TY - CONF A1 - Mair, Georg A1 - Becker, Ben A1 - Duffner, Eric A1 - John, Sebastian T1 - Composite storage systems for CGH2- systematic improvement of RC&S N2 - Conventional approval requirements exclusively ask for minimum strength values, which have to be met. The probabilistic approach estimates how likely none of the comparatively manufactured units fails during operation. Both questions are juxtaposed and compared here with respect to the load cycle tests. The influence of the sample sizes is discussed additionally. T2 - 10th INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY & ENVIRONMENTAL PROTECTION CY - Bled, Slovenia DA - 27.06.2017 KW - Probabilistic KW - Hydrogen KW - Composite KW - Cylinder KW - Regulations KW - Load cycles KW - GTR 13 PY - 2017 AN - OPUS4-41677 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -