TY - JOUR A1 - Simons, C. A1 - Mans, C. A1 - Hanning, S. A1 - Janßen, A. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Ostermann, Markus A1 - Michaelis, Matthias A1 - Wienold, Julia A1 - Alber, D. A1 - Kreyenschmidt, M. T1 - Study on microscopic homogeneity of polymeric candidate reference materials BAM H001-BAM H010 by means of synchrotron µ-XRF and LA-ICP-MS N2 - In this study the microscopic homogeneity of the newly developed plastic reference materials BAM H001-BAM H010 was investigated. The materials consist of an acrylonitryle-butadien-styrene terpolymer, doped with different amounts of the elements Br, Cd, Cr, Hg and Pb. For the quantitative determination of the degree of homogeneity, a procedure proposed by Kempenaers et al. (Fresenius J. Anal. Chem., 2001, 369, 733-737) was used. On every sample an extensive number of different points were analyzed and standard deviation for every element mentioned above was used to calculate a minimal sampling mass that is necessary to reach a certain level of uncertainty caused by inhomogeneity (mmin,5%). The experiments were taken out with synchrotron µ-XRF (SR µ-XRF) at BESSYII in Berlin and by laser ablation inductively coupled plasma mass spectroscopy (LA-ICP-MS). The calculated values for mmin,5% of both techniques showed comparable results for all elements. It could be shown that the materials are suitable for calibration of micro analytic techniques if at least 64 µg are used. KW - XRF KW - LA-ICP-MS KW - RoHS KW - CRM PY - 2010 U6 - https://doi.org/10.1039/b917008a SN - 0267-9477 SN - 1364-5544 VL - 25 SP - 40 EP - 43 PB - Royal Society of Chemistry CY - London AN - OPUS4-20938 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Recknagel, Sebastian A1 - Michaelis, Matthias T1 - Certification of the mass fractions of Pt, Pd and Rh in a used car catalyst reference material N2 - The high economic value of catalysts containing the platinum group elements platinum, rhodium and palladium as active components causes the need to be able to measure the precious metal loading with small uncertainty and to have suitable certified reference materials fulfilling high demands on the quality of the certified values. In European Reference Material ERM®-EB504, a used cordierite-based car catalyst material, mass fractions of platinum, palladium and rhodium were certified. The raw material was milled, homogenised and annealed before analysis. Seventeen laboratories experienced in precious metals analysis participated in the certification interlaboratory comparison, most of them analysing with inductively coupled plasma optical emission spectrometry using different sample pretreatment techniques. Homogeneity testing was carried out using X-ray fluorescence spectrometry. The certified mass fractions of Pt, Pd and Rh and their expanded uncertainties (k = 2) in ERM®-EB504 are (1777 ± 15), (279 ± 6) and (338 ± 4) mg/kg respectively. KW - Precious metals KW - CRM KW - European reference material KW - Platinum KW - Rhodium KW - Palladium KW - ICP OES PY - 2009 U6 - https://doi.org/10.1007/s00769-009-0508-9 SN - 0949-1775 SN - 1432-0517 VL - 14 IS - 5 SP - 277 EP - 280 PB - Springer CY - Berlin AN - OPUS4-19349 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -