TY - CONF A1 - Otremba, Frank A1 - Romero Navarrete, J. A. T1 - Assesing rail damage in turns due to lateral load transfer N2 - A testing procedure is proposed and used, to estimate the rail damage potentials of variations in both, the height of the cargo´s center of gravity and the railway car suspension´s spring constant. The experimental setup consisted of a tilt table that slowly exerted an increasing lateral acceleration on a two-axle bogie-type vehicle equipped with a spring supported container. The potential damaging effect derived from the resulting lateral load transfer, was assessed on the basis of the fourth-power law. Results suggest that the cargo having a higher center of gravity could be more damaging to the outside rail when compared with the effect of the shorter center of gravity of the cargo, in arrange from0.94% to 3.17%, as a function of the spring constant of the suspension. Consequently, and comparatively, there would be a long-term damaging effect on the rail when having a cargo with a higher center of gravity, so that specific cargo, having a high center of gravity, would be more aggressive to the infrastructure. On the other hand, for the range of time rate changes of the lateral acceleration, it was not found a consistent trend regarding the effect of the value of the spring constant on the magnitude of the load transfers. T2 - ASME 2024 CY - Portland, OR, USA DA - 17.11.2024 KW - Rail demage KW - Lateral load transfer PY - 2024 AN - OPUS4-61784 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Otremba, Frank A1 - Romero Navarrete, J. A. T1 - Assesing rail damage in turns due to lateral load transfer N2 - A testing procedure is proposed and used, to estimate the rail damage potentials of variations in both, the height of the cargo´s center of gravity and the railway car suspension´s spring constant. The experimental setup consist ed of a tilt table that slowl y exer ted an increasing lateral acceleration on a two axle bog ie type vehicle equipped with a spring supported container. The potential damaging effect derived from the resulting lateral load transfer, was assessed on the basis of the fourth power law. Results suggest that the cargo having a higher center of gravity could be more damagi ng to the outside rail when compared with the effect of the shorter center of gravity of the cargo, in a range from 0.94% to 3.17%, as a function of the spring constant of the suspension. Consequently and comparatively there would be a long term damaging effect on the rail when having a cargo with a high er center of gravity, so that specific cargo, having a high center of would be more aggressive to the infrastructure On the other hand for the range of time rate changes of the lateral acceleration, it was not found a consisten t trend regarding the effect of the value of the spring constant on the magnitude of the load transfers . T2 - IMECE 2024 CY - Portland, Oregon, USA DA - 17.11.2024 KW - Railway damage KW - Load transfer KW - Fourth power law KW - Experimental methods KW - Center of gravity KW - Tilt table KW - Suspension spring constant PY - 2024 SN - 978-0-7918-8869-8 SP - 1 EP - 4 PB - ASME AN - OPUS4-61785 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hajhariri, Aliasghar A1 - Eberwein, Robert A1 - Perrone, Luca Pakj A1 - Cozzani, Valerio A1 - Otremba, Frank A1 - Seidlitz, Holger T1 - Study the impact of spacer at thermal degradation process of MLI-based insulation in fire condition N2 - To reduce CO2 emissions, energy carriers such as hydrogen are considered to be a solution. Consumption of hydrogen as a fuel meets several limitations such as its low volumetric energy density in gas phase. To tackle this problem, storage as well as transportation in liquified phase is recommended. To be able to handle this component in liquid phase, an efficient thermal insulation e.g., MLI insulation is required. Different studies have been addressed the vulnerability of such insulation against high thermal loads e.g., in an accident engaging fire. Some of research works have highlighted the importance of considering the MLI thermal degradation focusing on its reflective layer. However, limited number of studies addressed the thermal degradation of spacer material and its effect on the overall heat flux. In this study, through systematic experimental measurements, the effect of thermal loads on glass fleece, glass paper as well as polyester spacers are investigated. The results are reported in various temperature and heat flux profiles. Interpreting the temperature profiles revealed that, as the number of spacers in the medium increases, the peak temperature detectable by the temperature sensor on the measurement plate decreases. Each individual spacer contributes to mitigating the radiative energy received by the measurement plate. Stacks of 20–50 spacers (this is the number of layers in commercial MLI systems applied for liquid hydrogen applications) can potentially reduce the thermal radiation by 1–2 orders of magnitude. An empirical correlation to predict a heat flux attenuation factor is proposed, which is useful for further numerical and analytical studies in the temperature range from ambient to 300 ◦C. KW - Cryogenic KW - Liquid Hydrogen KW - Multi-Layer Insultation KW - Heat Transfer KW - Hydrogen Storage Safety PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-614919 DO - https://doi.org/10.1016/j.jlp.2024.105461 SN - 0950-4230 VL - 92 SP - 1 EP - 7 PB - Elsevier Ltd. AN - OPUS4-61491 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Camplese, Davide A1 - Scarponi, Giordano Emrys A1 - Eberwein, Robert A1 - Hajhariri, Aliasghar A1 - Otremba, Frank A1 - Cozzani, Valerio T1 - Modelling Fire Response of Cryogenic Liquid Hydrogen Tanks Equipped with Multilayer Insulation (MLI) Systems N2 - In the context of the growing global interest in hydrogen-based green energy, cryogenic tanks equipped with multi-layer insulation (MLI) are emerging as a leading solution for storing hydrogen in vehicles. The integrity of these systems might be threatened during fire exposure. This can trigger the degradation of the MLI materials and induce rapid pressurization of the tank with a high risk of catastrophic failure. In this work, a novel lumped model to simulate the thermal response of MLI-equipped cryogenic liquid hydrogen tanks is presented. The model integrates the accurate database “Coolprop” for hydrogen thermodynamic properties and sub-models for detailed simulation of MLI degradation, providing a realistic simulation of the experimental data obtained under normal operating conditions. The application of the model to several case studies considering different numbers of MLI layers and tank geometries demonstrates that aluminum-based MLI offers scarce protection in case of exposure to a hydrocarbon poolfire. T2 - CISAP 11 CY - Neapel, Italy DA - 15.09.2024 KW - LH2 KW - LNG KW - Cryogenic storage tank KW - Insulation KW - MLI PY - 2024 DO - https://doi.org/10.3303/CET24111076 SN - 2283-9216 VL - 111 SP - 451 EP - 456 PB - AIDIC The Italian Association of Chemical Engineering AN - OPUS4-61384 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert A1 - Hajhariri, Aliasghar A1 - Camplese, Davide A1 - Scarponi, Giordano Emrys A1 - Cozzani, Valerio A1 - Otremba, Frank ED - Di Benedetto, Almerinda T1 - Experimental Research Of A Tank For A Cryogenic Fluid With A Wall Rupture In A Fire Scenario N2 - In the course of decarbonizing the energy industry, cryogenic energy carriers as liquefied hydrogen (LH2) and liquefied natural gas (LNG) are seen as having great potential. In technical applications, the challenge is to keep these energy carriers cold for a long time. This is achieved in the road transport sector and also stationary applications by thermal super insulations (TSI) which based on double-walled tanks with vacuum and multilayer insulation (MLI) in the interspace. This study focuses on the behaviour of widely used combustible MLI in a fire scenario, at vacuum and atmospheric pressure conditions. The former corresponds to the typical design condition and the latter to the condition after an outer hull rapture of a tank. Furthermore, two fire scenarios were taken into account: a standard-oriented approach and a hydrocarbon fire-oriented approach. For the study, a test rig was applied that allows testing of TSI at industrial conditions and subsequent analysis of TSI samples. The test rig allows thermal loading and performance analysis of TSI samples at the same time. Comparing the tests, the samples degraded differently. However, no sudden failure of the entire MLI was observed in any test. These results are relevant for the evaluation of incidents with tanks for the storage of cryogenic fluids and can thus contribute to the improvement of TSI and the development of emergency measures for the protection of persons and infrastructures. T2 - 15th International Symposium on Hazards, Prevention and Mitigation of Industrial Explosions (ISHPMIE) CY - Neapel, Italy DA - 10.06.2024 KW - Liquefied hydrogen KW - Liquefied natural gas KW - Cryogenic storage tank KW - Fire KW - Thermal insulation KW - Multi-Layer Insulation PY - 2024 SP - 707 EP - 717 AN - OPUS4-60460 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Camplese, Davide A1 - Scarponi, Giordano Emrys A1 - Chianese, Carmela A1 - Hajhariri, Aliasghar A1 - Eberwein, Robert A1 - Otremba, Frank A1 - Cozzani, Valerio T1 - Modeling the performance of multilayer insulation in cryogenic tanks undergoing external fire scenarios N2 - Multilayer Insulation (MLI) is frequently used in vacuum conditions for the thermal insulation of cryogenic storage tanks. The severe consequences of the degradation of such materials in engulfing fire scenarios were recently evidenced by several large-scale experimental tests. In the present study, an innovative modelling approach was developed to assess the performance of heat transfer in polyester-based MLI materials for cryogenic applications under fire conditions. A specific layer-by-layer approach was integrated with an apparent kinetic thermal degradation model based on thermogravimetric analysis results. The modeling results provided a realistic simulation of the experimental data obtained by High-Temperature Thermal Vacuum Chamber tests reproducing fire exposure conditions. The model was then applied to assess the behavior of MLI systems for liquid hydrogen tanks in realistic fire scenarios. The results show that in intense fire scenarios degradation occurs rapidly, compromising the thermal insulation performances of the system within a few minutes. KW - Multilayer Insulation KW - Cryogenic Vessels KW - Liquefied Hydrogen KW - Liquefied Natural Gas KW - Safety KW - Fire PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-599418 DO - https://doi.org/10.1016/j.psep.2024.04.061 SN - 0957-5820 VL - 186 SP - 1169 EP - 1182 PB - Elsevier B.V. AN - OPUS4-59941 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hajhariri, Aliasghar A1 - Eberwein, Robert A1 - Camplese, Davide A1 - Scarponi, Giordano Emrys A1 - Cozzani, Valerio A1 - Otremba, Frank A1 - Seidlitz, Holger T1 - Non-combustible MLI based insulation behavior under fire condition - Experimental and numerical investigation N2 - The number of applications that demand zero-emission energy carriers, such as liquified hydrogen (LH2), is increasing worldwide. LH2 is typically transported or stored under cryogenic conditions. Storage in such conditions requires super thermal insulations which maintain very low boil-off for a prolonged time. Multi-Layer insulation (MLI) finds widespread use in cryogenic applications, designed to effectively restrict heat inleak towards cryogenic fluids. However, recent studies evidenced that exposure to high heat fluxes, such as in the event of a fire accident, can cause the thermal degradation of the insulation material, resulting in the severe collapse of its heat resistance performance. Therefore, the risk of rapid tank pressurization and its connection to the risk of BLEVE may be possible. This study proposes a numerical model to assess the performances of aluminum-based MLI materials under fire conditions. The model offers insights into the total heat transfer rate through the insulation, serving as a KW - Multi-Layer Insulation KW - Cryogenic KW - Liquid Hydrogen KW - CFD PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-617780 DO - https://doi.org/10.1016/j.psep.2024.11.037 VL - 193 SP - 603 EP - 620 PB - Elsevier B.V. AN - OPUS4-61778 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eberwein, Robert A1 - Scarponi, Giordano Emrys A1 - Cozzani, Valerio A1 - Otremba, Frank T1 - Lh2 Tanks In Fire Incidents - The Cryogenic High Temperature Thermal Vacuum Chamber Enables In-Depth Insights N2 - Liquefied Hydrogen (LH2) and Liquefied Natural Gas (LNG) establish themselves as important energy carriers in the transport sector. Their storage requires tanks with thermal super-insulations to keep them at cryogenic conditions for a long time. These insulation systems have proven itself in various applications over a long time. However, these insulations are still new in land transportation, where accidents involving collisions, fires, and their combination are to be expected. This study summarizes the results of the ongoing research program in which insulations commonly used in industry were analysed through experimental and numerical studies under fire-like conditions. It was found that there are strong differences among the various insulation systems. Several safety concerns and research gaps exists for layered insulations, which are typically used in land transport. To further analyse these insulation systems, a new test concept called Cryogenic High Temperature Thermal Vacuum Chamber (CHTTVC) was developed and manufactured. This concept enables the testing of large insulation samples under industrial conditions and the consideration of cryogenic conditions relevant for the investigation of various phenomena. The results are important for the evaluation of accident scenarios, the improvement of thermal super-insulations, and the development of emergency measures. T2 - IMECE 2024 CY - Oregon, Portland, USA DA - 17.11.2024 KW - LH2 KW - LNG KW - Fire KW - Insulation KW - Safety PY - 2024 SN - 978-0-7918-8869-8 SP - 1 EP - 7 PB - ASME AN - OPUS4-61751 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - An, Q. A1 - Bäßler, Ralph A1 - Hertwig, Andreas A1 - Rehfeldt, Rainer A1 - Hidde, Gundula A1 - Otremba, Frank T1 - Investigation of Mechanical Stress and B10 Exposure on FKM Polymer N2 - Mechanical stress often accelerates the failure of polymer materials. The aim of this research is to study the interaction between the sealing material FKM and biofuels B10 (heating oil with 10% biodiesel). The mechanical stress test was carried out in a special apparatus. Both mechanical and non-mechanical stress tests were conducted on specimens at 20, 40, and 70 °C for 28 days to document changes in mass, volume, and tensile properties. Both increasing temperature and mechanical stress have a significant effect on the tensile strength of the FKM polymer when exposed to B10. The combination of increasing temperature and mechanical stress induced rupture within 2 h. It was also established that FKM polymer with pre-exposure in B10 survived longer during mechanical stress compared to specimens exposed only to air. With the support of infrared (IR) spectroscopy, we were able to confirm the penetration of B10 into the FKM polymer. T2 - TMS 2024 Annual Meeting & Exhibition Teilnahme mit Präsentation CY - Orlando-Florida / USA DA - 03.03.2024 KW - Biofuels KW - Sealing materials KW - Mechanical stress KW - Change in tensile properties PY - 2024 SN - 978-3-031-50349-8 DO - https://doi.org/10.1007/978-3-031-50349-8_108 SP - 1253 EP - 1261 PB - Springer CY - Orlando-Florida / USA AN - OPUS4-59638 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Otremba, Frank A1 - An, Q. A1 - Bäßler, Ralph A1 - Hertwig, Andreas A1 - Rehfeldt, Rainer A1 - Hidde, Gundula T1 - Investigation of mechanical stress and B10 exposure on FKM polymer N2 - Biofuels, particularly biodiesel, have gained significant attention as an alternative to traditional fossil fuels in recent years. Unlike diesel, which contains hundreds of compounds, biodiesel only contains a few compounds in the C16-C18 carbon chain. However, the use of biodiesel in automobile and transportation applications can result in problems of degradation or even damage in materials. Among the commonly used polymer materials, fluorocarbon (FKM) shows excellent performance and high stability and compatibility towards oil, diesel, ethanol, and other chemicals. FKM is a family of fluorocarbon-based fluoroelastomer materials, which provide excellent high-temperature and chemical stability compared to other elastomers. As a result, FKM is widely used in chemical processes such as petroleum refining, where it is used for sealings, pumps, and other components. T2 - TMS 2024 153rd Annual Meeting & Exhibition Supplemental Proceedings CY - Orlando, Florida, USA DA - 03.03.2024 KW - B10 exposure KW - FKM polymer PY - 2024 AN - OPUS4-59636 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -