TY - JOUR A1 - Rackwitz, Vanessa A1 - Ostermann, Markus A1 - Panne, Ulrich A1 - Hodoroaba, Vasile-Dan T1 - Performance of mu-XRF with SEM/EDS for trace analysis on the example of RoHS relevant elements - measurement, optimisation and predivtion of the detection limits JF - Journal of analytical atomic spectrometry N2 - For ten years µ-XRF (micro-focus X-ray fluorescence) analysis has been performed with SEM/EDS (scanning electron microscope with an energy dispersive X-ray detector) so that non-destructive analysis of elements at trace level concentrations below 100 µg g-1 becomes possible. This can be considered as a valuable completion of the classical electron probe microanalysis by EDS, an analytical method 'suffering' from rather poor limits of detection in the range of one to two orders of magnitude higher than those of µ-XRF. Based on a representative actual application, namely analysis of RoHS relevant elements at trace concentration levels, the performance of the rather new analytical method with respect to its limits of detection is systematically evaluated. CRMs (certified reference materials) specially prepared to support the quantitative XRF analysis of RoHS relevant elements were employed. On the other side, based on calculations of µ-XRF spectra according to a recently developed physical model the optimization of the analytical performance is also successfully undertaken. KW - RoHS KW - XRF KW - muXRF KW - SEM/EDS KW - Detection limits KW - Trace elements KW - Modelling PY - 2013 DO - https://doi.org/10.1039/c3ja50064k SN - 0267-9477 SN - 1364-5544 VL - 28 IS - 9 SP - 1466 EP - 1474 PB - Royal Society of Chemistry CY - London AN - OPUS4-29045 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rackwitz, Vanessa A1 - Warrikhoff, A. A1 - Panne, Ulrich A1 - Hodoroaba, Vasile-Dan T1 - Determination of emitted X-ray tube spectra by means of a calibrated instrumental setup JF - Microscopy and microanalysis KW - X-ray tube spectrum KW - XRF KW - SEM KW - EDS KW - Spectrometer efficiency PY - 2010 DO - https://doi.org/10.1017/S1431927610054292 SN - 1431-9276 SN - 1435-8115 VL - 16 IS - Supplement S2 SP - 930 EP - 931 PB - Cambridge University Press CY - New York, NY AN - OPUS4-22471 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rackwitz, Vanessa A1 - Warrikhoff, A. A1 - Panne, Ulrich A1 - Hodoroaba, Vasile-Dan T1 - Determination of the efficiency of an energy dispersive X-ray spectrometer up to 50 keV with a SEM JF - Journal of analytical atomic spectrometry N2 - Both electron and polychromatic photon excitations (micro-focus X-ray source) at a scanning electron microscope (SEM) are used to determine the efficiency of an energy dispersive X-ray spectrometer up to 50 keV by means of a calibrated X-ray spectrometer and reference materials (RM) specially selected for this purpose. KW - Detector efficiency KW - Calibration KW - XRF KW - EDS KW - SEM KW - EDS-TM001 KW - Scattering PY - 2009 DO - https://doi.org/10.1039/b907815k SN - 0267-9477 SN - 1364-5544 VL - 24 SP - 1034 EP - 1036 PB - Royal Society of Chemistry CY - London AN - OPUS4-19714 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rackwitz, Vanessa A1 - Procop, M. A1 - Bjeoumikhova, S. A1 - Panne, Ulrich A1 - Hodoroaba, Vasile-Dan T1 - A routine procedure for the characterisation of polycapillary X-ray semi-lenses in prallelising mode with SEM/EDS JF - Journal of analytical atomic spectrometry N2 - The accurate knowledge of the properties of polycapillary X-ray semi-lenses has a significant influence on the quantitative results in a widespread field of applications involving microfocus X-ray beams. A routine procedure for the characterisation of a polycapillary X-ray semi-lens with a scanning electron microscope (SEM) having attached an energy dispersive spectrometer (EDS) is presented in this paper. A key issue of the procedure consists of fitting the semi-lens in front of the EDS for spectra acquisition. Relevant semi-lens parameters such as focal distance, full width at half maximum (FWHM) of the acceptance area, and transmission are determined in parallelising mode of the semi-lens. Special attention has been paid to the calculation of the transmission. KW - Polycapillary X-ray optics KW - Semi-lens KW - Parallelising mode KW - SEM KW - EDS KW - Acceptance area KW - FWHM KW - Transmission KW - Focal distance KW - XRF PY - 2011 DO - https://doi.org/10.1039/c0ja00135j SN - 0267-9477 SN - 1364-5544 VL - 26 IS - 3 SP - 499 EP - 504 PB - Royal Society of Chemistry CY - London AN - OPUS4-23555 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -