TY - JOUR A1 - Wu, Dejian A1 - Schmidt, Martin A1 - Huang, W. A1 - Wei, A. A1 - Krause, U. A1 - Wu, W. T1 - Inhibition effect of N2/CO2 blends on the minimum explosion concentration of agriculture and coal dusts N2 - Minimum explosion concentration (MEC) of three agriculture dusts and two coal dusts was studied via a 20-L explosion chamber to reveal the role of gaseous inhibitors. Both active method (CO2 diluting air) and passive method (CO2 replacing O2) were used. The TG and DTG thermal analysis tests were conducted to study the pyrolysis and combustion characteristics of dust samples. An alternative explosion criterion based on combustion duration time was used to determine MEC, and compared with the standardized overpressure method. Under 10-kJ ignition condition, as oxygen mole fraction (XO2) decreased from 21% to 10%, MEC of agriculture dusts and coal dusts respectively increased by around 5 times and 2 times. The active inerting method with a lower N2/CO2 ratio was found to have a better suppression effect on the explosion of the five carbonaceous dusts because the blend has a higher specific heat and a lower oxygen diffusion rate. KW - CO2/N2 ratio KW - Explosion criterion KW - Combustion kinetics KW - Inerting effect KW - Explosion characteristics PY - 2022 U6 - https://doi.org/10.1016/j.powtec.2022.117195 SN - 0032-5910 VL - 399 SP - 1 EP - 12 PB - Elsevier B.V. AN - OPUS4-55013 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ren, K. A1 - Guo, Y. A1 - Huang, W. A1 - Wei, A. A1 - Wu, Dejian T1 - Explosion characteristics of coal dusts in O2/N2 ambience: A novel method to determine limiting oxygen concentration N2 - The explosion characteristics of anthracite and bituminous coals in O2/N2 ambience were experimentally studied via a 20-L spherical explosion chamber with various ignition energies of 2, 5 and 10 kJ. A novel method based on combustion duration time was proposed for the first time, with an emphasis on the determination of the limiting oxygen concentration (LOC). The values of LOC determined by the alternative method were almost consistent with those obtained by using the standardized overpressure method, where the LOCs were above 21.6%, 19.8%, and 13.2% for anthracite coal and 11.4%, 9.6%, and 9.0% for bituminous coal when the ignition energy is 2, 5, and 10 kJ, respectively. But the newly proposed method was found to be much less affected by the ignition energy compared with the standardized overpressure method, taking combustion duration time as an explosion criterion thus had a higher efficiency and required fewer experiments. The results also showed that as oxygen concentration decreases from 21.6% to 14.4%, the maximum explosion pressure decreases from 0.4334 MPa to 0.1034 MPa for anthracite coal and from 0.5664 MPa to 0.3981 MPa for bituminous coal, respectively. Moreover, the effect of ignition energy varied with varying volatile matter content and ignition mechanism of coal dusts. The higher the volatile content, the less sensitive it is to the ignition energy. The newly proposed method will provide a reference for the new standard development, hazard analysis, explosion prevention and suppression by involving the use of inert gases of combustible powder industries. KW - Limiting oxygen concentration KW - Ignition energy KW - Coal dusts KW - Combustion duration time KW - Explosion criterion PY - 2022 U6 - https://doi.org/10.1016/j.fuel.2022.124673 SN - 0016-2361 VL - 324, Part B SP - 1 EP - 11 PB - Elsevier Ltd. AN - OPUS4-55051 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Guo, Y. A1 - Ren, K. A1 - Wei, A. A1 - Tao, C. A1 - Huang, W. A1 - Zhao, Peng A1 - Wu, Dejian T1 - Iron dust explosion characteristics with small amount of nano-sized Fe2O3 and Fe3O4 particles N2 - Iron powder, as one of the most abundant metal fuels that can be used as recyclable carriers of clean energy, is a promising alternative to fossil fuels in a future low-carbon economy. It may pose a potential explosion hazard during the process of processing, storage, transport, and reduction/oxidation (redox). The explosion characteristics of iron dust in air were undertaken via a 20 L spherical explosion chamber with an emphasis on minimum explosion concentration (MEC) of iron dust. The alternative method of combustion duration time (tc) was used to determine MEC and compared with the standardized over pressure method. Two kinds of nano-sized iron oxides (Fe2O3 and Fe3O4) were used as inertants to determine the inhibition effect of different oxidation products. The iron dust explosion products with various shapes and sizes were found to be able to grow up 4–6 times of the iron dust for the first time. Adding small amount of Fe2O3 or Fe3O4 could reduce the explosion severity and sensitivity of iron dust. The MEC data determined by both methods were comparable. The addition of 5 % oxide has obvious inhibition effect under 1500 g/m3 concentration. With the increase of oxide concentration to 10 %, the inerting effect increases, and the MEC of iron dust increases more than 3 times. The increase of dust concentration will weaken the inerting effect. When the concentration increases from 500 g/m3 to 3000 g/m3, the weakening effect of 10 % Fe2O3 on the explosion pressure decreases from 38.45 % to 2.24 %, and 10 % Fe3O4 decreases from 46.21 % to 10.63 %. Unlike coal, biomass or aluminum dusts, the iron dust explosion was found to have a unique secondary acceleration of pressure rise rate for the first time. These results provide a fundamental basis to mitigate the iron dust explosion via solid inerting method without adding extra elements. KW - Iron dust KW - Iron oxides KW - MEC KW - Combustion duration time KW - Explosion products KW - Pressure rise rate PY - 2022 U6 - https://doi.org/10.1016/j.fuel.2022.124786 SN - 0016-2361 VL - 324, Part C SP - 1 EP - 13 PB - Elsevier Ltd. AN - OPUS4-55057 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wu, Dejian A1 - Tan, X. A1 - Wei, A. A1 - Duan, Q. A1 - Huang, W. A1 - Schmidt, Martin T1 - Ignition temperature and mechanism of carbonaceous dust clouds: The roles of volatile matter, CH4 addition, O2 mole fraction and diluent gas N2 - Minimum ignition temperature of dust clouds (MITC) was studied experimentally and theoretically in different atmospheres. Three carbonaceous dusts were tested in both air and O2/CO2 atmospheres with CH4 mole fraction from 0 to 2%. Results showed that the ignition risk of the three dusts significantly increases (decrease of MITC by ~100 ℃) with increasing XO2 from 21% to 50%, but significantly decreases replacing N2 in air with CO2. The inhibition effect of CO2 on MITCs could be diminished by increasing XO2 or adding CH4. The addition of small amount of CH4 has different effects on the MITCs of different dust samples, following the opposite order of volatile matter content: anthracite>bituminous coal>starch. Two modified steady-state ignition models, considering the density of mixture gas and dust cloud, XO2 and its diffusivity, were developed to interpret the experimental observations. The analysis revealed that the global heterogeneous ignition model suits well for the hybrid mixtures of anthracite or bituminous coal dusts. In contrast, the proposed global homogeneous ignition model was found to be only valid for the pure starch dust, and the extra CH4 addition could strongly affect the ignition process of starch, particularly in O2/CO2 atmospheres with higher XO2. KW - Dust explosions KW - Gas explosions KW - Minimum ignition temperature KW - Hybrid mixtures PY - 2021 U6 - https://doi.org/10.1016/j.jhazmat.2020.124189 SN - 0304-3894 SN - 1873-3336 VL - 405 SP - 1 EP - 10 PB - Elsevier CY - Amsterdam AN - OPUS4-53838 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wu, W. A1 - Wei, A. A1 - Huang, W. A1 - Zhao, Peng A1 - Schmidt, Martin A1 - Krause, Ulrich A1 - Wu, Dejian T1 - Experimental and theoretical study on the inhibition effect of CO2/N2 blends on the ignition behavior of carbonaceous dust clouds N2 - Gaseous inhibitors are used in many industries for the explosion prevention of combustible dusts, mitigating the potential hazard to humans, properties and environments. This work experimentally and theoretically studied the inerting effect of gaseous inhibitors on the ignition process of dust clouds in O2/N2/CO2 atmospheres, with an emphasis on the role of the CO2/N2 ratio. 10 different combustible carbonaceous dusts were selected, including grain dust, biomass dust and coal dust. Experimental results showed that the inhibition effect of CO2/N2 is closely related to the ignition mechanism of dust clouds. Specifically, a higher ratio of CO2/N2 yields a stronger inhibition effect on the ignition process of dust samples with relatively low volatile matter contents predominated by heterogeneous ignition. In addition, two novel steady-state ignition mechanism models were developed to interpret the experimental observations. Maxwell-Stefan equations were used to describe the diffusivity in the ternary O2/N2/CO2 gas mixtures. The analytical results were in good agreement with the experimental data of the minimum ignition temperature of dust cloud (MITC) in oxygen-lean atmospheres. The mechanism modelling can be used to estimate the critical ignition temperature of all carbonaceous dust clouds with a wide range of volatile matter content under different inert atmospheres, which will provide a reference for the explosion hazard assessment of dust posed by a hot surface in the process industries. KW - CO2/N2 ratio KW - Inerting effect KW - Volatile matter content KW - MITC KW - Mechanism model PY - 2021 U6 - https://doi.org/10.1016/j.psep.2021.07.005 SN - 0957-5820 VL - 153 SP - 1 EP - 10 PB - Elsevier B.V. AN - OPUS4-53662 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wu, Dejian A1 - Schmidt, Martin A1 - Tan, X. A1 - Zhao, P. A1 - Huang, W. A1 - Qian, X. T1 - Minimum ignition temperature of carbonaceous dust clouds in air with CH4/H-2/CO below the gas lower explosion limit N2 - Godbert-Greenwald furnace was used to investigate the minimum ignition temperature of dust clouds (MITC) in air with the presence of flammable gas which is lower than its lower explosion limit (LEL). Three flammable gases (CH4, H2 and CO) and three carbonaceous dusts (anthracite coal, bituminous coal and sweet potato starch) were tested. Results showed that all flammable gases have distinct effects on the MITC of the dust samples and volatile matter content of dust plays an important role during the ignition process. Specifically, the MITC of anthracite coal dust decreased from 610 °C to 560 °C, 580 °C and 570 °C with 3% CH4, 3% CO and 2.5% H2, respectively. Moreover, a heterogeneous ignition mechanism model was proposed to verify the equally global ignition characteristic between hybrid anthracite coal-CxHy mixture and bituminous coal. All three gases had an ignorable effect on the MITC of starch dust considering the experimental error. The presence of CO and H2 slightly promoted the ignition of bituminous coal dust, but the addition of CH4 showed a distinct concentration effect on the MITC of bituminous coal: the MITC decreased with 1% CH4 while increased with 2% and 3% CH4. This negative-effect of flammable gases at such low concentrations on ignition temperature of bituminous coal dusts was found for the first time. Furthermore, the presence of the 2nd flammable gas had a smaller effect on the MITC of dust samples with a higher volatile content, resulted from the competition of heterogeneous and homogeneous ignition mechanisms. KW - Dust explosions KW - Gas explosions KW - Minimum ignition temperature KW - Hybrid mixtures PY - 2020 U6 - https://doi.org/10.1016/j.fuel.2019.116811 SN - 0016-2361 VL - 264 SP - 116811 PB - Elsevier Ltd. AN - OPUS4-50856 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schmidt, Martin A1 - Wu, Dejian A1 - Zhao, P. A1 - Tan, X. A1 - Huang, W. A1 - Qianc, X. T1 - Minimum explosion concentrations of coal dusts with CH4/H2/CO below the gas lower explosion limit N2 - A 20-L spherical explosion chamber was used to investigate the explosion characteristics of dust clouds in air with the presence of flammable gas which is lower than its lower explosion limit (LEL). including minimum explosion concentration (MEC) of dust. Explosion pressure (Pex) and explosion pressure rise (dp/dt)ex). Two dust samples (anthracite coal, bituminous coal) and were three flammable gases (CH4, H2 and CO) were tested. Experimental results showed that the explosion of hybrid mixtures occurs when both dust and gas concentrations are lower than the LEL/MEC of the single substances. Meanwhile. all flammable gases with different volume fractions have distinct effects on the MEC. Pex and (dp/dt)ex of the dust samples. With the increase of the flammable gas concentration. either the Pex and (dp/dt)ex increase or the MEC decreases for all the hybrid mixtures of both two dust samples. At the same concentration of coal dusts. the addition of CH4 promotes higher explosion risks than the other two flammable gases. The distribution of (dp/dt)ex is quite different with the restricted area defined by empirical formulas. These results improve our understanding of the explosion behaviour and the explosion risk of hybrid dust-gas mixtures in air. KW - Dust explosions KW - Gas explosions KW - Minimum explosible concentration KW - Lower explosion limit KW - Hybrid mixtures PY - 2020 U6 - https://doi.org/10.1016/j.fuel.2019.116401 SN - 0032-5910 VL - 260 SP - UNSP 116401 PB - Elsevier Sci. Ltd. AN - OPUS4-49956 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -