TY - CONF A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Lück, S. A1 - Schmidt, V. A1 - Hilger, A. A1 - Garcia-Moreno, F. A1 - Manke, I. T1 - Reconstruction of limited view tomography data by DIRECTT N2 - Incomplete tomographic data sets such as limited view (missing wedge) data represent a well-known challenge for reconstruction algorithms, since they unavoidably lead to substantial image artefacts. Such data sets may occur in industrial computed tomography of limited access (e.g. extended components, fixed objects), directional opacity, limited sample life time or laminographic set-up. We present strategies to effectively suppress the typical elongation artefacts (e.g. lemon-like deformed pores) by our iterative algorithm DIRECTT which offers the opportunity to vary the versatile reconstruction parameters within each cycle. Those strategies are applied to experimental data obtained from metallic foams as well as model simulations. Comparison is drawn to state-ofthe-art techniques (filtered backprojection and algebraic techniques). Further reference is made to reconstructions of complete data sets serving as gold standards. For quantitative assessment of the reconstruction quality adapted techniques based on spatial statistics are introduced. T2 - 18th WCNDT - World conference on nondestructive testing CY - Durban, South Africa DA - 16.04.2012 KW - Computed tomography KW - Limited tomographic data KW - Iterative reconstruction KW - DIRECTT KW - Limited view KW - Missing wedge KW - Spatial statistics PY - 2012 UR - http://www.ndt.net/article/wcndt2012/papers/208_wcndtfinal00208.pdf SN - 978-0-620-52872-6 SP - 1 EP - 9 AN - OPUS4-25834 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lueck, S. A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Schmidt, V. T1 - Statistical comparison of various reconstruction algorithms with respect to missing wedge artifacts in computed tomography N2 - The presence of elongation, streak and blurring artifacts in tomograms recorded under a missing wedge of rotation angles presents a major challenge for the quantitative analysis of tomographic image data. We show that the missing wedge artifacts of standard reconstruction algorithms may be reduced by the innovative reconstruction technique DIRECTT. For the comparison of missing wedge artifacts we apply techniques from spatial statistics, which have been specifically designed to investigate the shape of phase boundaries in tomograms. KW - X-ray tomography KW - Scanning transmission electron microscopy (STEM) KW - Structural PY - 2012 DO - https://doi.org/10.1557/opl.2012.209 SN - 0272-9172 VL - 1421 SP - 1 EP - 6 PB - North-Holland Publ. Co. CY - New York, NY AN - OPUS4-25468 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas A1 - Müller, Bernd R. T1 - Numerical correction of X-ray detector backlighting N2 - A novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background signals ('backlighting') of 2D X-ray detectors is suggested. Depending on the detector geometry the mechanism may be different, either based on the optical scattering by the fluorescent screen materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert–Beer's law in single projections (radiographs). When used as input data for computed tomography these violations are directly observed via modulation of the projected mass as a function of the rotation phase and the sample’s aspect ratio (dynamics). The magnitude of the diffuse background signal depends on the detector area covered by the projected sample. They are more pronounced the smaller the shadowed area and the stronger the total attenuation. This implies that the reconstruction suffers from additional anisotropic artifacts caused by elongated sample structures. This issue is studied simply by absorption of flat plates in a conventional laboratory radiography set-up and at a synchrotron radiation facility. In the latter case beam hardening artifacts can be excluded due to the monochromatic radiation. The proposed correction procedure requires simple integral intensity offsets as a constant (non-local) light scattering mechanism is assumed. KW - Detector backlighting KW - X-ray detector scattering KW - Fluorescent screen KW - Diffuse background KW - Computed tomography PY - 2012 DO - https://doi.org/10.3139/146.110659 SN - 1862-5282 VL - 103 IS - 2 SP - 174 EP - 178 PB - Carl Hanser CY - München AN - OPUS4-25553 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Grothausmann, R. A1 - Zehl, G. A1 - Manke, I. A1 - Fiechter, S. A1 - Bogdanoff, P. A1 - Dorbandt, I. A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Schumacher, G. A1 - Banhart, J. T1 - Dreidimensionale Charakterisierung von Katalysatornanopartikeln N2 - We present transmission electron microscope (TEM) tomography investigations of ruthenium-based fuel cell catalyst materials as employed in direct methanol fuel cells (DMFC). The digital three-dimensional representation of the samples not only enables detailed studies on number, size, and shape but also on the local orientation of the ruthenium particles to their support and their freely accessible surface area. The shape analysis shows the ruthenium particles deviate significantly from spherical symmetry which increases their surface to volume ratio. The morphological studies help to understand the structure formation mechanisms during the fabrication as well as the high effectiveness of these catalysts in the oxygen reduction reaction at the cathode side of fuel cells. KW - Radiography KW - Tomography KW - Neutrons KW - Polymer electrolyte membrane fuel cell (PEMFC) KW - Fuel cell stack PY - 2012 SN - 1862-5282 VL - 103 IS - 1 SP - 135 EP - 136 PB - Carl Hanser CY - München AN - OPUS4-25976 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Markötter, Henning A1 - Manke, I. A1 - Kuhn, R. A1 - Arlt, Tobias A1 - Kardjilov, N. A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hartnig, C. A1 - Scholta, J. A1 - Banhart, J. T1 - Neutron tomographic investigations of water distributions in polymer electrolyte membrane fuel cell stacks N2 - Neutron tomography was applied to study the 3D water distribution in full polymer electrolyte membrane fuel cell (PEMFC) stacks. The water distribution after switch-off of the fuel cell was analyzed over a period of 36 h. We found a slowly increasing water amount in the fuel cell, but only few changes within a time period of 5 h, which is about the time necessary for neutron tomography. In this way, the requirement for successful tomography was obtained. It is demonstrated how the quasi in-situ tomography technique enables us to study the water content in individual flow field channels of three-fold stacks. Flow field as well as stack design issues are addressed by this visualization method showing weak points due to a non-uniform water distribution that can be identified by means of neutron imaging. KW - Radiography KW - Tomography KW - Neutron imaging KW - Polymer electrolyte membrane fuel cell (PEMFC) KW - Manifold stack KW - Water management PY - 2012 DO - https://doi.org/10.1016/j.jpowsour.2012.07.043 SN - 0378-7753 VL - 219 SP - 120 EP - 125 PB - Elsevier CY - Amsterdam [u.a.] AN - OPUS4-26317 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -