TY - CONF A1 - Goebbels, Jürgen A1 - Illerhaus, Bernhard A1 - Dietrich, H.-G. A1 - Neuhaus, M. ED - Brücker, C. T1 - Drucksondierungen, teufengenaue Probenahme und Präparation MKW-kontaminierter Lockersedimente T2 - 5. Workshop "Bohrlochgeophysik und Gesteinsphysik" (Mitteilungen / Deutsche Geophysikalische Gesellschaft e.V. 2000, Sonderbd. 3) T2 - 5. Workshop "Bohrlochgeophysik und Gesteinsphysik" CY - Hannover, Deutschland DA - 1999-10-07 PY - 2000 SN - 0947-1944 VL - 3 SP - 12 EP - 17 AN - OPUS4-1036 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weidemann, Gerd A1 - Goebbels, Jürgen A1 - Illerhaus, Bernhard A1 - Dittrich, R. A1 - Mangler, M. A1 - Tomandl, G. T1 - Charakterisierung von Gradientenwerkstoffen mittels hochauflösender Computertomographie T2 - ZfP in Anwendung, Entwicklung und Forschung - Jahrestagung 2001 T2 - Jahrestagung Zerstörungsfreie Materialprüfung 2001 CY - Berlin, Deutschland DA - 2001-05-21 PY - 2001 UR - http://www.ndt.net/article/dgzfp01/papers/p16/p16.htm N1 - Serientitel: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. – Series title: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. IS - 75-CD PB - DGZfP CY - Berlin AN - OPUS4-1128 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Badde, Aurelia A1 - Illerhaus, Bernhard ED - Salimbeni, R. T1 - 3D - my CT reveals the work processes of cast plaster statues, their internal structures, damages and restorations T2 - Optical methods for arts and archaeology T2 - Optical Methods for Arts and Archaeology CY - Munich, Germany DA - 2005-06-13 KW - Cast plaster statues KW - Computerized tomography KW - 3D-micro-CT KW - Internal structure KW - Conservation KW - Restoration PY - 2005 SN - 0-8194-5857-0 N1 - Serientitel: Proceedings of SPIE – Series title: Proceedings of SPIE IS - 5857 SP - 58570U-1 - 58570U-8 PB - SPIE CY - Bellingham AN - OPUS4-11259 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. A1 - Illerhaus, Bernhard A1 - Goebbels, Jürgen A1 - Bamberg, J. A1 - Heutling, F. T1 - X-Ray Refraction Topography and Computed Tomography for NDE of Lightweight Materials T2 - 9th European Conference on NDT T2 - 9th European Conference on NDT CY - Berlin, Germany DA - 2006-09-25 KW - Synchrotron Refraction CT KW - MMC KW - Bragg-Magnification PY - 2006 SN - 3-931381-86-2 SP - 1(?) EP - 9(?) PB - European Federation for Non-Destructive Testing CY - Berlin AN - OPUS4-13703 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Marco A1 - Hentschel, Manfred P. A1 - Illerhaus, Bernhard A1 - Goebbels, Jürgen T1 - Synchrotron Refraction CT and Synchrotron Bragg Magnification CT for NDE T2 - International Symposium on Digital industrial Radiology and Computed Tomography (DIR 2007), June 25-27, 2007, Lyon, France (Proceedings) T2 - International Symposium on Digital industrial Radiology and Computed Tomography (DIR 2007) CY - Lyon, France DA - 2007-06-25 KW - X-ray Refraction KW - Diffraction Enhanced Imaging (DEI) KW - Bragg Magnification KW - Synchrotron Radiation KW - Computed Tomography (CT) KW - Metal Matrix Composites (MMC) KW - Lightweight Materials KW - Aerospace PY - 2007 IS - CD-ROM SP - 1 EP - 8 CY - Lyon, France AN - OPUS4-16366 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Illerhaus, Bernhard A1 - Spreemann, M. T1 - Making use of phase-contrast in dimensional muCT-measurements of weakly absorbing objects T2 - Conference on industrial computed tomography (ICT) 2014 (Proceedings) N2 - The effects of refraction (phase-contrast) are normally considered as disturbances in high-resolution μCT-measurements. We show that in the case of small objects with low absorption a single-distance phase-retrieval algorithm not only reduces the edge enhancement, but also raises the signal-to-noise ratio sufficiently to allow dimensional measurements. This is exemplified at an optical element for optical fibre connectors. T2 - Conference on industrial computed tomography (ICT) 2014 CY - Wels, Austria DA - 2014-02-25 PY - 2014 SN - 978-3-8440-2557-6 SN - 1610-4773 SP - 405 EP - 410 PB - Shaker Verlag GmbH AN - OPUS4-30325 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Illerhaus, Bernhard A1 - Onel, Yener T1 - Mehr Strom oder mehr Spannung, ein Vergleich drei Röntgenröhren in der CT T2 - DGZfP-Jahrestagung 2014 (Proceedings) N2 - Sollten CT Aufnahmen quantitativ und automatisch ausgewertet werden, ist die Qualität der Tomogramme ein wesentlicher Punkt. Außerdem steht bei Serienmessungen nur eine begrenzte Meßzeit für jede Probe. Es werden die verschiedenen Mikrofokusröhren in Bezug auf die Parameter Orts- und Dichteauflösung, sowie Meßzeit verglichen, CT Beispiele dazu gezeigt. T2 - DGZfP-Jahrestagung 2014 CY - Potsdam, Germany DA - 26.05.2014 KW - Computertomographie KW - Ortsauflösung KW - Röhrenvergleich PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-307629 SN - 978-3-940283-61-0 IS - DGZfP-BB 148 SP - Di.1A.1, 1 EP - 9 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-30762 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bruno, Giovanni A1 - Ehrig, Karsten A1 - Haarring, Holger A1 - Harwardt, Michael A1 - Hentschel, Manfred P. A1 - Illerhaus, Bernhard A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Meinel, Dietmar A1 - Müller, Bernd R. A1 - Onel, Yener A1 - Staude, Andreas A1 - Wolk, Thomas T1 - Industrial and synchrotron X-ray CT applications for materials characterisation T2 - Conference on Industrial Computed Tomography (ICT) 2014 - Proceedings N2 - The combination of tomographic, microstructural data with other experimental techniques and with modeling is paramount, if we want to extract the maximum amount of information on material and component properties. In particular, quantitative image analysis, statistical approaches, direct discretization of tomographic reconstructions represent concrete possibilities to extend the power of the tomographic 3D representation to insights into the material and component performance. This logic thread holds equally for industrial and academic research, and valorizes expensive experiments such as those carried out at synchrotron sources, which cannot be daily repeated. We shall show a few examples of possible use of X-ray tomographic data for quantitative assessment of damage evolution and microstructural properties, as well as for non-destructive testing. We will also show how X-ray refraction computed tomography (CT) can be highly complementary to classic absorption CT, being sensitive to internal interfaces. T2 - iCT Conference 2014 - Conference on industrial computed tomography CY - Wels, Austria DA - 25.02.2014 KW - X-ray absorption and refraction CT KW - Quantitative image analysis KW - Statistical analysis KW - Complex microstructure PY - 2014 SN - 978-3-8440-2557-6 SP - 15 EP - 31 PB - Shaker CY - Aachen AN - OPUS4-30484 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bienge, J.-E. A1 - Illerhaus, Bernhard A1 - Epperlein, J. ED - Szallies, agrathaer GmbH, Isabell T1 - Blick in den Boden T2 - 20 Jahre Praxisversuch Lietzen Ackerbau und Forschung auf dem Weg in die Zukunft Feldtag in der Komturei Lietzen N2 - Computertomographische Untersuchungen in einer Studie zum vergleichenden Wurzelwachstum von Raps unter verschiedenen Bedingungen der Bodenbearbeitung. T2 - 20 Jahre Praxisversuch Lietzen Ackerbau und Forschung auf dem Weg in die Zukunft Feldtag in der Komturei Lietzen CY - Komturei Lietzen, Germany DA - 19.5.2016 KW - Computer Tomographie PY - 2016 SP - 28 EP - 29 AN - OPUS4-38144 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Illerhaus, Bernhard A1 - Maenz, S. A1 - Bischoff, S. A1 - Bungartz, M. A1 - Bossert, J. A1 - Kunisch, E. A1 - Kinne, R. ED - Maenz, S. T1 - Micro computer tomography (μCT) set-up for long-term serial measurements, image evaluation, and subsequent compressive strength tests on frozen sheep vertebrae for osteoporosis research T2 - Proceedings of the WCNDT2016 N2 - Injection of poly(methyl methacrylate) cements, one standard Treatment for osteoporotic vertebral body fractures, may lead to critical loads and subsequent fractures in adjacent vertebral bodies. Biodegradable calcium phosphate cements (CPC) with bioinductive growth factors may be an alternative, since they have a Young’s modulus comparable to that of cancellous bone. Non-destructive tests with μCT and quantitative Image evaluation are used to assess new bone growth and material resorption following intravertebral injection of CPC. Immediate deep-freezing of excised bone prevents shrinkage or tissue disintegration and the samples have to be kept frozen for all following steps, including transport, μCT measurements, and subsequent biomechanical tests. Here we will report on a set-up to preserve the frozen state of the material and allow stable long-term serial μCT measurements. In addition, the image processing technique for the evaluation of bone growth and selected results on subsequently carried out compressive strength tests will be presented. T2 - WCNDT2016 CY - München, Germany DA - 13.6.2016 KW - Computed tomography KW - Osteoporosis KW - CT PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-366410 UR - https://www.ndt.net/?id=19382 VL - BB 158 SP - 1 EP - 7 PB - DGZfP CY - Berlin AN - OPUS4-36641 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Illerhaus, Bernhard A1 - Kunisch, E. A1 - Kinne, R. W. T1 - Serial in situ compression of spongiosa cylinder observed by μCT, compared to simulated stress, strain, and movement T2 - Proceedings of 12th ECNDT, Gothenburg, Sweden N2 - Minimally invasive injection of calcium phosphate cement into bone defects in aged sheep vertebrae has been used as a model for the treatment of osteoporotic vertebral fractures. One of the therapeutic criteria is a compression test of non-treated or treated vertebral bodies. In the present study, an in situ compression test with a stepwise load increase was performed with small spongiosa cylinders from the vertebrae under continuous monitoring by μCT. This allows localization of bone cracks and the visualization of correct placement and form of the bone cylinder. In addition, the effects of an uneven load distribution on the sample due to an irregular shape and a subsequent underperformance of the test sample can be excluded by controlling its shape under increasing load. There was a good agreement between the measured data and those obtained by simulated load-dependent transformation on the basis of a digital volume correlation between consecutive compression tests on the bone surface under the assumption of homogeneous bone material. Mechanic simulation was executed by directly using structural voxel data, resulting in maps of Von Mise stresses and predicted displacements. T2 - 12th ECNDT CY - Gothenburg, Sweden DA - 11.6.2018 KW - Computed tomography KW - In-situ compression KW - Simulation PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-453317 SN - 978-91-639-6217-2 SP - 0162, 1 EP - 7 AN - OPUS4-45331 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Illerhaus, Bernhard A1 - Kunisch, E. A1 - Kinne, R. W. T1 - μCT begleitete in-situ Druckversuche an spongiösem Knochen - Vergleich(ende Bestimmung) des experimentellen und simulierten Verschiebungsfeldes mit der simulierten internen Spannung T2 - DGZfP-Jahrestagung 2018 N2 - Untersuchungen haben gezeigt, dass sich ältere Schafe gut als Modell für die mi-nimalinvasive Behandlung von Osteoporose eignen [1]. Um einen Behandlungs-effekt nachzuweisen, wird dabei unter anderem die Belastungsfähigkeit des Kno-chens durch Druckversuche an kleinen Zylindern aus den behandelten und unbe-handelten Knochen bestimmt. Diese hatten hier einen Durchmesser von 10 mm und eine Höhe von 13 mm. Für den in-situ Druckversuch wurde eine Deben CT5000 verwendet. In einer Serie von Druckerhöhungen wurden die Proben je-weils tomographiert. Dabei ergab sich zunächst, dass mit der µCT innerhalb der Knochen im oberen und unteren Bereich schon Brüche nachgewiesen werden können, obwohl die gemessene Kraftaufnahmekurve keine Unstetigkeit zeigt. Deswegen wurden die starren Probenaufnehmer der Deben Anordnung durch bewegliche Aufnehmer ergänzt, die eine leichte Verkippung der belasteten Ober-flächen ausgleichen können. Ein Vergleich der gemessenen und der aus den µCT-Daten berechneten Verschiebungsfelder ergab trotz der komplexen Struktur der Knochen gute Übereinstimmungen. Diese Verschiebungen wurden dann mit den aus den µCT Daten simulierten mechanischen Druckversuchen, Von-Mise-Spannungen und daraus berechneten Verschiebungen verglichen. (VGStudioMax Simulation). T2 - DGZfP-Jahrestagung CY - Leipzig, Germany DA - 07.05.2018 KW - Computer Tomographie KW - In-situ Druckversuch KW - Simulation PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-448827 UR - https://www.ndt.net/?id=23080 SN - 978-3-940283-92-4 VL - DGZfP BB 166 SP - 1 EP - 7 PB - DGZfP CY - Berlin AN - OPUS4-44882 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Illerhaus, Bernhard A1 - Badde, Aurelia A1 - Michaelis, Matthias A1 - Berger, U. A1 - Onel, Yener A1 - Meinel, Dietmar A1 - Goebbels, Jürgen T1 - Einsatz von mobilen Röntgenuntersuchungsmethoden im Museum - Zwei Fallbeispiele T2 - DGZfP-Jahrestagung 2010 N2 - Zwei Bildhauermodelle aus dem Georg-Kolbe-Museum Berlin standen zur Restaurierung an. Das kleinere, 'Lucino' (1920), 41cm, wurde hochauflösend mit CT gemessen, da mittels CT sowohl der Herstellungsprozeß einer Gipsstatue als auch der innere Zustand, wie Ergänzungen, Klebungen und Armierungen, festgestellt werden können. Aus den CT Bildern ergab sich eine für die vorher vermutete Gipszusammensetzung ungewöhnliche innere Struktur. Mit einer Freihand bedienten Röntgenpistole zur Messung der Röntgenfluoreszenz wurde daraufhin die Zusammensetzung des Materials der Statuette als Terracotta bestimmt. Durch den Einsatz von Helium als Spülmittel konnten auch leichte Materialien nachgewiesen und so eine Unterscheidung zwischen Gips und gebranntem Ton durchgeführt werden. Aus den CT Daten wurde eine virtuelle Darstellung der äußeren Geometrie gewonnen. Ein damit versuchsweise erstelltes Replik (Rapid Prototyping, 3D-Drucker, TU-Berlin) entsprach nicht den Anforderungen des Museums zur Erstellung einer Gußform für eine Bronzekleinserie der Statuette. Die zweite Statue, die 'Große Nacht' (1930) ist mit ihrer Größe von 2,12m und aufgrund des durch korrodierende Metallarmierung verursachten Schadensbildes nicht mehr transportfähig. Eine in-situ Untersuchung mit dem mobilen Tomographen, der in den 1980ern zur Untersuchung von Bäumen gebaut und jetzt mit einem modernen Flachdetektor und einer Röntgenröhre ausgestattet ist, wird vorgestellt. Die Möglichkeiten der in-situ CT für große Skulpturen werden anhand der Ergebnisse diskutiert. T2 - DGZfP-Jahrestagung 2010 CY - Erfurt, Deutschland DA - 2010-05-10 KW - Mobile CT KW - Mobile RFA PY - 2010 SN - 978-3-940283-26-9 IS - DGZfP-BB 122 (P12) SP - 1 EP - 8 CY - Berlin AN - OPUS4-24695 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Morys, Michael A1 - Illerhaus, Bernhard A1 - Sturm, Heinz A1 - Schartel, Bernhard T1 - Revealing the inner secrets of intumescent chars by advanced small scale tests combined with µ-CT T2 - Fire and materials 2015 - 14th International conference and exhibition (Proceedings) N2 - Testing of intumescent coatings for Steel is usually done in intermediate scale or even full scale experiments and is hence quite expensive. We developed two complementary small scale tests, simulating fully developed Tire. First is a strongly modified electrical muffle furnace, which is now able to follow the Standard temperature-time curve (according EN 1363-1) for 90 min in a very accurate manner. Düring the experiment backside temperatures are recorded and the growth of the char is observed with a custom made high temperature endoscope. Second is a testing apparatus based on a propane-oxygen-bumer for direct severe flame impingement of coated samples, reaching temperatures far above 1500 °C. Our small scale samples are coated Steel plates of a size of 75 x 75 x 2 mm3. The structure-propertyrelation between additives, thermal properties and morphology of the char were examined using a well determined series of samples consisting of basic composition mixed with different additives. With the burner-testing-apparatus we studied the behavior of a high performance coating, which shows a transformation of the carbonaceous char into a ceramic foam at temperatures as high as 1600 °C. Nondestructive micro-computed tomography was used to characterize the morphology of the char. According to the structure of the foams we used different analytic methods like cell-detection or wallthickness-analysis. Additional scanning electron and optical microscopy were performed. The combination of the CT-data with the measured backside temperatures of the different samples provides us a deep understanding of the interaction between isolating properties and morphology of intumescent chars. T2 - Fire and materials 2015 - 14th International conference and exhibition CY - San Francisco, CA, USA DA - 02.02.2015 PY - 2015 SP - 478 EP - 483 PB - Interscience Communications AN - OPUS4-32710 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -