TY - JOUR A1 - Abad Andrade, Carlos Enrique A1 - Florek, S. A1 - Becker-Ross, H. A1 - Huang, M.-D. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Lippitz, Andreas A1 - Hodoroaba, Vasile-Dan A1 - Schmid, Thomas A1 - Heinrich, Hans-Joachim A1 - Recknagel, Sebastian A1 - Jakubowski, Norbert A1 - Panne, Ulrich T1 - Zirconium permanent modifiers for graphite furnaces used in absorption spectrometry: understanding their structure and mechanism of action N2 - The mechanism of action of zirconium permanent modifiers on graphite surfaces was investigated in order to understand its influence on the analytical signal in atomic and molecular absorption spectrometry (AAS/MAS). For this, the molecule formation of CaF was studied, which is used for the indirect analytical determination of fluorine in high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS). The kinetics of this reaction was established by monitoring its molecular spectrum at different atomisation temperatures. An Arrhenius plot showed a pseudo-first order reaction with respect to fluorine (n = 1). An intermediate state was isolated, and its structure was elucidated by spectroscopic methods: scanning electron microscopy with energy dispersive X-ray spectroscopy (SEMEDX), X-ray photoelectron spectroscopy (XPS), X-ray absorption spectroscopy (XANES and EXAFS), and Raman microspectroscopy. We propose here a mechanism, where ZrO2 acts as a heterogeneous catalyst: after a pyrolytic step, an intermediate state of ZrO(OCaF) is activated, and at higher temperatures, CaF(g) is released from the zirconium-coated graphite surface. No evidence of the formation of zirconium carbide was found. Consequently, as the CaF formation is catalysed by a heterogeneous catalyst, surface modifications with ZrO2 nanoparticles and ZrO xerogels were investigated in order to increase the surface area. Their influence was evaluated in the molecule formation of CaF, CaCl, CaBr, and CaI. Graphite furnace modification with zirconium oxide nanoparticles proves to be the best choice for fluorine analysis with a signal enhancement of more than eleven times with respect a non-coated graphite furnace. However, the influence of zirconium modifications in the analytical signals of Cl, and I is lower than the F signals or even negative in case of the Br. Understanding zirconium modifiers as heterogeneous catalysts offers a new perspective to AAS and MAS, and reveals the potential of surface analytical methods for development of improved permanent modifiers and graphite furnace coatings. KW - Zirconium KW - HR-CS-MAS KW - Graphite furnace KW - Nanoparticles KW - Xerogel KW - Calcium monofluoride KW - Absorption spectrometry PY - 2018 UR - https://pubs.rsc.org/en/content/articlelanding/2018/ja/c8ja00190a DO - https://doi.org/10.1039/C8JA00190A SN - 0267-9477 VL - 33 IS - 12 SP - 2034 EP - 2042 PB - Royal Society of Chemistry AN - OPUS4-46775 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Neamtu, M. A1 - Nadejde, C. A1 - Hodoroaba, Vasile-Dan A1 - Schneider, Rudolf A1 - Panne, Ulrich T1 - Singlet oxygen generation potential of porphyrin-sensitized magnetite nanoparticles: Synthesis, characterization and photocatalytic application N2 - Singlet oxygen generation potential of two novel free-base-porphyrin photocatalysts was investigated. The freebase-porphyrin-sensitized Fe3O4 magnetic nanoparticles (MNPs) were tested for the degradation of the model pollutant Bisphenol A (BPA) in aqueous solution, for the first time. MNPs with either cubic or spherical shape were synthesized using the sonochemical approach, followed by sensitizing with photoactive 4,4′,4′′,4′′′- (Porphine-5,10,15,20-tetrayl)tetrakis(benzoic acid) (TCPP). The resulted photocatalysts were characterized in detail by scanning and transmission electron microscopy, Brunauer–Emmett–Teller analysis, spectral techniques and vibrating sample magnetometry. The electron spin resonance experiments have confirmed the high activity of the photocatalysts through the efficient formation of singlet oxygen in solution. The optimum operational parameters for BPA degradation were established as follows: 1.0 μmol L−1 BPA, 1.0 g L−1 of photocatalyst, 100 μmol L−1 H2O2, under UVA irradiation. In these conditions, the results for both photocatalysts revealed that after only 10 min of reaction, over 64% and ca. 90% of BPA have been removed from solution in the absence and presence of H2O2, respectively. Whereas after 60 minutes of treatment, only 24% of BPA in real wastewater effluent samples were removed under UVA irradiation in the absence of H2O2, showing the high complexity of real wastewater. Moreover, both photocatalysts were successfully used for BPA removal in three consecutive runs, without significant loss of catalytic features. KW - Bisphenol A KW - Magnetpartikel KW - Photooxidation KW - Singulettsauerstoff KW - TEM KW - SEM KW - Brunauer-Emmett-Teller KW - Katalysator KW - Abwasser KW - ESR PY - 2018 DO - https://doi.org/10.1016/j.apcatb.2018.03.079 SN - 0926-3373 VL - 232 SP - 553 EP - 561 PB - Elsevier B.V. CY - Amsterdam, NL AN - OPUS4-45267 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Neamtu, M. A1 - Macaev, F. A1 - Boldescu, V. A1 - Hodoroaba, Vasile-Dan A1 - Nadejde, C. A1 - Schneider, Rudolf A1 - Paul, Andrea A1 - Ababei, G. A1 - Panne, Ulrich T1 - Removal of pollutants by the new Fenton-like highly active catalysts containing an imidazolium salt and a Schiff base N2 - Two iron-based molten salts comprising an imidazolium and Schiff base were evaluated as catalysts for removal of carbamazepine (CBZ) from water. The catalysts were fully characterized using scanning electron microscopy (SEM), energy-dispersive X-ray spectrometry (EDX), nuclear magnetic resonance spectroscopy (NMR), electrospray ionisation–mass spectrometry (ESI–MS), differential scanning calorimetry (DSC), Fourier transform infrared spectroscopy (FTIR) and nitrogen adsorption–desorption isotherms (BET). Additionally, the formation of photo-sensitized oxygen was investigated by spin-trapping using electron spin resonance (ESR). The catalytic activity in heterogeneous oxidation of the micropollutant (CBZ) was also evaluated. The effects of catalyst loading, pH, H2O2 dosage and UV light on the oxidation of the selected compound were investigated. After 15 min of UVA irradiation in the presence of 200 μM H2O2, CBZ was completely removed over both catalysts. KW - Fe-based highly active ionic liquids KW - Characterization of catalysts KW - Removal KW - Singlet oxygen KW - Carbamazepine PY - 2016 DO - https://doi.org/10.1016/j.apcatb.2015.10.032 SN - 0926-3373 VL - 183 SP - 335 EP - 342 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-35382 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nadejde, C. A1 - Neamtu, M. A1 - Hodoroaba, Vasile-Dan A1 - Schneider, Rudolf A1 - Paul, Andrea A1 - Ababei, G. A1 - Panne, Ulrich T1 - Green Fenton-like magnetic nanocatalysts: Synthesis, characterization and catalytic application N2 - Five iron oxalate core–shell magnetite nanoparticles catalysts are evaluated as magnetic heterogeneous materials. Simple and efficient procedures for the preparation of magnetic iron oxalate coated nanoparticles are presented. The catalysts are fully characterized using various investigation techniques. Additionally, the formation of photo-sensitized oxygen by spin-trapping using electron spin resonance is investigated. The catalytic activity of two model substrates (carbamazepine and bisphenol A) is also evaluated. The effect of operational parameters (catalyst and H2O2 concentration, UVA light) on the degradation performance of the oxidation process is investigated. The obtained reaction rates depend on the nature of the compound and increase with iron oxide shell thickness of the catalyst. Moreover, these materials show a significant activity during two consecutive tests. The optimum experimental parameters are found to be 1.0 g L-1 of catalysts, 10 mM H2O2, under UVA irradiation. More than 99% of both substrates are removed after 30 min of reaction time under the experimental conditions given above. The results obtained show that the catalysts are suitable candidates for the removal of pollutants in wastewaters by means of the Fenton heterogeneous reaction. KW - Magnetic core–shell nanocatalysts KW - Characterization KW - Fenton oxidation KW - Micropollutants KW - Water treatment PY - 2015 DO - https://doi.org/10.1016/j.apcatb.2015.04.050 SN - 0926-3373 SN - 1873-3883 VL - 176-177 SP - 667 EP - 677 PB - Elsevier CY - Amsterdam AN - OPUS4-33820 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Recknagel, Sebastian A1 - Koch, Matthias A1 - Wise, S. A. A1 - Panne, Ulrich T1 - Fifteenth international symposium on biological and environmental reference materials (BERM-15) N2 - The 15th International Symposium on Biological and Environmental Reference Materials (BERM-15), organized by BAM, took place at in Berlin in September 2018. An overview on main topics of the conference is given. KW - BERM KW - Reference materials PY - 2019 DO - https://doi.org/10.1007/s00769-019-01377-9 SN - 1432-0517 SN - 0949-1775 VL - 24 IS - 3 SP - 249 EP - 250 PB - Springer Verlag AN - OPUS4-48203 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Löhr, Konrad A1 - Borovinskaya, O. A1 - Tourniaire, G. A1 - Panne, Ulrich A1 - Jakubowski, Norbert T1 - Arraying of single cells for quantitative high throughput laser ablation ICP-TOF-MS N2 - Arraying of single cells for mass spectrometric analysis is a considerable bioanalytical challenge. In this study, we employ a novel single cell arraying technology for quantitative analysis and isotopic fingerprinting by laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-TOF-MS). The single cell arraying approach is based on a piezo-acoustic microarrayer with software for automated optical detection of cells within the piezo dispense capillary (PDC) prior to arraying. Using optimized parameters, single cell occupancy of >99%, high throughput (up to 550 cells per hour), and a high cell recovery of >66% is achieved. LA-ICP-TOF-MS is employed to detect naturally occurring isotopes in the whole mass range as fingerprints of individual cells. Moreover, precise quantitative determination of metal-containing cell dyes is possible down to contents of ∼100 ag using calibration standards which were produced using the same arrayer. KW - Laser ablation KW - Cell KW - Array KW - ICP-MS PY - 2019 DO - https://doi.org/10.1021/acs.analchem.9b00198 SN - 0003-2700 SN - 1520-6882 VL - 91 IS - 18 SP - 11520 EP - 11528 PB - American Chemical Society (ACS Publications) CY - Washington AN - OPUS4-48985 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bauer, M. A1 - Remmler, D. A1 - Dallmann, A. A1 - Jakubowski, Norbert A1 - Börner, H. G. A1 - Panne, Ulrich A1 - Limberg, C. T1 - Specific Decoration of a Discrete Bismuth Oxido Cluster by Selected Peptides towards the Design of Metal Tags N2 - Metal tags find application in a multitude of biomedical systems and the combination with laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) offers an opportunity for multiplexing. To lay the foundation for an increase of the signal intensities in such processes, we herein present a general approach for efficient functionalization of a well-defined metal oxido cluster [Bi6O4(OH)(4)(SO3CF3)(6)(CH3CN)(6)].2 CH3CN (1), which can be realized by selecting 7mer peptide sequences via combinatorial means from large one-bead one-compound peptide libraries. Selective cluster-binding peptide sequences (CBS) for 1 were discriminated from non-binders by treatment with H2S gas to form the reduction product Bi2S3, clearly visible to the naked eye. Interactions were further confirmed by NMR experiments. Extension of a binding peptide with a maleimide linker (Mal) introduces the possibility to covalently attach thiol-bearing moieties such as biological probes and for their analysis the presence of the cluster instead of mononuclear entities should lead to an increase of signal intensities in LA-ICP-MS measurements. To prove this, CBS-Mal was covalently bound onto thiol-presenting glass substrates, which then captured 1 effectively, so that LA-ICP-MS measurements demonstrated drastic signal amplification compared to single lanthanide tags. KW - Peptide library KW - Mass spectrometry KW - Laser ablation KW - Cluster KW - Bioconjugation PY - 2019 DO - https://doi.org/10.1002/chem.201805234 SN - 0947-6539 VL - 25 IS - 3 SP - 759 EP - 763 PB - John Wiley & Sons, Inc. AN - OPUS4-47324 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Panne, Ulrich T1 - Digital Analytical Sciences N2 - Based on inductive reasoning scientific inquiry in Analytical Sciences has a long tradition. The talk addresses in which way the digital transformation will change the scientific paradigm in Analytical Sciences to a data-driven discipline. Three main areas, integration, instruments, and methods, are discussed in their transformation through machine learning and other digital tools. Finally, some shortcomings and pitfalls in the deployments of algorithmic shortcuts are illustrated. T2 - ANAKON Münster CY - Westfälischen Wilhelms-Universität (WWU), Münster, Germany DA - 25.03.2019 KW - Digital transformation KW - Analytical Sciences KW - Digital PY - 2019 AN - OPUS4-47735 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Panne, Ulrich T1 - Analytical Sciences: From Ostwald's maid to enabling science N2 - The talk will address the paradigm shift in Analytical Sciences in regard to chemistry as a discipline. To illustrate this metamorphose examples from spectroschemical analysis, ufluidics, bioanalysis, and the didgital transformation of analytical sciences are discussed. T2 - GDCh-Wissenschaftsforum 2019 CY - Aachen, Germany DA - 15.09.2019 KW - Spectrochemical analysis KW - Analytical Sciences PY - 2019 AN - OPUS4-51471 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nadejde, C. A1 - Neamtu, Mariana A1 - Hodoroaba, Vasile-Dan A1 - Schneider, Rudolf A1 - Paul, Andrea A1 - Ababei, G. A1 - Panne, Ulrich T1 - Green Fenton-like catalysts for the removal of water pollutants N2 - Two types of surface modified magnetite (Fe3O4) nanoparticles, coated with either tannic acid (TA) or dissolved natural organic matter (NOM), were evaluated as magnetic heterogeneous catalysts. Simple and efficient procedures for the synthesis of the magnetic catalysts were employed, their properties being fully assessed by various characterization techniques. The catalytic activity in heterogeneous oxidation of aqueous solutions containing Bisphenol A (BPA) over the catalysts was comparatively studied. The optimum experimental parameters were: 1g/L of catalysts, 10 mM H2O2, under UV irradiation. The highest mineralization rates were observed for Fe3O4-TA catalyst. More than 80% of BPA were removed after 30 minutes of reaction time under the specified experimental conditions. The results showed that the obtained catalysts are suitable candidates for the removal of pollutants in wastewaters by means of heterogeneous reaction T2 - TechConnect World Innovation Conference Nanotech 2015 CY - Washington, DC, Maryland, USA DA - 14.06.2015 KW - Nanocatalysts KW - Characterization KW - Fenton oxidation KW - Wastewater KW - Bisphenol A degradation PY - 2015 SN - 978-1- 4987-4733-2 SN - 978-1-4987-4728-8 VL - 2 SP - 87 EP - 90 PB - CRC Press, Taylor&Francis Group AN - OPUS4-40074 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rackwitz, Vanessa A1 - Panne, Ulrich A1 - Hodoroaba, Vasile-Dan T1 - Calculation of X-ray tube spectra by means of photon generation yields and a modified Kramers background for side-window X-ray tubes N2 - Popular X-ray tube models available in the literature, i.e. 'Pella', 'Ebel', and 'Finkelshtein and Pavlova', are systematically evaluated with the focus on the estimation of the associated uncertainties. Also taken in consideration and compared is our recent semi-empirical own approach already employed in our lab. This has been working for the common target elements rhodium, molybdenum and tungsten and was further extended in the present work for the target elements copper, chromium and vanadium. By using a modern scanning electron microscope/energy dispersive spectroscopy (SEM/EDS) system this time, higher performances such as stability of the beam current and especially the better energy resolution of the EDS have enabled the reliable extension of our own X-ray tube spectrum approach into the low-energy range, due to increasing interest. Hence, also the more challenging X-ray lines of copper, chromium and vanadium L-series lying in the energy range below 1–2?keV are included into the model. Such low-energy L-lines or, e.g. M-lines of tungsten, are not treated explicitly by the other existing popular algorithms for the nowadays widely used geometries of side-window tubes, offering a unique virtue to our present, modern approach. With our own model, a measurement uncertainty of the X-ray tube spectra (considering the uncertainties associated with the SEM beam current, the detector acceptance solid angle and efficiency of the spectrometer) within 15% has been estimated. The validation of the approach is demonstrated with metrological measurements with a calibrated SEM/EDS system geometrically configured as a side-window X-ray tube. KW - X-ray tube spectra KW - Side-window X-ray tube KW - Reference-free XRF KW - Photon generation yield KW - Kramers background KW - Calibrated SEM/EDS PY - 2012 DO - https://doi.org/10.1002/xrs.2391 SN - 0049-8246 VL - 41 IS - 4 SP - 264 EP - 272 PB - Wiley CY - Chichester AN - OPUS4-26239 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nadejde, C. A1 - Neamtu, Mariana A1 - Hodoroaba, Vasile-Dan A1 - Schneider, Rudolf A1 - Ababei, G. A1 - Panne, Ulrich T1 - Characterization and application of Green Fenton-like catalysts for the removal of water pollutants N2 - Three types of magnetite-chitosan/iron oxalate/iron citrate nanoparticles (NP) were evaluated as magnetic heterogeneous catalysts for water treatment. T2 - PTIM 2015, 1st International Caparica Conference on Pollutant Toxic Ions and Molecules CY - Caparica, Portugal DA - 02.112015 KW - Bisphenol A degradation KW - Nanocatalysts KW - Characterization KW - Fenton oxidation KW - Wastewater PY - 2015 SN - 978-989-99361-6-4 SP - 186 EP - 187 PB - Proteomass AN - OPUS4-40082 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rackwitz, Vanessa A1 - Warrikhoff, A. A1 - Panne, Ulrich A1 - Hodoroaba, Vasile-Dan T1 - Determination of the efficiency of an energy dispersive X-ray spectrometer up to 50 keV with a SEM N2 - Both electron and polychromatic photon excitations (micro-focus X-ray source) at a scanning electron microscope (SEM) are used to determine the efficiency of an energy dispersive X-ray spectrometer up to 50 keV by means of a calibrated X-ray spectrometer and reference materials (RM) specially selected for this purpose. KW - Detector efficiency KW - Calibration KW - XRF KW - EDS KW - SEM KW - EDS-TM001 KW - Scattering PY - 2009 DO - https://doi.org/10.1039/b907815k SN - 0267-9477 SN - 1364-5544 VL - 24 SP - 1034 EP - 1036 PB - Royal Society of Chemistry CY - London AN - OPUS4-19714 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rackwitz, Vanessa A1 - Procop, M. A1 - Bjeoumikhova, S. A1 - Panne, Ulrich A1 - Hodoroaba, Vasile-Dan T1 - A routine procedure for the characterisation of polycapillary X-ray semi-lenses in prallelising mode with SEM/EDS N2 - The accurate knowledge of the properties of polycapillary X-ray semi-lenses has a significant influence on the quantitative results in a widespread field of applications involving microfocus X-ray beams. A routine procedure for the characterisation of a polycapillary X-ray semi-lens with a scanning electron microscope (SEM) having attached an energy dispersive spectrometer (EDS) is presented in this paper. A key issue of the procedure consists of fitting the semi-lens in front of the EDS for spectra acquisition. Relevant semi-lens parameters such as focal distance, full width at half maximum (FWHM) of the acceptance area, and transmission are determined in parallelising mode of the semi-lens. Special attention has been paid to the calculation of the transmission. KW - Polycapillary X-ray optics KW - Semi-lens KW - Parallelising mode KW - SEM KW - EDS KW - Acceptance area KW - FWHM KW - Transmission KW - Focal distance KW - XRF PY - 2011 DO - https://doi.org/10.1039/c0ja00135j SN - 0267-9477 SN - 1364-5544 VL - 26 IS - 3 SP - 499 EP - 504 PB - Royal Society of Chemistry CY - London AN - OPUS4-23555 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Morcillo, Dalia A1 - Winckelmann, Alexander A1 - Oelze, Marcus A1 - Leonhardt, Robert A1 - Schmidt, Anita A1 - Richter, Silke A1 - Recknagel, Sebastian A1 - Vogl, Jochen A1 - Panne, Ulrich A1 - Abad Andrade, Carlos Enrique T1 - Exploring Age-Induced Lithium Isotope Fractionation in Lithium-Ion Batteries using Microwave-Induced Cold Nitrogen Plasma Mass Spectrometry N2 - This study explores Microwave-Inductively Coupled Atmospheric-pressure Plasma Mass Spectrometry (MICAP-MS) as a cost-effective alternative to Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS) for analyzing lithium isotopic composition in lithium-ion batteries (LIBs). We investigate the performance of MICAP-MS in measuring Li isotope ratios in new and aged commercial lithium cobalt oxide (LCO) batteries. Our results show that MICAP-MS, operating under cold plasma conditions at 800 W with an 8 mm torch position, achieves results metrologically compatible with MC-ICP-MS, with a precision ranging from 0.6‰ to 3.4‰ for δ7Li values. MICAP-MS benefits from a dielectric resonator for uniform plasma, better ion velocity control, and higher energy efficiency. Optimal settings were identified with dwell times of 10 ms for 6Li and 1 ms for 7Li. The study of LIBs revealed that 6Li migrates towards the anode over multiple charge–discharge cycles, causing 7Li to accumulate in the cathode, a fractionation effect that becomes more pronounced with prolonged cycling. MICAP-MS provides a cost-effective, precise alternative to MC-ICP-MS, with lower operational costs and enhanced portability, advancing the study of isotopic fractionation and aging in lithium-ion batteries. KW - MICAP-MS KW - Lithium KW - Battery aging KW - Lithium isotopes KW - Nitrogen plasma KW - Isotope fractionation KW - lithium cobalt oxide KW - LCO PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-643777 DO - https://doi.org/10.1039/d4ja00324a SN - 0267-9477 SP - 1 EP - 11 PB - Royal Society of Chemistry (RSC) AN - OPUS4-64377 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Sötebier, Carina A. A1 - Kutscher, D. J. A1 - Rottmann, L. A1 - Jakubowski, Norbert A1 - Panne, Ulrich A1 - Bettmer, J. T1 - Combination of single particle ICP-QMS and isotope dilution analysis for the determination of size, particle number and number size distribution of silver nanoparticles N2 - Single particle ICP-MS (spICP-MS) has gained great influence in the analysis of engineered nanoparticles (NPs) due to its simplicity, speed and ability to obtain a particle number size distribution. Despite its many advantages, the method is hampered by matrix effects affecting the sensitivity of the instruments. Consequently, over- or underestimated particle sizes might be obtained. To overcome these challenges, we present in this work the detection of both Ag isotopes with a quadrupole mass spectrometer for the application of isotopic dilution analysis (IDA) in combination with spICP-MS. Here, the isotopes are measured sequentially using the conventional spICP-MS integration time of 10 ms. Citrate stabilized Ag NPs of a spherical shape with the nominal diameters of 30, 40, 50 and 80 nm have been investigated. The experimental concept of adding ¹⁰⁹Ag+ solutions to the NP suspensions resulted in the NP Spikes being only visible in the ¹⁰⁷Ag trace. Therefore, a maximum of 45% of the particles was detected compared to that by conventional spICP-MS. A modified mass flow equation was applied to determine the particle sizes, particle size distributions and particle number concentrations of various Ag NPs. The addition of different spike concentrations between 0.5 and 4 mg L⁻¹ ¹⁰⁹Ag resulted in similar particle diameters, suggesting that the calculated diameter might be independent of the spike concentration. This would have the advantage that no size information would be needed before the analysis. By analyzing Ag NP suspensions in a simulated seawater matrix, we demonstrate its significant influence on the particle size determination using conventional spICP-MS. A lower transport efficiency of 6.1% was found in the matrix compared to 7.3% without the matrix. In our approach, the addition of the Matrix influenced the NP intensity stronger than the spike signal, resulting in slightly smaller diameters using IDA–spICP-MS with the matrix compared to the results without the matrix. On the other hand, the IDA–spICP-MS approach with the matrix can result in equivalent results for the particle sizes compared with conventional spICP-MS using suspensions without the matrix. Due to the lower instrument sensitivity in the matrix, a diameter of 30 nm was found to be close to the detection limit of the instrument. KW - Ag nanoparticles KW - Single particle ICP-MS KW - Matrix influence KW - Isotope dilution analysis PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-376490 DO - https://doi.org/10.1039/c6ja00137h SN - 0267-9477 VL - 31 IS - 10 SP - 2045 EP - 2052 AN - OPUS4-37649 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kühn, Andreas A1 - Scharf, Oliver A1 - Ordavo, I. A1 - Riesemeier, Heinrich A1 - Reinholz, Uwe A1 - Radtke, Martin A1 - Berger, Achim A1 - Ostermann, Markus A1 - Panne, Ulrich T1 - Pushing the limits for fast spatially resolved elemental distribution patterns N2 - A new setup for fast spatially resolved measurements of elemental trace amounts under total reflection conditions using a new colour X-ray camera is described. Samples prepared on conventional total reflection X-ray fluorescence (TXRF) reflectors were measured at BESSY II synchrotron. A spatial resolution of 50 × 50 µm² was obtained, while the required time for the investigation of a 10 × 10 mm² sample is 30 seconds. The set-up is up to 350 times faster than conventional X-ray fluorescence systems for elemental traces. The major components of the X-ray camera are polycapillary optics and a pn-CCD chip with an active area of 13 × 13 mm². This area is divided into 264 × 264 pixels of 48 × 48 µm². A full X-ray spectrum with a resolution of 152 eV @ 5.9 keV and a chip temperature of 246 K is recorded for each pixel. The chip has a read-out rate of 400 Hz. PY - 2011 DO - https://doi.org/10.1039/c1ja10069f SN - 0267-9477 SN - 1364-5544 VL - 26 SP - 1986 EP - 1989 PB - Royal Society of Chemistry CY - London AN - OPUS4-24386 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Walter, Astrid A1 - Panne, Ulrich A1 - Weller, Michael G. T1 - A novel immunoreagent for the specific and sensitive detection of the explosive triacetone triperoxide (TATP) N2 - Triacetone triperoxide (TATP) is a primary explosive, which was used in various terrorist attacks in the past. For the development of biosensors, immunochemical µ-TAS, electronic noses, immunological test kits, or test strips, the availability of antibodies of high quality is crucial. Recently, we presented the successful immunization of mice, based on the design, synthesis, and conjugation of a novel TATP derivative. Here, the long-term immunization of rabbits is shown, which resulted in antibodies of extreme selectivity and more than 1,000 times better affinity in relation to the antibodies from mice. Detection limits below 10 ng L-1 (water) were achieved. The working range covers more than four decades, calculated from a precision profile. The cross-reactivity tests revealed an extraordinary selectivity of the antibodies—not a single compound could be identified as a relevant cross-reactant. The presented immunoreagent might be a major step for the development of highly sensitive and selective TATP detectors particularly for security applications. KW - Organic peroxides KW - Terrorism KW - Biosensor development PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-240291 UR - http://www.mdpi.com/2079-6374/1/3/93 DO - https://doi.org/10.3390/bios1030093 SN - 2079-6374 VL - 1 IS - 3 SP - 93 EP - 106 PB - MDPI CY - Basel AN - OPUS4-24029 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Giesen, Charlotte A1 - Jakubowski, Norbert A1 - Panne, Ulrich A1 - Weller, Michael G. T1 - Comparison of ICP-MS and photometric detection of an immunoassay for the determination of ochratoxin A in wine N2 - An immunoassay was developed for ochratoxin A (OTA) detection in wine and two completely different detection methods were compared: ICP-MS and photometry. For labelling, we applied secondary antibodies conjugated with gold nanoparticles for ICP-MS and with horseradish peroxidase for photometric detection, respectively. Detection limits of the assay were determined as 0.003 µg L-1 for both detection methods. OTA in wine was determined below the EU limit value of 2 µg kg-1. The measurement range was between 0.01 and 1 µg L-1 for ICP-MS and photometric detection. Assay precision detected by ICP-MS and photometry were similar showing that precision of the detection method has only a minor effect on total assay precision. By using BSA as a buffer additive to minimize nonspecific binding, we could also confirm that OTA strongly binds to BSA. In a comparison study of several additives, casein was found to be preferable. PY - 2010 DO - https://doi.org/10.1039/c0ja00009d SN - 0267-9477 SN - 1364-5544 VL - 25 IS - 10 SP - 1567 EP - 1572 PB - Royal Society of Chemistry CY - London AN - OPUS4-22704 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carvalho, José Joao A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - Monitoring caffeine in human saliva using a newly developed ELISA N2 - Caffeine is a useful indicator to quickly assess liver function. High-throughput tests are needed for single-point caffeine measurements, with low cross-reactivity toward its major metabolite, paraxanthine. A newly developed ELISA was compared with an LC-MS/MS reference method, using 60 saliva samples from 10 individuals, before and after caffeine intake. Bland-Altman plot, Student t-test and F-test were used to compare the two methods. Proteins were precipitated using organic solvent and the caffeine recoveries compared with those obtained using sample microfiltration. The antibody, with a low cross-reactivity toward paraxanthine (0.08%), allows quantification of caffeine in saliva samples from 2.5 µg/L to 125 µg/L with high precision and the ELISA shows comparable results to those obtained by LC-MS/MS. A one-step protein precipitation using an organic solvent provides comparable results to a more costly and time-consuming microfiltration pre-treatment of samples. The new ELISA is a fit-for-purpose method to accurately and precisely determine caffeine in saliva samples. KW - Caffeine KW - Cytochrome P450 CYP1A2 KW - Enzyme-linked immunosorbent assay KW - LC-MS/MS KW - Liver function tests KW - Saliva PY - 2012 DO - https://doi.org/10.1080/00032719.2012.696226 SN - 0003-2719 SN - 1532-236X VL - 45 IS - 17 SP - 2549 EP - 2561 PB - Taylor & Francis CY - Philadelphia, Pa. AN - OPUS4-27267 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bahlmann, Arnold A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - Monitoring carbamazepine in surface and wastewaters by an immunoassay based on a monoclonal antibody N2 - The pharmaceutical compound carbamazepine (CBZ) is an emerging pollutant in the aquatic environment and may potentially be used as a wastewater marker. In this work, an enzyme-linked immunosorbent assay (ELISA) for the detection of carbamazepine in surface and sewage waters has been developed. The heterogeneous immunoassay is based on a commercially available monoclonal antibody and a novel enzyme conjugate (tracer) that links the hapten via a hydrophilic peptide (triglycine) spacer to horseradish peroxidase. The assay achieves a limit of detection of 24 ng/L and a quantitation range of 0.05-50 µg/L. The analytical performance and figure of merits were compared to liquid chromatography-tandem mass spectrometry after solid-phase extraction. For nine Berlin surface water samples and one wastewater sample, a close correlation of results was observed. A constant overestimation relative to the CBZ concentration of approximately 30% by ELISA is probably caused by the presence of 10,11-epoxy-CBZ and 2-hydroxy-CBZ in the samples. The ELISA displayed cross-reactivities for these compounds of 83% and 14%, respectively. In a first screening of 27 surface water samples, CBZ was detected in every sample with concentrations between 0.05 and 3.2 µg/L. Since no sample cleanup is required, the assay allowed for the determination of carbamazepine with high sensitivity at low costs and with much higher throughput than with conventional methods. KW - Carbamazepine KW - ELISA KW - Antibody KW - Immunoassay KW - Surface water KW - LC-MS/MS KW - Pharmaceuticals PY - 2009 DO - https://doi.org/10.1007/s00216-009-2958-7 SN - 1618-2642 SN - 1618-2650 VL - 395 IS - 6 SP - 1809 EP - 1820 PB - Springer CY - Berlin AN - OPUS4-20927 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carvalho, José Joao A1 - Walter, Astrid A1 - Baermann, Yvonne A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schenk, J.A. A1 - Schneider, Rudolf T1 - Non-invasive monitoring of immunization progress in mice via IgG from feces N2 - A non-invasive method to monitor the humoral immune response in mice after immunization is described. From fecal pellets of an individual mouse, a sufficient amount of active immunoglobulins or their fragments can be extracted to perform a regular examination of the status of the immune response by immunoassay. Hapten-specific antibodies from the feces of mice from three immunization trials showed very similar characteristics to those obtained from serum at a given date. Therefore, it can be suspected that some serum IgG enters the intestinal lumen and ends up in the feces, where they appear to be considerably stable. Hapten-specific IgAs were not found in the feces. Being able to analyze antibody titers in feces could be an interesting animal welfare refinement to standard practice that does not entail repeated blood sampling. KW - Immunization monitoring KW - IgG KW - Coproantibodies KW - Feces KW - Animal welfare KW - 3R concept PY - 2012 UR - http://iv.iiarjournals.org/content/26/1/63.full.pdf+html SN - 0258-851x VL - 26 IS - 1 SP - 63 EP - 70 PB - In vivo CY - Athens AN - OPUS4-25283 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Panne, Ulrich T1 - Process Sensing and Chemical Sensor Development at BAM T2 - Sitzung des fms/ProcessNet-Gemeinschafts-Ausschusses „Sensoren und Sensorsysteme“ CY - Frankfurt am Main, Germany DA - 2012-01-26 PY - 2012 AN - OPUS4-24645 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Walter, Astrid A1 - Pfeifer, Dietmar A1 - Kraus, Werner A1 - Emmerling, Franziska A1 - Schneider, Rudolf A1 - Panne, Ulrich A1 - Weller, Michael G. T1 - Triacetone Triperoxide (TATP): Hapten design and development of antibodies N2 - Triacetone triperoxide (TATP), an improvised explosive, is a potential security threat because of its cost-efficient synthesis and the difficulty in detecting it. A highly selective antibody could provide the necessary specificity to the detection process. To obtain antibodies, a hapten made from acetone, hydrogen peroxide, and 7-oxooctanoic acid has been designed, synthesized, and confirmed by NMR that displays the utmost similarity to the analyte. The single-crystal X-ray structures of the solvated species TATP·methanol (1:1) and the TATP derivate were determined. In both compounds, the molecules exhibit D3 symmetry and adopt a twisted boat-chair conformation. The hapten was coupled to bovine serum albumin, and mice were immunized. An immune response against TATP was elicited, and selective antibodies were detected in the mouse serum, which should be very useful for the development of a TATP biosensor system. An ELISA with a limit of detection for TATP of 65 µg L-1 is shown. KW - TATP KW - Triacetone triperoxide KW - Explosive KW - Antibody KW - Hapten immunoassay KW - Structure PY - 2010 DO - https://doi.org/10.1021/la1018339 SN - 0743-7463 SN - 1520-5827 VL - 26 IS - 19 SP - 15418 EP - 15423 PB - American Chemical Society CY - Washington, DC AN - OPUS4-22469 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carvalho, José Joao A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - A highly sensitive caffeine immunoassay based on a monoclonal antibody KW - Caffeine KW - ELISA KW - Antibody KW - LC–MS–MS KW - Water KW - Wastewater marker PY - 2010 DO - https://doi.org/10.1007/s00216-010-3506-1 SN - 1618-2642 SN - 1618-2650 VL - 396 IS - 7 SP - 2617 EP - 2628 PB - Springer CY - Berlin AN - OPUS4-22651 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Giesen, Charlotte A1 - Jakubowski, Norbert A1 - Panne, Ulrich A1 - Weller, Michael G. T1 - Ochratoxin-A-Bestimmung in Wein mittels eines ICP-MS-basierten Immunoassays PY - 2010 UR - http://www.analytik-news.de/Fachartikel/Volltext/BAM2.pdf SP - 1 EP - 6 PB - Dr. Beyer Internet-Beratung CY - Ober-Ramstadt AN - OPUS4-22702 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bahlmann, Arnold A1 - Carvalho, José Joao A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - Immunoassays as high-throughput tools: monitoring spatial and temporal variations of carbamazepine, caffeine and cetirizine in surface and wastewaters N2 - Carbamazepine (CBZ), caffeine and cetirizine were monitored by enzyme-linked immunosorbent assays (ELISAs) in surface and wastewaters from Berlin, Germany. This fast and cost-efficient method enabled to assess the spatial and temporal variation of these anthropogenic markers in a high-throughput screening. CBZ and cetirizine were detected by the same antibody, which selectively discriminates between both compounds depending on the pH value used in the incubation step. To our best knowledge, this is the first dual-analyte immunoassay working with a single antibody. The frequent sampling with 487 samples being processed allowed for the repeated detection of unusually high concentrations of CBZ and caffeine. ELISA results correlate well with the ones obtained by liquid chromatography tandem mass spectrometry (LC-MS/MS). Caffeine concentrations found in surface waters were elevated by combined sewer overflows after stormwater events. During the hay fever season, the concentrations of the antihistamine drug cetirizine increased in both surface and wastewaters. Caffeine was almost completely removed during wastewater treatment, while CBZ and cetirizine were found to be more persistent. The maximum concentrations of caffeine, CBZ and cetirizine found in influent wastewater by LC–MS/MS were 470, 5.0 and 0.49 µg L-1, while in effluent wastewater the concentrations were 0.22, 4.5 and 0.51 µg L-1, respectively. For surface waters, concentrations up to 3.3, 4.5 and 0.72 µg L-1 were found, respectively. KW - ELISA KW - Carbamazepine KW - Caffeine KW - Cetirizine KW - Environmental monitoring KW - Anthropogenic markers PY - 2012 DO - https://doi.org/10.1016/j.chemosphere.2012.05.020 SN - 0045-6535 SN - 0366-7111 VL - 89 IS - 11 SP - 1278 EP - 1286 PB - Elsevier Science CY - Kidlington, Oxford AN - OPUS4-26187 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Morcillo, Dalia A1 - Oelze, Marcus A1 - Seena Prem, Pranav A1 - de Oliveira Guilherme Buzanich, Ana A1 - Emmerling, Franziska A1 - Recknagel, Sebastian A1 - Panne, Ulrich A1 - Abad Andrade, Carlos Enrique T1 - Lithium isotope fractionation as an early indicator of degradation mechanisms in lithium-ion batteries N2 - Aging in lithium-ion batteries (LIBs) degrades performance and hinders sustainability, demanding advanced diagnostics for early failure prediction. We investigate lithium isotope fractionation (LIF) as an innovative probe of degradation in lithium cobalt oxide (LCO) coin cells aged over 0−700 cycles. High-precision multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) quantified δ7Li variations across cell stages: non-cycled (0 cycles), newly formed (5 cycles), semi-aged (250 cycles), and fully aged (700 cycles). During early cycling (≤ 45 cycles), chemical processes drive 7Li enrichment at the anode (δ7Li vs LSVEC = +12 ‰) through solid electrolyte interphase (SEI) formation, while the cathode depletes in 7Li (δ7Li vs LSVEC = −0.7 ‰). Beyond 45 cycles, electric field-induced migration predominates, promoting 6Li intercalation into the anode and increasing the δ7Li of the cathode by 8.1 ‰. Mass balance verifies isotope conservation, attributing shifts to redistribution and trapping. Complementary electrochemical impedance spectroscopy (EIS) and X-ray absorption spectroscopy and diffraction confirm SEI expansion, cobalt oxidation, lattice shrinkage, and changes in electrode structure, corroborating LIF trends. Notably, a δ7Li inflection at approximately 270 cycles anticipates end-of-life by 70 cycles, surpassing traditional methods in sensitivity. LIF emerges as a predictive indicator of aging mechanisms, informing optimized designs for durable LIBs. KW - Lithium isotope fractionation KW - Lithium-ion batteries KW - Degradation mechanisms KW - LiCoO2 cathodes KW - LCO KW - Isotopic tracing KW - Lithium isotopes PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-650945 DO - https://doi.org/10.26434/chemrxiv-2025-16lvq SP - 1 EP - 19 AN - OPUS4-65094 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Leiterer, Jork A1 - Emmerling, Franziska A1 - Panne, Ulrich A1 - Christen, W. A1 - Rademann, K. T1 - Tracing Coffee Tabletop Traces N2 - Crystallization processes under different conditions are of fundamental interest in chemistry, pharmacy, and medicine. Therefore, we have studied the formation of micro- and nanosized crystals using water-caffeine (1,3,7-trimethyl-1H-purine-2,6(3H,7H)-dione) solutions under ambient conditions as a relevant model system. When droplets of an aqueous caffeine solution evaporate and eventually dry on surfaces (glass, polystyrene, and polyester), stable “coffee tabletop” rings with a perimeter of typically 3 mm are formed after 20 to 50 min. Using a micro focus X-ray beam available at the BESSY µSpot-beamline, the fine structure of different caffeine needles can be distinguished. Unexpectedly, both crystal modifications (α- and β-caffeine) are present, but locally separated in these rings. Furthermore, AFM studies reveal the presence of even smaller particles on a nanometer length scale. To eliminate influences of surface irregularities from the crystallization process, acoustic levitation of liquid samples was employed. Such levitated droplets are trapped in a stable position and only surrounded by air. The solvent in an ultrasonically levitated drop evaporates completely, and the resulting crystallization of caffeine was followed in situ by synchrotron X-ray diffraction. In this case, the diffraction pattern is in accordance with pure α-caffeine and does not indicate the formation of the room temperature polymorph β-caffeine. Hence, our investigations open new vistas that may lead to a controlled formation of cocrystals and novel polymorphs of micro- and nanocrystalline materials, which are of relevance for fundamental studies as well as for pharmaceutical and medical applications. KW - Polymorphism KW - Crystallization KW - Acoustic levitation KW - Evaporation of droplets KW - µSpot KW - Micro spot KW - Synchrotron radiation PY - 2008 DO - https://doi.org/10.1021/la800768v SN - 0743-7463 SN - 1520-5827 VL - 24 IS - 15 SP - 7970 EP - 7978 PB - American Chemical Society CY - Washington, DC AN - OPUS4-17818 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schenk, Jonas A1 - Batzdorf, Lisa A1 - Emmerling, Franziska A1 - Kneipp, Janina A1 - Panne, Ulrich A1 - Buurman, Merwe T1 - Simultaneous UV/Vis spectroscopy and surface enhanced raman scattering of nanoparticle formation and aggregation in levitated droplets N2 - The formation and growth of hydroxylamine reduced silver nanoparticles were investigated by simultaneous Raman and UV/Vis spectroscopy coupled to an acoustic levitator as a sample holder. Based on the UV/Vis spectra, a two step particle formation mechanism with fast initial formation and adjacent coalescence can be proposed for the reduction of silver nitrate with hydroxylamine. The presence of the analyte adenine during particle formation resulted in differences in the adenine SERS signature compared to experiments, where adenine was added after particle synthesis. It was possible to monitor the adenine and sodium chloride induced aggregation of the nanoparticles and its dynamics based on both the extinction spectra and the SERS data. Correlating the information from the extinction spectra with the SERS intensity, the maximum SERS signals were observed at maximum extinction of the aggregated nanoparticle solution at the Raman excitation wavelength. PY - 2012 DO - https://doi.org/10.1039/c2ay05744a SN - 1759-9660 SN - 1759-9679 N1 - Geburtsname von Batzdorf, Lisa: Tröbs, L. - Birth name of Batzdorf, Lisa: Tröbs, L. N1 - Geburtsname von Buurman, Merwe: Albrecht, M. - Birth name of Buurman, Merwe: Albrecht, M. VL - 4 IS - 5 SP - 1252 EP - 1258 PB - RSC Publ. CY - Cambridge AN - OPUS4-25742 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schlegel, Moritz-Caspar A1 - Wenzel, Klaus-Jürgen A1 - Sarfraz, Adnan A1 - Panne, Ulrich A1 - Emmerling, Franziska T1 - A wall-free climate unit for acoustic levitators N2 - Acoustic levitation represents the physical background of trapping a sample in a standing acoustic wave with no contact to the wave generating device. For the last three decades, sample holders based on this effect have been commonly used for contact free handling of samples coupled with a number of analytical techniques. In this study, a wall-free climate unit is presented, which allows the control of the environmental conditions of suspended samples. The insulation is based on a continuous cold/hot gas flow around the sample and thus does not require any additional isolation material. This provides a direct access to the levitated sample and circumvents any influence of the climate unit material to the running analyses. KW - Acoustic levition PY - 2012 DO - https://doi.org/10.1063/1.4705968 SN - 0034-6748 SN - 1089-7623 VL - 83 IS - 5 SP - 055101-1 EP - 055101-3 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-25881 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schlegel, M.C. A1 - Stroh, Julia A1 - Malaga, K. A1 - Meng, Birgit A1 - Panne, Ulrich A1 - Emmerling, Franziska T1 - Pathway of a damaging mechanism - Analyzing chloride attack by synchrotron based X-ray diffraction N2 - Typically, the changes of the phase compositions due to the chemical attack are studied in-situ only by chemical analysis or microscopy. In this study, the chloride transport and binding in the cement matrix in different cementitious materials was analyzed by synchrotron based X-ray diffraction (SyXRD) and energy dispersive X-ray spectroscopy (EDX). Sample materials consisting of cement paste were embedded in high concentrated sodium chloride solution over different time spans. Afterwards, the phase and chemical compositions were determined. The high spatial resolution and the information about the chloride distribution offer a detailed view of chloride binding in the cement matrix and allow the conclusions about the degradation mechanisms. The results are discussed related to the influence of different supplementary cementitious materials on the damaging mechanism. KW - Portland cement KW - In-situ KW - X-Ray diffraction KW - EDX KW - Durability KW - Chloride attack PY - 2015 DO - https://doi.org/10.1016/j.solidstatesciences.2015.03.021 SN - 1293-2558 SN - 1873-3085 VL - 44 SP - 45 EP - 54 PB - Elsevier Masson SAS CY - Amsterdam AN - OPUS4-33171 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Panne, Ulrich T1 - "Keine Dienstmagd" - Analytical Sciences in Action N2 - Analytical Sciences has developed from Ostwald’s “unentbehrlichen Dienstmagd” to a chemical discipline at the core of many of today’s fundamental and applied scientific problems and innovations. An atomic or molecular understanding of basic processes in chemistry, soft matter physics, materials and life science is enabled only through new analytical methods and instrumentation. Similar observations can be found for pressing sociopolitical conflicts of the future: A rational discussion of global climate change or new energy sources is only possible with reliable analytical results. Progress in Analytical Sciences is only possible if the underlying interdisciplinary character is acknowledged and valued. The talk will illustrate the scope of modern Analytical Science through examples from process analysis relevant to modern process intensification and industry 4.0 to bioanalysis and the use of synchrotron radiation to elucidate fundamental reactions materials. T2 - MChG Talk CY - Technische Universität München, Germany DA - 27.11.2018 KW - Analytical Sciences PY - 2018 AN - OPUS4-46940 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Giesen, C. A1 - Müller, Larissa A1 - Panne, Ulrich A1 - Jakubowski, Norbert T1 - History of inductively coupled plasma mass spectrometry-based immunoassays N2 - The analysis of biomolecules requires highly sensitive and selective detection methods capable of tolerating a complex, biological matrix. First applications of biomolecule detection by ICP-MS relied on the use of heteroelements as a label for quantification. However, the combination of immunoassays and ICP-MS facilitates multiparametric analyses through elemental tagging, and provides a powerful alternative to common bioanalytical methods. This approach extends the detection of biomarkers in clinical diagnosis, and has the potential to provide a deeper understanding of the investigated biological system. The results might lead to the detection of diseases at an early stage, or guide treatment plans. Immunoassays are well accepted and established for diagnostic purposes, albeit ICP-MS is scarcely applied for the detection of immune-based assays. However, the screening of biomarkers demands high throughput and multiplex/multiparametric techniques, considering the variety of analytes to be queried. Finally, quantitative information on the expression level of biomarkers is highly desirable to identify abnormalities in a given organism. Thus, it is the aim of this review to introduce the fundamentals, and to discuss the enormous strength of ICP-MS for the detection of different immunoassays on the basis of selected applications, with a special focus on LA-ICP-MS. KW - ICP-MS KW - LA-ICP-MS KW - Immunoassay KW - Elemental tagging KW - Multiplexing PY - 2012 DO - https://doi.org/10.1016/j.sab.2012.06.009 SN - 0584-8547 SN - 0038-6987 N1 - Geburtsname von Müller, Larissa: Wäntig, L. - Birth name of Müller, Larissa: Wäntig, L. VL - 76 SP - 27 EP - 39 PB - Elsevier CY - Amsterdam AN - OPUS4-27686 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schlegel, Moritz-Caspar A1 - Sarfraz, Adnan A1 - Müller, Urs A1 - Panne, Ulrich A1 - Emmerling, Franziska T1 - First seconds in a building's life - In situ synchrotron X-ray diffraction study of cement hydration on the millisecond timescale N2 - Setting cement: Highly dynamic hydration processes that occur during the first seconds of cement hydration were studied by time-resolved synchrotron X-ray diffraction. Polycarboxylate ether additives were found to influence the formation of the initial crystalline hydration products on a molecular level. KW - Cement hydration KW - Colloidal suspensions KW - In situ analysis KW - X-ray diffraction KW - SyXRD KW - High resolution KW - In-situ PY - 2012 DO - https://doi.org/10.1002/anie.201200993 SN - 1433-7851 SN - 1521-3773 SN - 0570-0833 VL - 51 IS - 20 SP - 4993 EP - 4996 PB - Wiley-VCH CY - Weinheim AN - OPUS4-26287 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schlegel, Moritz-Caspar A1 - Müller, Urs A1 - Malaga, Katarina A1 - Panne, Ulrich A1 - Emmerling, Franziska T1 - Spatially resolved investigation of complex multi-phase systems using muXRF, SEM-EDX and high resolution SyXRD N2 - Spatially resolved analysis of complex multi-phase systems can be validated through different analytical methods. This study compares investigations by scanning electron microscopy coupled with energy dispersive X-ray fluorescence analysis and high resolution X-ray diffraction. The studied sulfate attacked cement paste containing fly ashes consists of different interacting crystalline and amorphous phases. The complementary methods revealed in detail changes in phase composition due to the chemical attack. The advantages and disadvantages of both methods are discussed and suggestions are given for combining them with additional methods to maximize the information content. KW - EDX-SEM KW - SyXRD KW - Spatial investigations KW - Comparison KW - High resolution KW - Cement paste KW - Sulfate attack KW - Damaging mechanism PY - 2013 DO - https://doi.org/10.1016/j.cemconcomp.2012.08.018 SN - 0958-9465 SN - 1873-393X VL - 37 SP - 241 EP - 245 PB - Elsevier Ltd. CY - Barking, Essex AN - OPUS4-29111 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Sarfraz, Adnan A1 - Simo, A. A1 - Fenger, R. A1 - Christen, W. A1 - Rademann, K. A1 - Panne, Ulrich A1 - Emmerling, Franziska T1 - Morphological diversity of caffeine on surfaces: needles and hexagons N2 - A systematic crystal morphology study on the pharmaceutical model compound caffeine has been conducted on different surfaces: silicon, silver, soda lime glass, and silver subsurface ion-exchanged soda-lime silicate (SIMO) glasses. The morphology of the solid caffeine deposits has been investigated using environmental scanning electron microscopy (ESEM), atomic force microscopy (AFM), and X-ray diffraction (XRD). Needle-shaped caffeine crystals have been observed by drop-casting and also by applying the rapid expansion of supercritical solutions (RESS) technique using supercritical carbon dioxide. The aspect ratio of the crystalline needles typically vary between 10 and 100, but have been observed as large as 500. The XRD data of the RESS products indicate unambiguously the presence of the thermodynamically most stable polymorph of caffeine known as the β-form. Under defined conditions we observe a unique, surface-mediated morphology for caffeine crystals with nearly perfect hexagonal shape. The relative fraction of the hexagons was seen to strongly increase especially when SIMO glasses were used. These hexagons have a distinct upper size limit depending on the solvent and substrate being used. The size distribution analysis of the hexagons yielded an average perimeter of typically 10 µm. The mechanism of the formation process of this new hexagonal motif is explained in terms of the spinodal dewetting of the thin film of caffeine solution on the surface. KW - Caffeine KW - Silicon KW - Silver KW - Ion exchanged soda lime silicate glass KW - ESEM KW - AFM KW - X-ray diffraction KW - RESS KW - Carbon dioxide KW - Supercritical fluids PY - 2012 DO - https://doi.org/10.1021/cg101358q SN - 1528-7483 VL - 12 IS - 2 SP - 583 EP - 588 PB - American Chemical Society CY - Washington, DC, USA AN - OPUS4-25457 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schlegel, Moritz-Caspar A1 - Müller, Urs A1 - Panne, Ulrich A1 - Emmerling, Franziska A1 - Meng, Birgit ED - Rogge, A. ED - Meng, B. T1 - Neue Wege in der Zementanalytik - Hochaufgelöste in-situ Sy-XRD T2 - 52. DAfStb-Forschungskolloquium CY - Berlin, Deutschland DA - 2011-11-07 PY - 2011 SN - 978-3-9814281-0-0 SP - 18 EP - 24 PB - BAM Bundesanstalt für Materialforschung und -prüfung CY - Berlin AN - OPUS4-25197 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hoffmann, Holger A1 - Baldofski, Stefanie A1 - Hoffmann, Kristin A1 - Flemig, Sabine A1 - Silva, C. P. A1 - Esteves, V. I. A1 - Emmerling, Franziska A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - Structural considerations on the selectivity of an immunoassay for sulfamethoxazole N2 - Sulfamethoxazol (SMX),a sulfonamide, is a widely used bacteriostatic antibiotic and therefore a promising marker for the entry of anthropogenic Pollution in the environment. SMX is frequently found in wastewater and surface water. This study presents the production of high affinity and selective polyclonal antibodies for SMX and the development and Evaluation of a direct competitive enzyme-linked immunosorbent assay(ELISA)for the quantification of SMX in environmental watersamples. The crystal structures of the cross-reacting compounds sulfamethizole, N4-acetyl-SMX andsuccinimidyl-SMX were determined by x-ray diffraction aiming to explain their high cross-reactivity. These crystal structures are described for the first time. The quantification range of the ELISA is 0.82–63 µg/L. To verify our results, the SMX concentration in 20 environmental samples,including wastewater and surfacewater,was determined by ELISA and tandem mass spectrometry(MS/MS).A good Agreement of the measured SMX concentrations was found with average recoveries of 97–113%for the results of ELISA compared to LC-MS/MS. KW - X-Ray diffraction KW - Sulfamethoxazole KW - ELISA KW - LC-MS/MS PY - 2016 DO - https://doi.org/10.1016/j.talanta.2016.05.049 SN - 0039-9140 SN - 1873-3573 IS - 158 SP - 198 EP - 207 PB - Elsevier B.V. CY - Amsterdam, Netherlands AN - OPUS4-36676 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wolf, S. E. A1 - Müller, L. A1 - Barrea, R. A1 - Kampf, C.J. A1 - Leiterer, Jork A1 - Panne, Ulrich A1 - Hoffmann, T. A1 - Emmerling, Franziska A1 - Tremel, W. T1 - Carbonate-coordinated metal complexes precede the formation of liquid amorphous mineral emulsions of divalent metal carbonates N2 - During the mineralisation of metal carbonates MCO3 (M = Ca, Sr, Ba, Mn, Cd, Pb) liquid-like amorphous intermediates emerge. These intermediates that form via a liquid/liquid phase separation behave like a classical emulsion and are stabilized electrostatically. The occurrence of these intermediates is attributed to the formation of highly hydrated networks whose stability is mainly based on weak interactions and the variability of the metal-containing pre-critical clusters. Their existence and compositional freedom are evidenced by electrospray ionization mass spectrometry (ESI-MS). Liquid intermediates in non-classical crystallisation pathways seem to be more common than assumed. PY - 2011 DO - https://doi.org/10.1039/c0nr00761g SN - 2040-3364 SN - 2040-3372 IS - 3 SP - 1158 EP - 1165 PB - RSC Publ. CY - Cambridge AN - OPUS4-23355 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Klimakow, Maria A1 - Leiterer, Jork A1 - Kneipp, Janina A1 - Rössler, E. A1 - Panne, Ulrich A1 - Rademann, K. A1 - Emmerling, Franziska T1 - Combined synchrotron XRD/Raman measurements: In situ identification of polymorphic transitions during crystallization processes N2 - A combination of two analytical methods, time-resolved X-ray diffraction (XRD) and Raman spectroscopy, is presented as a novel tool for crystallization studies. An acoustic levitator was employed as sample environment. This setup enables the acquisition of XRD and Raman data in situ simultaneously within a 20 s period and hence permits investigation of polymorphic phase transitions during the crystallization process in different solvents (methanol, ethanol, acetone, dichloromethane, acetonitrile). These real time measurements allow the determination of the phase content from the onset of the first crystalline molecular assemblies to the stable system. To evaluate the capability of this approach, the setup was applied to elucidate the crystallization process of the polymorphic compound nifedipine. The results indicate the existence of solvent-dependent transient phases during the crystallization process. The quality of the data allowed the assignment of the lattice constants of the hitherto unknown crystal structure of the β-polymorph. KW - Synchrotron radiation KW - XRD KW - Raman spectroscopy KW - Polymorphism KW - Crystallization KW - Acoustic levitation KW - Nifedipine PY - 2010 DO - https://doi.org/10.1021/la100540q SN - 0743-7463 SN - 1520-5827 VL - 26 IS - 13 SP - 11233 EP - 11237 PB - American Chemical Society CY - Washington, DC AN - OPUS4-21396 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Leiterer, Jork A1 - Leitenberger, W. A1 - Emmerling, Franziska A1 - Thünemann, Andreas A1 - Panne, Ulrich T1 - The use of an acoustic levitator to follow crystallization in small droplets by energy-dispersive X-ray diffraction N2 - For the investigation of small sample volumes, the use of an acoustic levitator was tested as a `sample holder' for hovering droplets in a synchrotron beam. It might be advantageous to use levitated droplets instead of samples confined in solid holders, especially for the study of crystallization processes where the influence of containing walls has to be minimized. In a first experiment, the crystallization of sodium chloride in a small droplet of aqueous solution has been followed with a time resolution of 30 s. The collected diffraction peaks are compared with data in the ICSD database. KW - EDXD KW - Noncontact measurement technique KW - X-ray-scattering KW - Synchrotron-radiation KW - Acoustic levitation PY - 2006 DO - https://doi.org/10.1107/S0021889806024915 SN - 0021-8898 SN - 1600-5767 VL - 39 IS - 5 SP - 771 EP - 773 PB - Blackwell CY - Oxford AN - OPUS4-13516 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Balski, Matthias A1 - Emmerling, Franziska A1 - Kipphardt, Heinrich A1 - Panne, Ulrich T1 - Determination of boron in silicon without use of additional complexing agents N2 - Methods for the determination of boron in various matrices described in the literature usually employ complexing agents like mannitol to retain the volatile boron species during matrix evaporation steps. However, also relatively high boron recoveries from silicon containing samples have been reported when no complexing agents were added to the digestion acids. The mechanism behind this matrix-dependant recovery has been investigated by studying the boron recovery in the analysis of solar grade silicon. It was found that the NH4+ ion formed by the reduction of nitric acid during sample digestion is responsible for the higher recovery of boron, which leads to a possible analysis method without the use of complexing agents if the sample preparation procedure is carefully optimized. KW - Boron KW - Complexing agents KW - Matrix evaporation KW - Sample enrichment PY - 2014 DO - https://doi.org/10.1039/c4ay00410h SN - 1759-9660 SN - 1759-9679 VL - 6 IS - 12 SP - 4003 EP - 4008 PB - RSC Publ. CY - Cambridge AN - OPUS4-30956 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Sötebier, Carina A1 - Bierkandt, Frank A1 - Rades, Steffi A1 - Jakubowski, Norbert A1 - Panne, Ulrich A1 - Weidner, Steffen T1 - Sample loss in asymmetric flow field-flow fractionation coupled to inductively coupled plasma-mass spectrometry of silver nanoparticles N2 - In this work, sample losses of silver nanoparticles (Ag NPs) in asymmetrical flow field-flow fractionation (AF4) have been systematically investigated with the main focus on instrumental conditions like focusing and cross-flow parameters as well as sample concentration and buffer composition. Special attention was drawn to the AF4 membrane. For monitoring possible silver depositions on the membrane, imaging laser ablation coupled to inductively coupled plasma mass spectrometry (LA-ICP-MS) was used. Our results show that the sample residue on the membrane was below 0.6% of the total injected amount and therefore could be almost completely avoided at low sample concentrations and optimized conditions. By investigation of the AF4 flows using inductively coupled plasma mass spectrometry (ICP-MS), we found the recovery rate in the detector flow under optimized conditions to be nearly 90%, while the cross-flow, slot-outlet flow and purge flow showed negligible amounts of under 0.5%. The analysis of an aqueous ionic Ag standard solution resulted in recovery rates of over 6% and the ionic Ag content in the sample was found to be nearly 8%. Therefore, we were able to indicate the ionic Ag content as the most important source of sample loss in this study. KW - Asymmetric flow filed-flow fractionation KW - ICP-MS KW - Nanoparticles KW - Sample loss KW - Quantification PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-336171 DO - https://doi.org/10.1039/c5ja00297d SN - 0267-9477 SN - 1364-5544 VL - 30 IS - 10 SP - 2214 EP - 2222 PB - Royal Society of Chemistry CY - London AN - OPUS4-33617 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Seifert, Stephan A1 - Weidner, Steffen A1 - Panne, Ulrich A1 - Kneipp, Janina T1 - Taxonomic relationship of pollen from MALDI TOF MS data using multivariate statistics N2 - Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has been suggested as a promising tool for the investigation of pollen, but the usefulness of this approach for classification and identification of pollen species has to be proven by an application to samples of varying taxonomic relations. KW - MALDI mass spectrometry KW - Pollen KW - Multivariate statistics PY - 2015 DO - https://doi.org/10.1002/rcm.7207 SN - 0951-4198 SN - 1097-0231 VL - 29 SP - 1145 EP - 1154 PB - Wiley CY - Chichester AN - OPUS4-35296 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Leiterer, Jork A1 - Panne, Ulrich A1 - Thünemann, Andreas A1 - Weidner, Steffen T1 - Container-less polymerization in acoustically levitated droplets: an analytical study by GPC and MALDI-TOF mass spectrometry N2 - Molecular masses and end groups of polystyrene (PS) formed in a novel container-less polymerization strategy, based on levitated droplets in an acoustic trap, were determined by Gel Permeation Chromatography (GPC) and Matrix-assisted Laser Desorption/Ionization Time of Flight Mass spectrometry (MALDI-TOF MS). KW - Ultraschallfalle KW - MALDI Massenspektrometrie KW - Polymerisation PY - 2011 DO - https://doi.org/10.1039/c0ay00390e SN - 1759-9660 SN - 1759-9679 VL - 3 IS - 1 SP - 70 EP - 73 PB - RSC Publ. CY - Cambridge AN - OPUS4-23655 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Epping, Ruben A1 - Panne, Ulrich A1 - Falkenhagen, Jana T1 - Power of ultra performance liquid chromatography/electrospray ionization-MS reconstructed ion chromatograms in the characterization of small differences in polymer microstructure N2 - From simple homopolymers to functionalized, 3-dimensional structured copolymers, the complexity of polymeric materials has become more and more sophisticated. With new applications for instance in the semiconductor or pharmaceutical industry, the requirements for the characterization have risen with the complexity of the used polymers. For each additional distribution, an additional dimension in analysis is needed. Small, often isomeric heterogeneities in topology or microstructure can usually not be simply separated chromatographically or distinguished by any common detector, but affect the properties of materials significantly. For a drug delivery system for example, the degree of branching and branching distribution is crucial for the formation of micelles. Instead of a complicated, time consuming and/or expensive 2d-chromatography or ion mobility spectrometry (IMS) method, that also has its limitations, in this work a simple approach using size exclusion chromatography (SEC) coupled with electrospray ionization mass spectrometry (ESI) is proposed. The online coupling allows the analysis of reconstructed ion chromatograms (RIC) of each degree of polymerization. While a complete separation often cannot be achieved, the derived retention times and peak widths lead to information on the existence and dispersity of heterogeneities. Although some microstructural heterogeneities like short chain branching can for large polymers be characterized with methods such as light scattering, for oligomers where the heterogeneities just start to form and their influence is at the maximum, they are inaccessible with these methods. It is also shown, that with a proper calibration even quantitative information can be obtained. This method is suitable to detect small differences in e. g. branching, 3d-structure, monomer sequence or tacticity and could potentially be used in routine analysis to quickly determine deviations. KW - Polymer KW - Microstructure KW - UPLC KW - ESI-TOF-MS KW - Reconstructed ion chromatograms PY - 2018 DO - https://doi.org/10.1021/acs.analchem.7b05214 SN - 0003-2700 SN - 1520-6882 VL - 90 IS - 5 SP - 3467 EP - 3474 PB - ACS Publ. CY - Washington, DC AN - OPUS4-44423 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weidner, Steffen A1 - Knappe, Patrick A1 - Panne, Ulrich T1 - MALDI-TOF imaging mass spectrometry of artifacts in 'dried droplet' polymer samples N2 - Matrix-assisted laser desorption/ionization-timeof-flight (MALDI-TOF) imaging of polystyrenes with various molecular masses was applied to study spatial molecular mass distribution of polymers in sample spots prepared by the 'dried droplet' method. When different solvents and target surfaces were examined, a segregation of single homologous polymers was observed depending upon the evaporation rate of the solvent. For the observed Patterns left by the evaporating droplet, a hypothesis is offered taking into account different hydrodynamic interactions and diffusion. The results illustrate that spot preparation using the conventionally 'dried droplet' method is prone to artifacts and should be avoided for reliable and reproducible MALDI mass spectrometry experiments with regards to the Determination of molecular masses and mass distributions. KW - MALDI KW - Mass spectrometry imaging KW - Polymer KW - Droplet PY - 2011 DO - https://doi.org/10.1007/s00216-011-4773-1 SN - 1618-2642 SN - 1618-2650 VL - 401 IS - 1 SP - 127 EP - 134 PB - Springer CY - Berlin AN - OPUS4-24538 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gabriel, Stefan A1 - Steinhoff, R.F. A1 - Pabst, M. A1 - Schwarzinger, C. A1 - Zenobi, R. A1 - Panne, Ulrich A1 - Weidner, Steffen T1 - Improved analysis of ultra-high molecular mass polystyrenes in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using DCTB matrix and caesium salts N2 - Rationale The ionization of polystyrenes in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is typically achieved by the use of silver salts. Since silver salts can cause severe problems, such as cluster formation, fragmentation of polymer chains and end group cleavage, their substitution by alkali salts is highly desirable. Methods The influence of various cations (Ag+, Cs+ and Rb+) on the MALDI process of polystyrene (PS) mixtures and high mass polystyrenes was examined. The sample preparation was kept as straightforward as possible. Consequently, no recrystallization or other cleaning procedures were applied. Results The investigation of a polystyrene mixture showed that higher molecular polystyrenes could be more easily ionized using caesium, rather than rubidium or silver salts. In combination with the use of DCTB as matrix a high-mass polymer analysis could be achieved, which was demonstrated by the detection of a 1.1 MDa PS. Conclusions A fast, simple and robust MALDI sample preparation method for the analysis of ultra-high molecular weight polystyrenes based on the use of DCTB and caesium salts has been presented. The suitability of the presented method has been validated by using different mass spectrometers and detectors. KW - MALDI KW - Mega-dalton KW - Ionization KW - Caesium KW - Polystyrene KW - DCTB PY - 2015 UR - http://onlinelibrary.wiley.com/doi/10.1002/rcm.7197/full DO - https://doi.org/10.1002/rcm.7197 SN - 0951-4198 SN - 1097-0231 VL - 29 IS - 11 SP - 1039 EP - 1046 PB - Wiley CY - Chichester AN - OPUS4-33191 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Krause, Benjamin Christoph A1 - Seifert, Stephan A1 - Panne, Ulrich A1 - Kneipp, Janina A1 - Weidner, Steffen T1 - Matrix-assisted laser desorption/ionization mass spectrometric investigation of pollen and their classification by multivariate statistics N2 - RATIONALE A fast and reliable online identification of pollen is not yet available. The identification of pollen is based mainly on the evaluation of morphological data obtained by microscopic methods. METHODS Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-TOF MS) was applied to the analysis of extracts and milled pollen samples. The obtained MALDI data were explored for characteristic peak patterns which could be subjected to a multivariate statistical analysis. RESULTS Two sample preparation methods are presented, which require only minimal or no chemical extraction of the pollen. MALDI pollen spectra could be recorded showing various peak patterns. A multivariate statistics approach allowed the classification of pollen into clusters indicating similarities and differences between various species. CONCLUSIONS These results demonstrate the potential and the reliability of MALDI-TOF MS for the identification and, in combination with multivariate statistics, also for the classification of pollen. KW - MALDI TOF mass spectrometry KW - Pollen KW - Multivariate statistics PY - 2012 DO - https://doi.org/10.1002/rcm.6202 SN - 0951-4198 SN - 1097-0231 VL - 26 IS - 9 SP - 1032 EP - 1038 PB - Wiley CY - Chichester AN - OPUS4-25648 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Scholz, Philipp A1 - Wachtendorf, Volker A1 - Panne, Ulrich A1 - Weidner, Steffen ED - Scholz, Philipp T1 - Degradation of MDI-based polyether and polyester-polyurethanes in various environments - Effects on molecular mass and crosslinking N2 - Size-exclusion chromatography (SEC) was used to monitor changes of the molecular masses of thermoplastic polyether – and polyester urethane (TPU) exposed to thermal, hydrolytic, and photo-oxidative (UV) Degradation conditions for several days. The thermal treatment was performed at elevated temperatures (100–200 °C) under oxidative (air) as well as non-oxidative (nitrogen) conditions to evaluate the specific influence of oxygen on the degradation. At higher temperatures (≥175 °C) a fast decrease of the molecular masses of both PU accompanied by a high degree of crosslinking was found. At lower temperatures (≤150 °C) the polymers remained widely unaffected by thermal degradation within the investigated degradation interval of up to two weeks. Surprisingly, the influence of oxygen (air) was found to be less distinct. In contrast to that, UV treatment at 25 °C at less than 10% rel. humidity (RH) resulted in a fast crosslinking, whereas the molecular masses of both PU decreased slower than for thermal treatments. The depth of penetration of the UV radiation was estimated using 3D printed PU samples with different thicknesses. Hydrolysis based degradation effects were less significant. Only slight molecular mass changes were detected at temperatures ≤80 °C within a time span of 14 days, while no crosslinking could be measured. Considering the degradation results at the investigated exposure parameters, it could be shown that esterbased PU in general exhibits a significant higher stability compared to ether-based materials. KW - Polyurethane KW - Thermal degradation KW - UV degradation KW - Molecular masses KW - Crosslinking PY - 2019 UR - https://www.sciencedirect.com/science/article/pii/S0142941819302363 DO - https://doi.org/10.1016/j.polymertesting.2019.04.028 SN - 0142-9418 VL - 77 SP - 105881, 1 EP - 12 PB - Elsevier CY - Amsterdam AN - OPUS4-48619 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hoffmann, Holger A1 - Baldofski, Stefanie A1 - Hoffmann, Kristin A1 - Flemig, Sabine A1 - Silva, C. P. A1 - Esteves, V. I. A1 - Emmerling, Franziska A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - Structural considerations on the selectivity of an immunoassay for sulfamethoxazole N2 - Sulfamethoxazol (SMX),a sulfonamide, is a widely used bacteriostatic antibiotic and therefore a promising marker for the entry of anthropogenic Pollution in the environment. SMX is frequently found in wastewater and surface water. This study presents the production of high affinity and selective polyclonal antibodies for SMX and the development and Evaluation of a direct competitive enzyme-linked immunosorbent assay(ELISA)for the quantification of SMX in environmental watersamples. The crystal structures of the cross-reacting compounds sulfamethizole, N4-acetyl-SMX andsuccinimidyl-SMX were determined by x-ray diffraction aiming to explain their high cross-reactivity. These crystal structures are described for the first time. The quantification range of the ELISA is 0.82–63 µg/L. To verify our results, the SMX concentration in 20 environmental samples,including wastewater and surfacewater,was determined by ELISA and tandem mass spectrometry(MS/MS).A good Agreement of the measured SMX concentrations was found with average recoveries of 97–113%for the results of ELISA compared to LC-MS/MS. KW - X-Ray diffraction KW - ELISA KW - LC-MS/MS KW - Sulfamethoxazole PY - 2016 DO - https://doi.org/10.1016/j.talanta.2016.05.049 SN - 0039-9140 SN - 1873-3573 IS - 158 SP - 198 EP - 207 PB - Elsevier B.V. CY - Amsterdam, Netherlands AN - OPUS4-38530 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schlegel, Moritz-Caspar A1 - Müller, Urs A1 - Panne, Ulrich A1 - Emmerling, Franziska T1 - Deciphering the sulfate attack of cementitious materials by high-resolution micro-x-ray diffraction N2 - The durability of cementitious materials depends, among others, on their resistance against chemical attack during the service life of a building. Here, we present an approach to analyze changes in the phase composition due to chemical attack in the form of sulfate ingress within the microstructure. Micro-X-ray (µX-ray) diffraction using synchrotron radiation in Debye–Scherrer (transmission) geometry allowed a spatial resolution of 10 µm. Phase transformations in the wake of damaging processes were observed in a detailed high-resolution imaging study. In comparison, samples containing supplementary cementitious materials were investigated and used to reconstruct the influence of different degeneration processes in detail. Additionally, reaction fronts within the bulk were localized by micro-X-ray fluorescence analysis. The experimental setup provided the possibility for analyzing the phase assemblage of a given sample without destroying the microstructure. The specimens for phase analysis are thick sections of the primary material and can be used for further microscopic analysis of the microstructure and microchemistry, e.g., scanning electron microscopy–energy-dispersive X-ray spectroscopy (SEM–EDX) or Raman spectroscopy. PY - 2011 DO - https://doi.org/10.1021/ac200181g SN - 0003-2700 SN - 1520-6882 VL - 83 IS - 10 SP - 3744 EP - 3749 PB - American Chemical Society CY - Washington, DC AN - OPUS4-23669 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schlegel, Moritz-Caspar A1 - Sarfraz, Adnan A1 - Müller, Urs A1 - Panne, Ulrich A1 - Emmerling, Franziska T1 - Erste Sekunden im Leben eines Bauwerks - In-situ-Synchrotron-Röntgenbeugungsuntersuchungen der Zementhydratation mit Millisekunden-Auflösung N2 - Höchst dynamische Hydratationsprozesse in den ersten Sekunden bei der Entstehung eines Bauwerkes lassen sich mithilfe von Synchrotron-Röntgenbeugung mit einer sehr hohen Zeitauflösung nachverfolgen. Der Schwerpunkt lag dabei auf der Beeinflussung der Bildung erster kristalliner Hydratationsprodukte während des Frühstadiums der Zementhydratation. KW - SyXRD KW - High resolution KW - In-situ KW - Colloidal suspension KW - Cement hydration KW - In-situ-Analyse KW - Kolloidale Suspensionen KW - Röntgenbeugung KW - Zementhydratation PY - 2012 DO - https://doi.org/10.1002/ange.201200993 SN - 0044-8249 SN - 0932-2140 SN - 1521-3757 VL - 124 IS - 20 SP - 5078 EP - 5081 PB - Wiley-VCH CY - Weinheim AN - OPUS4-26284 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Epping, Ruben A1 - Falkenhagen, Jana A1 - Panne, Ulrich A1 - Hiller, W. A1 - Gruendling, T. A1 - Staal, B. A1 - Lang, C. A1 - Lamprou, A. T1 - Simultaneous characterization of poly(acrylic acid) andpolysaccharide polymers and copolymers N2 - Copolymer products that result from grafting acrylic acid and other hydrophilicmonomers onto polysaccharides have recently gained significant interest in researchand industry. Originating from renewable sources, these biodegradable, low toxicity,and polar copolymer products exhibit potential to replace polymers from fossil sourcesin several applications and industries. The methods usually employed to character-ize these copolymers are, however, quite limited, especially for the measurement ofbulk properties. With more sophisticated applications, for example, in pharmaceu-tics requiring a more detailed analysis of the chemical structure, we describe a newapproach for this kind of complex polymers. Our approach utilizes chromatographyin combination with several detection methods to separate and characterize reactionproducts of the copolymerization of acrylic acid and chemically hydrolyzed starch.These samples consisted of a mixture of homopolymer poly (acrylic acid), homopoly-mer hydrolyzed starch, and – in a lower amount – the formed copolymers. Several chro-matographic methods exist that are capable of characterizing either poly (acrylic acid)or hydrolyzed starch. In contrast, our approach offers simultaneous characterization ofboth polymers. The combination of LC and UV/RI offered insight into the compositionand copolymer content of the samples. Size exclusion chromatography experimentsrevealed the molar mass distribution of homopolymers and copolymers. FTIR inves-tigations confirmed the formation of copolymers while ESI-MS gave more details onthe end groups of hydrolyzed starches and poly (acrylic acids). Evidence of copolymerstructures was obtained through NMR measurements. Finally, two-dimensional chro-matography led to the separation of the copolymers from both homopolymers as wellas the additional separation of sodium clusters. The methods described in this work area powerful toolset to characterize copolymerization products of hydrolyzed starch andpoly(acrylic acid). Together, our approach successfully correlates the physicochemicalproperties of such complex mixtures with their actual composition. KW - 2D chromatography KW - LC-MS KW - SEC KW - Renewable copolymers KW - Grafting PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-508873 DO - https://doi.org/10.1002/ansa.202000044 SP - 1 EP - 12 PB - Wiley-VCH Verlag-GmbH&Co. KGaA CY - Weinheim AN - OPUS4-50887 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gabriel, Stefan A1 - Pfeifer, Dietmar A1 - Schwarzinger, C. A1 - Panne, Ulrich A1 - Weidner, Steffen T1 - Matrix-assisted laser desorption/ionization time-of-flight mass spectrometric imaging of synthetic polymer sample spots prepared using ionic liquid matrices N2 - RATIONALE Polymer sample spots for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) prepared by the dried-droplet method often reveal ring formation accompanied by possible segregation of matrix and sample molecules as well as of the polymer homologs itself. Since the majority of sample spots are prepared by this simple and fast method, a matrix or sample preparation method that excludes such segregation has to be found. METHODS Three different ionic liquid matrices based on conventionally used aromatic compounds for MALDI-TOF MS were prepared. The formation of ionic liquids was proven by 1H NMR spectroscopy. MALDI-Imaging mass spectrometry was applied to monitor the homogeneity. RESULTS Our results show a superior sample spot homogeneity using ionic liquid matrices. Spots could be sampled several times without visible differences in the mass spectra. A frequently observed loss of matrix in the mass spectrometer vacuum was not observed. The necessary laser irradiance was reduced, which resulted in less polymer fragmentation. CONCLUSIONS Ionic liquid matrices can be used to overcome segregation, a typical drawback of conventional MALDI dried-droplet preparations. Homogeneous sample spots are easy to prepare, stable in the MS vacuum and, thereby, improve the reproducibility of MALDI. PY - 2014 DO - https://doi.org/10.1002/rcm.6810 SN - 0951-4198 SN - 1097-0231 VL - 28 IS - 5 SP - 489 EP - 498 PB - Wiley CY - Chichester AN - OPUS4-30267 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Sötebier, Carina A. A1 - Weidner, Steffen A1 - Jakubowski, Norbert A1 - Panne, Ulrich A1 - Bettmer, J. T1 - Separation and quantification of silver nanoparticles and silver ions using reversed phase high performance liquid chromatography coupled to inductively coupled plasma mass spectrometry in combination with isotope dilution analysis N2 - A reversed phase high performance liquid chromatography coupled to an inductively coupled Plasma mass spectrometer (HPLC–ICP-MS) approach in combination with isotope dilution analysis (IDA) for the separation and parallel quantification of nanostructured and ionic silver (Ag) is presented. The main Focus of this work was the determination of the ionic Ag concentration. For a sufficient stabilization of the Ions without dissolving the nanoparticles (NPs), the eluent had to be initially optimized. The determined Ag ion concentration was in a good agreement with results obtained using ultrafiltration. Further, the mechanism of the NP separation in the HPLC column was investigated. Typical size exclusion effects were found by comparing results from columns with different pore sizes. Since the recovery rates decreased with increasing Ag NP size and large Ag NPs did not elute from the column, additional interactions of the particles with the stationary phase were assumed. Our results reveal that the presented method is not only applicable to Ag NPs, but also to gold and polystyrene NPs. Finally, IDA-HPLC-ICP-MS experiments in single particle mode were performed to determine the particle cut-off size. The comparison with conventional spICP-MS experiments resulted in a similar diameter and particle size distribution. KW - ICP-MS KW - Silver nanoparticles KW - Speciation KW - High performance liquid chromatography KW - Isotope dilution analysis PY - 2016 DO - https://doi.org/10.1016/j.chroma.2016.09.028 SN - 0021-9673 VL - 1468 SP - 102 EP - 108 AN - OPUS4-37652 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Panne, Ulrich T1 - Polymerwissenschaften@BAM - Sicherheit macht Märkte N2 - Die Bundesanstalt für Materialforschung und -prüfung (BAM) ist eine Ressortforschungseinrichtung, die zum Schutz von Mensch, Umwelt und Sachgüter, forscht, prüft und berät. Im Fokus aller Tätigkeiten in der Materialwissenschaft, der Werkstofftechnik und der Chemie steht dabei die technische Sicherheit von Produkten und Prozessen. Dazu werden Substanzen, Werkstoffe, Bauteile, Komponenten und Anlagen sowie natürliche und technische Systeme erforscht und auf sicheren Umgang oder Betrieb geprüft und bewertet. Schwerpunkt des Vortrages sind multimodale Polymeranalytik, nanoskalige Sensormaterialien und die Charakterisierung von technischen Eigenschaften von Polymeren sowie ihre Alterung und Umweltrelevanz. T2 - Institutsvortrag CY - Fraunhofer IAP, Potsdam, Germany DA - 18.05.2018 KW - Polymerwissenschaften PY - 2018 AN - OPUS4-45243 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Sötebier, Carina A1 - Weidner, Steffen A1 - Jakubowski, Norbert A1 - Panne, Ulrich A1 - Bettmer, J. T1 - Separation and quantification of silver nanoparticles and silver ions using reversed phase high performance liquid chromatography coupled to inductively coupled plasma mass spectrometry in combination with isotope dilution analysis N2 - A reversed phase high performance liquid chromatography coupled to an inductively coupled plasma mass spectrometer (HPLC-ICP-MS) approach in combination with isotope dilution analysis (IDA) for the separation and parallel quantification of nanostructured and ionic silver (Ag) is presented. The main focus of this work was the determination of the ionic Ag concentration. For a sufficient stabilization of the ions without dissolving the nanoparticles (NPs), the eluent had to be initially optimized. The determined Ag ion concentration was in a good agreement with results obtained using ultrafiltration. Further, the mechanism of the NP separation in the HPLC column was investigated. Typical size exclusion effects were found by comparing results from columns with different pore sizes. Since the recovery rates decreased with increasing Ag NP size and large Ag NPs did not elute from the column, additional interactions of the particles with the stationary phase were assumed. Our results reveal that the presented method is not only applicable to Ag NPs, but also to gold and polystyrene NPs. Finally, IDA-HPLC-ICP-MS experiments in single particle mode were performed to determine the particle cut-off size. The comparison with conventional spICP-MS experiments resulted in a similar diameter and particle size distribution. KW - ICP-MS KW - Silver nanoparticles KW - HPLC KW - Isotope dilution analysis KW - Field flow fractionation KW - Toxicology PY - 2016 DO - https://doi.org/10.1016/j.chroma.2016.09.028 SN - 0021-9673 VL - 1468 SP - 102 EP - 108 PB - Elsevier B.V. AN - OPUS4-38642 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Epping, Ruben A1 - Panne, Ulrich A1 - Falkenhagen, Jana T1 - Critical conditions for liquid chromatography of statistical copolymers: Functionality type and composition distribution characterization by UP-LCCC/ESI-MS N2 - Statistical ethylene oxide (EO) and propylene oxide (PO) copolymers of different monomer compositions and different average molar masses additionally containing two kinds of end groups (FTD) were investigated by ultra high pressure liquid chromatography under critical conditions (UP-LCCC) combined with electrospray ionization time-of flight mass spectrometry (ESI-TOFMS). Theoretical predictions of the existence of a critical adsorption point (CPA) for statistical copolymers with a given chemical and sequence distribution1 could be studied and confirmed. A fundamentally new approach to determine these critical conditions in a copolymer, alongside the inevitable chemical composition distribution (CCD), with mass spectrometric detection, is described. The shift of the critical eluent composition with the monomer composition of the polymers was determined. Due to the broad molar mass distribution (MMD) and the presumed existence of different end group functionalities as well as monomer sequence distribution (MSD), Gradient separation only by CCD was not possible. Therefore, isocratic separation conditions at the CPA of definite CCD fractions were developed. Although the various present distributions partly superimposed the separation process, the goal of separation by end group functionality was still achieved on the basis of the additional dimension of ESI-TOF-MS. The existence of HO-H besides the desired allylO-H end group functionalities was confirmed and their amount estimated. Furthermore, indications for a MSD were found by UPLC/MS/MS measurements. This approach offers for the first time the possibility to obtain a fingerprint of a broad distributed statistical copolymer including MMD, FTD, CCD, and MSD. KW - Polymer KW - Liquid chromatography at critical conditions KW - ESI-TOF-MS PY - 2017 DO - https://doi.org/10.1021/acs.analchem.6b04064 SN - 0003-2700 SN - 1520-6882 VL - 89 IS - 3 SP - 1778 EP - 1786 AN - OPUS4-39240 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - You, Zengchao A1 - Nirmalananthan-Budau, Nithiya A1 - Resch-Genger, Ute A1 - Panne, Ulrich A1 - Weidner, Steffen T1 - Separation of polystyrene nanoparticles bearing different carboxyl group densities and functional groups quantification with capillary electrophoresis and asymmetrical flow field flow fractionation N2 - Two sets of polystyrene nanoparticles (PSNPs) with comparable core sizes but different carboxyl group densities were made and separated using asymmetric flow field flow fractionation (AF4), capillary electrophoresis (CE), and the off-line hyphenation of both methods. Our results revealed the significant potential of two-dimensional off-line AF4-CE hyphenation to improve the separation and demonstrated for the first time, the applicability of CE to determine the functional group density of nanoparticles (NPs). Compared to the result acquired with conductometric titration, the result obtained with synthesized 100 nm sized PSNPs revealed only a slight deviation of 1.7%. Commercial 100 nm sized PSNPs yielded a deviation of 4.6 %. For 60 nm sized PSNPs, a larger deviation of 10.6 % between both methods was observed, which is attributed to the lower separation resolution. KW - Nanoparticle KW - A4F KW - Capillary electrophoresis KW - Carboxyl group PY - 2020 DO - https://doi.org/10.1016/j.chroma.2020.461392 VL - 1626 SP - 461392 PB - Elsevier B.V. AN - OPUS4-51080 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gabriel, Stefan A1 - Schwarzinger, C. A1 - Schwarzinger, B. A1 - Panne, Ulrich A1 - Weidner, Steffen T1 - Matrix segregation as the major cause for sample inhomogeneity in MALDI dried droplet spots N2 - The segregation in dried droplet MALDI sample spots was analyzed with regard to the matrix-to-sample ratio using optical microscopy, MALDI imaging mass spectrometry (MALDI MSI) and IR imaging spectroscopy. In this context, different polymer/matrix/solvent systems usually applied in the analysis of synthetic polymers were investigated. The use of typical matrix concentrations (10 mg mL-1) in almost every case resulted in ring patterns, whereas higher concentrated matrix solutions always led to homogeneous sample spot layers. The data revealed that segregation is predominantly caused by matrix transport in the drying droplet, whereas polymer segregation seems to be only secondary. KW - MALDI KW - Imaging MS KW - Matrix segregation KW - Dried droplet KW - Sample preparation KW - Polymers PY - 2014 DO - https://doi.org/10.1007/s13361-014-0913-0 SN - 1044-0305 VL - 25 IS - 8 SP - 1356 EP - 1363 PB - American Society for Mass Spectrometry CY - New York, NY AN - OPUS4-32582 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - You, Zengchao A1 - Jakubowski, Norbert A1 - Panne, Ulrich A1 - Weidner, Steffen T1 - Separation of polystyrene nanoparticles with different coatings using two-dimensional off-line coupling of asymmetrical flow field flow fractionation and capillary electrophoresis N2 - The successful off-line coupling of asymmetrical flow field flow fractionation (AF4) and capillary electrophoresis (CE) for separation of nanoparticles (NPs) with different surface coatings was shown. We could successfully demonstrate that, in a certain NP size range, hyphenation of both techniques significantly improved the separation of differently coated NPs. Three mixtures of polystyrene nanoparticles (PS-NPs) with comparable core sizes but different coatings (no coating/carboxyl-coated) were studied. Separation in either method resulted in non-baseline resolved or non-separated peaks. In contrast, two-dimensional off-line coupling of AF4 and CE resulted in clearly separated regions in their 2 D plots in case of 20 and 50 nm particle mixtures, whereas the 100 nm NP mixture could not be separated at all. Various factors affecting the separation like hydrodynamic diameter or SDS concentration were discussed. KW - Capillary electrophoresis (CE) KW - Nanoparticles with same nominal diameter KW - Surface coating KW - Two-dimensional off-line coupling KW - Asymmetrical flow field flow fractionation (AF4) PY - 2019 DO - https://doi.org/10.1016/j.chroma.2019.01.056 VL - 1593 SP - 119 EP - 126 PB - Elsevier AN - OPUS4-47363 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bahlmann, Arnold A1 - Falkenhagen, Jana A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - Cetirizine as pH-dependent cross-reactant in a carbamazepine-specific immunoassay N2 - High performance liquid chromatography (HPLC) was hyphenated with a previously reported carbamazepine-specific enzyme-linked immunosorbent assay (ELISA) as a screening approach to water analysis in order to identify possible interferences from transformation products. Treated wastewater was analysed and three substances were recognized by the antibody besides carbamazepine: the metabolites 10,11-dihydro-10,11-epoxycarbamazepine and 2-hydroxycarbamazepine plus the structurally not obviously related antihistamine cetirizine. The molar cross-reactivity against cetirizine was found to be pH-dependent and assessed to be 400% at pH 4.5 and 22% at pH 10.5. Performing the ELISA at pH 10.5 greatly improved the accuracy when carbamazepine was determined in surface and wastewater samples. KW - Immunoassay KW - ELISA KW - Cetirizin KW - Carbamazepin KW - pH-Abhängigkeit KW - Kreuzreaktivität PY - 2011 DO - https://doi.org/10.1039/c0an00928h SN - 0003-2654 SN - 1364-5528 VL - 136 IS - 7 SP - 1357 EP - 1364 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-23546 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -