TY - CONF A1 - Osterloh, Kurt A1 - Fratzscher, Daniel A1 - Jechow, Mirko A1 - Bücherl, T. A1 - Schillinger, B. A1 - Hasenstab, A. A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Limited view tomography of wood with fast and thermal neutrons N2 - Neutrons are absorbed particularly by hydrogen containing materials so they can be used as a tool for visualising heterogeneous density distributions of organic materials. Penetration limits are set by the layer thicknesses and the neutron energies applied. In case of specimens with a flat shape the situation may be encountered that the object only could be penetrated in selected directions. In addition, the overall size may exceed the beam diameter and thus the viewing window if a certain region of interest should be studied by tomography without destroying the integrity of the specimen. This study shows the capabilities and limits of thermal and fast neutrons to investigate flat wooden specimens such as boards and girders by neutron tomography under such circumstances. Taking projections was impaired either by the limits of penetrability or by the total size of the object. As a consequence, projections were included for reconstruction only from a limited angular range of 90°. It could be shown that an approach based on the slice theorem was capable to visualise structural features along the beam directions while simply omitting the perpendicular ones without causing additional artefacts. Small samples with a thickness of up to 2 cm but several times broader could be studied with the ANTARES facility of the FRM II neutron source in Garching providing thermal neutrons while larger objects required a beam of higher energy as available in the NECTAR facility of the same institution. The fast (fission) neutrons (1.5 – 2 MeV) of this site allowed investigating an area of interest inside a girder with a cross section of 23.5 x 49 cm². Internal features such as inclusions could be detected as well as a heterogeneous density distribution in glue layers. T2 - International symposium on digital industrial radiology and computed tomography CY - Berlin, Germany DA - 20.06.2011 KW - Computed tomography KW - Slice theoreme KW - Limited angle tomography PY - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-250663 SN - 978-3-940283-34-4 VL - 128 SP - 1 EP - 5 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-25066 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe A1 - Heyne, Klara A1 - Zscherpel, Uwe A1 - Jechow, Mirko A1 - Bavendiek, K. ED - Thompson, D.O. ED - Chimenti, D.E. T1 - Optimum exposure conditions for computed radiography depending on fixed pattern noise and efficiency of imaging plate-scanner systems N2 - The presently active standards on Computed Radiography (CR) need a major revision. It was observed by many users that the image quality for class B of EN 14784-2 is not achievable under the same exposure conditions as used for film exposure. A mathematical model was developed and tested, which allows the calculation of the image quality, proven by image quality indicators (IQI), depending on the fixed pattern noise and the efficiency of the used imaging plate (IP) scanner system. All tested IP scanner systems provide a fixed correlation between the measured signal/noise ratio (SNR) and the grey values in the digital images. The maximum achievable SNRmax depends on the fixed pattern noise of the plate (high dose limit). Depending on the exposure dose an optimum visibility of IQIs can be predicted by calculation and measured considering the attenuation coefficient for calculation of the contrast/noise ratio (CNR). The diameter of the just visible wire is proportional to 1/sqrt(CNR). The optimum tube voltage for best visibility of IQIs and maximum CNR depend on the exposure dose. The optimum tube voltage for best visibility is achieved only at exposures with high dose. A dose dependant optimal tube voltage was not observed for film radiography. T2 - 37th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - San Diego, CA, USA DA - 18.07.2010 KW - Computed radiography KW - Computed radiology KW - Non destructive testing KW - Image quality KW - Signal-to-noise ratio KW - Contrast-to-noise ratio KW - Imaging plates KW - Optimum tube voltage KW - Standards PY - 2011 SN - 978-0-7354-0888-3 U6 - https://doi.org/10.1063/1.3591892 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings IS - 1335 SP - 493 EP - 500 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-27540 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Ewert, Uwe A1 - Jechow, Mirko T1 - Scatter radiation in radiography T2 - 10th European conference on non-destructive testing CY - Moscow, Russia DA - 2010-06-07 KW - Simulation KW - Streustrahlung KW - Abbildungskontrast KW - Bildqualität PY - 2010 IS - Paper 4.02.18 SP - 1 EP - 9 AN - OPUS4-22765 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Osterloh, Kurt A1 - Wrobel, Norma A1 - Fratzscher, Daniel A1 - Jechow, Mirko A1 - Zscherpel, Uwe A1 - Ewert, Uwe A1 - Hasenstab, A. T1 - Backscatter radiation - using X-rays for illumination T2 - MATEST 2009 CY - Cavtat/Dubrovnik, Croatia DA - 2009-09-23 KW - X-ray back scatter KW - Unilateral access KW - Twisted slit collimator KW - Pinhole camera principle with high energy radiation PY - 2009 SN - 978-953-7283-03-2 IS - #12 SP - 1 EP - 11 AN - OPUS4-20709 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zscherpel, Uwe A1 - Ewert, Uwe A1 - Jechow, Mirko ED - Thompson, D. O. ED - Chimenti, D. E. T1 - Concepts for evaluation of image quality in digital radiology N2 - Concepts for digital image evaluation are presented for Computed Radiography (CR) and Digital Detector Arrays (DDAs) used for weld inspection. The precise DDA calibration yields an extra ordinary increase of contrast sensitivity up to 10 times in relation to film radiography. Restrictions in spatial resolution caused by pixel size of the DDA are compensated by increased contrast sensitivity. First CR standards were published in 2005 to support the application of phosphor imaging plates in lieu of X-ray film, but they need already a revision based on experiences reported by many users. One of the key concepts is the usage of signal-to-noise (SNR) measurements as equivalent to the optical density of film and film system class. The contrast sensitivity, measured by IQI visibility, depends on three essential parameters: The basic spatial resolution (SRb) of the radiographic image, the achieved signal-to-noise ratio (SNR) and the specific contrast (µeff - effective attenuation coefficient). Knowing these 3 parameters for the given exposure condition, inspected material and monitor viewing condition permits the calculation of the just visible IQI element. Furthermore, this enables the optimization of exposure conditions. The new ISO/FDIS 17636-2 describes the practice for digital radiography with CR and DDAs. It considers the first time compensation principles, derived from the three essential parameters. The consequences are described. T2 - 38th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Burlington, VT, USA DA - 2011-07-17 KW - Image resolution KW - Inspection KW - Production engineering computing KW - Radiography KW - Welding KW - X-ray imaging KW - ZfP KW - Radiographie KW - Bildqualität KW - Filmersatz KW - Digitale Detektoren PY - 2012 SN - 978-0-7354-1013-8 U6 - https://doi.org/10.1063/1.4716281 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings IS - 1430 SP - 589 EP - 596 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-26697 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Heyne, Klara A1 - Jechow, Mirko A1 - Bavendiek, K. T1 - Image quality in digital industrial radiography KW - ZfP KW - Radiographie KW - Bildqualität KW - Digitale Detektoren PY - 2012 SN - 0025-5327 VL - 70 IS - 8 SP - 955 EP - 964 PB - Society for Nondestructive Testing CY - Columbus, Ohio AN - OPUS4-26699 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Deresch, Andreas A1 - Jechow, Mirko A1 - Gollwitzer, Christian ED - Chimenti, D.E. ED - Bond, L.J. ED - Thompson, D.O. T1 - Spectral characterization of storage phosphor imaging plates N2 - This work presents attenuation and sensitivity measurements of radiographic imaging plates (IPs) with quasimonoenergetic X-rays in the 8–60 kiloelectronvolt range. The measurements are used to validate theoretical predictions. A short overview of the theoretical model is given. The model can be used to describe the sensitivity of different detector types to a wide range of X-ray energies. T2 - 40th Annual review of progress in quantitative nondestructive evaluation CY - Baltimore, Maryland, USA DA - 21.07.2013 KW - Radiography KW - Imaging plates KW - Spectral sensitivity PY - 2014 SN - 978-0-7354-1212-5 SN - 978-0-7354-1211-8 U6 - https://doi.org/10.1063/1.4865040 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings VL - 1581 SP - 1786 EP - 1792 PB - AIP Publishing AN - OPUS4-30757 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -