TY - JOUR A1 - Herwig, Nadine A1 - Stephan, Kristin A1 - Panne, Ulrich A1 - Pritzkow, Wolfgang A1 - Vogl, Jochen T1 - Multi-element screening in milk and feed by SF-ICP-MS N2 - In this study, an analytical procedure for multi-element screening of 40 elements in milk and feed samples was developed. Three different digestion and two different calibration methods were tested for the best suitability. The analytical procedure for the quantification of minor and trace elements is based on sector field ICP-MS (SF-ICP-MS). The method validation revealed good agreement between the determined elemental mass fractions and the certified values of two milk and three feed reference materials. Milk samples of dairy cows at different feeding regimes were collected from two different farms. The results of our study showed significant differences of nine elemental mass fractions (Li, P, Mn, Co, Cu, Rb, Sr, Br, I) between milk from the two locations. Further, a correlation between the elemental mass fractions of milk and the ingested feed and water was observed. KW - Multi-element screening KW - SF-ICP-MS KW - Dairy cows KW - Milk KW - Feed KW - Water PY - 2011 DO - https://doi.org/10.1016/j.foodchem.2010.07.050 SN - 0308-8146 VL - 124 IS - 3 SP - 1223 EP - 1230 PB - Elsevier Ltd. CY - Amsterdam [u.a.] ; Jena AN - OPUS4-22042 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Panne, Ulrich T1 - Mit Sicherheit vorn - Analytische Chemie im Dienste der technischen Sicherheit und Materialforschung T2 - Institutskolloquium des GKSS Teltow CY - Teltow, Germany DA - 2010-05-27 PY - 2010 AN - OPUS4-21537 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Panne, Ulrich T1 - Analytische Chemie - Wissenschaft oder Dienstmagd T2 - 6. ASAC Junganalytikertreffen CY - Vienna, Austria DA - 2010-06-11 PY - 2010 AN - OPUS4-21538 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Panne, Ulrich T1 - Spectrochemical Analysis: Tools and Toys!? T2 - eingel. Vortrag CY - Graz, Austria DA - 2010-03-15 PY - 2010 AN - OPUS4-21536 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gopala, Anil A1 - Zellmann, M. A1 - Kipphardt, Heinrich A1 - Jakubowski, Norbert A1 - Panne, Ulrich T1 - Mass spectrometric study of the impurity profile in Zn during reduction-distillation of ZnO with activated and inactivated Al N2 - In this work, we report on the application of hyphenated gas source mass spectrometry to study and understand the mechanism of the reduction-distillation of ZnO using Al powder as reductant in its activated and inactivated form. The experiments revealed that the purity of the Zn metal produced were superior using activated Al with respect to inactivated Al, i.e., m5N8 (99.9998% metallic based) versus m5N3. The achieved purity levels of Zn and the absence of high volatile Cd, Mg, and Sb impurities in the gas phase and the material collected were explained with respect to the impurity elements free-energy values, vapor pressure data, and an observed scavenging effect of the Ta crucible, which was supported by the on-line observed mass spectrometric profiles of the residual gas. PY - 2010 DO - https://doi.org/10.1016/j.jasms.2010.04.009 SN - 1044-0305 VL - 21 IS - 9 SP - 1620 EP - 1623 PB - Elsevier CY - New York, NY AN - OPUS4-21910 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gopala, Anil A1 - Jakubowski, Norbert A1 - Panne, Ulrich A1 - Kipphardt, Heinrich T1 - Real time monitoring of chemical transformations during catalytic reduction using gas source mass spectrometry: carbon/zinc carbonate hydroxide N2 - We report herein the utilization of a vacuum reduction distillation system (VRDS) coupled with mass spectrometry (MS) to characterize chemical transformations in thermal analysis. The system initially designed to monitor metal purification by distillation is applied for the first time to the catalytic reaction of in situ formed nickel oxide during the carbothermic reduction of zinc oxide. PY - 2010 DO - https://doi.org/10.1039/c004179c SN - 0267-9477 SN - 1364-5544 VL - 25 SP - 1378 EP - 1380 PB - Royal Society of Chemistry CY - London AN - OPUS4-21911 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Panne, Ulrich T1 - Spectrochemical Analysis: Tools and Toys!? T2 - GDCH-Vortrag, Wintersemester, Universtät Essen-Duisburg CY - Essen, Germany DA - 2011-02-02 PY - 2011 AN - OPUS4-22140 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nietzold, Carolin A1 - Dietrich, Paul A1 - Lippitz, Andreas A1 - Panne, Ulrich A1 - Unger, Wolfgang T1 - Cyclodextrin – ferrocene host – guest complexes on silicon oxide surfaces N2 - Research on carbohydrate based interactions with proteins, nucleic acids or antibodies has gained increased interest in the last years especially in clinical diagnosis or drug development. The efficiency of diagnostic interfaces depends upon the number of probe molecules, e.g. carbohydrates. The control of surface parameters as density and distribution of immobilized carbohydrates is essential for a reliable interaction with protein analytes. A controlled production of biomolecular interfaces can be reached by a stepwise quality control during buildup of these biointerfaces. Here, ß-amino-cyclodextrin molecules were attached to amine-reactive silicon oxide surfaces via click chemistry to construct a model biosensor surface. The amount of surface bound carbohydrates was determined indirectly after chemical derivatization with 4-(trifluoromethyl)-benzylamine (TFMBA). Moreover, these surfaces were used to form host-guest complexes of ferrocene (guest) and β-cyclodextrin (host) moieties to mimic the target binding (sensing) of the model biosensor. Surface chemical analysis of all steps during biosensor construction was performed using X-ray photoelectron spectroscopy (XPS) and near-edge X-ray absorption fine structure spectroscopy (NEXAFS). Our approach widens the possibilities to generate switchable surfaces based on ß-Cyclodextrin surfaces for biosensor applications. KW - ß-amino-cyclodextrin KW - Ferrocene KW - Guest complexe KW - XPS KW - NEXAFS PY - 2016 DO - https://doi.org/10.1002/sia.5958 SN - 0142-2421 SN - 1096-9918 VL - 48 IS - 7 SP - 606 EP - 610 PB - Wiley AN - OPUS4-36856 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gornushkin, Igor B. A1 - Shabanov, Sergej V. A1 - Merk, Sven A1 - Tognoni, E. A1 - Panne, Ulrich T1 - Effects of non-uniformity of laser induced plasma on plasma temperature and concentrations determined by the Boltzmann plot method: implications from plasma modeling PY - 2010 DO - https://doi.org/10.1039/C0JA00016G SN - 0267-9477 SN - 1364-5544 VL - 25 SP - 1643 EP - 1653 PB - Royal Society of Chemistry CY - London AN - OPUS4-22942 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Höhse, Marek A1 - Gornushkin, Igor B. A1 - Merk, Sven A1 - Panne, Ulrich T1 - Assessment of suitability of diode pumped solid state lasers for laser induced breakdown and Raman spectroscopy N2 - The potential of a diode pumped solid state (DPSS) laser for laser induced breakdown spectroscopy (LIBS) and Raman spectroscopy was investigated. The DPSS laser operating at repetition rates of 1 Hz–200 kHz, pulse energy of ~1 mJ, and pulse duration of ~20 ns was added to a conventional LIBS system equipped with the flashlamp-pumped Nd:YAG laser (10 Hz, 400 mJ, 6 ns) to directly compare the two laser systems. Despite the lower mass ablated per laser pulse (~several nanograms) and a weaker plasma, the total mass ablated per measurement interval (~1 s) and total emission signal were significantly higher than those obtained with the flashlamp pumped Nd:YAG laser. This resulted in the improved signal-to-noise ratio and better limits of detection (LOD). The best LODs were obtained for Cu, Cr and Ni in ultrapure standard iron samples, 0.7 ppm, 1 ppm and 5 ppm, correspondingly. The plasma from the DPSS laser was characterized in terms of its radiative properties, temperature, and shockwave propagation speed. The suitability of this laser for LIBS-Raman was demonstrated by mapping the elemental and molecular composition of a mineral sample. The results strongly imply that DPSS lasers are the promising source for LIBS, Raman, or combined LIBS-Raman spectroscopy. PY - 2011 DO - https://doi.org/10.1039/c0ja00038h SN - 0267-9477 SN - 1364-5544 VL - 26 IS - 2 SP - 414 EP - 424 PB - Royal Society of Chemistry CY - London AN - OPUS4-22943 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schulte, Franziska A1 - Panne, Ulrich A1 - Kneipp, Janina T1 - Molecular changes during pollen germination can be monitored by Raman microspectroscopy N2 - The processes associated with pollen germination were studied in vitro for two tree species, Salix caprea and Fraxinus excelsior under different nutrient conditions. The results provide evidence of changes in chemical composition of the pollen grains during germination. From the comparison of spectra of the pollen grain body and the growing pollen tube, it can be concluded that there are major chemical differences between these two morphological units. Comparison of germinated and ungerminated pollen grains reveals alterations in the metabolism. Composition of the germinating pollen grain and its morphological units depends on the plant species, but also on the nutrient conditions. The results suggest species-specific utilization of metabolite storage, and potential alterations of the pollen outer coat. Furthermore, discharge of molecules into the nutrient medium may depend on the nutrient conditions in the germination experiments. This has implications for further experiments on dynamic processes in pollen and related plant materials. KW - Pollen germination KW - Raman microspectroscopy KW - Imaging KW - Coumaric acid KW - Pollen tube KW - Sporopollenin PY - 2010 DO - https://doi.org/10.1002/jbio.201000031 SN - 1864-063X VL - 3 IS - 8-9 SP - 542 EP - 547 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-23211 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Panne, Ulrich A1 - Bremser, Wolfram T1 - Considerations with regard to the calculation of key comparison reference values and uncertainties N2 - Much has been published over the last years on finding the best (consensus) reference value for a given set of key comparison data, and a suite of approaches proposed. In this paper, several aspects are highlighted which should be taken into account when deciding on key comparison strategies, protocols, and the best approach to reliable key comparison reference value and uncertainty. Some of these aspects are briefly discussed. The paper is intended to intensify discussions, and any comments and opinions are welcome. KW - Key comparison KW - Reference value KW - Reference value uncertainty KW - Equivalence PY - 2009 DO - https://doi.org/10.1007/s00769-009-0515-x SN - 0949-1775 SN - 1432-0517 VL - 14 IS - 5 SP - 281 EP - 287 PB - Springer CY - Berlin AN - OPUS4-19460 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Dutschke, Andreas A1 - Lohrer, Christian A1 - Seeger, Stefan A1 - Kurth, Lutz A1 - Schmidt, Martin A1 - Kaiser, Michael A1 - Stattaus, Kim A1 - Panne, Ulrich T1 - Determination of reaction products during a large firework display in Germany T2 - 11th International symposium on fireworks CY - Puerto Vallarta, México DA - 2009-04-20 KW - Firework display KW - Reaction products KW - Particles KW - Sound pressure PY - 2009 SN - 978-0-9734123-8-3 SP - 50 EP - 63 AN - OPUS4-19383 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gopala, Anil A1 - Kipphardt, Heinrich A1 - Matschat, Ralf A1 - Panne, Ulrich T1 - Mass spectrometry insight of the process mechanism during the vacuum distillation of zinc N2 - Detection and monitoring of volatile elements released during the preparation of ultra high purity zinc by vacuum distillation (VD) is reported using online quadrupole gas source mass spectrometry (QMS). The theoretically calculated vapour pressures (pv) for the volatile impurity elements using Dushman constants and the practically observed mass spectra were found to be consistent (S. Dushman and J. M. Lafferty, Scienific Foundations of Vacuum Technique, 2nd ed., Wiley, New York, 1962). This is the first time that the potential ability of an online mass spectrometer was used for monitoring and understanding the process mechanism during the purification of metals (Zn) using VD. We here also illustrate our findings with the results from high resolution glow discharge mass spectrometer (HR-GDMS) analysis before and after the purification of Zn. PY - 2009 DO - https://doi.org/10.1039/b904133h SN - 0267-9477 SN - 1364-5544 VL - 24 SP - 887 EP - 890 PB - Royal Society of Chemistry CY - London AN - OPUS4-19595 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Panne, Ulrich T1 - Standardization in LIBS Measurement T2 - EMSLIBS CY - Rome, Italy DA - 2009-09-28 PY - 2009 AN - OPUS4-19839 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Panne, Ulrich T1 - Analytik City Adlershof T2 - IGAFA-Besuch der Siemens-Delegation CY - 12489 Berlin, Rudower Chaussee 11 DA - 2009-12-04 PY - 2009 AN - OPUS4-20050 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schulte, Franziska A1 - Mäder, J. A1 - Kroh, L.W. A1 - Panne, Ulrich A1 - Kneipp, Janina T1 - Characterization of pollen carotenoids with in situ and high-performance thin-layer chromatography supported resonant Raman spectroscopy N2 - Raman signatures of the carotenoid component are studied in individual pollen grains from different species of trees. The information is obtained as differences in the strong pre-resonant Raman spectra measured before and after photodepletion of the carotenoid molecules. The results provide the first in situ evidence of interspecies differences in pollen carotenoid content, structure, and/or assembly between plant species without prior purification. The analysis of carotenoids in situ is confirmed by high-performance thin-layer chromatography (HPTLC)-supported resonance Raman data measured directly on the HPTLC plates after separation of carotenoids in pollen extracts. Utilization of the in situ, extraction-free procedure in carotenoid analysis will improve sensitivity and structural selectivity and provides insight into carotenoid structure and composition in single pollen grains. PY - 2009 DO - https://doi.org/10.1021/ac901389p SN - 0003-2700 SN - 1520-6882 VL - 81 IS - 20 SP - 8426 EP - 8433 PB - American Chemical Society CY - Washington, DC AN - OPUS4-20260 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dutschke, Andreas A1 - Seeger, Stefan A1 - Kurth, Lutz A1 - Panne, Ulrich A1 - Lohrer, Christian T1 - Emissions of reaction products and sound from outdoor and indoor firework displays N2 - This work presents results of investigations towards the emission of chemical reaction products and sound pressure during an outdoor and an indoor firework display. Potentially harmful and toxic gases, and aerosols, were measured as well as sound pressures. Aerosols were measured with a Differential Mobility Analyzer (DMA) as well as a Laser Particle Counter. The focus was on particles with diameters between 11 nm and 20 µm. A transportable Fourier Transform Infrared (FTIR) spectroscopy detector registered the concentrations of emitted reaction gases, simultaneously. During the outdoor firework display, peak particle concentrations of >550000 particles cm-3, equivalent to a mass concentration of approximately 3.95 mg m-3, were detected, revealing a concentration maximum at approximately 175 nm particle diameter. The time-averaged particle mass concentration did not exceed 1.58 mg m-3 over 15 minutes. Due to the large distances (110 m) to the firing points, no significant harmful or toxic gas concentrations were measured during the entire firework display. In contrast, concentrations of sulphur dioxide (SO2) rose after an indoor firework display in a large event hall. On two days, more than 23000 particles cm-3 (which equates to a mass concentration of approximately 0.41 mg m-3) were detected when the hall ventilation was turned off, and more than 11000 particles cm-3 (which equates to a mass concentration of approximately 1.18 mg m-3) when the hall ventilation was activated. Concentration maxima appeared at approximately 300 nm particle diameter. The time-averaged particle concentrations in this case did not exceed 0.56 mg m-3 (over 15 minutes). KW - Pyrotechnic articles KW - Aerosols KW - Combustion gases PY - 2009 SN - 1082-3999 IS - 28 SP - 78 EP - 93 CY - Whitewater, Colo. AN - OPUS4-20796 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Höhse, Marek A1 - Mory, D. A1 - Florek, S. A1 - Weritz, Friederike A1 - Gornushkin, Igor B. A1 - Panne, Ulrich T1 - A combined laser-induced breakdown and Raman spectroscopy Echelle system for elemental and molecular microanalysis N2 - Raman and laser-induced breakdown spectroscopy is integrated into a single system for molecular and elemental microanalyses. Both analyses are performed on the same ~ 0.002 mm² sample spot allowing the assessment of sample heterogeneity on a micrometric scale through mapping and scanning. The core of the spectrometer system is a novel high resolution dual arm Echelle spectrograph utilized for both techniques. In contrast to scanning Raman spectroscopy systems, the Echelle-Raman spectrograph provides a high resolution spectrum in a broad spectral range of 200-6000 cm- 1 without moving the dispersive element. The system displays comparable or better sensitivity and spectral resolution in comparison to a state-of-the-art scanning Raman microscope and allows short analysis times for both Raman and laser induced breakdown spectroscopy. The laser-induced breakdown spectroscopy performance of the system is characterized by ppm detection limits, high spectral resolving power (15,000), and broad spectral range (290-945 nm). The capability of the system is demonstrated with the mapping of heterogeneous mineral samples and layer by layer analysis of pigments revealing the advantages of combining the techniques in a single unified set-up. KW - LIBS KW - Raman KW - Echelle KW - Laser-induced breakdown spectroscopy KW - Hyphenated technique PY - 2009 DO - https://doi.org/10.1016/j.sab.2009.09.004 SN - 0584-8547 SN - 0038-6987 VL - 64 IS - 11-12 SP - 1219 EP - 1227 PB - Elsevier CY - Amsterdam AN - OPUS4-20493 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gornushkin, Igor B. A1 - Panne, Ulrich A1 - Winefordner, J. D. T1 - Linear correlation for identification of materials by laser induced breakdown spectroscopy: Improvement via spectral filtering and masking N2 - The purpose of this work is to improve the performance of a linear correlation method used for material identification in laser induced breakdown spectroscopy. The improved correlation procedure is proposed based on the selection and use of only essential spectral information and ignoring empty spectral fragments. The method is tested on glass samples of forensic interest. The 100% identification capability of the new method is demonstrated in contrast to the traditional approach where the identification rate falls below 100% for many samples. KW - Correlation analysis KW - Linear correlation KW - Material identification KW - Laser induced plasma KW - LIBS PY - 2009 DO - https://doi.org/10.1016/j.sab.2009.07.038 SN - 0584-8547 SN - 0038-6987 VL - 64 IS - 10 SP - 1040 EP - 1047 PB - Elsevier CY - Amsterdam AN - OPUS4-20621 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kipphardt, Heinrich A1 - Matschat, Ralf A1 - Panne, Ulrich T1 - Development of SI traceable standards for element determination N2 - In Germany a system of primary amount of substance standards for elemental analysis is being developed, which forms the material´s basis for the National Standards for element determination. The metrological concept and technical approach is briefly described. The objective of traceability in chemistry, in this case for elemental determination, is illustrated on the example of copper. KW - Copper KW - Element determination KW - Metrology KW - Primary standards KW - Traceability PY - 2009 DO - https://doi.org/10.2533/chimia.2009.637 SN - 0009-4293 VL - 63 IS - 10 SP - 637 EP - 639 PB - Schweizerische Chemische Gesellschaft CY - Basel AN - OPUS4-20727 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -