ja00038h SN - 0267-9477 SN - 1364-5544 VL - 26 IS - 2 SP - 414 EP - 424 PB - Royal Society of Chemistry CY - London AN - OPUS4-22943 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dutschke, Andreas A1 - Lohrer, Christian A1 - Kurth, Lutz A1 - Seeger, Stefan A1 - Barthel, Mathias A1 - Panne, Ulrich T1 - Aerosol emissions from outdoor firework displays N2 - The results of investigations on the emission of particulate matter from three outdoor firework displays are presented. During these events, possibly harmful and toxic aerosol emissions were measured. Aerosols in the size range from 30 to 450 nm were detected. The maxima in the observed particle size distribution were between 80 and 175 nm, and the highest value determined was ~1.3 · 106 particles per cm³, while the highest mass concentration was approximately 1.8 mg m–3. The time-averaged particle mass concentration did, however, not exceed 0.7 mg m–3 (over 15 min). KW - Firework display KW - Particle size range KW - Particulate matter KW - Threshold values PY - 2011 DO - https://doi.org/10.1002/ceat.201100080 SN - 0930-7516 SN - 1521-4125 VL - 34 IS - 12 SP - 2044 EP - 2050 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-24929 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gornushkin, Igor B. A1 - Shabanov, Sergej V. A1 - Panne, Ulrich T1 - Abel inversion applied to a transient laser induced plasma: implications from plasma modeling N2 - We test the effects of non-uniformity, non-transparency, and non-stationarity of a laser-induced plasma on the results obtained by the Abel inversion method. The method is commonly used for obtaining spatially resolved emissivity of axially symmetric non-homogeneous radiating objects. Besides the axial symmetry, the plasma is assumed to be optically thin. As the method addresses a certain plasma state, the plasma is required to be stationary during measurements. It is difficult to satisfy the aforementioned conditions for transient laser induced plasmas. As such the plasmas are not stationary; they have steep gradients of thermodynamic parameters that rapidly vary during the plasma evolution. Therefore, any conclusion based on time-integrated measurements and the corresponding data processing should account for these effects. In this work, we use the collision-dominated plasma model to generate time- and spatially resolved synthetic spectra. The spectra are processed by executing the Abel inversion using two numerical algorithms. Thus obtained spatially resolved plasma parameters (emissivity, temperature, and number density) are compared with the exact parameters used to set up the model. In doing so, the accuracy of the Abel inversion method is assessed. Special attention is paid to the dynamic aspect of the expanding plasma and possible errors which result from time-integrated measurements. PY - 2011 DO - https://doi.org/10.1039/c1ja10044k SN - 0267-9477 SN - 1364-5544 VL - 26 IS - 7 SP - 1457 EP - 1465 PB - Royal Society of Chemistry CY - London AN - OPUS4-25824 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rackwitz, Vanessa A1 - Procop, M. A1 - Bjeoumikhova, S. A1 - Panne, Ulrich A1 - Hodoroaba, Vasile-Dan T1 - A routine procedure for the characterisation of polycapillary X-ray semi-lenses in prallelising mode with SEM/EDS N2 - The accurate knowledge of the properties of polycapillary X-ray semi-lenses has a significant influence on the quantitative results in a widespread field of applications involving microfocus X-ray beams. A routine procedure for the characterisation of a polycapillary X-ray semi-lens with a scanning electron microscope (SEM) having attached an energy dispersive spectrometer (EDS) is presented in this paper. A key issue of the procedure consists of fitting the semi-lens in front of the EDS for spectra acquisition. Relevant semi-lens parameters such as focal distance, full width at half maximum (FWHM) of the acceptance area, and transmission are determined in parallelising mode of the semi-lens. Special attention has been paid to the calculation of the transmission. KW - Polycapillary X-ray optics KW - Semi-lens KW - Parallelising mode KW - SEM KW - EDS KW - Acceptance area KW - FWHM KW - Transmission KW - Focal distance KW - XRF PY - 2011 DO - https://doi.org/10.1039/c0ja00135j SN - 0267-9477 SN - 1364-5544 VL - 26 IS - 3 SP - 499 EP - 504 PB - Royal Society of Chemistry CY - London AN - OPUS4-23555 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Walter, Astrid A1 - Panne, Ulrich A1 - Weller, Michael G. T1 - A novel immunoreagent for the specific and sensitive detection of the explosive triacetone triperoxide (TATP) N2 - Triacetone triperoxide (TATP) is a primary explosive, which was used in various terrorist attacks in the past. For the development of biosensors, immunochemical µ-TAS, electronic noses, immunological test kits, or test strips, the availability of antibodies of high quality is crucial. Recently, we presented the successful immunization of mice, based on the design, synthesis, and conjugation of a novel TATP derivative. Here, the long-term immunization of rabbits is shown, which resulted in antibodies of extreme selectivity and more than 1,000 times better affinity in relation to the antibodies from mice. Detection limits below 10 ng L-1 (water) were achieved. The working range covers more than four decades, calculated from a precision profile. The cross-reactivity tests revealed an extraordinary selectivity of the antibodies—not a single compound could be identified as a relevant cross-reactant. The presented immunoreagent might be a major step for the development of highly sensitive and selective TATP detectors particularly for security applications. KW - Organic peroxides KW - Terrorism KW - Biosensor development PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-240291 UR - http://www.mdpi.com/2079-6374/1/3/93 DO - https://doi.org/10.3390/bios1030093 SN - 2079-6374 VL - 1 IS - 3 SP - 93 EP - 106 PB - MDPI CY - Basel AN - OPUS4-24029 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -