TY - JOUR A1 - Walter, Astrid A1 - Pfeifer, Dietmar A1 - Kraus, Werner A1 - Emmerling, Franziska A1 - Schneider, Rudolf A1 - Panne, Ulrich A1 - Weller, Michael G. T1 - Triacetone Triperoxide (TATP): Hapten design and development of antibodies JF - Langmuir N2 - Triacetone triperoxide (TATP), an improvised explosive, is a potential security threat because of its cost-efficient synthesis and the difficulty in detecting it. A highly selective antibody could provide the necessary specificity to the detection process. To obtain antibodies, a hapten made from acetone, hydrogen peroxide, and 7-oxooctanoic acid has been designed, synthesized, and confirmed by NMR that displays the utmost similarity to the analyte. The single-crystal X-ray structures of the solvated species TATP·methanol (1:1) and the TATP derivate were determined. In both compounds, the molecules exhibit D3 symmetry and adopt a twisted boat-chair conformation. The hapten was coupled to bovine serum albumin, and mice were immunized. An immune response against TATP was elicited, and selective antibodies were detected in the mouse serum, which should be very useful for the development of a TATP biosensor system. An ELISA with a limit of detection for TATP of 65 µg L-1 is shown. KW - TATP KW - Triacetone triperoxide KW - Explosive KW - Antibody KW - Hapten immunoassay KW - Structure PY - 2010 DO - https://doi.org/10.1021/la1018339 SN - 0743-7463 SN - 1520-5827 VL - 26 IS - 19 SP - 15418 EP - 15423 PB - American Chemical Society CY - Washington, DC AN - OPUS4-22469 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Traub, Heike A1 - Czerwensky, Michael A1 - Matschat, Ralf A1 - Kipphardt, Heinrich A1 - Panne, Ulrich T1 - Different calibration strategies for the analysis of pure copper metal by nanosecond laser ablation inductively coupled plasma mass spectrometry JF - Journal of analytical atomic spectrometry N2 - In this work, different calibration strategies for the determination of trace elements in pure copper metal by nanosecond laser ablation ICP-MS were investigated. In addition to certified reference materials (CRMs), pellets of doped copper powder were used for calibration. The micro homogeneity of the CRMs as well as the solution-doped pellets was sufficient to use them as calibration samples in combination with a laser spot size of 200 µm. In contrast, pellets doped with analytes in solid form showed a significant heterogeneity. For most of the investigated analytes and copper CRMs the measured mass fractions were within ± 20% of their certified values when other copper CRMs were used as calibration samples. When solution-doped powder pellets were used as calibration samples a systematic trend towards mass fractions below the certified values was observed for nearly all elements determined in the analysed CRMs. Thermal fractionation effects during the ablation of the solution-doped pellets were suspected as the extent of the fractionation depends on the irradiance, whereas fractionation is reduced at higher irradiance. PY - 2010 DO - https://doi.org/10.1039/b915564c SN - 0267-9477 SN - 1364-5544 VL - 25 IS - 5 SP - 690 EP - 696 PB - Royal Society of Chemistry CY - London AN - OPUS4-21195 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schulte, Franziska A1 - Panne, Ulrich A1 - Kneipp, Janina T1 - Molecular changes during pollen germination can be monitored by Raman microspectroscopy JF - Journal of biophotonics N2 - The processes associated with pollen germination were studied in vitro for two tree species, Salix caprea and Fraxinus excelsior under different nutrient conditions. The results provide evidence of changes in chemical composition of the pollen grains during germination. From the comparison of spectra of the pollen grain body and the growing pollen tube, it can be concluded that there are major chemical differences between these two morphological units. Comparison of germinated and ungerminated pollen grains reveals alterations in the metabolism. Composition of the germinating pollen grain and its morphological units depends on the plant species, but also on the nutrient conditions. The results suggest species-specific utilization of metabolite storage, and potential alterations of the pollen outer coat. Furthermore, discharge of molecules into the nutrient medium may depend on the nutrient conditions in the germination experiments. This has implications for further experiments on dynamic processes in pollen and related plant materials. KW - Pollen germination KW - Raman microspectroscopy KW - Imaging KW - Coumaric acid KW - Pollen tube KW - Sporopollenin PY - 2010 DO - https://doi.org/10.1002/jbio.201000031 SN - 1864-063X VL - 3 IS - 8-9 SP - 542 EP - 547 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-23211 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rackwitz, Vanessa A1 - Warrikhoff, A. A1 - Panne, Ulrich A1 - Hodoroaba, Vasile-Dan T1 - Determination of emitted X-ray tube spectra by means of a calibrated instrumental setup JF - Microscopy and microanalysis KW - X-ray tube spectrum KW - XRF KW - SEM KW - EDS KW - Spectrometer efficiency PY - 2010 DO - https://doi.org/10.1017/S1431927610054292 SN - 1431-9276 SN - 1435-8115 VL - 16 IS - Supplement S2 SP - 930 EP - 931 PB - Cambridge University Press CY - New York, NY AN - OPUS4-22471 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Klimakow, Maria A1 - Leiterer, Jork A1 - Kneipp, Janina A1 - Rössler, E. A1 - Panne, Ulrich A1 - Rademann, K. A1 - Emmerling, Franziska T1 - Combined synchrotron XRD/Raman measurements: In situ identification of polymorphic transitions during crystallization processes JF - Langmuir N2 - A combination of two analytical methods, time-resolved X-ray diffraction (XRD) and Raman spectroscopy, is presented as a novel tool for crystallization studies. An acoustic levitator was employed as sample environment. This setup enables the acquisition of XRD and Raman data in situ simultaneously within a 20 s period and hence permits investigation of polymorphic phase transitions during the crystallization process in different solvents (methanol, ethanol, acetone, dichloromethane, acetonitrile). These real time measurements allow the determination of the phase content from the onset of the first crystalline molecular assemblies to the stable system. To evaluate the capability of this approach, the setup was applied to elucidate the crystallization process of the polymorphic compound nifedipine. The results indicate the existence of solvent-dependent transient phases during the crystallization process. The quality of the data allowed the assignment of the lattice constants of the hitherto unknown crystal structure of the β-polymorph. KW - Synchrotron radiation KW - XRD KW - Raman spectroscopy KW - Polymorphism KW - Crystallization KW - Acoustic levitation KW - Nifedipine PY - 2010 DO - https://doi.org/10.1021/la100540q SN - 0743-7463 SN - 1520-5827 VL - 26 IS - 13 SP - 11233 EP - 11237 PB - American Chemical Society CY - Washington, DC AN - OPUS4-21396 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gusarova, Tamara A1 - Hofmann, T. A1 - Kipphardt, Heinrich A1 - Venzago, C. A1 - Matschat, Ralf A1 - Panne, Ulrich T1 - Comparison of different calibration strategies for the analysis of zinc and other pure metals by using the GD-MS instruments VG 9000 and element GD JF - Journal of analytical atomic spectrometry N2 - Synthetic pressed metal powder standards doped with standard solutions were used for the calibration of both commercially available high resolution GD-MS instruments Element GD and VG 9000 for zinc matrix. Different quantification procedures (IBR, Standard RSF, matrix matched RSF from the calibration with CRMs and use of doped synthetic standards) are compared using zinc matrix as an example, whereas the calibration with doped pellets turned out to be the best quantification technique for high-purity materials. The applicability of the Standard RSF concept is scrutinised. In this context, RSF values for several Matrices (Co, Cu, Fe, In and Zn) are reported additionally. PY - 2010 DO - https://doi.org/10.1039/b921649a SN - 0267-9477 SN - 1364-5544 VL - 25 SP - 314 EP - 321 PB - Royal Society of Chemistry CY - London AN - OPUS4-22376 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gornushkin, Igor B. A1 - Shabanov, Sergej V. A1 - Merk, Sven A1 - Tognoni, E. A1 - Panne, Ulrich T1 - Effects of non-uniformity of laser induced plasma on plasma temperature and concentrations determined by the Boltzmann plot method: implications from plasma modeling JF - Journal of analytical atomic spectrometry PY - 2010 DO - https://doi.org/10.1039/C0JA00016G SN - 0267-9477 SN - 1364-5544 VL - 25 SP - 1643 EP - 1653 PB - Royal Society of Chemistry CY - London AN - OPUS4-22942 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gornushkin, Igor B. A1 - Panne, Ulrich T1 - Radiative models of laser-induced plasma and pump-probe diagnostics relevant to laser-induced breakdown spectroscopy JF - Spectrochimica acta B N2 - The paper describes past and present efforts in modeling of laser-induced plasma and overviews plasma diagnostics carried out by pump-probe techniques. Besides general information on existing plasma models, the emphasis is given to models relevant to spectrochemical analysis, i.e. models of radiating plasma. Special attention is paid to collisional-radiative (CR) and collisional-dominated (CD) plasma models where radiative processes play an important role. Also, calibration-free (CF) models are considered which may endow with the possibility for standardless spectroscopic analysis. In the diagnostic part, only methods based on the use of additional diagnostic tools (auxiliary lasers, optics, and probes) are described omitting those based on plasma own radiation. A short review is provided on image-based diagnostics (shadowgraphy, schlieren, and interferometry), absorption and fluorescence, Langmuir probe, and less frequently used cavity ringdown and Thomson scattering methods. KW - Laser ablation KW - Modeling KW - Plasma diagnostics KW - Laser-induced breakdown spectroscopy PY - 2010 DO - https://doi.org/10.1016/j.sab.2010.03.021 SN - 0584-8547 SN - 0038-6987 VL - 65 IS - 5 SP - 345 EP - 359 PB - Elsevier CY - Amsterdam AN - OPUS4-24003 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gopala, Anil A1 - Zellmann, M. A1 - Kipphardt, Heinrich A1 - Jakubowski, Norbert A1 - Panne, Ulrich T1 - Mass spectrometric study of the impurity profile in Zn during reduction-distillation of ZnO with activated and inactivated Al JF - Journal of the American society for mass spectrometry N2 - In this work, we report on the application of hyphenated gas source mass spectrometry to study and understand the mechanism of the reduction-distillation of ZnO using Al powder as reductant in its activated and inactivated form. The experiments revealed that the purity of the Zn metal produced were superior using activated Al with respect to inactivated Al, i.e., m5N8 (99.9998% metallic based) versus m5N3. The achieved purity levels of Zn and the absence of high volatile Cd, Mg, and Sb impurities in the gas phase and the material collected were explained with respect to the impurity elements free-energy values, vapor pressure data, and an observed scavenging effect of the Ta crucible, which was supported by the on-line observed mass spectrometric profiles of the residual gas. PY - 2010 DO - https://doi.org/10.1016/j.jasms.2010.04.009 SN - 1044-0305 VL - 21 IS - 9 SP - 1620 EP - 1623 PB - Elsevier CY - New York, NY AN - OPUS4-21910 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gopala, Anil A1 - Kipphardt, Heinrich A1 - Matschat, Ralf A1 - Panne, Ulrich T1 - Use of mass spectrometric detection as a versatile process monitoring tool: reduction patterns in a milled ZnO/Al mixture JF - Analytical methods N2 - Mass spectrometric detection can play a prominent role in the assessment of different reactions occurring at varied temperatures in a milled ZnO/Al mixture. This is the first time that online mass spectrometric information was used as a tool for monitoring and understanding the chemical reduction process mechanism. We have observed four different types of reaction taking place: (1) distillation of Zn metal, (2) reduction of ZnO by activated Al, (3) melting of Al and finally (4) reduction of ZnO by inactivated Al. The experimental conditions and results observed by QMS were supported with literature data and physical measurement data from X-Ray Diffraction (XRD) which gave us an idea about the complex reaction cascade which occurred during the formation of the zinc metal. PY - 2010 DO - https://doi.org/10.1039/c0ay00057d SN - 1759-9660 SN - 1759-9679 VL - 2 SP - 451 EP - 454 PB - RSC Publ. CY - Cambridge AN - OPUS4-21291 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gopala, Anil A1 - Kipphardt, Heinrich A1 - Matschat, Ralf A1 - Panne, Ulrich T1 - Process methodology for the small scale production of m6N5 purity zinc using a resistance heated vacuum distillation system JF - Materials chemistry and physics N2 - Ultra high purity Zn (m6N5) was obtained through triple vacuum distillation using an m4N5 Zn as input material. High-volatile impurities were removed from the zinc matrix by vacuum evaporation, while traces having lower volatility than the matrix remained in the residual material after finishing of the entire purification process. The time required for the removal of the main high-volatile impurity (Cd) was monitored using a connected gas source mass spectrometer. During distillation the Zn vapor of the distillate was condensed on the cap of a glassy carbon crucible which was water cooled by a movable copper block. The temperatures were optimized for the removal of the volatiles and for the distillation process using vapor pressure data. High resolution glow discharge mass spectrometry was applied for the analysis and purity evaluation of the distilled and input zinc. The analysis confirmed the reduction of the metallic impurities from 43 mg kg-1 to 0.5 mg kg-1 (m6N5) after three consecutive vacuum distillations. An increase in the grain size and a decrease in the micro-hardness were observed for the purified Zn material. KW - Ultra high purity KW - Vacuum distillation KW - High resolution glow discharge mass KW - Spectrometry KW - Micro-hardness KW - Zinc KW - Purification PY - 2010 DO - https://doi.org/10.1016/j.matchemphys.2010.02.080 SN - 0254-0584 VL - 122 IS - 1 SP - 151 EP - 155 PB - Elsevier CY - Amsterdam AN - OPUS4-21127 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gopala, Anil A1 - Jakubowski, Norbert A1 - Panne, Ulrich A1 - Kipphardt, Heinrich T1 - Real time monitoring of chemical transformations during catalytic reduction using gas source mass spectrometry: carbon/zinc carbonate hydroxide JF - Journal of analytical atomic spectrometry N2 - We report herein the utilization of a vacuum reduction distillation system (VRDS) coupled with mass spectrometry (MS) to characterize chemical transformations in thermal analysis. The system initially designed to monitor metal purification by distillation is applied for the first time to the catalytic reaction of in situ formed nickel oxide during the carbothermic reduction of zinc oxide. PY - 2010 DO - https://doi.org/10.1039/c004179c SN - 0267-9477 SN - 1364-5544 VL - 25 SP - 1378 EP - 1380 PB - Royal Society of Chemistry CY - London AN - OPUS4-21911 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Giesen, Charlotte A1 - Jakubowski, Norbert A1 - Panne, Ulrich A1 - Weller, Michael G. T1 - Comparison of ICP-MS and photometric detection of an immunoassay for the determination of ochratoxin A in wine JF - Journal of analytical atomic spectrometry N2 - An immunoassay was developed for ochratoxin A (OTA) detection in wine and two completely different detection methods were compared: ICP-MS and photometry. For labelling, we applied secondary antibodies conjugated with gold nanoparticles for ICP-MS and with horseradish peroxidase for photometric detection, respectively. Detection limits of the assay were determined as 0.003 µg L-1 for both detection methods. OTA in wine was determined below the EU limit value of 2 µg kg-1. The measurement range was between 0.01 and 1 µg L-1 for ICP-MS and photometric detection. Assay precision detected by ICP-MS and photometry were similar showing that precision of the detection method has only a minor effect on total assay precision. By using BSA as a buffer additive to minimize nonspecific binding, we could also confirm that OTA strongly binds to BSA. In a comparison study of several additives, casein was found to be preferable. PY - 2010 DO - https://doi.org/10.1039/c0ja00009d SN - 0267-9477 SN - 1364-5544 VL - 25 IS - 10 SP - 1567 EP - 1572 PB - Royal Society of Chemistry CY - London AN - OPUS4-22704 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Chinthalapati, Siva Kesava Raju A1 - Lück, Detlef A1 - Scharf, Holger A1 - Jakubowski, Norbert A1 - Panne, Ulrich T1 - A novel solid phase extraction method for pre-concentration of gadolinium and gadolinium based MRI contrast agents from the environment JF - Journal of analytical atomic spectrometry N2 - An efficient solid phase extraction (SPE) method using bis-(2-ethylhexyl)-phosphate (HDEHP) coated reverse phase C18 support has been developed for the pre-concentration of Gadolinium (Gd) and Gd contrast agents widely used in magnetic resonance imaging (MRI). Enrichment of Gd in the ionic form has been compared with strong cation exchange material Chromabond SA (SCX), weak ion exchange material Chelex-100 and also with lanthanide specific HDEHP modified reverse phase C18. The determination of Gd and its complexes after enrichment were performed using inductively coupled plasma mass spectrometry (ICP-MS) and on the basis of 158Gd. Among the three SPE materials, HDEHP coated reverse phase C18 SPE has been found to be most efficient, yielding a hundredfold Gd enrichment with > 95% recovery for linear and cyclic contrast agents like Gd-DTPA (Magnevist), Gd-DOTA (Dotarem), Gd-BOPTA (Multihance), and Gd-BT-DO3A (Gadovist). The developed SPE method has been successfully applied to the surface water and waste water samples originated from different places in Berlin, Germany. The results were in good agreement with the results obtained with direct measurement with ICP-MS. The developed pre-concentration method can be efficiently used for the determination of trace levels of gadolinium in the environment even with less sensitive analytical techniques. KW - Solid phase extraction KW - Magnetic resonance imaging KW - Gadolinium KW - Gd based contrast agents KW - Chelex-100 KW - HDEHP KW - Speciation PY - 2010 DO - https://doi.org/10.1039/c003251d SN - 0267-9477 SN - 1364-5544 VL - 25 IS - 10 SP - 1573 EP - 1580 PB - Royal Society of Chemistry CY - London AN - OPUS4-21985 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Chinthalapati, Siva Kesava Raju A1 - Cossmer, Antje A1 - Scharf, Holger A1 - Panne, Ulrich A1 - Lück, Detlef T1 - Speciation of gadolinium based MRI contrast agents in environmental water samples using hydrophilic interaction chromatography hyphenated with inductively coupled plasma mass spectrometry JF - Journal of analytical atomic spectrometry KW - HPLC-ICP-MS KW - HILIC chromatography KW - Speciation KW - Gadolinium KW - MRI contrast agent PY - 2010 DO - https://doi.org/10.1039/b919959d SN - 0267-9477 SN - 1364-5544 VL - 25 SP - 55 EP - 61 PB - Royal Society of Chemistry CY - London AN - OPUS4-20705 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carvalho, José Joao A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - A highly sensitive caffeine immunoassay based on a monoclonal antibody JF - Analytical and bioanalytical chemistry KW - Caffeine KW - ELISA KW - Antibody KW - LC–MS–MS KW - Water KW - Wastewater marker PY - 2010 DO - https://doi.org/10.1007/s00216-010-3506-1 SN - 1618-2642 SN - 1618-2650 VL - 396 IS - 7 SP - 2617 EP - 2628 PB - Springer CY - Berlin AN - OPUS4-22651 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -