TY - CONF A1 - Mair, Georg W. A1 - Becker, Ben A1 - Duffner, Eric A1 - John, Sebastian T1 - Composite storage systems for CGH2- systematic improvement of RC&S N2 - Conventional approval requirements exclusively ask for minimum strength values, which have to be met. The probabilistic approach estimates how likely none of the comparatively manufactured units fails during operation. Both questions are juxtaposed and compared here with respect to the load cycle tests. The influence of the sample sizes is discussed additionally. T2 - 10th INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY & ENVIRONMENTAL PROTECTION CY - Bled, Slovenia DA - 27.06.2017 KW - Probabilistic KW - Hydrogen KW - Composite KW - Cylinder KW - Regulations KW - Load cycles KW - GTR 13 PY - 2017 AN - OPUS4-41677 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - John, Sebastian A1 - Mair, Georg W. T1 - Sensitivity analysis of residual stresses in composite pressure vessels via modal analysis N2 - Due to high specific stiffness a nd strength properties, fibre reinforced plastics are used more and more often for the construction of pressure vessels. Within a recent research project run by the Federal Institute for Materials Research and Testing (BAM), aging process of composite pressure vessels is investigated in order to be able to give more accurate lifetime predictions in the future. Focus is set on type III pressure vessels consisting of an aluminium tank which is fully wrapped with carbon fibre reinforced plastics. In order to increase high-cycle fatigue, residual stresses are induced into the pressure vessel during manufacturing process. In particular, residual compressive stresses within the inner aluminium layer have been defined as a main parameter affecting fatigue strength. The aim is to identify and evaluate residual stresses of the pressure vessel by analysing its modal parameters. Through the set-up of a finite-element model potential capability and validity for the use of modal analysis is proven and evaluated, considering influences resulting from manufacturing deviations, too. In the following, a number of stress sensitive modes are defined. Based on these preliminary numerical investigations, a test bench is set up in order to measure pressure vessels via an experimental modal analysis. A final critical evaluation regarding the accuracy of the modal analysis is made by comparing experimental results with data obtained through simulations. T2 - INTER-NOISE 2017 46th International Congress and Exposition on Noise Control Engineering CY - Hong Kong, People's Republic of China DA - 27.08.2017 KW - Composite pressure vessel KW - Modal analysis PY - 2017 SP - 6309 EP - 6316 CY - Hong Kong AN - OPUS4-41842 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mair, Georg W. A1 - Becker, Ben A1 - John, Sebastian A1 - Duffner, Eric T1 - Composite storage systems for compressed hydrogen - systematic improvement of regulations for more attractive storage units N2 - Hydrogen is an attractive energy carrier that requires high effort for safe storage. For ensuring safety, they must undergo a challenging approval process. Relevant standards and regulations for composite cylinders used for the transport of hydrogen and for its onboard storage are currently based on deterministic (e.g. ISO 11119-3) or semi-probabilistic (UN GTR No. 13) criteria. This paper analysis the properties of such methods with respect to the evaluation of load cycle strength. Their characteristics are compared with the probabilistic approach of the BAM. Based on Monte-Carlo simulations, the available design range (mean value and scatter of strength criteria) of current concepts was exemplarily estimated. The aspect of small sample sizes is analysed and discussed with respect to the evaluation procedures. KW - Probabilistic KW - Monte-Carlo KW - Regulations KW - Composite cylinder KW - Hydrogen vehicles KW - Transport of dangerous goods PY - 2018 DO - https://doi.org/10.1016/j.ijhydene.2018.04.068 SN - 0360-3199 VL - 45 IS - 25 SP - 13672 EP - 13679 PB - Elsevier Ltd AN - OPUS4-46856 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - John, Sebastian A1 - Mair, Georg W. A1 - Schoppa, André A1 - Szczepaniak, Mariusz T1 - Monitoring of residual stresses in composite pressure vessels via modal analysis N2 - Within a current research project at the Federal Institute for Materials Testing and Research (BAM), the degradation process of composite pressure vessels is studied to be able to give more accurate lifetime predictions in future. The presented research is based on type III pressure vessels consisting of an aluminium tank which is fully wrapped with carbon fibre reinforced plastics. Focus is set on the analysis of residual stresses which are induced into the pressure vessel during manufacturing process in order to increase high cycle fatigue. However, with increasing lifetime residual stress conditions do change. To be able to measure and monitor stress conditions, the application of a non-destructive measurement method is aspired. In this paper, potential of an experimental modal analysis is worked out to capture and monitor aging and degradation effects in pressure vessels. With the presented method, information about changes in residual stress can be obtained via an analysis of the modal parameters. To realize an application, first, a finite element simulation is used to prove and evaluate potential capability and validity. In the following, a test bench is set up and successively optimized in its accuracy and efficiency. Sensitivity of the applied measurement technique is experimentally ascertained trough the measurement of several prestress modified pressure vessels. Finally, experimental results are interpreted and evaluated with the help of numerically gained findings. T2 - NOVEM 2018 CY - St. Eulalia, Ibiza, Spain DA - 07.05.2018 KW - Composite pressure vessel KW - Residual stress KW - Modal analysis PY - 2018 VL - 6 SP - Paper 175090, 1 EP - 9 AN - OPUS4-45220 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - John, Sebastian A1 - Eisermann, René A1 - Mair, Georg W. T1 - Application of an experimental modal analysis on composite pressure vessels for monitoring prestress conditions N2 - Due to high specific stiffness, fibre reinforced plastics are the dominant material group for the design of mobile pressure vessels. At the Federal Institute of Materials Research and Testing (BAM) aging process of composite pressure vessels is studied to be able to give more accurate lifetime predictions in future. Investigations are based on type III breathing air cylinders consisting of an aluminium tank which is fully wrapped with carbon fibre reinforced plastics. Goal is to detect changes of residual stresses over life time which directly affect fatigue strength. Within this paper an approach is presented to monitor residual stresses via an experimental modal analysis (EMA). First, the influence of changed stress conditions on modal parameters is analysed via a numerical study. Secondly, a test bench for an EMA is set up. To be able to analyse cylinders of different prestress condition, several specimens are prestress modified via high-temperature and high-pressure treatment. During modification processes, specimens are monitored via optical fibres to control prestress modifications. Through experimental measurements of the modified specimens via EMA changes in prestressing can be detected. Finally, validity and accuracy of the EMA is evaluated critically by comparing all numerically and experimentally obtained data. T2 - INTERNOISE 2018 CY - Chicago, Illinois, USA DA - 25.08.2018 KW - Modal analysis KW - Residual stress KW - Composite KW - Pressure vessel PY - 2018 SN - 978-0-7918-5142-5 SP - 6143, 1 EP - 10 AN - OPUS4-46329 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mair, Georg W. A1 - Becker, B. A1 - John, Sebastian A1 - Duffner, Eric T1 - Composite storage systems for compressed hydrogen - systematic improvement of regulations for more attractive storage units N2 - Hydrogen is an attractive energy carrier that requires high effort for safe storage. Forensuring safety, they must undergo a challenging approval process. Relevant standardsand regulations for composite cylinders used for the transport of hydrogen and for its on-board storage are currently based on deterministic (e.g. ISO 11119-3) or semi-probabilistic(UN GTR No. 13) criteria. This paper analysis the properties of such methods withrespect to the evaluation of load cycle strength. Their characteristics are compared withthe probabilistic approach of the BAM. Based on Monte-Carlo simulations, the availabledesign range (mean value and scatter of strength criteria) of current concepts was exem-plarily estimated. The aspect of small sample sizes is analysed and discussed with respectto the evaluation procedures. KW - Probabilistic KW - Monte-Carlo KW - Regulations KW - Composite cylinder KW - Hydrogen vehicles KW - Transport of dangerous goods PY - 2020 DO - https://doi.org/10.1016/j.ijhydene.2018.04.068 SN - 0360-3199 VL - 45 IS - 25 SP - 13672 EP - 13679 PB - Elsevier Ltd. AN - OPUS4-50687 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - John, Sebastian A1 - Duffner, Eric A1 - Mair, Georg W. T1 - Degradation and damage analysis of composite pressure vessels via experimental modal analysis N2 - For mobile gas storage systems, the application of type IV pressure vessels is state of the art. Type IV tanks consist of an inner polymer liner fully wrapped with fibre-reinforced plastic (FRP). Because of the complex fabric of the FRP as well as a difficulty estimable interaction behaviour between the single components under load, there are still no satisfying non-destructive testing methods to assess the current state of failure nor to estimate the level of degradation accurately and economically. At BAM division 3.5, analysing the ageing process of mobile composite pressure vessels is a major task to ensure safe usage over the whole lifetime. In this context, key aspects of our ongoing research activities are the invention of new test procedures and the development of accurate lifetime prediction models. In order to determine the level of degradation or damage, one meaningful non-destructive approach is to analyse the structural dynamic behaviour via an experimental modal analysis (EMA). Over the last few years, different types and sizes of composite pressure vessels have been tested in several research projects. The presented paper gives an insight into how to extract and interpret modal parameters and how to fit them to the results of residual strength tests. T2 - NOVEM Conference 2023 CY - Auckland, New Zealand DA - 09.01.2023 KW - Composite material KW - Pressure vessel KW - Degradation KW - Modal analysis PY - 2023 SP - 57-1 EP - 57-6 AN - OPUS4-58062 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eisermann, René A1 - Basedau, Frank A1 - Kadoke, Daniel A1 - Gründer, Peter A1 - Schoppa, André A1 - Lehr, Christian A1 - Szczepaniak, Mariusz A1 - John, Sebastian A1 - Schukar, Marcus A1 - Munzke, Dorit A1 - Mair, Georg W. T1 - Distributed strain sensing with sub-centimetre resolution for the characterisation of structural inhomogeneities and material degradation of industrial high-pressure composite cylinders N2 - Fibre-reinforced plastics (FRP) especially carbon-fibre-reinforced polymer (CFRP) and glass-fibre-reinforced polymer (GFRP) are commonly used materials in high pressure vessels and storage units for automotive and aerospace purposes. Optical fibres are suitable to be integrated or directly applied to the surface of FRP components. Using optical fibres it is possible to monitor the distributed strain profiles and changes within the fatigue life of a pressure vessel to ensure the operational safety. Within artificial ageing experiments we used swept wavelength interferometry (SWI) based distributed strain sensing for the monitoring of commercial high-pressure composite cylinder. This artificial ageing was performed using test conditions of 503bar pressure load (service pressure 300 bar) and 89 °C for 100 h. The polyimide coated optical fibres were glued to the surface externally in circumferential and axial direction. Using distributed strain sensing (DSS) material expansion of over 0.5% were monitored with sub-centimetre spatial resolution. Within the circumferential direction we observed up to 10 % local fluctuation compared to the median strain caused by inhomogeneous material expansion, which could cause local material fatigue. In addition, we determined material degradation manifested itself as localized remaining material expansion and/or contraction. Results have been validated by other non-destructive methods like digital strip projection. T2 - 9th European Workshop on Structural Health Monitoring (EWSHM) CY - Manchester, UK DA - 10.07.2018 KW - Distributed fibre optic sensors KW - Optical backscatter reflectometry KW - Swept wavelength interferometry (SWI) KW - Structural health monitoring (SHM) KW - Composite structures KW - Optical fibre PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-458926 SP - 1 EP - 8 AN - OPUS4-45892 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Duffner, Eric A1 - el Dsoki, Chalid A1 - John, Sebastian A1 - Schmidt, Anita A1 - Mair, Georg W. A1 - Loechner, Derek A1 - Drousch, Björn T1 - Sicherheitstechnische Bewertung thermischer Betriebsbelastung auf sicherheitskritische Ausrüstung am Beispiel von Composite-Atemluftflaschen und Lithiumbatterien N2 - Ziel des Vorhabens war es, den Einfluss der realen Temperaturbelastung auf Atemschutzflaschen und Lithiumbatterien in Funkgeräten (FG) im Löscheinsatz von Rettungskräften zu ermitteln und deren Auswirkung auf die Alterung und Lebensdauer sowie die potenziellen Gesundheitsgefahren bei deren Nutzung besser beurteilen zu können und Handlungshilfen abzuleiten. Im Rahmen dieses Vorhabens wurden zum einen unterschiedlich thermisch gealterte Composite-Atemluftflaschen systematisch hinsichtlich ihrer Restfestigkeiten untersucht. Zum anderen wurden Lithiumbatterien aus FG hinsichtlich der Einwirkung von kritischen Temperaturen untersucht, ab denen es zu einem thermischen Durchgehen der Batterien kommen kann. Für diese beiden wichtigen Komponenten, Lithiumbatterien und Composite-Atemluftflaschen, wurden kritische Temperatur-Zeit-Profile ermittelt, die Auswirkungen durch geeignete Methodiken untersucht und die sich ergebenden Gefährdungen für den Träger bewertet. Als Methodische Vorgehensweise wurden durch Realversuche die tatsächlichen und zuvor durch Literatur-recherche ermittelten Temperaturprofile verifiziert und auf deren Grundlage die Laborbelastungen abgeleitet. Um den Eigenschaften der aus Faserverbundwerkstoffen hergestellten Composite-Atemluftflaschen Rechnung zu tragen, wurden an zwei repräsentativen Baumustern unterschiedlicher Hersteller Stichprobengruppen unterschiedlicher thermischer Belastung ausgesetzt und hinsichtlich ihrer verbleibenden Restfestigkeitsabnahme geprüft und mit thermisch unbelasteten Baumustern verglichen. Neben den statischen Berstversuchen wurden auch kombinierte Alterungs- und Restfestigkeitsuntersuchungen an zyklisch belasteten Behältern durchgeführt. Die FG wurden thermisch sowohl statischen als auch zyklischen Belastungen ausgesetzt und mit Kapazitätsmessungen begleitet. Die statischen Versuche dienten dem Zweck, die maximale thermische Belastbarkeit der Akkus zu ermitteln, bei der noch kein Versagen auftritt. Bei den zyklischen Versuchen wurde der Temperaturverlauf bei Löscheinsätzen so nah wie möglich im Labor nachgestellt. Hierbei wurden die Akkus wiederholt einem Belastungsprofil mit konstanter Temperatur ausgesetzt und nach einigen Intervallen die Restkapazitäten am Akku gemessen und so die Degradation bestimmt. Als Fazit der im Rahmen dieses Vorhabens durchgeführten Untersuchungen an zwei repräsentativen Baumustern von Atemschutzflaschen kann gefolgert werden, dass die thermischen Belastungen abhängig vom Baumuster einen z.T. deutlichen Einfluss auf die Restfestigkeiten der Atemschutzflaschen haben. Höhere thermische Exposition ist, zumindest an den untersuchten Atemschutzflaschen, deutlich zu erkennen und die Flaschen können durch die zuständigen Gerätewarte leicht ausgesondert und ersetzt werden. Die thermischen Belastungen, wie sie im Rettungseinsatz auftreten, waren für die untersuchten Atemschutzflaschen und die Rettungskräfte nicht kritisch sind. Die langjährige Erfahrung etablierter Hersteller dürfte hier aber nicht ohne Einfluss sein. Es ist somit kein Grund erkennbar, von der Verwendung der leichteren Typ 4 Atemschutzflaschen abzuraten, wenn Atemschutzflaschen, die visuell erkennbare thermische Einwirkungen (Farbänderungen, Materialschmelzungen o.ä.) aufweisen, unmittelbar ersetzt werden. Die Ergebnisse an den FG zeigen, dass trotz hoher Temperaturen keine Selbstentzündung der Lithiumbatterien ausgelöst wird. Der Kapazitätsverlust der Batterien infolge der Belastung führt ebenfalls nicht zu einem Funktionsausfall. Es konnte gezeigt werden, dass die Kapazitätsbestimmung als zuverlässiges und geeignetes Kriterium für die Sicherheitsbewertung der Akkus herangezogen werden kann, wenn die Kapazitätsmessung bei gleichbleibenden Bedingungen (gleiche Raumtemperaturen, gleiche Messgeräte, etc.) stattfindet. Es wird empfohlen, die Akkus ab einer Restkapazität von unter 80% zu tauschen. Als schnelle und sehr einfache Überprüfung kann eine Sichtprüfung an den FG stattfinden. Die im Projekt verwendeten FG zeigten eine Verformung der Kunststoffhülle bei zu hohen Belastungen. N2 - The aim of the project was to determine the influence of the real temperature load on breathing apparatus cylinders and Lithium batteries in radio devices in firefighting operations by rescue services and to be able to better assess their effect on ageing and service life time as well as the potential health hazards and to derive guidelines for action. As part of this project, composite breathing air cylinders that had undergone different thermal ageing processes were systematically analysed with regard to their residual strength. as a second use case, lithium batteries used in radio devices were analysed with regard to the effect of critical temperatures above which thermal runaway of the batteries can occur. Critical temperature-time profiles were determined for these two important components, lithium batteries and composite breathing air cylinders, the effects for the user were analysed using suitable methods and the resulting hazards for the wearer were assessed. As a methodical approach, the actual temperature profiles previously determined by literature research were first verified in real tests and the laboratory loads were derived on this basis. In order to take into account the properties of composite breathing air cylinders made of fibre composites, sample groups were subjected to different thermal loads and examined with regard to their residual strength reduction and in comparison to thermally unloaded samples from two representative samples from different manufacturers. In addition to the static burst tests, combined ageing and residual strength tests were also carried out on cyclic loaded cylinders. The radio devices were subjected to both static and cyclic thermal loads with accompanying capacity measurements. The purpose of the static tests was to determine the maximum thermal load capacity of the batteries at which no failure occurs. In the cyclic tests, practical conditions were simulated as closely as possible in the laboratory. For this purpose, the batteries were repeatedly subjected to a load profile at a constant temperature and the residual capacity of the battery was measured after several intervals to determine the degradation. As a conclusion of the tests carried out on two representative types of breathing apparatus cylinders as part of this project, it can be concluded that the thermal loads have a sometimes significant influence on the residual strength of the breathing apparatus cylinders, depending on the type. Higher thermal exposure is clearly recognizable, at least on the breathing apparatus cylinders tested, and the cylinders can be easily remove and replaced by the responsible equipment maintainers. The thermal loads that occur during rescue operations were not critical for the tested breathing protection cylinders and the rescue teams. However, the many years of experience of established manufacturers should not be without influence here. There is therefore no reason to advise against the use of the lighter Type 4 breathing protection breathing apparatus cylinders if cylinders with visually recognizable thermal effects (color changes, material melting, etc.) are replaced immediately. The results on the radio devices showed that determination of the capacity can serve as a suitable criterion for the safety assessment for the batteries. The loss of capacity of the batteries as a result of the load also does not lead to a functional failure. The capacity determination can be used as a reliable and suitable criterion for the safety assessment of the batteries if the capacity measurement is carried out under constant conditions (same room temperatures, same measuring devices, etc.). It is recommended to replace the batteries when the remaining capacity is below 80%. A visual inspection of the radio devices can be carried out as a quick and very simple check. The radio devices used in the project showed deformation of the plastic casing when subjected to excessive loads. KW - Composite KW - Atemluftflaschen KW - Litiumbatterien KW - Funkgeräte KW - Thermische Belastung KW - Rettungskräfte KW - Feuerwehr KW - PSA KW - DGUV PY - 2024 UR - https://www.dguv.de/ifa/forschung/projektverzeichnis/ff-fp0462.jsp N1 - Abschlussbericht zum Vorhaben mit der Projekt-Nr. FF-FP 0462 (CoLiBri), Laufzeit 01.03.2021–29.02.2024, Bericht vom 15.04.2024 SP - 1 EP - 66 PB - Deutsche Gesetzliche Unfallversicherung (DGUV) CY - Berlin AN - OPUS4-59877 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mair, Georg W. A1 - Becker, Ben A1 - Duffner, Eric A1 - John, Sebastian T1 - Storage systems for CGH2- systematic improvement of RC&s composite storage systems for compressed hydrogen - systematic improvement of regulations for more attractive storage units N2 - Hydrogen is an attractive energy carrier that requires high effort for safe storage. For ensuring safety they have to undergo a challenging approval process. Relevant standards and regulations for composite cylinders used for the transport of for on-board storage of hydrogen are currently based on deterministic (e.g. ISO 11119-3) or semi-probabilistic (UN GTR No. 13) criteria. This paper analysis the properties of such methods in regards to the evaluation of load cycle strength. Their characteristics are compared with the probabilistic approach of the BAM. Based on Monte-Carlo simulations, the available design range (mean value and scatter of strength criteria) of current concepts were exemplarily estimated. The aspect of small sample sizes is analysed and discussed with respect to the evaluation procedures. T2 - 10th International Conference on Sustainable Energy and Environmental Protection CY - Bled, Slovenia DA - 27.06.2017 KW - Probabilistic KW - Hydrogen KW - Composite KW - Cylinder KW - Regulations KW - Load cycles KW - GTR 13 KW - ISO 11119 PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-416820 SN - 978-961-286-054-7 DO - https://doi.org/10.18690/978-961-286-054-7 SP - 1 EP - 10 PB - University of Maribor Press CY - Maribor, Slovenia AN - OPUS4-41682 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -