TY - GEN A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Schors, Jörg A1 - Wald, Oliver ED - Geer, R. T1 - X-Ray Diffraction Topography images materials by molecular probe T2 - Testing, Reliability, and Application of Micro- and Nano-Material Systems II CY - San Diego, CA, USA DA - 2005-03-08 KW - X-ray diffraction KW - X-ray topography KW - X-ray microscopy KW - Texture KW - Polymers KW - Composites KW - Ceramics KW - Compounds KW - Molecular probe KW - Non-metallics PY - 2005 SN - 0-8194-5747-7 N1 - Serientitel: SPIE proceedings series – Series title: SPIE proceedings series IS - 5766 SP - 9 EP - 14 PB - SPIE CY - Bellingham AN - OPUS4-11700 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schors, Jörg A1 - Harbich, Karl-Wolfram A1 - Hentschel, Manfred P. A1 - Lange, Axel T1 - Non-Destructive Micro Crack Detection in Modern Materials T2 - 9th European Conference on NDT CY - Berlin, Germany DA - 2006-09-25 KW - X-ray KW - Refraction KW - Micro cracks KW - Inner surface KW - Topography KW - Composites PY - 2006 SN - 3-931381-86-2 SP - 1(?) EP - 5(?) PB - European Federation for Non-Destructive Testing CY - Berlin AN - OPUS4-14040 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Schors, Jörg T1 - Direct Iterative Reconstruction of Computed Tomography Trajectories (Direct) T2 - 9th European Conference on NDT CY - Berlin, Germany DA - 2006-09-25 KW - Computerised tomography KW - Reconstruction algorithm KW - Iterative CT reconstruction PY - 2006 SN - 3-931381-86-2 SP - 1 EP - 8(?) PB - European Federation for Non-Destructive Testing CY - Berlin AN - OPUS4-14041 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Schors, Jörg T1 - NDE of Micro Structured Materials By X-Ray Diffraction and Refraction Topography T2 - 9th European Conference on NDT CY - Berlin, Germany DA - 2006-09-25 KW - X-ray scattering topography KW - Nondestructive materials characterisation KW - Composites KW - Ceramics KW - Foams PY - 2006 SN - 3-931381-86-2 SP - 1(?) EP - 8(?) PB - European Federation for Non-Destructive Testing CY - Berlin AN - OPUS4-14042 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel T1 - Direct Iterative Reconstruction of Computed Tomography Trajectories (Direct) T2 - 9th European Conference on NDT CY - Berlin, Germany DA - 2006-09-25 PY - 2006 AN - OPUS4-14024 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel T1 - Direct iterative reconstruction of computed tomography trajectories (DIRECTT) T2 - ETECH-NDT, 4 th Int. Conf. on Emerging Technologies in NDT CY - Stuttgart, Germany DA - 2007-04-02 PY - 2007 AN - OPUS4-15472 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel T1 - Direct iterative reconstruction of computed tomography trajectories: DIRECTT T2 - International Symposium on Digital Industrial Radiology and Computed Tomography (DIR 2007) CY - Lyon, France DA - 2007-06-25 PY - 2007 AN - OPUS4-15478 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel T1 - Direkte iterative Rekonstruktion von Computer-tomographischen Trajektorien (DIRECTT) T2 - DGZfP-Jahrestagung CY - Fürth, Germany DA - 2007-05-14 PY - 2007 AN - OPUS4-15758 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel A1 - Hentschel, Manfred P. T1 - Direkte iterative Rekonstruktion von computertomographischen Trajektorien (DIRECTT) T2 - DGZfP-Jahrestagung 2007 CY - Fürth, Deutschland DA - 2007-05-14 KW - Computertomographie KW - Rekonstruktionsalgorithmen PY - 2007 SN - 978-3-931381-98-1 SP - 1 EP - 8 PB - DGZfP CY - Berlin AN - OPUS4-15798 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Harbich, Karl-Wolfram A1 - Schors, Jörg ED - Wielage, B. T1 - Neue Möglichkeiten der zerstörungsfreien Charakterisierung von Verbundwerkstoffen mittels Röntgenstreuungs-Topographie T2 - 5. Werkstofftechnisches Kolloquium CY - Chemnitz, Deutschland DA - 2002-10-24 PY - 2002 SN - 1439-1597 N1 - Serientitel: Schriftenreihe Werkstoffe und Werkstofftechnische Anwendungen – Series title: Schriftenreihe Werkstoffe und Werkstofftechnische Anwendungen IS - 11 SP - 132 EP - 139 PB - TU, Lehrstuhl für Verbundwerkstoffe CY - Chemnitz AN - OPUS4-1791 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Harbich, Karl-Wolfram A1 - Schors, Jörg A1 - Wald, Oliver T1 - X-ray diffraction and refraction topography of light weight materials T2 - Annual conference of the British Institute on Non-Destructive Testing ; NDT 2002 CY - Southport, England, UK DA - 2002-09-17 PY - 2002 SN - 0-903132-30-3 SP - 275 EP - 280 PB - British Institute of Non-Destructive Testing CY - Northampton AN - OPUS4-1938 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Harbich, Karl-Wolfram A1 - Hentschel, Manfred P. A1 - Schors, Jörg A1 - Lange, Axel T1 - Röntgen-Refraktions-Topographie - Ein modernes ZfP-Verfahren zur Bewertung von Mikrorissen und Schlagschäden in Verbundwerkstoffen N2 - Röntgen-Topographie-Verfahren werden zunehmend von industriellen Herstellern und Anwendern Neuer Werkstoffe in Anspruch genommen, um deren mikrostrukturelle Eigenschaften zuverlässig und zerstörungsfrei charakterisieren zu können. Der Einsatz umfaßt die Untersuchung unterschiedlichster Materialien wie Kohlenstoff- (CFK) und Glasfaser-Verbunde (GFK), Hart- und Weichschäume, Industriekeramik sowie neuartige Kunststoffe. Gerade die mechanischen und korrosiven Eigenschaften dieser Werkstoffe weser Werkstoffe werden maßgeblich vom mikrostrukturellem Aufbau dieser Materialien bestimmt. Typische Versagensmechanismen z.B. von Faserkompositen sind neben der Faserenthaftung vor allem durch Mikrorisse gekennzeichnet, die aufgrund von Spannungsspitzen an Faserenden enttstehen und sich senkrecht zu diesen in der Matrix ausbreiten. Ein wesentliches Merkmal der Röntgen-Refaktions-Topographie besteht in der orientierungsselektiven Detektion von Mikroriß-Oberflächen. Deren Nachweisgrenze erstreckt sich bis zum Nanometerbereich. Auch die an Kompositmaterialien definiert herbeigeführten Schäden (Impacts) lassen sich mit dieser Methode ausgezeichnet erfassen und in Korrelation zu mechanischen Kenngrößen quantitativ beschreiben. T2 - Jahrestagung Zerstörungsfreie Materialprüfung 1999 CY - Celle, Deutschland DA - 1999-05-10 KW - Röntgentomographie KW - Mikroriß KW - Schlagfestigkeit KW - Verbundwerkstoff PY - 1999 UR - http://www.ndt.net/abstract/dgzfp99/data/p18.htm SN - 3-931381-27-7 VL - 2 IS - 68 SP - 685 EP - 690 PB - DGZfP CY - Berlin AN - OPUS4-714 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Schors, Jörg A1 - Harwardt, Michael T1 - Röntgen-Diffraktions-Rotations-Topographie von polymeren Werkstoffen N2 - Polymere Werkstoffe, insbesondere Faser-Komposite, sind auf der molekularen Skala, aber auch hinsichtlich der Faserorientierung unterschiedlich anisotrop, ebenso ihre mechanischen Eigenschaften. Diese können sich richtungsabhängig um bis zu zwei Größenordnungen unterscheiden, was für die Nutzung der Festigkeit im Leichtbau bedeutend ist. Daher besteht Bedarf an der zerstörungsfreien Charakterisierung der Orientierungs-Parameter der Mikrostruktur: Die neuartige Röntgen-Diffraktions-Rotations-Topographie nutzt (wie alle Röntgen-topographischen Verfahren) einerseits die analytischen Informationen der Röntgenstreuung und erlaubt andererseits die ortsaufgelöste Abbildung dieser Information. Für eine kontinuierliche Erfassung der Orientierungs-Informationen des Probekörpers wird dieser im eng kollimierten monochromatischen Fadenstrahl einer Weitwinkel-Streukammer verfahren. An jeder Position wird das Beugungsbild von einem um den Primärstrahl drehbaren Spalt polar abgetastet, der vor einem großflächigen Röntgen-Detektor positioniert ist. Als Rotations-, Polar- oder Textur-Topogramme werden die Streuintensitäten ortstreu dargestellt. Auswerte-Prozeduren erlauben die Ermittlung von Orientierungs-Verteilungs-Funktionen und statistischen Kennwerten. Untersuchungs-Beispiele aus einem EU-Projekt zeigen die molekularen Orientierungsverteilungen in thermoplastischen Spritzguß-Komponenten für den Helikopter-Bau, mit Korrelationen zu mechanischen Eigenschaften. Für die ESA wurde die für CFK-Sandwich-Strukturen von Satelliten-Reflektoren erforderliche präzise Orientierung der C-Fasern mit einer Genauigkeit von 0,1 Grad ermittelt. Pro Durchstrahlungsposition werden für die Orientierungs-Information nur wenige Sekunden benötigt. Die verwendete 18 keV Mo-k-a-Strahlung erlaubt Wandstärken bis zu etwa 20 mm. T2 - Jahrestagung Zerstörungsfreie Materialprüfung 2000 CY - Innsbruck, Österreich DA - 2000-05-29 PY - 2000 UR - http://www.ndt.net/abstract/dgzfp00/data/39.htm SN - 3-931381-32-3 VL - 73-1 IS - 2 SP - 1 EP - 10 PB - DGZfP CY - Berlin AN - OPUS4-927 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Harbich, Karl-Wolfram A1 - Rabe, Torsten A1 - Mücke, Udo A1 - Lange, Axel T1 - Charakterisierung von Poren in Sinterglaskeramiken KW - Keramik KW - Sinterglas PY - 1994 SN - 0025-5300 VL - 368 IS - 7-8 SP - 303 EP - 305 PB - Carl Hanser Verlag CY - München AN - OPUS4-578 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Harbich, Karl-Wolfram A1 - Lange, Axel A1 - Hentschel, Manfred P. T1 - Quantitative Röntgen-Refraktions-Topographie von keramischen Werkstoffen KW - Röntgen-Refraktions-Topographie KW - Oberfläche, innen KW - Porengröße KW - Keramik KW - Röntgen-Topographie PY - 1996 SN - 0025-5300 VL - 38 IS - 5 SP - 181 EP - 186 PB - Carl Hanser Verlag CY - München AN - OPUS4-677 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schors, Jörg A1 - Lange, Axel A1 - Hentschel, Manfred P. T1 - Non-destructive Inspection of Ceramic/Composite Materials using Non-classical X-Ray Techniques KW - CFRP KW - WAXS KW - XROT KW - FAXOT PY - 1999 IS - ESA CR(P)-4273 SP - 1 EP - 48 PB - BAM CY - Berlin AN - OPUS4-792 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Harbich, Karl-Wolfram A1 - Schors, Jörg A1 - Lange, Axel A1 - Hentschel, Manfred P. ED - van Hemelrijck, D. T1 - X-ray refraction - new methods for non-destructive evaluation of advanced materials T2 - 2nd International Conference on Emerging Technologies in NDT CY - Athens, Greece DA - 1999-05-24 KW - X-ray refraction PY - 2000 SN - 90-5809-127-9 SP - 207 EP - 212 PB - Balkema CY - Rotterdam AN - OPUS4-851 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hentschel, Manfred P. A1 - Harbich, Karl-Wolfram A1 - Lange, Axel A1 - Schors, Jörg A1 - Müller, Bernd R. T1 - Röntgen-Topographie mit Klein- und Weitwinkel-Streuung N2 - Röntgen-Topographische Verfahren sind dadurch gekennzeichnet, daß die Streueigenschaften eines Probekörpers ortskorreliert erfaßt werden. Somit vereinigen sie die Vorzüge der bildgebenden Eigenschaft der Radiographie mit der Strukturselektivität der Röntgenanalyse. Sowohl die Röntgen-Weitwinkel-Streuung als auch die Röntgen-Kleinwinkel-Streuung (-Beugung und -Refraktion) werden topographisch für die Materialcharakterisierung eingesetzt. Die Topographie-Verfahren und Untersuchungsbeispiele an nichtmetallischen Werkstoffen werden dargestellt. T2 - Jahrestagung Zerstörungsfreie Materialprüfung 2002 CY - Weimar, Deutschland DA - 2002-05-06 KW - Röntgen-Streuung KW - Materialcharakterisierung KW - Komposite KW - Keramik PY - 2002 UR - http://www.ndt.net/article/dgzfp02/papers/v15/v15.htm SN - 3-931381-39-0 N1 - Serientitel: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. – Series title: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. IS - 80-CD PB - DGZfP CY - Berlin AN - OPUS4-2027 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Müller, Bernd R. A1 - Schors, Jörg T1 - Das Anwendungspotential der Röntgen-Topographie vom Mikroriss bis zur Gepäckprüfung T2 - DGZfP-Jahrestagung 2007 CY - Fürth, Deutschland DA - 2007-05-14 KW - CFK KW - Bildgebende Röntgenverfahren KW - Röntgen-Topographie und -Streuung KW - Keramik KW - Explosivstoffe KW - Ermüdungsrisse PY - 2007 SN - 978-3-931381-98-1 SP - 1 EP - 9 PB - DGZfP CY - Berlin AN - OPUS4-15799 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Grothausmann, R. A1 - Zehl, G. A1 - Manke, I. A1 - Fiechter, S. A1 - Bogdanoff, P. A1 - Dorbandt, I. A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Schumacher, G. A1 - Banhart, J. T1 - Nanometer-Tomographie: kleinste Katalysatorteilchen erblicken - Mit Elektronen und Computern die mobile Brennstoffzelle erforschen KW - Electron tomography KW - Polymer electrolyte membrane fuel cell (PEMFC) KW - Reconstruction algorithm KW - DIRECTT PY - 2012 DO - https://doi.org/10.1002/maco.201290007 SN - 0947-5117 SN - 1521-4176 VL - 63 IS - 2 SP - 1 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-26348 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewers, Benjamin A1 - Kupsch, Andreas A1 - Lange, Axel T1 - Das Anwendungspotenzial der zeitaufgelösten Terahertzspektroskopie von der Materialcharakterisierung bis zur Defektlokalisierung T2 - DGZfP-Jahrestagung 2009 CY - Münster, Deutschland DA - 2009-05-18 KW - Computer-Tomographie KW - Rekonstruktionsalgorithmen KW - Ortsauflösung KW - Verschmierung KW - Brennfleck PY - 2009 SN - 978-3-940283-16-0 IS - DGZfP-BB 115 (Di.1.A.4) SP - 1 EP - 12 AN - OPUS4-20494 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Marco A1 - Hentschel, Manfred P. A1 - Illerhaus, Bernhard A1 - Goebbels, Jürgen A1 - Bamberg, J. A1 - Heutling, F. ED - Danny Van Hemelrijck, ED - Igor Solodov, ED - Anastasopoulos, Athanasios ED - Gerhard Busse, T1 - Synchrotron-Refraction-Computed-Tomography for NDT and characterisation of lightweight composite materials T2 - 4th International Conference of Emerging Technologies in Non-Destructive Testing (ETNDT 4) CY - Stuttgart, Germany DA - 2007-04-02 KW - Refraction KW - Computed Tomography KW - NDE KW - Ti-MMC PY - 2008 SN - 978-0-415-46476-5 SP - 217 EP - 221 PB - Taylor & Francis CY - London, UK AN - OPUS4-18680 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. A1 - Illerhaus, Bernhard A1 - Goebbels, Jürgen A1 - Bamberg, J. A1 - Heutling, F. T1 - Micro Crack Characterization of Metal Matrix Composites by 3D-Refraction-Computed-Tomography T2 - 16th World Conference on Nondestructive Testing CY - Montreal, Canada DA - 2004-08-30 KW - NDE KW - X-ray refraction KW - Composites KW - MMC PY - 2004 SP - 9 pages PB - International Committee for Non-Destructive Testing CY - Montreal AN - OPUS4-5486 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Grothausmann, R. A1 - Zehl, G. A1 - Manke, I. A1 - Fiechter, S. A1 - Bogdanoff, P. A1 - Dorbandt, I. A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Schumacher, G. A1 - Banhart, J. T1 - Quantitative structural assessment of heterogeneous catalysts by electron tomography N2 - We present transmission electron microscope (TEM) tomography investigations of ruthenium-based fuel cell catalyst materials as employed in direct methanol fuel cells (DMFC). The digital three-dimensional representation of the samples not only enables detailed studies on number, size, and shape but also on the local orientation of the ruthenium particles to their support and their freely accessible surface area. The shape analysis shows the ruthenium particles deviate significantly from spherical symmetry which increases their surface to volume ratio. The morphological studies help to understand the structure formation mechanisms during the fabrication as well as the high effectiveness of these catalysts in the oxygen reduction reaction at the cathode side of fuel cells. KW - Electron tomography KW - Reconstruction algorithm KW - Catalyst KW - Fuel cell PY - 2011 DO - https://doi.org/10.1021/ja2032508 SN - 0002-7863 SN - 1520-5126 VL - 133 IS - 45 SP - 18161 EP - 18171 PB - American Chemical Society CY - Washington, DC AN - OPUS4-24833 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Lück, S. A1 - Schmidt, V. A1 - Grothausmann, R. A1 - Hilger, A. A1 - Manke, I. T1 - Missing wedge computed tomography by iterative algorithm DIRECTT N2 - A strategy to mitigate typical reconstruction artefacts in missing wedge computed tomography is presented. These artefacts appear as elongations of reconstructed details along the mean direction (i.e. the symmetry centre of the projections). Although absent in standard computed tomography applications, they are most prominent in advanced electron tomography and also in special topics of X-ray and Neutron tomography under restricted geometric boundary conditions. We investigate the Performance of the DIRECTT (Direct Iterative Reconstruction of Computed Tomography Trajectories) algorithm to reduce the directional artefacts in standard procedures. In order to be sensitive to the anisotropic nature of missing wedge artefacts, we investigate isotropic substructures of metal foam as well as circular disc models. Comparison is drawn to filtered backprojection and algebraic techniques. Reference is made to reconstructions of complete data sets. For the purpose of assessing the reconstruction Quality, Fourier transforms are employed to visualize the missing wedge directly. Deficient reconstructions of disc models are evaluated by a length-weighted boundary orientations. The DIRECTT results are assessd at different signal-to-noise ratios by means of local and integral evaluation Parameters. KW - Tomography KW - Algorithm KW - Reconstruction KW - Computed tomography KW - Electron tomography KW - Image morphology KW - Iterative reconstruction KW - Missing wedge PY - 2016 DO - https://doi.org/10.1111/jmi.12313 SN - 1365-2818 VL - 261 IS - 1 SP - 36 EP - 45 PB - Wiley CY - Hoboken, New Jersey, USA AN - OPUS4-35801 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harbich, Karl-Wolfram A1 - Schors, Jörg A1 - Wald, Oliver T1 - New Developments in X-ray-Topography of Advanced Non-Metallic Materials T2 - 15th World Conference on Non-Destructive Testing (WCNDT) CY - Roma, Italy DA - 2000-10-15 PY - 2000 UR - http://www.ndt.net/article/wcndt00/papers/idn258/idn258.htm SN - 1435-4934 VL - 5 IS - 11 PB - NDT.net CY - Kirchwald AN - OPUS4-928 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. T1 - Submikro-Computer-Tomographie an der BAMline T2 - Jahrestagung Zerstörungsfreie Materialprüfung 2004 CY - Salzburg, Österreich DA - 2004-05-17 KW - Computer Tomographie KW - Vergrößerung mit asymmetrischen Kristallen PY - 2004 UR - http://www.ndt.net/article/dgzfp04/papers/v09/v09.htm SN - 3-931381-55-2 SP - 1(?) EP - 7(?) PB - DGZfP CY - Berlin AN - OPUS4-5869 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Grothausmann, R. A1 - Manke, I. A1 - Zehl, G. A1 - Dorbandt, I. A1 - Bogdanoff, P. A1 - Fiechter, S. A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Kupsch, Andreas A1 - Hilger, A. T1 - Charakterisierung von Katalysatormaterialien für Brennstoffzellen mittels Elektronentomografie N2 - Zur Optimierung moderner Katalysatoren für Brennstoffzellen werden diese elektronen-tomografisch charakterisiert. Die Elektronentomografie ermöglicht einzigartige Einblicke in die Nanometer-Strukturen der metallischen Katalysatorpartikel, die auf einem elektrisch leitenden, inerten Kohlenstoffträger abgeschieden werden. Die dreidimensional bildgebende Methode ermöglicht über qualitative Untersuchungen hinaus detaillierte quantitative Form- und Strukturanalysen der Katalysatormaterialien. So werden beispielsweise die Positionen der Katalysatorpartikel relativ zum Trägermaterial analysiert. Ihre Form und Einbettung in den Träger, welche die für die katalytische Reaktion maßgebliche "freie Oberfläche" definieren, werden bestimmt. Die Elektronentomografie ermöglicht somit quantitative Vergleiche zwischen verschiedenen Katalysatormaterialien und Herstellungsverfahren. Sie erweitert die Möglichkeiten der Korrelation gewünschter elektrochemischer Eigenschaften mit der Nanostruktur dieser Materialien und macht so weitere Optimierungen der Katalysatormaterialien möglich. KW - Computed tomography KW - Reconstruction algorithm KW - Electron tomography KW - Catalyst KW - Fuel cell PY - 2010 SN - 0025-5300 VL - 52 IS - 10 SP - 706 EP - 711 PB - Hanser CY - München AN - OPUS4-22072 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Bernd R. A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Harwardt, Michael T1 - Characterization of fibre reinforced metals by X-ray refraction CT PY - 2003 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2002.pdf#page=336 SN - 0179-4159 SP - 336 EP - 337 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-2493 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. A1 - Illerhaus, Bernhard A1 - Goebbels, Jürgen A1 - Bamberg, J. A1 - Heutling, F. T1 - X-Ray Refraction Topography and Computed Tomography for NDE of Lightweight Materials T2 - 9th European Conference on NDT CY - Berlin, Germany DA - 2006-09-25 KW - Synchrotron Refraction CT KW - MMC KW - Bragg-Magnification PY - 2006 SN - 3-931381-86-2 SP - 1(?) EP - 9(?) PB - European Federation for Non-Destructive Testing CY - Berlin AN - OPUS4-13703 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Bernd R. A1 - Hentschel, Manfred P. A1 - Harbich, Karl-Wolfram A1 - Lange, Axel A1 - Schors, Jörg T1 - X-Ray Refraction Topography for Non-Destructive Evaluation of Advanced Materials KW - X-Ray Refraction KW - Fibre Debonding KW - Topography KW - Crack Density KW - Pore Size KW - SAXS PY - 2001 SP - 1 EP - 7 PB - Society of Manufacturing Engineers CY - Dearborn, Mich. AN - OPUS4-1097 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. A1 - Illerhaus, Bernhard A1 - Goebbels, Jürgen T1 - Synchrotron Refraction CT and Synchrotron Bragg Magnification CT for NDE N2 - X-ray refraction topography techniques are based on ultra-small angle scattering by micro-structural elements causing phase-related effects such as refraction and total reflection at a few minutes of arc as the refractive index of X-rays is nearly unity. The refraction contrast is several times higher than “true absorption” and results in images of cracks, pores and fibre debonding separations below the spatial resolution of the detector. In most cases the investigated inner surface and interface structures correlate to mechanical properties. For the exploration of micro structured materials the refraction technique has been improved by a 3D Synchrotron Refraction Computed Tomography test station. The specimen is placed in an X-ray beam between two single crystals, which suppresses all sample scattering. In addition, an asymmetric cut second crystal can magnify the image up to 50 times revealing nano meter resolution. The technique is an alternative to other attempts on raising the spatial resolution of CT machines. KW - X-ray refraction KW - Diffraction Enhanced Imaging (DEI) KW - Bragg magnification KW - Synchrotron radiation KW - Computed Tomography (CT) KW - Metal Matrix Composites (MMC) KW - Lightweight materials KW - Aerospace PY - 2008 DO - https://doi.org/10.1784/insi.2008.50.6.316 SN - 0007-1137 VL - 50 IS - 6 SP - 316 EP - 319 PB - British Institute of Non-Destructive Testing CY - Northampton AN - OPUS4-18001 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Tilgner, R. A1 - Alpern, P. A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Marco A1 - Hentschel, Manfred P. T1 - Package induced deformation of integrated circuits KW - Synchrotron Laue Contrast Radiography SLCR KW - Synchrotron Radiation KW - Electronic Power Device IC PY - 2007 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/infos/bessy/highlights2006.pdf#page=26 SN - 1611-6127 SP - 24 EP - 25 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-15797 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. A1 - Illerhaus, Bernhard A1 - Goebbels, Jürgen T1 - First refraction enhanced 3D computed tomography T2 - International Symposium on Computed Tomography and Image Processing for Industrial Radiology CY - Berlin, Germany DA - 2003-06-23 PY - 2003 SN - 3-931381-48-X N1 - Serientitel: DGZfP-Proceedings BB – Series title: DGZfP-Proceedings BB IS - 84-CD PB - DGZfP CY - Berlin AN - OPUS4-2519 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Müller, Bernd R. T1 - X-ray dark field imaging N2 - A new kind of enhanced contrast X-ray imaging of weakly absorbing materials in dark field mode is presented. Samples such as plastics and biological tissue are a perpetual challenge for radiographic imaging. Recent innovative approaches such as Diffraction Enhanced Imaging (DEI), “phase contrast”, grating interferometry (Talbot-Lau), or Refraction Enhanced Imaging (REI) have in common that they yield enhanced contrast based on deflected X-rays. Here, we introduce a REI modification, which works with a slightly bent single crystal reflecting in Bragg geometry. The samples are placed upstream of the thin crystal within a parallel synchrotron beam. The crystal’s curvature creates a dark-field stripe in the transmission image, similar to the inverse of a Darwin-Prins rocking curve of plane crystals. The reflection condition is met better or worse as a steady function of incidence position. Refracted beam portions of sample interfaces appear bright on black stripes. The entire image is finally synthesized by multiple dark-field stripes. The technique is an alternative to the mentioned techniques. We demonstrate the technique’s advantage by examples of biological and technical microstructures. T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 06.10.2014 KW - X-ray refraction KW - Refraction enhanced imaging (REI) KW - Phase contrast KW - Radiology KW - Soft matter radiography PY - 2014 SN - 978-80-214-5018-9 SP - 1 EP - 7 AN - OPUS4-31971 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. T1 - Synchrotron-based micro-CT and refraction-enhanced micro-CT for non-destructive materials characterisation N2 - X-ray computed tomography is an important tool for non-destructively evaluating the 3-D microstructure of modern materials. To resolve material structures in the micrometer range and below, high brilliance synchrotron radiation has to be used. The Federal Institute for Materials Research and Testing (BAM) has built up an imaging setup for micro-tomography and -radiography (BAMline) at the Berliner storage ring for synchrotron radiation (BESSY). In computed tomography, the contrast at interfaces within heterogeneous materials can be strongly amplified by effects related to X-ray refraction. Such effects are especially useful for materials of low absorption or mixed phases showing similar X-ray absorption properties that produce low contrast. The technique is based on ultra-small-angle scattering by microstructural elements causing phase-related effects, such as refraction and total reflection. The extraordinary contrast of inner surfaces is far beyond absorption effects. Crack orientation and fibre/matrix debonding in plastics, polymers, ceramics and metal-matrix-composites after cyclic loading and hydro-thermal aging can be visualized. In most cases, the investigated inner surface and interface structures correlate to mechanical properties. The technique is an alternative to other attempts on raising the spatial resolution of CT machines. KW - Refraction KW - Computed tomography KW - NDE KW - Ti-MMC KW - Lightweight materials KW - Metal matrix composites KW - Synchrotron radiation KW - X-ray refraction PY - 2009 DO - https://doi.org/10.1002/adem.200800346 SN - 1438-1656 VL - 11 IS - 6 SP - 435 EP - 440 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-20564 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lange, Axel A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Manke, I. A1 - Kardjilov, N. A1 - Arlt, Tobias A1 - Grothausmann, R. T1 - Reconstruction of limited computed tomography data of fuel cell components using direct iterative reconstruction of computed tomography trajectories N2 - CT (computed tomography) reconstructions of fuel cell components of a yet unrivaled spatial resolution and quality are presented. This is achieved by application of the novel DIRECTT (Direct Iterative Reconstruction of Computed Tomography Trajectories) algorithm. We focus on two different key issues which essentially rule the fuel cell's durability on different length scales and physical interactions. On the resolution scale of some 100 µm agglomerations of condensed water in flow-field channels are detected by means of quasi-in situ neutron CT (after operation). Five orders of magnitude below nanometer sized Ru catalyst particles on carbon black support are visualized by electron tomography. Both types of experiments are especially adapted to the type of material involved but they are accompanied by severe deviations from ideal CT measuring conditions, as well. In order to overcome the tremendous reconstruction artifacts of standard algorithms, we employ DIRECTT which is described in detail. Comparisons of DIRECTT reconstructions to the conventional filtered back projection, prove the significant improvements in both experimental methods. KW - PEM fuel cell KW - Neutron computed tomography KW - Electron tomography KW - Reconstruction algrorithm KW - Water management KW - Catalyst PY - 2011 DO - https://doi.org/10.1016/j.jpowsour.2010.10.106 SN - 0378-7753 VL - 196 IS - 12 SP - 5293 EP - 5298 PB - Elsevier CY - Amsterdam [u.a.] AN - OPUS4-23589 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. T1 - Characterization of metal matrix composites by synchrotron refraction computed topography KW - Metal matrix composites KW - Refraction KW - Synchrotron radiation KW - Computed tomography KW - Analyzer based imaging KW - Diffraction enhanced imaging PY - 2010 DO - https://doi.org/10.4028/www.scientific.net/MSF.638-642.967 SN - 0255-5476 VL - 638-642 SP - 967 EP - 972 PB - Trans Tech Publications CY - Aedermannsdorf, Switzerland AN - OPUS4-20563 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel T1 - Reduzierung von Missing-Wedge-Artefakten mit DIRECCT T2 - DGZfP-Jahrestagung 2014 CY - Potsdam, Germany DA - 2014-05-26 PY - 2014 AN - OPUS4-30842 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas T1 - Enhanced spatial resolution using iterative focal desmearing in computed tomography N2 - Computed tomography reconstructions of projected data usually assume an ideal point-like focal spot. However, in practice, the actual finite focus size leads to blurred projections, unavoidably. The elements (voxels) of the reconstruction array are smeared differently as a function of their individual position relative to source and detector. Neglecting the focal smearing generates considerably blurred reconstructions. Previous attempts were based on directly deconvolving blurred projections from a constant kernel, which yields better results but still exhibits artefacts. Iterative algorithms can be adopted to take into account focal smearing as a function of position. However, this requires detailed prior knowledge of quantitative smear functions. The DIRECTT (Direct Iterative Reconstruction of Computed Tomography Trajectories) algorithm is a promising candidate to meet these requirements. It has been demonstrated elsewhere that DIRECTT copes with limited data sets such as limited view and region-of- interest data by tracing single sinusoidal-like trajectories in Radon space, which are selected from the set of all possible trajectories by appropriate criteria. Currently, position-dependent smearing is used in the projection part of iterations. At the example of model reconstructions we demonstrate the gain of spatial resolution by iterative variable desmearing according to the DIRECTT algorithm in comparison to the standard filtered back-projection. T2 - 10th European conference on non-destructive testing CY - Moscow, Russia DA - 2010-06-07 KW - Computed tomography KW - Spatial reslution KW - Reconstruction algorithm KW - Focal smearing PY - 2010 UR - http://www.ndt.net/article/ecndt2010/reports/1_09_18.pdf IS - Paper 4.02.18 SP - 1 EP - 9(?) AN - OPUS4-21466 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel T1 - Numerical correction of X-ray detector backlighting T2 - HZB User Meeting 2011 CY - Berlin, Germany DA - 2011-11-30 PY - 2011 AN - OPUS4-24566 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schors, Jörg A1 - Harwardt, Michael A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Wald, Oliver T1 - Röntgentopografische Verfahren mit Klein- und Weitwinkelstreuung - Ein Überblick KW - Röntgenstreuung KW - Materialcharakterisierung KW - Komposite KW - Keramik KW - Mikrorisse KW - Computertomographie PY - 2008 SN - 0025-5300 VL - 50 IS - 10 SP - 595 EP - 601 PB - Hanser CY - München AN - OPUS4-18247 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel A1 - Müller, Bernd R. A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas T1 - Korrektur des Hinterleuchtens an CT-Synchrotrondaten N2 - In den unterschiedlichsten Methoden der Computertomographie tritt häufig ein diffuses Untergrundsignal in den Einzelprojektionen auf: im Falle der Parallelstrahl-CT mit Synchrotronstrahlung handelt es sich um ein Hinterleuchten durch den Fluoreszenzschirm, der vor der CCD-Kamera angeordnet ist. Dieses Hinterleuchten unterscheidet sich von dem bekannten Nachleuchten (Phosphoreszenz) durch zeitliche Konstanz. Hier äußert sich das Hinterleuchten als Modulation der projizierten Masse und somit als Funktion der Phase (Projektionswinkel) und des Aspektverhältnisses des Objektes. Der Einfluss des Hinterleuchtens ist abhängig von der Größe des von der Probe abgeschatteten Detektorbereiches und des Objektumfangs (Dynamik). Dies hat u.a. zur Folge, dass Abweichungen vom Absorptionsgesetz auftreten, die umso stärker ausgeprägt sind, je weniger Detektorfläche das Objekt abdeckt und je stärker das Objekt schwächt. Dabei können Aufhärtungseffekte wegen der monochromatischen Strahlung ausgeschlossen werden. Mit Referenzmessungen und einem isotropen, homogenen Ansatz, der diese Abweichung als Hinterleuchten beschreibt, lassen sich die auftretenden Fehler deutlich verringern. T2 - DGZfP-Jahrestagung 2011 CY - Bremen, Germany DA - 30.05.2011 KW - Hinterleuchten KW - Detektor KW - Fluoreszenzschirm KW - Synchrotron-Radiographie KW - Computer-Tomographie PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-250038 SN - 978-3-940283-33-7 IS - DGZfP-BB 127 (P6) SP - 1 EP - 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-25003 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Issever, A.S. A1 - Diederichs, G. A1 - Majumdar, S. A1 - Rogalla, P. A1 - Hamm, B.K. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. T1 - Analyser-based tomography images of cartilage N2 - Analyser-based imaging expands the performance of X-ray imaging by utilizing not only the absorption properties of X-rays but also the refraction and scatter rejection (extinction) properties. In this study, analyser-based computed tomography has been implemented on imaging an articular cartilage sample, depicting substructural variations, without overlay, at a pixel resolution of 3.6 µm. KW - Cartilage KW - Analyser-based imaging KW - Computed tomography PY - 2008 DO - https://doi.org/10.1107/S0909049508014829 SN - 0909-0495 SN - 1600-5775 VL - 15 IS - Part 5 SP - 525 EP - 527 PB - Blackwell Publishing CY - Oxford AN - OPUS4-17852 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. T1 - Synchrotron-Refraktions-Computer-Tomographie - EIne neue Methode zur Erkennung von Grenzflächen T2 - DGZfP-Jahrestagung 2009 CY - Münster, Deutschland DA - 2009-05-18 KW - Synchrotronstrahlung KW - Refraktion KW - Diffraktion KW - Kleinwinkelstreuung KW - Materialcharakterisierung KW - Zerstörungsfrei PY - 2009 SN - 978-3-940283-16-0 IS - DGZfP-BB 115 (Di.1.A.1) SP - 1 EP - 11 AN - OPUS4-20609 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas A1 - Hilger, A. A1 - Manke, I. A1 - Lück, S. A1 - Schmidt, V. A1 - Grothausmann, R. T1 - Reduzierung von Missing-Wedge-Artefakten der CT mit DIRECTT N2 - Typische 'Missing Wedge'(MW)-Artefakte in Rekonstruktionen der Computertomografie können mit dem iterativen DIRECTT-Algorithmus (Direkte iterative Rekonstruktion computertomografischer Trajektorien) unterdrückt werden. Die durch fehlende Projektionswinkel bedingten MW-Restriktionen betreffen bisher nur Sonderapplikationen der Röntgen- und Neutronentomografie, müssen in der Nanometer auflösenden Elektronentomografie jedoch als Standard akzeptiert werden. Die MW-Artefakte werden besonders effektiv mit einer spezifischen DIRECTT-Prozedur partiell diskreter Zwischenlösungen beseitigt. Für die Beurteilung der Abbildungsqualität werden Rekonstruktionen von vollständigen und unvollständigen Mess- und Modell-Datensätzen erzeugt und mit Ergebnissen anderer Algorithmen (gefilterte Rückprojektion (FBP) und ART-Methoden) verglichen. Die Fourier-Transformierten der Rekonstruktionen demonstrieren die erfolgreiche Ergänzung der fehlenden Information im MW-Bereich. Die quantitative Bewertung der lokalen Rekonstruktionsqualität mit Methoden der räumlichen Statistik ergibt auch für unterschiedliche Signal-Rausch-Verhältnisse signifikante Vorteile gegenüber FBP und ART. KW - Computertomographie (CT) KW - Rekonstruktionsalgorithmus KW - DIRECTT KW - Missing wedge KW - Statistische Bewertung KW - Elektronentomographie KW - Iterative Rekonstruktion PY - 2014 UR - http://www.hanser-elibrary.com/doi/pdf/10.3139/120.110612 SN - 0025-5300 VL - 56 IS - 9 SP - 716 EP - 721 PB - Hanser CY - München AN - OPUS4-31377 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. A1 - Illerhaus, Bernhard A1 - Goebbels, Jürgen A1 - Bamberg, J. A1 - Heutling, F. T1 - Refraction computed tomography - Application to metal matrix composites N2 - Erstmals wurden MMCs mit Hilfe der Interface-Kontrast verstärkenden Röntgen-Refraktions-Technik in Kombination mit der 3D-CT-Technik untersucht. Die Methode der Röntgen-Refraktions-Topography sowie der Röntgen-Refraktions-Tomography wurden in den letzten Jahren speziell für die zerstörungsfreie Charakterisierung von Leichtbau-Hochleistungs-Werkstoffen wie Verbund-Werkstoffen und Keramiken entwickelt. Die Technik basiert auf der Refraktion von Röntgenlicht an Grenzflächen zwischen Bereichen unterschiedlicher Elektronendichte wie z.B. Faser- und Matrix-Werkstoff. Auf Grund der kurzen Röntgen-Wellenlänge hat der Brechungsindex einen Wert dicht bei eins, sodass der Streuwinkel nur wenige Bogenminuten beträgt. Der Vorteil der kurzen Wellenlänge besteht jedoch darin, dass Poren und Risse detektiert werden können, deren Größe im Nanometerbereich liegen. Damit kann die Refraktions-Technik zum besseren Verständnis von Mikro- und Submikro-Strukturen in der Materialwissenschaft eingesetzt werden. Mit der hier vorgestellten Refraktions-CT wurden Ermüdungsmechanismen an MMCs, bestehend aus SiC-Faser verstärktem Titan (Ti6242) untersucht. Die Messungen wurden am Röntgen-Messplatz der BAM (BAMline) am Synchrotron-Speicherring-BESSY in Berlin Adlershof durchgeführt. KW - X-ray refraction KW - Computed tomography PY - 2004 DO - https://doi.org/10.3139/120.100592 SN - 0025-5300 VL - 46 IS - 6 SP - 314 EP - 319 PB - Carl Hanser Verlag CY - München AN - OPUS4-5870 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Manke, I. A1 - Kardjilov, N. A1 - Schäfer, R. A1 - Hilger, A. A1 - Strobl, M. A1 - Dawson, M. A1 - Grünzweig, C. A1 - Behr, G. A1 - Hentschel, Manfred P. A1 - David, C. A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Banhart, J. T1 - Three-dimensional imaging of magnetic domains N2 - Magnetic domains have been the subject of much scientific investigation since their theoretical existence was first postulated by P.-E. Weiss over a century ago. Up to now, the three-dimensional (3D) domain structure of bulk magnets has never been observed owing to the lack of appropriate experimental methods. Domain analysis in bulk matter thus remains one of the most challenging tasks in research on magnetic materials. All current domain observation methods are limited to studying surface domains or thin magnetic films. As the properties of magnetic materials are strongly affected by their domain structure, the development of a technique capable of investigating the shape, size and distribution of individual domains in three dimensions is of great importance. Here, we show that the novel technique of Talbot-Lau neutron tomography with inverted geometry enables direct imaging of the 3D network of magnetic domains within the bulk of FeSi crystals. KW - Computed tomography KW - Reconstruction algorithm KW - Talbot-Lau neutron tomography KW - Magnetic domains PY - 2010 DO - https://doi.org/10.1038/ncomms1125 SN - 2041-1723 SP - 1 EP - 6 PB - Nature Publishing Group CY - London, UK AN - OPUS4-22609 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas A1 - Manke, I. A1 - Kardjilov, N. A1 - Arlt, Tobias A1 - Grothausmann, R. T1 - Rekonstruktion limitierter CT-Datensätze von Brennstoffzellen mit DIRECTT T2 - DGZfP-Jahrestagung 2010 CY - Erfurt, Deutschland DA - 2010-05-10 KW - Computer-Tomographie KW - Rekonstruktionsalgorithmen KW - Neutronen-Tomographie KW - Elektronen-Tomographie PY - 2010 SN - 978-3-940283-26-9 IS - DGZfP-BB 122 (Mi.1.B.3) SP - 1 EP - 11 CY - Berlin AN - OPUS4-21864 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. T1 - Enhanced Spatial Resolution in 2D CT-Reconstruction without Filtered Back Projection: DIRECTT T2 - 17th World Conference on Non-Destructive Testing CY - Shanghai, China DA - 2008-10-25 KW - Computed tomography KW - Reconstruction algorithm KW - Spatial resolution PY - 2008 SP - 1 EP - 6 PB - International Committee for Non-Destructive Testing CY - Shanghai AN - OPUS4-18569 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Manke, I. A1 - Hartnig, C. A1 - Kardjilov, N. A1 - Hilger, A. A1 - Lange, Axel A1 - Kupsch, Andreas A1 - Banhart, J. T1 - Wasserverteilung in PEM-Brennstoffzellen - In-situ-Untersuchung mit Neutronenradiografie und -tomografie N2 - In-situ-Neutronenradiografie wird erfolgreich eingesetzt, um flüssiges Wasser in Niedertemperatur-PEM-Brennstoffzellen während des Betriebs zerstörungsfrei abzubilden und das sogenannte Wassermanagement – eine der größten Herausforderungen der Entwicklung – durch Anpassung der Materialeigenschaften zu optimieren. Dabei werden die besonderen Eigenschaften der Neutronen genutzt, die metallische Bauteile relativ leicht durchdringen, während selbst kleine Wassermengen durch ihre starke Streuung leicht nachweisbar sind. Die relativ langen Messzeiten für die Neutronentomografie werden durch den Betrieb der Zelle im “angehaltenen” Zustand realisierbar, sodass die dreidimensionale Wasserverteilung darstellbar wird. KW - Neutronen-Radiographie KW - Neutronen-Tomographie KW - Tomographische Rekonstruktionsalgorithmen KW - Brennstoffzellen KW - In-Situ-Radiologie PY - 2009 SN - 0025-5300 VL - 51 IS - 4 SP - 219 EP - 226 PB - Hanser CY - München AN - OPUS4-19221 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -