TY - JOUR A1 - Mietz, Jürgen A1 - Burkert, Andreas A1 - Eich, Gerd A1 - Raupach, M. T1 - Development of a new combined corrosion protection system for chloride-contaminated reinforced concrete structures N2 - Chloride-induced damage of reinforcing steel is especially for parking garages and bridges often very severe as large amounts of chlorides act on horizontal surfaces which could lead to fast ingress of these detrimental ions up to the level of the reinforcement and subsequently to high rates of corrosion. In order to avoid the disadvantages of conventional rehabilitation (unreliable prognosis with patch repair or high costs and regular maintenance with cathodic protection using impressed current) a new combined protection system was developed where the principle of drying out the concrete (by means of a surface protection system) is combined with a temporary cathodic protection (by means of a sprayed zinc layer) during the transitional period of the drying out process. This new system was tested both in the laboratory and on-site at a pilot application. Based on the results obtained the possibilities and limitations of the new system are discussed in this paper. KW - Chlorid-induced corrosion KW - Reinforcing steel KW - Cathodic protection KW - Sprayed zinc layer KW - Surface protection system PY - 2005 DO - https://doi.org/10.1002/maco.200403836 SN - 0947-5117 SN - 1521-4176 VL - 56 IS - 2 SP - 104 EP - 110 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-7157 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Burkert, Andreas A1 - Mietz, Jürgen T1 - Korrosionsschäden an Lagertanks für Salzlake N2 - An einem Tankbehälter aus dem Werkstoff X2CrNiMo17-12-2, der zur Zwischenlagerung von Salzlake für die Käseherstellung dient, wurden trotz langjähriger positiver Erfahrungen an vergleichbaren Anlagen bereits kurze Zeit nach der Inbetriebnahme Lochkorrosionserscheinungen festgestellt. Durch entsprechende elektrochemische Laboruntersuchungen konnte gezeigt werden, dass die vorgefundene Lochkorrosion durch den Einsatz eines Oxidationsmittels zu Desinfektionszwecken verursacht wurde. Translated Abstract Corrosion damage at storage tanks for salt brine A tank made of stainless steel type X2CrNiMo17-12-2 for intermediate storage of salt brine for cheese production revealed significant pitting corrosion effects shortly after commissioning although comparable units have shown positive long-term behaviour. By means of electrochemical laboratory tests it could be demonstrated that the observed pitting corrosion was caused by the use of an oxidizing agent for desinfection purposes. PY - 2003 SN - 0947-5117 SN - 1521-4176 VL - 54 IS - 2 SP - 113 EP - 118 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-2378 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -