TY - CONF A1 - Lüth, Peter T1 - Evaluation of the Round Robin Solid Oxidizer Test (UN O.1) 2004 / 05 T2 - OECD IGUS Meeting CY - Buxton, England, UK DA - 2005-07-15 PY - 2005 SP - 6 pages CY - Buxton AN - OPUS4-7674 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter T1 - Statistical analysis of the Round Robin Solid Oxidiser Test (UN Test O.1) 2004/05 and the sample pretreatment of the Liquid Oxidiser Test (UN Test O.2) - Results from BAM 2004/05 - T2 - Meeting of the OECD-EOS solid oxidiser working group CY - Frankfurt am Main, Germany DA - 2005-04-14 PY - 2005 AN - OPUS4-7663 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter T1 - Evaluation of the Round Robin Solid Oxidiser Test (UN O.1) 2004/05 T2 - OECD-IGUS energetic and oxidising substances working group, OECD IGUS Meeting CY - Buxton, England DA - 2005-06-15 PY - 2005 AN - OPUS4-7664 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Kunath, K. A1 - Lüth, Peter A1 - Schmidt, Martin A1 - Simon, K. A1 - Uhlig, S. T1 - Evaluation of the interlaboratory test 2010-2011 on the method DIN EN15188:2007 'Determination of the spontaneous ignition behaviour of dust accumulations' N2 - For the classification and safe handling and use of the chemicals, special standardized testing proce-dures have been developed and are used world-wide. Safety experts must be able to fully rely on the precise execution of the respective laboratory tests and assessments. In this context interlaboratory tests (round robin tests, interlaboratory comparisons / intercomparisons) are a crucial element of a laboratory's quality system. Participation in interlaboratory tests is explicitly recommended by the standard ISO/IEC 17025. The present document reports on the results of the interlaboratory test 2010/2011 on the test method DIN EN 15188:2007 “Determination of the spontaneous ignition behaviour of dust accumulations” [1] which was organized by the Center for Quality Assurance for Testing of Dangerous Goods and Haz-ardous Substances. The test method DIN EN 15188:2007 is applied to characterize the self-ignition behaviour of combus-tible dusts. The experimental basis for describing the self-ignition behaviour of a given dust is the de-termination of the self-ignition temperatures (TSI) of differently-sized volumes of the dust sample by isoperibolic hot storage experiments (storage at constant oven temperatures) in commercially availa-ble ovens. The results thus measured reflect the dependence of self-ignition temperatures upon dust volume [1]. Several internal investigations and interlaboratory comparisons in the past have shown significant differences between the lab-specific results of hot storage tests. Figure 2-1 shows the Pseudo-Arrhenius plot of hot storage tests of eight different laboratories (Round Robin Test 2002, BAM). The dust under this investigation was Lycopodium powder (spores). The par-ticipants of this interlaboratory test used different laboratory ovens (size, ventilation) as well as differ-ent sample baskets (shape, mesh size, single- and double-walled). Figure 2-1 shows clearly that this test failed to produce reasonable reproducibility of the TSI between the different laboratories. As possible reasons for the deviations have been identified lab-specific dif-ferences, e.g.: - oven ventilation (enforced, natural convection), - oven size, - sample baskets, - radiation effects, - measuring precision (temperature difference between tests with ignition and no ignition), - minimum sample size. To reduce the differences between the labs it was necessary to ameliorate the testing method and to improve the execution of the method by the lab. From there, the installation of an inner chamber into the laboratory oven was suggested as experimental set-up in EN 15188:2007 to provide more repro-ducible test conditions. The aappropriateness of this set-up has not been verified yet. The current interlaboratory test 2010-2011 focuses on the use of a special mesh wire screen and spe-cial volumes of the sample baskets (cubes) to normalise/harmonise the test conditions in the different labs. In preparation for the interlaboratory test a joint program between Syngenta and BAM has been initiated in 2009. As a result of these investigations a modified set-up ( chapter 3) has been identi-fied to be probably more appropriate than the suggested set-up in DIN EN-15188:2007. Due to the time-consuming test procedure and to optimize the workflow for the laboratories this in-terlaboratory test should be performed stepwise as a multi-level test ( chapter 5.4) on one typical test sample. KW - Interlaboratory test KW - Self-ignition KW - Spontaneous ignition PY - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-282978 SN - 978-3-9815748-4-5 IS - Final Report SP - 1 EP - 113 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-28297 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Antoni, S. A1 - Kunath, K. A1 - Lüth, Peter A1 - Simon, K. A1 - Uhlig, S. T1 - Evaluation of the interlaboratory test on the method UN O.2 / EC A.21 'Test for oxidizing liquids' 2009 - 2010 N2 - For the classification of chemicals, special standardized test procedures have been developed and are used world-wide. Safe handling and use of these chemicals depend on the correct classification which therefore must be based on the precise and correct execution of the tests and their evaluation. In this context interlaboratory tests (round robin tests, interlaboratory comparisons / intercomparisons) are a crucial element of a laboratory's quality system. Participation in interlaboratory tests is explicitly recommended by the standard ISO/IEC 17025. The present document reports on the results of the interlaboratory test 2009/2010 on the test methods UN O.2 “Test for oxidizing liquids” [1] / EC A.21 “Oxidizing Properties (Liquids)” [2] which was organized by the Center for Quality Assurance for Testing of Dangerous Goods and Hazardous Substances. The test methods UN O.2 and EC A.21 are applied to characterize the oxidizing properties of liquid chemical substances or mixtures. To differentiate between chemicals with hazardous / dangerous oxidizing properties and chemicals which are not classified as hazardous / dangerous, the substance’s oxidizing properties are compared to those of a standard reference substance. Since the methods (UN O.2 / EC A.21) were developed and came into force in the early nineties a systematic review concerning the practical application of the test method has not been carried out. KW - Oxidiser KW - Oxidierend KW - Gefahrgut KW - Dangerous goods KW - UN O.2 KW - Prüfmethode KW - Test method PY - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-250904 SN - 978-3-9814634-0-8 SP - 1 EP - 95 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin ET - Final report AN - OPUS4-25090 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Antoni, S. A1 - Kunath, K. A1 - Lüth, Peter A1 - Schlage, R. A1 - Simon, K. A1 - Uhlig, S. A1 - Wildner, W. A1 - Zimmermann, C. T1 - Evaluation of the interlaboratory test on the method UN test O.1 'Test for oxidizing solids' with sodium perborate monohydrate 2005 / 06 N2 - The classification of solid oxidizers according to the GHS (Globally Harmonized System of Classifica-tion and Labelling of Chemicals) and according to regulations on the transport of dangerous goods (based on the UN Recommendations/Model Regulations and implemented in all carrier domains as transport by road, railway, sea, air) is performed on the basis of the results of the UN test O.1 (―Test for oxidizing solids‖ described in chapter 34.4.1 in the Recommendations on the Transport of Danger-ous Goods, Manual of Tests and Criteria, Fifth revised edition, United Nations, New York and Geneva, 2009). This test was introduced into the UN Test Manual in 1995 as a replacement for a similar test from 1986. Even though the O.1 test is much better than the previous one there are still many prob-lems with this test. For this reason the IGUS-EOS working group (international group of experts on the explosion risks of unstable substances – working group: energetic and oxidizing substances) installed an ad-hoc working group in 2002 assigned with the task of proposing solutions for the existing prob-lems. The adequacy of such proposals has to be proven preferably by interlaboratory comparison (interlaboratory test) before they are presented to the UN Sub Committee for adoption into the UN Test Manual. The present report is the evaluation of an interlaboratory test which was designed by the Ad-hoc working group in order to find out whether the current method of comparing combustion times of test mixtures with those of reference mixtures is suitable in principle and whether some approaches for improvement of the method can be identified. KW - Oxidiser KW - Oxidierend KW - Gefahrgut KW - Dangerous goods KW - UN O.1 KW - Prüfmethode KW - Test method PY - 2010 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-250919 UR - http://www.bam.de/de/service/publikationen/publikationen_medien/un_test_for_oxidizing_solids_final_report_on_interlab_test.pdf SN - 978-3-9814281-2-4 SP - 1 EP - 65 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin ET - Final report AN - OPUS4-25091 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Kunath, K. A1 - Lüth, Peter A1 - Uhlig, S. T1 - Interlaboratory test on the method UN test N.5 / EC A.12 'Substances which, in contact with water, emit flammable gases' 2007 N2 - For the classification of chemicals, special standardized test procedures have been developed and are used world-wide. Safe handling and use of these chemicals depend on the correct classification which therefore must be based on the precise and correct execution of the tests and their evaluation. In this context interlaboratory tests (round robin tests, interlaboratory comparisons / intercomparisons) are a crucial element of a laboratory's quality system. Participation in interlaboratory tests is explicitly recommended by the standard ISO/IEC 17025. The present document reports on the results of the interlaboratory test 2007 on the method UN Test N.5 “Test method for substances which in contact with water emit flammable gases” [1] / EC A.12 “Flammability (contact with water)” [2] which was organized by the Center for Quality Assurance for Testing of Dangerous Goods and Hazardous Substances. In dependence on the chemical structure and/or the physical form and state (e.g. particle size) substances or mixtures may be able to react with water (even water damp / air humidity) under normal ambient temperature conditions. Sometimes this reaction can be violent and/or with significant generation of heat. Especially if gases are evolved this reaction may become dangerous. In addition, it is important to know whether a substance emits flammable gases due to contact with water because special precautions are necessary especially with regard to explosion protection. The methods UN Test N.5 and EC A.12 are applied to characterize chemical substances or mixtures which in contact with water emit flammable gases. To differentiate between chemicals with these properties and chemicals which are not classified as hazardous / dangerous, the substance’s gas evolution rate is determined and compared to the classification criteria(s) in the last step of the test method. In the methods UN Test N.5 / EC A.12 no special laboratory apparatus / measuring technique to determine gas evolving flow is required. However, practical experience shows that the testing procedure for substances and mixtures which in contact with water emit flammable gases is sensitive to a number of influencing factors. Since the methods (UN N.5 / EC A.12) were developed and came into force in the early nineties a systematic review concerning the practical application of the test method has not been carried out. KW - Flammability KW - Entzündbar KW - Gefahrgut KW - Dangerous goods KW - UN N.5 KW - EC A.12 KW - Prüfmethode KW - Test method PY - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-250944 SN - 978-3-9814634-1-5 SP - 1 EP - 35 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-25094 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter T1 - Vorstellung und Erläuterung des Fallhammer-Ringversuches - Auswertung T2 - Symposium der AG "Sprengstoff" der Kommission Kriminalwissenschaft und - technik/Erkennungsdienst (KKWT/ED) CY - Berlin, Germany DA - 2012-05-08 PY - 2012 AN - OPUS4-27403 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Uhlig, S. T1 - Suitability of the pressure vessel (UN O.2) for the solid oxidiser test (UN O.1) T2 - IGUS ENERGETIC AND OXIDISING SUBSTANCES WORKING GROUP, Meeting of the EOS solid oxidizer working group, BAM CY - Berlin, Germany DA - 2006-09-06 PY - 2006 AN - OPUS4-12666 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Lüth, Peter A1 - Kurth, Lutz T1 - Ringversuch mit dem Fallhammer gemäß Abs. 1.6.2 Mechanische Empfindlichkeit (Schlag) der Methode A.14 Explosionsgefahr 2011 - Kurzbericht N2 - Ringversuche sind ein probates Mittel zur Bewertung der praktischen Anwendung einer Prüfmethode und der Leistungsfähigkeit von Prüflaboratorien. Bei der in diesem Ringversuch untersuchten Methode A.14 Explosionsgefahr handelt es sich um ein Prüfschema, um festzustellen, ob feste oder pastenförmige Stoffe bei Flammenzündung (thermische Empfindlichkeit) oder bei Einwirkung von Schlag oder Reibung (mechanische Empfindlichkeit) und ob Flüssigkeiten bei Flammenzündung oder bei Einwirkung von Schlag eine Explosionsgefahr im Sinne des nationalen und europäischen Chemikalienrechts (z.B. SprengG, REACH-VO, CLP-VO) darstellen. Der hier beschriebene Ringversuch behandelt die Prüfung mit dem Fallhammer gemäß Abs. 1.6.2 Mechanische Empfindlichkeit (Schlag) der Methode A.14 Explosionsgefahr. Angeregt wurde dieser Ringversuch von verschiedenen, nationalen Prüflaboratorien. Ein spezieller Auslöser war z.B. die Frage, ob vergleichbare Ergebnisse zwischen einer in einem Labor selbstgebauten Fallhammer-Apparatur und Geräten von kommerziellen Herstellern erzielt werden können. Es bestand die Frage nach einer entsprechenden Qualitätssicherung. Die praktischen Untersuchungen des hier vorgestellten Ringversuchs wurden im Zeitraum von September 2011 bis Januar 2012 durchgeführt. Die Auswertungsergebnisse und Schlussfolgerungen sind von der BAM auf einem Symposium mit Beteiligung der Ringversuchsteilnehmer vorgestellt und diskutiert worden. Der jetzt vorliegende Bericht berücksichtigt die Ergebnisse der Diskussion auf diesem Symposium. KW - Ringversuch KW - Fallhammer KW - Explosionsgefahr PY - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-288561 SN - 978-3-9815748-6-9 SP - 1 EP - 43 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-28856 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schmidt, Martin A1 - Lüth, Peter A1 - Malow, Marcus A1 - Schoßig, Jörg T1 - Isoperibole Warmlagerung Einfluss der Streuung experimentell ermittelter Selbstentzündungstemperaturen auf die Übertragung in den technischen Maßstab T2 - 10. Fachtagung Anlagen-, Arbeits- und Umweltsicherheit CY - Köthen, Germany DA - 2010-11-04 PY - 2010 AN - OPUS4-22302 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schmidt, Martin A1 - Lüth, Peter T1 - Interlaboratory test 2010/11 "EN 15188:2007 - Self-ignition temperature" T2 - ProcessNet Arbeitsausschuss "Sicherheitstechnische Kenngrößen" CY - Frankfurt am Main, Germany DA - 2010-10-27 PY - 2010 AN - OPUS4-22303 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lüth, Peter A1 - Uhlig, S. A1 - Frost, K. A1 - Malow, Marcus A1 - Michael-Schulz, Heike A1 - Schmidt, Martin A1 - Zakel, Sabine T1 - CEQAT-DGHS interlaboratory tests for chemical safety: Validation of laboratory test methods by determining the measurement uncertainty and probability of incorrect classification including so-called “Shark profiles” N2 - Laboratory test results are of vital importance for correctly classifying and labelling chemicals as “hazardous” as defined in the UN Globally Harmonized System (GHS) / EC CLP Regulation or as “dangerous goods” as defined in the UN Recommendations on the Transport of Dangerous Goods. Interlaboratory tests play a decisive role in assessing the reliability of laboratory test results. Interlaboratory tests performed over the last 10 years have examined different laboratory test methods. After analysing the results of these interlaboratory tests, the following conclusions can be drawn: 1. There is a need for improvement and validation for all laboratory test methods examined. 2. To avoid any discrepancy concerning the classification and labelling of chemicals, the use of validated laboratory test methods should be state of the art, with the results accompanied by the measurement uncertainty and (if applicable) the probability of incorrect classification. This paper addresses the probability of correct/incorrect classification (for example, as dangerous goods) on the basis of the measurement deviation obtained from interlaboratory tests performed by the Centre for quality assurance for testing of dangerous goods and hazardous substances (CEQAT-DGHS) to validate laboratory test methods. This paper outlines typical results (e.g. so-called “Shark profiles” – the probability of incorrect classification as a function of the true value estimated from interlaboratory test data) as well as general conclusions and steps to be taken to guarantee that laboratory test results are fit for purpose and of high quality. T2 - 13th International Symposium on Hazards, Prevention and Mitigation of Industrial Explosions (ISHPMIE 2020) CY - Brunswick, Germany DA - 27.07.2020 KW - Dangerous goods KW - Hazardous substances KW - Interlaboratory test KW - Test method KW - Validation KW - Quality assurance KW - Measurement uncertainty KW - Incorrect classification KW - Shark profiles PY - 2021 U6 - https://doi.org/10.1016/j.jlp.2021.104532 SN - 0950-4230/ VL - 72 SP - 104532 PB - Elsevier Ltd. AN - OPUS4-52751 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Lüth, Peter A1 - Brandes, E. A1 - Stolz, T. T1 - Interlaboratory test 2012-2013 on the method EN 14522:2005 "Determination of the auto ignition temperature of gases and vapours" / IEC 60079-20-1, part 7 "Method of test for auto-ignition temperature" N2 - For the classification, safe handling and use of chemicals, special standardised test methods have been developed and are used worldwide. Safety experts must be able to fully rely on the precise execution of the respective laboratory tests and assessments. In this context interlaboratory tests (round robin tests, interlaboratory comparisons / intercomparisons) are a crucial element of both the further development and improvement of the methods and of a laboratory's quality system. Participation in interlaboratory tests is explicitly recommended by the standard ISO/IEC 17025. This document reports on the results of the interlaboratory test 2012-2013 on the test method EN 14522:2005 “Determination of the auto ignition temperature of gases and vapours“ / IEC 60079-201, part 7 ”Method of test for auto-ignition temperature”. The auto ignition temperature is an important safety characteristic for explosion protection and prevention. It is the basis for classifying substances and explosion protected equipment into temperature classes. Because safety characteristic data are not a pure substance constant but a figure which denotes a special property of the substance, the determination methods are standardised. Currently EN 14522 and IEC 60079-20-1, part 7 are under revision with the aim to combine both to a standard accepted worldwide. An important part of the standard is the laboratory’s verification of their apparatus and procedure. To base this forthcoming standard on reliable and up-to-date verification data an interlaboratory test appears as the method of choice. The verification data given in the recent issues of the standards are based on comparison measurements which date back to a long time ago and did not include automated apparatuses. KW - Ringversuch KW - Auto ignition temperature KW - Zündtemperatur KW - Liquids KW - Flüssigkeiten PY - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-306867 SN - 978-3-9816380-0-4 SP - 1 EP - 89 PB - Bundesanstalt für Materialforschung und -prüfung (BAM), Physikalisch-Technische Bundesanstalt (PTB) CY - Berlin, Braunschweig ET - Final Report AN - OPUS4-30686 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Michael-Schulz, Heike A1 - Lüth, Peter T1 - UN-Test N.5 T2 - Informal working group (UN TDG/GHS-Subcommittees) CY - Paris, France DA - 2009-04-23 PY - 2009 AN - OPUS4-19577 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Wilrich, Cordula A1 - Michael-Schulz, Heike A1 - Brandes, E. A1 - Uhlig, S. T1 - Center for quality assurance for testing of dangerous goods and hazardous substances - Brief information about status and activities T2 - IGUA ENERGETIC AND OXIDISING SUBSTANCES WORKING GROUP CY - Saint Petersburg, Russia DA - 2009-06-10 PY - 2009 AN - OPUS4-19399 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Brandes, E. A1 - Kurth, Lutz A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. A1 - Frost, K. T1 - CEQAT-DGHS Ringversuchsprogramm der BAM in Kooperation mit QuoData und PTB - aktueller Stand, Erfarhungen und Schlussfolgerungen - T2 - Gemeinsame Sitzung der ProcessNet-AA Reaktionstechnik sicherheitechnisch schwieriger Prozesse u. sicherheitechnische Kenngrößen CY - Berlin DA - 2015-03-26 PY - 2015 AN - OPUS4-32904 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Frost, K. A1 - Lüth, Peter A1 - Schmidt, Martin A1 - Simon, K. A1 - Uhlig, St. T1 - Evaluation of the interlaboratory test 2015-2016 on the method DIN EN 15188:2007 “Determination of the spontaneous ignition behaviour of dust accumulations” N2 - For the classification, safe handling and use of the chemicals, special standardized testing procedures have been developed and are used worldwide. Safety experts must be able to fully rely on the precise execution of the respective laboratory tests and assessments. In this context, interlaboratory tests are a crucial element of a laboratory's quality system. Participation in interlaboratory tests is explicitly recommended by the standard ISO/IEC 17025. The present document reports the results of the interlaboratory test 2015-2016, which was performed on the test method DIN EN 15188:2007 “Determination of the spontaneous ignition behaviour of dust accumulations”. It was organized by BAM in the frame of the co-operation project CEQAT-DGHS Centre for Quality Assurance for Testing of Dangerous Goods and Hazardous Substances. The test method DIN EN 15188:2007 is applied to characterize the self-ignition behaviour of combustible dusts. The experimental basis for describing the self-ignition behaviour of a given dust is the determination of the self-ignition temperatures (TSI) of differently-sized volumes of the dust sample by isoperibolic hot storage experiments (storage at constant oven temperatures) in commercially available ovens. The results measured this way reflect the dependence of the self-ignition temperatures on the volume of a dust accumulation. The interlaboratory test 2015-2016 on the method DIN EN 15188:2007 is the latest in a systematic stepwise built up series of method validation interlaboratory tests and internal laboratory investigations. The aim of this interlaboratory test was to determine measurement uncertainties of the modified method DIN EN 15188 for different substances, covering a sufficiently wide range of self-ignition behaviours in the scope of the DIN EN 15188 of the four basket test to extrapolate to storage volumes up to 1000 m³ and the single basket test for a basket volume of 1000 cm³. The precision of the four basket test and the single basket of the modified method DIN EN 15188 can be assessed as acceptable for the four sample materials investigated in the current interlaboratory test 2015-2016. It was possible to derive a functional equation for the measurement uncertainty U depending on the storage volume V. The measurement uncertainty cannot be ignored and must be considered, if TSI results should be used in practice. KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung KW - Messunsicherheit KW - Dangerous goods KW - Hazardous substances KW - Round robin test KW - Interlaboratory comparison KW - Test method KW - Validation KW - Measurement uncertainty PY - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-387343 SN - 978-3-9818270-0-2 SP - 1 EP - 106 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-38734 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Brandes, E. A1 - Frost, K. A1 - Kurth, Lutz A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. T1 - CEQAT-DGHS Ringversuchsprogramm der BAM in Kooperation mit QuoData und PTB N2 - Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und -prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS). Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung abzielen und nicht auf Leistungstests. T2 - 14. Kolloquium zur chemischen und physikalischen Sicherheitstechnik (BAM-PTB-Kolloquium) CY - Berlin, Germany DA - 14.06.2016 KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung PY - 2016 SN - 978-3-9817853-5-7 SN - 0938-5533 SP - 143 EP - 143 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-38464 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Brandes, E. A1 - Frost, K. A1 - Kurth, Lutz A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. T1 - CEQAT-DGHS Ringversuchsprogramm der BAM in Kooperation mit QuoData und PTB N2 - Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und -prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS). Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung abzielen und nicht auf Leistungstests. T2 - 14. Kolloquium zur chemischen und physikalischen Sicherheitstechnik (BAM-PTB-Kolloquium) CY - Berlin, Germany DA - 14.06.2016 KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung PY - 2016 AN - OPUS4-38465 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Schmidt, Martin A1 - Brandes, E. T1 - CEQAT-DGHS Ringversuchsprogramm der BAM in Kooperation mit QuoData und PTB - Erfahrungen und Schlussfolgerungen zur Durchführung von Ringversuchen zur Methodenvalidierung N2 - Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und -prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS). Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung abzielen und nicht auf Leistungstests. T2 - Workshop: Arbeiten mit ProLab und ProLab Plus Planung und statistische Auswertung von Ringversuchen zur Methodenvalidierung CY - Dresden, Germany DA - 15.06.2016 KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung PY - 2016 AN - OPUS4-38468 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Brandes, E. A1 - Frost, K. A1 - Kurth, Lutz A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. T1 - CEQAT-DGHS Ringversuchsprogramm der BAM in Kooperation mit QuoData GmbH und PTB - aktueller Stand, Erfahrungen und Schlussfolgerungen N2 - Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und -prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS). Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung abzielen und nicht auf Leistungstests. T2 - QM Gesprächskreis zum Thema „Die Rolle der Ringversuche im Qualitätsmanagement“ CY - Berlin, Germany DA - 25.01.2016 KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung PY - 2016 AN - OPUS4-38469 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Brandes, E. A1 - Frost, K. A1 - Kurth, Lutz A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. T1 - CEQAT-DGHS Ringversuchsprogramm für die Chemikaliensicherheit -Methodenvalidierung N2 - Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und –prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS). Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung und auf die Bestimmung der Messunsicherheit der jeweiligen Prüfmethode abzielen und nicht auf Leistungstests. T2 - Behörden-Erfahungsaustausch CY - Berlin, Germany DA - 4. Juni 2018 KW - Prüfmethode KW - Methodenvalidierung KW - Gefahrgut KW - Gefahrstoff KW - Qualitätssicherung PY - 2018 AN - OPUS4-45297 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Brandes, E. A1 - Frost, K. A1 - Kurth, Lutz A1 - Malow, Marcus A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. T1 - CEQAT-DGHS Interlaboratory test programme for chemical safety - status and activities N2 - Safety experts, carriers or traders must be able to rely on the validity of the method and on correct results of safety tests and assessments in the laboratory. Bundesanstalt für Materialforschung und –prüfung (BAM), Berlin and Physikalisch-Technischen Bundesanstalt (PTB), Braunschweig have extensive experience in the field of testing and assessment of physical hazards of chemicals. Interlaboratory tests on different test methods have been performed by BAM and PTB during the last 10 years. Significant differences between the results of the participating laboratories were observed in all interlaboratory test. The deviations of the test results were not caused only by laboratory faults but also by deficiencies of the test method; i.e. many of the method descriptions are too ambiguous and allow divergences for interpretation. Therefore, it is necessary to know exactly how good the method is that is used to classify dangerous goods or hazardous substances or to determine safety-relevant parameters. A key criterion is the measurement uncertainty. One can choose simple methods with large error limits, but the measurement uncertainties should be known and always communicated together with the test results. This would allow safety specialists to be able to assess test results correctly and make well-founded decisions, e.g. for adequate protective measures. Interlaboratory tests play a decisive role in assessing the reliability of test results. Participation in interlaboratory tests is not only a crucial element of the quality assurance of laboratories; as such it is explicitly recommended in DIN EN ISO/IEC 17025. In addition, interlaboratory tests are also used to develop and validate test methods and can be used for the determination of the measurement uncertainty. Therefore, the BAM and PTB continue to support the further development of the interlaboratory test programme of CEQAT-DGHS (Centre for quality assurance for testing of dangerous goods and hazardous substances, www.ceqat-dghs.bam.de), established in 2007. This programme is run by BAM in collaboration with the PTB and the QuoData Gesellschaft für Qualitätsmanagement und Statistik mbH, Dresden. A new interlaboratory test for methods validation on the test method UN Test N.5 "Test method for substances which in contact with water emit flammable gases” is currently being prepared and will be carried out in 2018. Laboratories that specialise in this test are invited to participate in the interlaboratory test. Interested laboratories can check the details and register to participate in the interlaboratory test at the CEQAT-DGHS website. T2 - MEETINGS OF IGUS EOS GROUP CY - Shanghai, P. R. China DA - 09.04.2018 KW - Dangerous goods KW - Hazardous substances KW - Test methods validation KW - Quality assurance PY - 2018 AN - OPUS4-44858 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Malow, Marcus T1 - CEQAT-DGHS Interlaboratory tests for chemical safety – A new gravimetric procedure for the gas flow measurement for flammable and toxic gases N2 - Testing of hazardous materials and evaluating their hazardous properties concerning transport, handling or use is essential for the prevention of incidents. For this purpose, test methods have been developed and published that are used worldwide today (European Union, 2008, United Nations, 2019). For the evaluation of test results their correct measurement is of importance. On basis of the interlaboratory tests carried out by BAM and PTB within the framework of the CEQAT-DGHS in the last years, it is shown that there is a need for improvement in all the test methods examined so far. In addition to the interlaboratory tests further quality measures are mandatory (ISO, 2017). For example, methods for verifying the test equipment used in the laboratories should be developed. The development of a verification method is demonstrated using the test method UN Test N.5 as an example. This test method is used to evaluate substances which in contact with water emit flammable gases. The basic principle of the verification method is demonstrated by Lüth et al. (2019). Requirements and difficulties during this development are discussed. This test procedure UN Test N.5 has now been modified at BAM so that it is possible to measure very small or large amounts of both flammable and/or toxic gases over a long period of time in a validated and verified test apparatus, utilizing the principle of a gas collector. This allows us to determine slow as well as fast gas evolution rates. The determination of the evolution rates (e.g. total gas amount or flow rate) of toxic gases is of special interest because of the ongoing discussion how to evaluate and quantify toxic gases which are formed from a substance due to contact with water. Up today no validated test procedure for the measurement of evolution rates for toxic gases is described. It is shown that the newly modified test method could help to solve this problem. T2 - 13th International Symposium on Hazards, Prevention, and Mitigation of Industrial Explosions CY - Online meeting DA - 27.07.2020 KW - Hazardous materials KW - Transport regulations KW - Flammable gases KW - Toxic gases PY - 2020 SP - Paper 1002 AN - OPUS4-51271 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Schmidt, Martin A1 - Uhlig, S. A1 - Kunath, K. T1 - Ringversuchsprogramm des "Center for quality assurance for testing of dangerous goods and hazardous substances" - aktueller Stand, Erfahrungen und Schlussfolgerungen T2 - Kolloquium mit den RV-Teilnehmern des AK "Brennbare Stäube" zum Thema: Ergebnisse und Schlussfolgerungen aus dem Interlaboratory test 2010/11 "DIN EN 15188:2007 - Self-ingnistion temperature" CY - Dresden DA - 2013-01-29 PY - 2013 AN - OPUS4-33495 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Schmidt, Martin A1 - Uhlig, S. A1 - Kunath, K. T1 - Datenprüfung und Güte der Labordaten im Validierungsringversuch Interlaboratory test 2010/11 "DIN EN 15188:2007 - Self-ignition temperature" T2 - Kolloquium mit den RV-Teilnehmern des AK "Brennbare Stäube" zum Thema: Ergebnisse und Schlussfolgerungen aus dem Interlaboratory test 2010/11 "DIN EN 15188:2007 - Self-ignition temperature" CY - Dresden DA - 2013-01-29 PY - 2013 AN - OPUS4-33496 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Uhlig, S. A1 - Frost, K. A1 - Malow, Marcus A1 - Michael-Schulz, Heike A1 - Schmidt, Martin A1 - Zakel, S. T1 - CEQAT-DGHS interlaboratory tests for chemical safety: Validation of laboratory test methods by determining the measurement uncertainty and probability of incorrect classification including so-called “Shark profiles” N2 - Laboratory test results are of vital importance for correctly classifying and labelling chemicals as “hazardous” as defined in the UN Globally Harmonized System (GHS) / EC CLP Regulation or as “dangerous goods” as defined in the UN Recommendations on the Transport of Dangerous Goods. Interlaboratory tests play a decisive role in assessing the reliability of laboratory test results. Interlaboratory tests performed over the last 10 years have examined different laboratory test methods. After analysing the results of these interlaboratory tests, the following conclusions can be drawn: 1. There is a need for improvement and validation for all laboratory test methods examined. 2. To avoid any discrepancy concerning the classification and labelling of chemicals, the use of validated laboratory test methods should be state of the art, with the results accompanied by the measurement uncertainty and (if applicable) the probability of incorrect classification. This paper addresses the probability of correct/incorrect classification (for example, as dangerous goods) on the basis of the measurement deviation obtained from interlaboratory tests performed by the Centre for quality assurance for testing of dangerous goods and hazardous substances (CEQAT-DGHS) to validate laboratory test methods. This paper outlines typical results (e.g. so-called “Shark profiles” – the probability of incorrect classification as a function of the true value estimated from interlaboratory test data) as well as general conclusions and steps to be taken to guarantee that laboratory test results are fit for purpose and of high quality. T2 - 13th International Symposium on Hazards, Prevention and Mitigation of Industrial Explosions (ISHPMIE 2020) CY - Braunschweig, Germany DA - 27.07.2020 KW - Dangerous goods KW - Hazardous substances KW - Interlaboratory test KW - Test method KW - Validation KW - Quality assurance KW - Measurement uncertainty KW - Incorrect classification KW - Shark profile PY - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-515376 UR - https://oar.ptb.de/files/download/5f3e662f4c93901010006dbf VL - 2020 SP - 50 EP - 61 PB - Open Access Repository der Physikalisch-Technischen Bundesanstalt (PTB-OAR) CY - Braunschweig AN - OPUS4-51537 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Malow, Marcus T1 - CEQAT-DGHS Ringversuchprogramm für die Chemikaliensicherheit - Probleme bei der Generierung kleiner Durchflüsse für ein Verfahren zur Verifizierung der Prüfapparatur gemäß Prüfmethode UN Test N.5 N2 - Ob Explosion in einem Chemiewerk oder Brand auf einem Gefahrgutfrachter – die Ursachen für Unfälle können vielfältig sein. Prävention beginnt bereits im Prüflabor, wenn Chemikalien auf ihre gefährlichen Eigenschaften getestet werden. Sicherheitsfachleute, Transporteure oder Händler müssen sich jedoch auf die richtige Durchführung der Prüfung und Bewertung verlassen können. Ringversuche, Referenzmaterialien, Verifizoierungsverfahren etc sind Mittel, um Prüfgeräte bzw. die Messergebisse auf ihre Zuverlässigkeit hin zu überprüfen. Im Vortrag ein an der BM neu entwickeltes Verifizierungsfahren für das Prüfverfahren UN-N.5 vorgestellt. Es wird hierbei gezeigt, dass Schwebekörperdurchflussmesser (Rotameter) zur Messung kleiner Durchflüsses nicht ausreichend zuverlässig sind. Es wird deshalb die Entwicklung eines alternativen, gravimetrischen Verifizierungsverfahrens diskutiert. T2 - BAM-PTB-Erfa Messung kleiner Durchflüsse CY - Braunschweig, Germany DA - 16.01.2020 KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Verifizierung KW - Validierung KW - Messunsicherheit KW - Qualitätsicherung KW - UN Test N.5 PY - 2020 AN - OPUS4-51538 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Frost, K. A1 - Kurth, Lutz A1 - Malow, Marcus A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. A1 - Zakel, S. T1 - CEQAT-DGHS Ringversuchsprogramm für die Chemikaliensicherheit - Schlussfolgerungen N2 - Die Ursachen für Chemikalienunfälle können vielfältig sein. Prävention beginnt bereits im Prüflabor, wenn Chemikalien auf ihre gefährlichen Eigenschaften getestet werden. Dazu sind Prüfmethoden entwickelt und veröffentlicht worden, die heute weltweit Anwendung finden. Auf die Validität der Prüfmethode und richtige Durchführung der Prüfung im Laboratorium müssen sich Sicherheitsfachkräfte, Transporteure oder Händler verlassen können. Anhand der in den letzten 10 Jahren im Rahmen des CEQAT-DGHS von BAM und PTB durchgeführten Ringversuche (RV) wird gezeigt, dass bei allen bisher untersuchten Prüfmethoden ein Verbesserungsbedarf besteht. Die RV müssen daher zunächst auf die Methodenverbesserung und -validierung abzielen und nicht auf Leistungstests. Das Labormanagement und die praktische Durchführung der Prüfung sind in vielen Laboratorien verbesserungsbedürftig. Der Begriff „Erfahrung der Prüfer“ ist kritisch zu sehen: Eine „lange Erfahrung mit vielen Prüfungen“ ist nicht unbedingt ein Garant für richtige Ergebnisse. T2 - 15. BAM-PTB-Kolloquium zur chemischen und physikalischen Sicherheitstechnik CY - Braunschweig, Germany DA - 21.05.2019 KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung PY - 2019 AN - OPUS4-49486 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Frost, K. A1 - Kurth, Lutz A1 - Malow, Marcus A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. A1 - Zakel, S. T1 - CEQAT-DGHS Ringversuchsprogramm für die Chemikaliensicherheit - Schlussfolgerungen N2 - Die Ursachen für Chemikalienunfälle können vielfältig sein. Prävention beginnt bereits im Prüflabor, wenn Chemikalien auf ihre gefährlichen Eigenschaften getestet werden. Dazu sind Prüfmethoden entwickelt und veröffentlicht worden, die heute weltweit Anwendung finden. Auf die Validität der Prüfmethode und richtige Durchführung der Prüfung im Laboratorium müssen sich Sicherheitsfachkräfte, Transporteure oder Händler verlassen können. Anhand der in den letzten 10 Jahren im Rahmen des CEQAT-DGHS von BAM und PTB durchgeführten Ringversuche (RV) wird gezeigt, dass bei allen bisher untersuchten Prüfmethoden ein Verbesserungsbedarf besteht. Die RV müssen daher zunächst auf die Methodenverbesserung und -validierung abzielen und nicht auf Leistungstests. Das Labormanagement und die praktische Durchführung der Prüfung sind in vielen Laboratorien verbesserungsbedürftig. Der Begriff „Erfahrung der Prüfer“ ist kritisch zu sehen: Eine „lange Erfahrung mit vielen Prüfungen“ ist nicht unbedingt ein Garant für richtige Ergebnisse. T2 - 15. BAM-PTB-Kolloquium zur chemischen und physikalischen Sicherheitstechnik CY - Braunschweig, Germany DA - 21.05.2019 KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung PY - 2019 UR - https://www.ptb.de/cms/index.php?id=18763 U6 - https://doi.org/10.7795/210.20190521M SP - 1 EP - 8 PB - Physikalisch-Technische Bundesanstalt (PTB) CY - Braunschweig AN - OPUS4-49489 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Frost, K. A1 - Kurth, Lutz A1 - Malow, Marcus A1 - Michael-Schulz, Heike A1 - Schmidt, Martin A1 - Uhlig, S. A1 - Zakel, S. T1 - CEQAT-DGHS Interlaboratory tests for method validation and measurement uncertainty determination N2 - An explosion in a chemical plant or a fire on a dangerous goods vessel - the reason for such accidents can be numerous. Prevention starts in the laboratory where chemicals are tested for their hazardous properties in order to be able to assess the risks involved in their handling. For this purpose, test methods have been developed and published. They are applied globally nowadays. Safety experts, manufacturers, suppliers, importers, employers or consumers must be able to rely on the validity of safety-related test methods and on correct test results and assessments in the laboratory. Interlaboratory tests play a decisive role in assessing the reliability of test results. Participation in interlaboratory tests is not only a crucial element of the quality assurance of laboratories; as such it is explicitly recommended in DIN EN ISO/IEC 17025. In addition, interlaboratory tests are also used to develop and validate test methods and can be used for the determination of the measurement uncertainty. Interlaboratory tests on different test methods have been performed by Bundesanstalt für Materialforschung und –prüfung (BAM) and Physikalisch-Technische Bundesanstalt (PTB) in collaboration with the QuoData GmbH during the last 10 years. Significant differences between the results of the participating laboratories were observed in all interlaboratory tests. The deviations of the test results were not caused only by laboratory faults but also by deficiencies of the test method (see interlaboratory test reports of the CEQAT-DGHS Centre for quality assurance for testing of dangerous goods and hazardous substances: www.ceqat-dghs.bam.de). In view of the interlaboratory test results the following conclusions can be drawn: • To avoid any discrepancy on classification and labelling of chemicals it should become state of the art to use validated test methods and the results accompanied by the measurement uncertainty. • A need for improvement is demonstrated for all examined test methods. Thus, interlaboratory tests shall initially aim at the development, improvement and validation of the test methods (including the determination of the measurement uncertainty) and not on proficiency tests. • The laboratory management and the practical execution of the tests need to be improved in many laboratories. • The term "experience of the examiner" must be seen critically: A "long experience with many tests" is not necessarily a guarantee for correct results. T2 - Eurachem International Workshop Uncertainty from sampling and analysis for accredited laboratories CY - Berlin, Germany DA - 19.11.2019 KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung KW - Messunsicherheit KW - Dangerous goods KW - Hazardous substances KW - Interlaboratory comparison KW - Quality assurance KW - Round robin test KW - Test method KW - Validation KW - Measurement uncertainty PY - 2019 UR - https://www.eurachem.org/index.php/events/completed/277-wks-mu2019#posters AN - OPUS4-49832 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Frost, K. A1 - Kurth, Lutz A1 - Malow, Marcus A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. A1 - Zakel, S. T1 - CEQAT-DGHS Ringversuchsprogramm für die Chemikaliensicherheit – Entwicklung von Verfahren zur Verifizierung der Prüfapparatur am Beispiel der Prüfmethode UN Test N.5 N2 - Prävention beginnt im Prüflabor, wenn Chemikalien auf ihre gefährlichen Eigenschaften getestet werden. Dazu sind Prüfmethoden entwickelt und veröffentlicht worden, die heute weltweit Anwendung finden. Auf die Validität der Prüfmethode und richtige Durchführung der Prüfung im Laboratorium müssen sich Sicherheitsfachkräfte, Transporteure oder Händler verlassen können. Anhand der in den letzten 10 Jahren im Rahmen des CEQAT-DGHS von BAM und PTB durchgeführten Ringversuche (RV) wird gezeigt, dass bei allen bisher untersuchten Prüfmethoden ein Verbesserungsbedarf besteht. Die RV müssen daher zunächst auf die Methodenverbesserung und -validierung abzielen und nicht auf Leistungstests. Das Labormanagement und die praktische Durchführung der Prüfung sind in vielen Laboratorien verbesserungsbedürftig. Der Begriff „Erfahrung der Prüfer“ ist kritisch zu sehen: Eine „lange Erfahrung mit vielen Prüfungen“ ist nicht unbedingt ein Garant für richtige Ergebnisse. Bei der Prüfung der gefährlichen Eigenschaften von Chemikalien sind Referenzmaterialen auf Grund der Instabilität in der Regel nicht verfügbar. Für Prüflaboratorien sind RV daher eine Alternative bei der Qualitätssicherung. RV sind jedoch aufwendig und können nur in relativ großen Zeitabständen durchgeführt werden. Es sind deshalb Verfahren zur Verifizierung z. B. der in den Laboratorien verwendeten Prüfapparaturen zu entwickeln. Die Entwicklung von Verifizierungsverfahren wird am Bespiel der Prüfmethode UN Test N.5 demonstriert. T2 - 15. BAM-PTB-Kolloquium zur chemischen und physikalischen Sicherheitstechnik CY - Braunschweig, Germany DA - 21.05.2019 KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung KW - Verifizierung PY - 2019 AN - OPUS4-49493 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Frost, K. A1 - Kurth, Lutz A1 - Malow, Marcus A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. A1 - Zakel, S. T1 - CEQAT-DGHS Ringversuchsprogramm für die Chemikaliensicherheit – Entwicklung von Verfahren zur Verifizierung der Prüfapparatur am Beispiel der Prüfmethode UN Test N.5 N2 - Prävention beginnt im Prüflabor, wenn Chemikalien auf ihre gefährlichen Eigenschaften getestet werden. Dazu sind Prüfmethoden entwickelt und veröffentlicht worden, die heute weltweit Anwendung finden. Auf die Validität der Prüfmethode und richtige Durchführung der Prüfung im Laboratorium müssen sich Sicherheitsfachkräfte, Transporteure oder Händler verlassen können. Anhand der in den letzten 10 Jahren im Rahmen des CEQAT-DGHS von BAM und PTB durchgeführten Ringversuche (RV) wird gezeigt, dass bei allen bisher untersuchten Prüfmethoden ein Verbesserungsbedarf besteht. Die RV müssen daher zunächst auf die Methodenverbesserung und -validierung abzielen und nicht auf Leistungstests. Das Labormanagement und die praktische Durchführung der Prüfung sind in vielen Laboratorien verbesserungsbedürftig. Der Begriff „Erfahrung der Prüfer“ ist kritisch zu sehen: Eine „lange Erfahrung mit vielen Prüfungen“ ist nicht unbedingt ein Garant für richtige Ergebnisse. Bei der Prüfung der gefährlichen Eigenschaften von Chemikalien sind Referenzmaterialen auf Grund der Instabilität in der Regel nicht verfügbar. Für Prüflaboratorien sind RV daher eine Alternative bei der Qualitätssicherung. RV sind jedoch aufwendig und können nur in relativ großen Zeitabständen durchgeführt werden. Es sind deshalb Verfahren zur Verifizierung z. B. der in den Laboratorien verwendeten Prüfapparaturen zu entwickeln. Die Entwicklung von Verifizierungsverfahren wird am Bespiel der Prüfmethode UN Test N.5 demonstriert. T2 - 15. BAM-PTB-Kolloquium zur chemischen und physikalischen Sicherheitstechnik CY - Braunschweig, Germany DA - 21.05.2019 KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung KW - Verifizierung PY - 2019 UR - https://www.ptb.de/cms/index.php?id=18763 U6 - https://doi.org/10.7795/210.20190521E SP - 1 EP - 10 CY - Braunschweig AN - OPUS4-49495 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lüth, Peter A1 - Frost, K. A1 - Kurth, Lutz A1 - Malow, Marcus A1 - Michael-Schulz, Heike A1 - Schmidt, Martin A1 - Schulte, Petra A1 - Uhlig, S. A1 - Zakel, S. T1 - CEQAT-DGHS Interlaboratory Test Programme for Chemical Safety - Need of Test Methods Validation N2 - Safety experts, manufacturers, suppliers, importers, employers or consumers must be able to rely on the validity of safety-related test methods and on correct test results and assessments in the laboratory. Via the eChemPortal lots of data from the REACH registration dossiers are available. However, the quality and correctness of the information remains in the responsibility of the data submitter. Unfortunately, we found more or less appropriate information on physicochemical properties and concluded that more quality or adequacy of any data submitted will be needed. Interlaboratory tests play a decisive role in assessing the reliability of test results. Interlaboratory tests on different test methods have been performed by Bundesanstalt für Materialforschung und –prüfung (BAM) and Physikalisch-Technische Bundesanstalt (PTB) in collaboration with the QuoData GmbH during the last 10 years. Significant differences between the results of the participating laboratories were observed in all interlaboratory tests. The deviations of the test results were not caused only by laboratory faults but also by deficiencies of the test method. In view of the interlaboratory test results the following conclusions can be drawn: • To avoid any discrepancy on classification and labelling of chemicals it should become state of the art to use validated test methods and the results accompanied by the measurement uncertainty. • A need for improvement is demonstrated for all examined test methods. Thus, interlaboratory tests shall initially aim at the development, improvement and validation of the test methods and not on proficiency tests. • The laboratory management and the practical execution of the tests need to be improved in many laboratories. • The term "experience of the examiner" must be seen critically: A "long experience with many tests" is not necessarily a guarantee for correct results. T2 - 16th International Symposium on Loss Prevention and Safety Promotion in the Process Industries and accompanying exhibition. Loss prevention 2019 CY - Delft, The Netherlands DA - 16.06.2019 KW - Dangerous goods KW - Hazardous substances KW - Round robin test KW - Interlaboratory comparison KW - Test method KW - Validation KW - Quality assurance PY - 2019 UR - https://www.aidic.it/cet/19/77/001.pdf SN - 978-88-95608-74-7 U6 - https://doi.org/10.3303/CET1977001 SN - 2283-9216 VL - 77 SP - 1 EP - 6 PB - Italian Association of Chemical Engineering AN - OPUS4-49496 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Brandes, E. A1 - Frost, K. A1 - Kurth, Lutz A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. T1 - CEQAT-DGHS Ringversuchsprogramm für die Chemikaliensicherheit – Methodenvalidierung N2 - Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und –prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS). Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung und auf die Bestimmung der Messunsicherheit der jeweiligen Prüfmethode abzielen und nicht auf Leistungstests. T2 - 13. Fachtagung Anlagen-, Arbeits- und Umweltsicherheit CY - Köthen, Germany DA - 16.11.2017 KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung PY - 2017 SN - 978-3-96057-032-5 SP - 1 EP - 13 CY - Köthen AN - OPUS4-43299 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Brandes, E. A1 - Frost, K. A1 - Kurth, Lutz A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. T1 - CEQAT-DGHS Ringversuchsprogramm für die Chemikaliensicherheit – Methodenvalidierung N2 - Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und –prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS). Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung und auf die Bestimmung der Messunsicherheit der jeweiligen Prüfmethode abzielen und nicht auf Leistungstests. T2 - 13. Fachtagung Anlagen-, Arbeits- und Umweltsicherheit CY - Köthen, Germany DA - 16.11.2017 KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung PY - 2017 AN - OPUS4-43300 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Brandes, E. A1 - Frost, K. A1 - Kurth, Lutz A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. T1 - CEQAT-DGHS Ringversuchsprogramm für die Chemikaliensicherheit – Methodenvalidierung N2 - Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und –prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS). Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung und auf die Bestimmung der Messunsicherheit der jeweiligen Prüfmethode abzielen und nicht auf Leistungstests. T2 - 13. Fachtagung Anlagen-, Arbeits- und Umweltsicherheit CY - Köthen, Germany DA - 16.11.2017 KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung PY - 2017 AN - OPUS4-43301 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Brandes, E. A1 - Frost, K. A1 - Kurth, Lutz A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. T1 - CEQAT-DGHS Ringversuchsprogramm für die Chemikaliensicherheit – Messunsicherheit und die Bedeutung von Ringversuchen zur Methodenvalidierung N2 - Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und –prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS). Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung und auf die Bestimmung der Messunsicherheit der jeweiligen Prüfmethode abzielen und nicht auf Leistungstests. T2 - Workshop: Arbeiten mit ProLab und ProLab Plus Planung und statistische Auswertung von Ringversuchen zur Methodenvalidierung CY - Dresden, Germany DA - 03.05.2017 KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung PY - 2017 AN - OPUS4-40094 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schmidt, Martin A1 - Lüth, Peter T1 - Wie sicher ist die Bestimmung des Selbstentzündungsverhaltens großer Feststoffschüttungen? N2 - Für die Klassifizierung sowie die sichere Handhabung und Nutzung von Chemikalien und anderen Stoffen wurden spezielle standardisierte Testmethoden entwickelt, die weltweit zum Einsatz kommen. Die Ableitung von Sicherheitsmaßnahmen durch Experten erfordert, dass aus diesen Untersuchungen verlässliche Daten gewonnen werden. Ringversuche sind ein wesentliches Element bei der Methodenentwicklung (-validierung) und für die Qualitätssicherung von Laboratorien. Die Testmethode DIN EN 15188:2007 dient der Bestimmung des Selbstentzündungsverhaltens von Schüttgütern und Stäuben. Experimentelle Grundlage für die Beschreibung des Selbstentzündungsverhaltens eines bestimmten Materials ist die Bestimmung der Selbstentzündungstemperaturen (TSE) von Proben verschiedener Größen mit Hilfe isoperiboler Warmlagerungsversuche. Die so ermittelten Versuchsdaten ergeben die Abhängigkeit der Selbstentzündungstemperaturen vom Lagervolumen. Zweck einer schrittweise aufgebauten Serie von Ringversuchen und internen Labortests war die Identifizierung von Schwächen der bestehenden Methode bzw. von in der Laborpraxis auftretenden Mängeln bei der Anwendung der Methode, die Validierung der modifizierten und verbesserten Methode sowie die Bestimmung einer allgemeingültigen (Mess-)Unsicherheit dieser modifizierten Methode. T2 - VDI-Fachtagung "Sichere Handhabung brennbarer Stäube" CY - Nürnberg, Germany DA - 24.10.2017 KW - Selbstentzündung KW - Methodenvalidierung KW - Messunsicherheit KW - Ringversuch PY - 2017 SN - 978-3-18092-314-7 SN - 0083-5560 VL - 2314 SP - 95 EP - 105 PB - VDI Verlag GmbH CY - Düsseldorf AN - OPUS4-45815 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Brandes, E. A1 - Colson, B. A1 - Frost, K. A1 - Lüth, Peter A1 - Simon, K. A1 - Stolz, T. A1 - Uhlig, S. T1 - Evaluation of the interlaboratory test 2015 – 2016 on the method UN Test L.2 “Sustained combustibility test” / EN ISO 9038:2013 “Determination of sustained combustibility of liquids" N2 - The test methods UN Test L.2 / EN ISO 9038:2013 DIN EN 15188:2007 are applied to characterize the sustained combustibility of liquids i.e. the behaviour of a material under specified test conditions, whereby its vapour can be ignited by an ignition source and sufficient flammable vapour is produced to continue burning for at least 15 s after the source of ignition has been removed. The aims of this interlaboratory test (IT) are the verification and/or the improvement (if necessary) of the verification data (reference material) in Annex B of EN ISO 9038:2013, the assessment of influencing (disturbing) factors (laboratory specific factors, which possibly may have an influence on the test result) and the assessment of the performance of the participating laboratories. It could be demonstrated that the reference materials n-Dodecane, n-Decane and n-Undecane as mentioned in the standard are suitable and the verification shall continue to be valid. Sustained combustibility tests are influenced by several factors like the presence of a draught shield, the experience of the laboratory assistant, verification of the apparatus, calibration of the metering device. Based on the interlaboratory test, the gained experience and the actual results, well-founded measures / actions can be recommended to improve execution of the method. The IT was organized by PTB, BAM and QuoData GmbH in the framework of the co-operation project CEQAT-DGHS Centre for Quality Assurance for Testing of Dangerous Goods and Hazardous Substances. KW - Dangerous goods KW - Hazardous substances KW - Test method KW - Quality assurance KW - Interlaboratory comparison KW - Round robin test KW - Validation KW - Sustained combustibility KW - Reference material KW - Gefahrgut KW - Gefahrstoff KW - Prüfmethode KW - Qualitätssicherung KW - Ringversuch KW - Validierung KW - Selbstunterhaltende Verbrennung KW - Referenzmaterial PY - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-410270 SN - 978-3-9818270-3-3 SP - 1 EP - 103 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-41027 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -