TY - JOUR A1 - Mantouvalou, I. A1 - Wolff, Timo A1 - Hahn, Oliver A1 - Rabin, Ira A1 - Lühl, Lars A1 - Pagels, M. A1 - Malzer, W. A1 - Kanngiesser, B. T1 - 3D Micro-XRF for cultural heritage objects: new analysis strategies for the investigation of the Dead Sea scrolls N2 - A combination of 3D micro X-ray fluorescence spectroscopy (3D micro-XRF) and micro-XRF was utilized for the investigation of a small collection of highly heterogeneous, partly degraded Dead Sea Scroll parchment samples from known excavation sites. The quantitative combination of the two techniques proves to be suitable for the identification of reliable marker elements which may be used for classification and provenance studies. With 3D micro-XRF, the three-dimensional nature, i.e. the depth-resolved elemental composition as well as density variations, of the samples was investigated and bromine could be identified as a suitable marker element. It is shown through a comparison of quantitative and semiquantitative values for the bromine content derived using both techniques that, for elements which are homogeneously distributed in the sample matrix, quantification with micro-XRF using a one-layer model is feasible. Thus, the possibility for routine provenance studies using portable micro-XRF instrumentation on a vast amount of samples, even on site, is obtained through this work. KW - Archaeometry KW - 3D X-ray spectroscopy PY - 2011 U6 - https://doi.org/10.1021/ac2011262 SN - 0003-2700 SN - 1520-6882 VL - 83 IS - 16 SP - 6308 EP - 6315 PB - American Chemical Society CY - Washington, DC AN - OPUS4-25209 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hahn, Oliver A1 - Wolff, Timo A1 - Kanngießer, B. A1 - Malzer, W. A1 - Mantouvalou, I. T1 - Non-destructive investigation of the scroll material: "4QComposition concerning divine providence" (4Q413) KW - X-ray fluorescence analysis KW - Cultural heritage PY - 2007 SN - 0929-0761 SN - 1568-5179 VL - 14 IS - 3 SP - 359 EP - 364 PB - Brill CY - Leiden AN - OPUS4-16087 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kanngießer, B. A1 - Mantouvalou, I. A1 - Malzer, W. A1 - Wolff, Timo A1 - Hahn, Oliver T1 - Non-destructive, depth resolved investigation of corrosion layers of historical glass objects by 3D Micro X-ray fluorescence analysis N2 - 3D Micro X-ray fluorescence analysis was used for the investigation of reverse-glass paintings. The material-specific combination used in reverse-glass paintings leads to damage phenomena reinforced by glass corrosion. To elucidate the mechanism of corrosion processes taking place in the glass object depth profiles of mobile elements are of interest. In order to obtain elemental depth profiles of such kind of fragile objects the method of choice should be non-destructive. Our first results demonstrate the usefulness of the 3D Micro-XRF measurements for this kind of investigations. The assumption that certain binding media may initiate corrosion processes beginning at the interface glass/binding material could be confirmed. KW - Cultural heritage KW - 3D-micro XRF KW - Glass corrosion KW - Quantification PY - 2008 U6 - https://doi.org/10.1039/b717286a SN - 0267-9477 SN - 1364-5544 VL - 23 SP - 814 EP - 819 PB - Royal Society of Chemistry CY - London AN - OPUS4-17544 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mantouvalou, I. A1 - Lange, K. A1 - Wolff, Timo A1 - Grötzsch, D. A1 - Lühl, Lars A1 - Haschke, M. A1 - Hahn, Oliver A1 - Kanngießer, B. T1 - A compact 3D micro X-ray fluorescence spectrometer with X-ray tube excitation for archaeometric applications N2 - In this work, the applicability of a new 3D micro X-ray fluorescence (3D Micro-XRF) laboratory spectrometer for the investigation of historical glass objects is demonstrated. The non-destructiveness of the technique and the possibility to measure three-dimensionally resolved fluorescence renders this technique into a suitable tool for the analysis of cultural heritage objects. Although absorption and resolution effects complicate qualitative analysis of the data, layered structures can be distinguished from homogeneous samples without the need for full quantification. Different manufacturing techniques were studied in this work with the help of hand-made reference samples. With the gained knowledge it could be shown for the investigated historical glass object, that black enamel as a stained glass contour colour was used in a cold painting. The object was not fired after the application of the black enamel, but instead the adhesion of the paint was solely provided through organic binding agents and the backing with metal foils. Thus, for the manufacturing of the object, a mixture of cold painting technique with a stained glass color was used. Quantitative measurements with a 3D Micro-XRF setup at the Berlin synchrotron BESSY II confirm the assumptions drawn on the basis of the qualitative investigation with the 3D Micro-XRF spectrometer with X-ray tube excitation. KW - 3D micro XRF KW - Archaeometry KW - Non-destructive testing KW - Cultural heritage PY - 2010 U6 - https://doi.org/10.1039/b915912f SN - 0267-9477 SN - 1364-5544 VL - 25 SP - 554 EP - 561 PB - Royal Society of Chemistry CY - London AN - OPUS4-20878 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lühl, Lars A1 - Mantouvalou, I. A1 - Malzer, W. A1 - Schaumann, I. A1 - Vogt, C. A1 - Hahn, Oliver A1 - Kanngiesser, B. T1 - Reconstruction procedure for 3D micro X-ray absorption fine structure N2 - A new approach for chemical speciation in stratified systems using 3D Micro-XAFS spectroscopy is developed by combining 3D Micro X-ray Fluorescence Spectroscopy (3D Micro-XRF) and conventional X-ray Absorption Fine Structure Spectroscopy (XAFS). A prominent field of application is stratified materials within which depth-resolved chemical speciation is required. Measurements are collected in fluorescence mode which in general lead to distorted spectra due to absorption effects. Developing a reliable reconstruction algorithm for obtaining undistorted spectra for superficial and in-depth layers is proposed and validated. The developed algorithm calculates the attenuation coefficients of the analyte for the successive layers facilitating a new spectroscopic tool for three-dimensionally resolved nondestructive chemical speciation. KW - X-ray absorption fine structure KW - 3D X-ray fluorescence analysis PY - 2012 U6 - https://doi.org/10.1021/ac202285d SN - 0003-2700 SN - 1520-6882 VL - 84 IS - 4 SP - 1907 EP - 1914 PB - American Chemical Society CY - Washington, DC AN - OPUS4-26941 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Margreiter, R. A1 - Baumann, J. A1 - Mantouvalou, I. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Strub, E. T1 - Investigations on fire-gilding N2 - Fire-gilding is a historic technique for the application of golden layers on a number of different base materials utilizing a gold amalgam. This technique leaves a significant amount of Hg in the golden layer, giving archeometrists a reliable indicator to identify firegildings. Recent findings on presumably fire-gilded objects have shown in several cases significantly lower Hg content than previously studied objects. This prompted a synchrotron-based X-ray fluorescence investigation into the Hg distribution along the material–gilding interface, as well as a series of measurements regarding the Hg content development in fire-gilded samples during artificial aging. This work presents findings on laboratory-prepared fire-gildings, indicating an Hg enrichment at the interface of firegilded silver samples. Notably, such an enrichment is missing in fire-gilded copper samples. Further, it is confirmed that fire-gilded layers typically do not undercut an Hg bulk content of 5%. In this light, it seems improbable that ancient samples that contain <5% Hg are fire-gilded. The results presented in this study might lead to a non-destructive method to identify the Hg enrichment at the interface. This might be obtained by a combination of different non-destructive measurements and might also work unambiguously in samples in which the gold top layer is altered. KW - BAMline KW - X-Ray Fluorescence KW - Gilding KW - Depth profile KW - Archaeometry PY - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-552885 SN - 0003-813X SP - 1 EP - 14 PB - Wiley online library AN - OPUS4-55288 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bjeoumikhov, A. A1 - Erko, M. A1 - Bjeoumikhova, Zemfira A1 - Erko, A. A1 - Snigireva, I. A1 - Snigirev, A. A1 - Wolff, Timo A1 - Mantouvalou, I. A1 - Malzer, W. A1 - Kanngießer, B. T1 - Capillary µFocus X-ray lenses with parabolic and elliptic profile KW - Synchrotron radiation KW - Capillary optics KW - Beamline optics PY - 2008 U6 - https://doi.org/10.1016/j.nima.2008.01.087 SN - 0168-9002 SN - 0167-5087 VL - 587 IS - 2-3 SP - 458 EP - 463 PB - North-Holland CY - Amsterdam AN - OPUS4-18922 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wolff, Timo A1 - Mantouvalou, I. A1 - Malzer, W. A1 - Nissen, J. A1 - Berger, D. A1 - Zizak, I. A1 - Sokaras, D. A1 - Karydas, A. A1 - Grlj, N. A1 - Pelicon, P. A1 - Schütz, R. A1 - Zitniki, M. A1 - Kanngießer, B. T1 - Performance of a polycapillary halflens as focussing and collecting optic - a comparison N2 - Polycapillary halflenses are widely used to focus X-ray radiation onto a small spot. Additionally they can reduce the field of view of a semiconductor detector when placed in front of one. In 3D micro X-ray fluorescence spectroscopy (3D Micro-XRF) with synchrotron radiation, two polycapillary halflenses are used in a confocal geometry. Up until now, characterization measurements in the focal plane have only been performed in the case of the lens focusing parallel radiation. Assumptions have been made, that in the other case, when isotropic radiation from a spot source is transported to a detector, the acceptance distribution in the focal plane is also Gaussian. We performed measurements with an electron beam as well as a proton beam which confirm this assumption. In addition, a comparison between measurements in collecting and focusing mode show differences in spot size and transmission. These differences exemplify the fact that there is not one global spot size or transmission function of a polycapillary halflens. Illumination and divergence effects can alter both characteristic lens parameters. PY - 2009 U6 - https://doi.org/10.1039/b817828c SN - 0267-9477 SN - 1364-5544 VL - 24 SP - 669 EP - 675 PB - Royal Society of Chemistry CY - London AN - OPUS4-19415 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wolff, Timo A1 - Malzer, W. A1 - Mantouvalou, I. A1 - Hahn, Oliver A1 - Kanngießer, B. T1 - A new fundamental parameter based calibration procedure for micro X-ray fluorescence spectrometers N2 - Fundamental parameter based quantification of X-ray fluorescence (XRF) measurement data requires an accurate knowledge of the spectrometer parameters, including the spectral distribution of the excitation radiation. In case of micro-XRF where a polycapillary optic is utilized in the excitation channel this distribution is changed due to the transmission properties of the lens. A new calibration procedure, based on fluorescence data of thin standard samples, was developed to determine the excitation spectrum, i.e., the product of the X-ray tube spectrum and the transmission of the used X-ray optic of a micro-XRF setup. The calibration result was validated by the quantitative analyses of certified multi-element reference standards and shows uncertainties in the order of 2% for main components, 10% for minor elements and 25% for trace elements. The influence of secondary order effects like Coster–Kronig transitions and cascade effects is analyzed and the accuracy of fundamental parameters in common databases is discussed. KW - Polycapillary optic KW - Transmission KW - Micro-XRF calibration KW - Reference free quantification PY - 2011 U6 - https://doi.org/10.1016/j.sab.2011.01.009 SN - 0584-8547 SN - 0038-6987 VL - 66 IS - 2 SP - 170 EP - 178 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-24213 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Grötzsch, D. A1 - Streeck, C. A1 - Nietzold, Carolin A1 - Malzer, W. A1 - Mantouvalou, I. A1 - Nutsch, A. A1 - Dietrich, Paul A1 - Unger, Wolfgang A1 - Beckhoff, B. A1 - Kanngießer, B. T1 - A sealable ultrathin window sample cell for the study of liquids by means of soft X-ray spectroscopy N2 - A new sample cell concept for the analysis of liquids or solid-liquid interfaces using soft X-ray spectroscopy is presented, which enables the complete sealing of the cell as well as the Transport into vacuum via, for example, a load-lock system. The cell uses pressure monitoring and active as well as passive pressure regulation systems, thereby facilitating the full control over the pressure during filling, sealing, evacuation, and measurement. The cell design and sample preparation as well as the crucial sealing procedure are explained in detail. As a first proof-of-principle experiment, successful nitrogen K-edge fluorescence yield near-edge X-ray absorption fine structure experiments of a biomolecular solution are presented. For this purpose, it is shown that the careful evaluation of all involved parameters, such as window type or photon flux, is desirable for optimizing the experimental result. KW - X-ray spectroscopy KW - Analysis of liquids KW - Wet cell KW - Concanavalin A KW - NEXAFS PY - 2017 U6 - https://doi.org/10.1063/1.5006122 SN - 0034-6748 SN - 1089-7623 VL - 88 IS - 12 SP - 123112-1 EP - 123112-7 PB - American Institute of Physics AN - OPUS4-43611 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -