TY - CONF A1 - Noske, Reinhard A1 - Stolle, Dirk A1 - Juritsch, Elevtheria A1 - Subaric-Leitis, Andreas T1 - Sprengstoff - Detektion mit Sensoren T2 - elmug4future, Technologiekonferenz mit Kooperationsbörse CY - Suhl, Germany DA - 2010-06-22 PY - 2010 AN - OPUS4-22458 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wander, Lukas A1 - Paul, Andrea A1 - Rurack, Knut A1 - Biyikal, Mustafa A1 - Juritsch, Elevtheria A1 - Bernstein, Thomas A1 - Bartholmai, Matthias A1 - Noske, Reinhard T1 - Kompaktsensor zur Online-Überwachung von Nitroaromaten N2 - Nitroaromaten und insbesondere Trinitrotoluol (TNT) sind weit verbreitete Spreng- und Umweltschadstoffe. Die größte Herausforderung bei der Detektion von TNT in der Gasphase ist der geringe Dampfdruck. Derzeit werden vielerorts günstige, schnelle, handliche und einfach zu bedienende Alternativen zur klassischen TNT-Analytik entwickelt. Aktuell existieren keine einheitlichen Richtlinien für Sprengstoffsensoren. Hier wird die Entwicklung eines Messplatzes zur Validierung von Sprengstoffsensoren sowie die Erprobung eines kompakten Mustersensors vorgestellt. T2 - 12. Kolloquium Prozessanalytik CY - Berlin, Germany DA - 28.11.2016 KW - Nitroaromaten KW - Fluoreszenzlöschung KW - Sensor PY - 2016 SP - P11, 61 EP - 62 AN - OPUS4-38402 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartholmai, Matthias A1 - Ebert, Sebastian A1 - Neumann, Patrick P. A1 - Noske, Reinhard A1 - Rehak, W. A1 - Lazik, D. T1 - Linear gas sensor for methane based on a selectively permeable membrane N2 - In preliminary work, gas sensors in linear form based on the measuring principle of gas selective permeability through a membrane were developed and introduced for the detection and quantification of gas concentrations. In this study, first experimental results are presented for adapting the technology for measuring methane (CH4). A material with suitable selective permeability was identified and utilized in a sensor setup containing the gas selective membrane and a reference membrane, both integrated in a measuring cell, to which a gas stream with defined CH4 concentrations was applied. The results prove the sensor's capability for measuring methane and indicate further application potential of the method, e.g., as a robust field monitoring technology, since CH4 is the major component of natural gas, town gas, and fracking gas. T2 - AMA Conferences 2015 with SENSOR and IRS2 CY - Nuremberg, Germany DA - 19.05.2015 KW - Selective permeability KW - Quantification of gas concentrations KW - Spatially distributed monitoring KW - Gas storage sites KW - Methane measuring PY - 2015 SN - 978-3-9813484-8-4 U6 - https://doi.org/10.5162/sensor2015/P8.1 SP - 833 EP - 835 AN - OPUS4-33263 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gawlitza, Kornelia A1 - Tiebe, Carlo A1 - Banach, Ulrich A1 - Noske, Reinhard A1 - Bartholmai, Matthias A1 - Rurack, Knut T1 - Novel sensor for long-term monitoring of ammonia in gas phase N2 - Because ammonia and its reaction products can cause considerable damage to human health and ecosystems, there is a need for reliably operating and reversibly interacting sensor materials to monitor traces of gaseous ammonia in ambient air, which at best can be used on-site for in-the-field measurements. Herein, the development of a sensor material for gaseous ammonia in the lower ppm to ppb range using optical fluorescence as transduction mechanism is presented. A fluorescent dye, which shows reversible fluorescence enhancement in the presence of ammonia is incorporated into a polymer matrix, the latter to ensure the accumulation of ammonia. The sensor material is integrated into a prototype of a miniaturized sensor device, facilitating long-term operation. To calibrate the optical sensor system a gas standard generator, producing standard gas mixtures, is used, leading to a sensitivity down to lower ppm concentrations of ammonia. T2 - 13. Dresdner Sensor-Symposium 2017 CY - Dresden, Germany DA - 04.12.2017 KW - Ammonia gas sensor KW - Fluorescence KW - Air quality monitoring KW - Standard gas generator KW - Miniaturized sensor device PY - 2017 U6 - https://doi.org/10.5162/13dss2017/P4.02 SP - P4.02, 272 EP - 276 AN - OPUS4-43352 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Johann, Sergej A1 - Noske, Reinhard A1 - Feller, Viktor A1 - Bartholmai, Matthias ED - Vonau, Winfried ED - Cruvinel, P. ED - Chilibon, I. ED - Carvalho, V. ED - Sophocleous, M. T1 - Gas detection using a multi-sensor device with pump control and VOC sensor N2 - This paper deals with the development and investi-gation of a volatile organic compound (VOC) system for differ-ent scenarios. The integrated multi-sensor unit can detect dif-ferent gases through the integrated 3-fold VOC sensor, where-by a continuous measurement takes place. The system-integrated flow control, with pump and flow sensor, allows the gas molecules to be transported directly to the VOC sensor. The entire measurement is permanently stored on an integrat-ed Secure Digital (SD) card. If the previously determined limit range is exceeded, an alarm is generated. Due to the combina-tion of different components, numerous applications are possi-ble. The system is the first step or a tool towards further devel-opments in the field of gas sensors and is primarily used for the validation of chemically based gas sensors, and it is still largely extended by application-specific influences. T2 - Sensordevices 2017 - The Eighth International Conference on Sensor Device Technologies and Applications CY - Rome, Italy DA - 2017-09-10 KW - Gas detection KW - VOC KW - Pump control KW - Multi sensor device PY - 2017 SN - 978-1-61208-581-4 SP - 1 EP - 4 CY - Rome, Italy AN - OPUS4-42097 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Rockstroh, Jens A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Noske, Reinhard A1 - Brödner, Doris A1 - Schneider, Uwe A1 - Horn, Wolfgang ED - Wai, T. K. ED - Sekhar, C. ED - Cheong, D. T1 - Investigations on VOC, ozone and dust emissions from hardcopy devices (laser printers, copiers and multifunctional devices) in test chambers - development of a test method T2 - 7th Healthy Buildings Conference ; HB 2003 ; ISIAQ international conference CY - Singapore, Republic of Singapore DA - 2003-12-07 KW - Emissions KW - Printers KW - Copiers KW - VOC KW - Dust KW - Ozone KW - Blue Angel PY - 2003 SN - 981-049974-4 VL - 1 SP - 397 EP - 403 CY - Singapore AN - OPUS4-3315 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Jann, Oliver A1 - Rockstroh, Jens A1 - Wilke, Olaf A1 - Noske, Reinhard A1 - Brödner, Doris A1 - Schneider, Uwe A1 - Horn, Wolfgang T1 - Entwicklung einer Prüfmethode und Untersuchungen zur Begrenzung von Emissionen aus Druckern und Kopiergeräten im Rahmen der Umweltzeichenvergabe (Forschungsbericht 201 95 311/02 / UBA-FB 000510) N2 - An neun verschiedenen Hardcopygeräten wurden in unterschiedlichen Emissionsmesskammern (zwei verschiedene 1 m³ - Kammern und eine 20 m³ - Kammer) in Kombination mit geeigneten Probenahme- und Analysenverfahren Untersuchungen zum Emissionsverhalten dieser Geräte hinsichtlich Staub, Ozon und VOC (TVOC) durchgeführt. Luftprobenahme und Analytik erfolgten für VOC mittels Tenax TA und anschließender Thermodesorption (TDS) in Verbindung mit GC / MS. Ozon wurde kontinuierlich bestimmt. Der Ozonanalysator arbeitete auf der Grundlage der flammenlosen Reaktion von Ozon mit Ethylen nach dem Prinzip der Chemilumineszenz. Die Staubbestimmung erfolgte gravimetrisch mittels Glasfaserfilter und Ultramikrowaage. Zusätzlich wurde die Partikelemission während des Druckbetriebes mit einem Partikelzähler bestimmt. Aufgrund der technischen Rahmenbedingungen standen nur kurze Druckzeiten von maximal 36 Minuten zur Verfügung. Um die Gleichgewichtskonzentration in der Prüfkammer zu erreichen, wurde die Luftaustauschrate in den 1 m³ - Kammern auf n = 4,0 bis 4,7 pro Stunde erhöht. Zusätzlich zur Prüfung in den Emissionsmesskammern sind verschiedene Papiere mittels Direkt - TDS sowie unterschiedliche Toner mittels Headspaceprobenahme in Kombination mit GC / MS hinsichtlich ihres Emissionsverhaltens untersucht worden. Für die untersuchten Geräte wurden Emissionsraten ermittelt. Sie betrugen für TVOC 0,41 bis 22,4 mg pro Stück und Stunde, für Ozon kleiner 0,02 bis 4,6 mg pro Stück und Stunde sowie für Staub 0,10 bis 7,63 mg pro Stück und Stunde. Verglichen mit Frischfaserpapier wurden bei den Untersuchungen mit Recyclingpapier deutlich höhere SVOC - Konzentrationen nachgewiesen. Im Ergebnis der Untersuchungen wurde ein Prüfverfahren entwickelt, das die Basis für Emissionsmessungen im Rahmen der Umweltzeichen RAL –UZ 62, RAL –UZ 85 sowie des neuen RAL –UZ 114 für Multifunktionsgeräte darstellt. KW - Emissionen KW - VOC KW - Ozon KW - Staub KW - Hardcopygerät KW - Drucker KW - Kopierer KW - Emissionsmesskammer KW - Umweltzeichen PY - 2003 UR - http://www.umweltbundesamt.de/publikationen/entwicklung-einer-pruefmethode-untersuchungen-zur SN - 1862-4804 SN - 0722-186X IS - 71 SP - 1 EP - 159 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-7276 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -