TY - CONF A1 - Palkowski, Carsten T1 - Dynamic Test Method - an Update N2 - An update about the dynamic test method for the determination of the seasonal performance of heat pumps given at the CEN/TC 113/WG 7 meeting. T2 - Meeting of CEN/TC 113/WG 7 CY - Courbevoie, France DA - 14.01.2020 KW - Heat pump KW - Dynamic test method KW - Seasonal performance KW - Coefficient of performance PY - 2020 AN - OPUS4-50579 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Palkowski, Carsten T1 - Test methods for air conditioners N2 - Comparison of test methods for air conditioners that are currently discussed in standardization. The limitations of the current standard are shown and different options for the further development of the standard are presented T2 - Arbeitsgruppensitzung des Fachverbands Gebäude-Klima CY - Online meeting DA - 28.05.2020 KW - air conditioner KW - test method KW - Load-based testing KW - energy label PY - 2020 AN - OPUS4-50829 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Palkowski, Carsten T1 - Test methods for heat pumps N2 - Comparison of different test methods for the determination of the seasonal performance of heat pumps: 1) The current test standard EN14825, 2) the compensation test method and 3) the dynamic test method. T2 - Impact Assessment / Consultation Space and Water Heaters WG2 Testing CY - Online meeting DA - 02.04.2020 KW - Heat pump KW - Energy label KW - Seasonal performance KW - Compensation method KW - Dynamic method PY - 2020 AN - OPUS4-50713 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Palkowski, Carsten T1 - Technical Meeting BAM RRT for Heat Pumps N2 - Kickoff meeting for the BAM round robin test for load-based heat pump testing T2 - Kickoff meeting BAM RRT for heat pumps CY - Online meeting DA - 26.03.2020 KW - Heat pump KW - Round robin test KW - Load-based testing KW - Compensation method KW - Energy efficiency PY - 2020 AN - OPUS4-50715 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Palkowski, Carsten T1 - Technical Meeting BAM RRT for Air Conditioner N2 - Kickoff meeting for the BAM round robin test for load-based air conditioner testing. T2 - Kickoff meeting BAM RRT for air conditioner CY - Online meeting DA - 26.03.2020 KW - Air conditioner KW - Round robin test KW - Load-based testing KW - Compensation method KW - Energy efficiency PY - 2020 AN - OPUS4-50716 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Palkowski, Carsten T1 - BAM Round Robin Test for Heat Pumps and Air Conditioners N2 - Preliminary results of the BAM RRTs are given in this presentation. T2 - VHK Meeting CY - Online meeting DA - 11.11.2020 KW - Heat Pumps KW - Air Conditioners KW - Round Robin Test KW - Load-Based Test Method KW - Energy Label PY - 2020 AN - OPUS4-51969 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Palkowski, Carsten T1 - Dynamische Methode für die Energieeffizienzprüfung von Wärmepumpen N2 - Vorstellung der Dynamische Wärmepumpenprüfung beim DIN NA-044-00-06 AA T2 - Gremiunssitzung des NA 044-00-06 AA CY - Munich, Germany DA - 19.02.2019 KW - Wärmepumpen KW - Energieeffizienz KW - Dynamische Prüfung PY - 2019 AN - OPUS4-47414 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Palkowski, Carsten A1 - Zottl, A. A1 - Malenkovic, I. A1 - Simo, Anne T1 - Fixing efficiency values by unfixing compressor speed: Dynamic test method for heat pumps N2 - The growing market penetration of heat pumps indicates the need for a performance test method that better reflects the dynamic behavior of heat pumps. In this contribution, we developed and implemented a dynamic test method for the evaluation of the seasonal performance of heat pumps by means of laboratory testing. Current standards force the heat pump control inactive by fixing the compressor speed. In contrast, during dynamic testing, the compressor runs unfixed while the heat pump is subjected to a temperature profile. The profile consists of the different outdoor temperatures of a typical heating season based on the average European climate and also includes temperature changes to reflect the dynamic behavior of the heat pump. The seasonal performance can be directly obtained from the measured heating energy and electricity consumption making subsequent data interpolation and recalculation with correction factors obsolete. The method delivers results with high precision and high reproducibility and could be an appropriate method for a fair rating of heat pumps. KW - Heat pump KW - Dynamic test method KW - Seasonal performance factor KW - Variable frequency drive KW - Energy label PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-476944 DO - https://doi.org/10.3390/en12061045 SN - 1996-1073 VL - 12 IS - 6 SP - 1045, 1 EP - 16 PB - MDPI CY - Basel, Switzerland AN - OPUS4-47694 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Palkowski, Carsten T1 - Dynamic Test Method for Heat Pumps N2 - Vorstellung der Dynamischen Wärmepumpenprüfung beim CEN/TC 113/WG 7 N2 - Presentation of the dynamic test method for the determination of the seasonal performance of heat pumps at CEN/TC 113/WG 7. T2 - Meeting of CEN/TC 113/WG 7 CY - Stockholm, Sweden DA - 23.04.2019 KW - Heat pump KW - Energy label KW - Seasonal performance KW - Coefficient of performance PY - 2019 AN - OPUS4-48308 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Palkowski, Carsten A1 - Schwarzenberg, S. A1 - Simo, Anne T1 - Seasonal cooling performance of air conditioners: The importance of independent test procedures used for MEPS and labels N2 - Minimum energy performance standards and labels are commonly used tools to reduce the household energy use thus mitigating greenhouse gas emissions. However, the technical foundation for minimum energy performance standards and labels are test procedures for rating and testing of appliances. To de- termine the seasonal cooling performance of air conditioners, the current test standards require fixing of the compressor speed of the units to achieve steady-state conditions; this way of operation, how- ever, differs from real-life use. To make the seasonal cooling performance testing better reflect the real use conditions, this study proposes a compensation method which can be conducted independently from manufacturer data and still allows modulation of the tested units. Our results show that the tested units behave differently under part-load conditions, which results in a lower energy efficiency rating for some of the tested devices. KW - Air conditioner KW - Independent test method KW - Real use behavior KW - Seasonal energy efficiency ratio KW - Minimum energy performance standards KW - Energy label PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-485813 DO - https://doi.org/10.1016/j.ijrefrig.2019.05.021 SN - 0140-7007 VL - 104 SP - 417 EP - 425 PB - Elsevier AN - OPUS4-48581 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -