TY - JOUR A1 - Gusarova, Tamara A1 - Hofmann, T. A1 - Kipphardt, Heinrich A1 - Venzago, C. A1 - Matschat, Ralf A1 - Panne, Ulrich T1 - Comparison of different calibration strategies for the analysis of zinc and other pure metals by using the GD-MS instruments VG 9000 and element GD JF - Journal of analytical atomic spectrometry N2 - Synthetic pressed metal powder standards doped with standard solutions were used for the calibration of both commercially available high resolution GD-MS instruments Element GD and VG 9000 for zinc matrix. Different quantification procedures (IBR, Standard RSF, matrix matched RSF from the calibration with CRMs and use of doped synthetic standards) are compared using zinc matrix as an example, whereas the calibration with doped pellets turned out to be the best quantification technique for high-purity materials. The applicability of the Standard RSF concept is scrutinised. In this context, RSF values for several Matrices (Co, Cu, Fe, In and Zn) are reported additionally. PY - 2010 DO - https://doi.org/10.1039/b921649a SN - 0267-9477 SN - 1364-5544 VL - 25 SP - 314 EP - 321 PB - Royal Society of Chemistry CY - London AN - OPUS4-22376 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gusarova, Tamara A1 - Hodoroaba, Vasile-Dan A1 - Matschat, Ralf A1 - Kipphardt, Heinrich A1 - Panne, Ulrich T1 - Exploitation of the hollow cathode effect for sensitivity enhancement of Grimm-type DC glow discharge optical emission spectroscopy JF - Journal of analytical atomic spectrometry N2 - The hollow cathode (HC) effect was investigated in non-cooled 15 mm deep drilled flat metallic analytical samples that were easy to prepare. The deep cavity used ("complete HC" in contrast to "recessed HC" with 2-3 mm deep cavity) intensified the HC effect notably and therefore distinctly improved the detection power of the common GD-OES with planar cathodes. A signal enhancement of up to a factor of 150, not reported earlier, in comparison with flat conventional samples was achieved. A better separation of the analytical lines from spectral interferences was observed when the HC assembly was applied. Additionally, an effect of strongly enhanced intensities of atomic lines and somewhat decreased intensities of ionic lines was detected in the case of HC in comparison to usual planar cathodes. The investigations were carried out with samples of copper, steel and zinc matrices using both the same and individually optimised glow discharge (GD) electrical parameters. KW - Hollow cathode KW - Grimm type glow discharge KW - Emission spectroscopy KW - GD-OES KW - Sensitivity PY - 2009 DO - https://doi.org/10.1039/b814977a SN - 0267-9477 SN - 1364-5544 VL - 24 SP - 680 EP - 684 PB - Royal Society of Chemistry CY - London AN - OPUS4-19600 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Traub, Heike A1 - Wälle, M. A1 - Koch, J. A1 - Panne, Ulrich A1 - Matschat, Ralf A1 - Kipphardt, Heinrich A1 - Günther, D. T1 - Evaluation of different calibration strategies for the analysis of pure copper and zinc samples using femtosecond laser ablation ICP-MS JF - Analytical and bioanalytical chemistry N2 - Solution-doped metal powder pellets as well as aspirated liquids were used as calibration samples to analyze pure copper and zinc certified reference materials (CRMs) by femtosecond laser ablation ICP-MS. It was demonstrated that calibration by copper pellets resulted in relative deviations up to 20%, whereas fs-LA-ICP-MS among copper-based CRMs led to inaccuracies in the same range unless nominal mass fractions were chosen to be <3 mg/kg. Calibration by zinc pellets generally provided better accuracy. Depending on the analyte considered, deviations below 10% were obtained even for mass fractions close to the limit of quantification. Our data, therefore, indicate solution-doped metal powder pellets to be suitable as calibration samples for fs-LA-ICP-MS of metals. Furthermore, the utilization of liquid standards for calibration was found to result in stronger deviations of up to 50% for both copper and zinc samples which, in addition, turned out to be dependent on the plasma conditions. KW - Laser ablation KW - ICP-MS KW - Calibration KW - Copper KW - Zinc KW - Metal PY - 2009 DO - https://doi.org/10.1007/s00216-009-3061-9 SN - 1618-2642 SN - 1618-2650 VL - 395 IS - 5 SP - 1471 EP - 1480 PB - Springer CY - Berlin AN - OPUS4-20402 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wienold, Julia A1 - Traub, Heike A1 - Lange, Britta A1 - Giray, Thorsten A1 - Recknagel, Sebastian A1 - Kipphardt, Heinrich A1 - Matschat, Ralf A1 - Panne, Ulrich T1 - Elemental analysis of copper and magnesium alloy samples using IR-laser ablation in comparison with spark and glow discharge methods JF - Journal of analytical atomic spectrometry N2 - Three methods for direct solid sampling of bulk material namely IR laser ablation, glow discharge and spark OES, were compared with respect to analytical figures of merit obtained for elemental analysis with atomic spectrometry. Matrices investigated were copper, pressed doped copper powder, and magnesium alloys. For the vast majority of analytes, statistical equivalence regarding precision (usually ≤ 5%) and the performance of the calibrations between the compared methods was demonstrated. KW - LA-ICP-MS KW - GD-MS KW - Spark-OES KW - LA-ICP-OES KW - Copper KW - Magnesium PY - 2009 DO - https://doi.org/10.1039/b903251g SN - 0267-9477 SN - 1364-5544 VL - 24 SP - 1570 EP - 1574 PB - Royal Society of Chemistry CY - London AN - OPUS4-20257 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gopala, Anil A1 - Kipphardt, Heinrich A1 - Matschat, Ralf A1 - Panne, Ulrich T1 - Mass spectrometry insight of the process mechanism during the vacuum distillation of zinc JF - Journal of analytical atomic spectrometry N2 - Detection and monitoring of volatile elements released during the preparation of ultra high purity zinc by vacuum distillation (VD) is reported using online quadrupole gas source mass spectrometry (QMS). The theoretically calculated vapour pressures (pv) for the volatile impurity elements using Dushman constants and the practically observed mass spectra were found to be consistent (S. Dushman and J. M. Lafferty, Scienific Foundations of Vacuum Technique, 2nd ed., Wiley, New York, 1962). This is the first time that the potential ability of an online mass spectrometer was used for monitoring and understanding the process mechanism during the purification of metals (Zn) using VD. We here also illustrate our findings with the results from high resolution glow discharge mass spectrometer (HR-GDMS) analysis before and after the purification of Zn. PY - 2009 DO - https://doi.org/10.1039/b904133h SN - 0267-9477 SN - 1364-5544 VL - 24 SP - 887 EP - 890 PB - Royal Society of Chemistry CY - London AN - OPUS4-19595 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kipphardt, Heinrich A1 - Matschat, Ralf A1 - Panne, Ulrich T1 - Development of SI traceable standards for element determination JF - Chimia N2 - In Germany a system of primary amount of substance standards for elemental analysis is being developed, which forms the material´s basis for the National Standards for element determination. The metrological concept and technical approach is briefly described. The objective of traceability in chemistry, in this case for elemental determination, is illustrated on the example of copper. KW - Copper KW - Element determination KW - Metrology KW - Primary standards KW - Traceability PY - 2009 DO - https://doi.org/10.2533/chimia.2009.637 SN - 0009-4293 VL - 63 IS - 10 SP - 637 EP - 639 PB - Schweizerische Chemische Gesellschaft CY - Basel AN - OPUS4-20727 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kipphardt, Heinrich A1 - Matschat, Ralf A1 - Panne, Ulrich T1 - Metrology in chemistry - a rocky road JF - Microchimica acta N2 - The application of metrology in chemical analysis is today hampered by psychological and practical barriers. The argumentation is based on the differences in physical and chemical metrology, which arises mainly from the objects of the measurements. The term “measurement” is discussed in the realm of analytical chemistry with a special focus on the inherent relation between chemical identification and determination as well as the consequent use of the concept of traceability and uncertainty. KW - Metrology in chemistry KW - Chemical analysis KW - Traceability KW - Uncertainty PY - 2008 DO - https://doi.org/10.1007/s00604-007-0909-6 SN - 0026-3672 SN - 1436-5073 VL - 162 IS - 1-2 SP - 35 EP - 41 PB - Springer CY - Wien AN - OPUS4-17727 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bremser, Wolfram A1 - Becker, Roland A1 - Kipphardt, Heinrich A1 - Lehnik-Habrink, Petra A1 - Panne, Ulrich A1 - Töpfer, Antje T1 - Stability testing in an integrated scheme JF - Accreditation and quality assurance N2 - ISO Guide 35 deals with RM stability issues and scrutinizes the evaluation of stability testing results under the assumption that either there is no trend at all (a rather rare situation), or any observed deterministic change is insignificant and thus can be neglected. However, market demands for reliable reference materials are obviously not limited to stable or at least seemingly stable materials. In many analytical applications, analytes and measurands under consideration are known, or at least suspected, to be unstable on time scales that may vary widely from measurand to measurand. The Federal Institute for Materials Research and Testing (BAM) has developed (and successfully uses) an integrated approach in its certification practice. The approach is based on an initial stability study and subsequent post-certification monitoring. Data evaluation is model-based and takes advantage of all information collected in the stability testing scheme(s). It thus allows one to deal with any kind of instability observed, to assess limiting time intervals at any stress condition in the range tested, to estimate a final expiry date for materials with detected instabilities or the maximum admissible re-testing interval for seemingly stable materials, and to assess maximum admissible stress loads during delivery of the material to the customer. The article describes (and exemplifies) typical study layout, the model selection, and the integrated data assessment. KW - Certified reference materials KW - Stability KW - Shelf life KW - Arrhenius model KW - ERM PY - 2006 DO - https://doi.org/10.1007/s00769-006-0152-6 SN - 0949-1775 SN - 1432-0517 VL - 11 IS - 10 SP - 489 EP - 495 PB - Springer CY - Berlin AN - OPUS4-14063 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -