TY - JOUR A1 - Häßler, Mai A1 - Häßler, Dustin A1 - Hothan, Sascha A1 - Krüger, Simone T1 - Fire tests of steel tension rod systems with intumescent coating N2 - Purpose – The purpose of this paper is to investigate the performance of intumescent coating on tension rod systems and their components. Steel tension rod systems consist of tension rods, fork end connectors and associated intersection or gusset plates. In case of fire, beside the tension rods themselves, the connection parts require appropriate fire protection. Intumescent fire protection coatings prevent a rapid heating of the steel and help secure the structural load-carrying capacity. Because the connection components of tension rod systems feature surface curvature and a complex geometry, high demand is placed on the intumescence and thermal protection performance of the coatings. Design/methodology/approach – In this paper, experimental studies were carried out for steel tension rod systems with intumescent coating. The examined aspects include the foaming and cracking behaviour, the influence of different dry film thicknesses, the heating rate of the steel connecting parts in comparison to the tension rods, and the mounting orientation of the tension rods together with their fork end connectors. Findings – The results show that a decrease in surface curvature and/or an increase inmass concentration of the steel components leads to a lower heating rate of the steel. Moreover, the performance of the intumescent coating on tension rod systems is influenced by themounting orientation of the steel components. Originality/value – The findings based on fire tests contribute to a better understanding of the intumescent coating performance on connection components of tension rod systems. This subject has not been extensively studied yet. KW - Steel KW - Fire test KW - Intumescent coating KW - Reactive fire protection system KW - Tension rod system PY - 2019 DO - https://doi.org/10.1108/JSFE-01-2019-0005 SN - 2040-2317 VL - 11 IS - 1 SP - 22 EP - 32 PB - Emerald Publishing Limited AN - OPUS4-48714 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fürst, Richard A1 - Häßler, Dustin A1 - Peter, A. A1 - Rohleder, R. A1 - Hothan, Sascha T1 - European test standard intumescent coatings applied to steel tension bars with solid section N2 - Intumescent coatings are used in civil engineering to improve the fire resistance of steel constructions. Due to the thin coating thickness and the profile-following application, the architectural appearance of the steel structure can be preserved. EN 13381-8 provides regulations to determine the contribution to the fire resistance of intumescent coatings applied to steel beams and columns. The scope of this standard excludes tension members and steel members with solid sections. For products that have already been successfully tested and assessed on beams and columns, EN 13381-10 offers the possibility based on unloaded fire tests to extend the scope of application of intumescent coatings to tension bars with solid sections. This approach contradicts the national safety level in Germany, where mechanically loaded testing is mandatory. Therefore, a new part of the test standard series EN 13381 is currently developed to enable the application of intumescent coatings on steel tension bars with solid section based on mechanically loaded fire tests. BAM has already carried out numerous fire tests on loaded steel tension members with intumescent coatings. Currently, in the BAM research project FIRESTEMIC, the influence of the steel bar orientation and the profile type on the thermal performance of intumescent coatings are investigated. Both questions concerning the thermal protection ability of intumescent coatings were analysed based on three different test sets, which were carried out in the tension furnace (Fig. 1a). The fire exposure corresponds to the standard temperature-time curve according to EN 1363-1. This paper summarises the main findings from the fire tests conducted in the FIRESTEMIC project. The results serve as an experimental background for the proposal of the new standard. Regarding the bar orientation, a new test setup was developed and proposed for the new standard. The two tested commercial water-based intumescent coatings with applied dry film thickness from 1.5 mm to 2.5 mm showed only a slight dependence on the bar orientation. In terms of the steel profile type, circular and rectangular solid sections with identical section factor and applied dry film thickness were tested. It was observed that the circular solid bars with diameter 30 mm heat up faster compared to the solid rectangular bars with dimension 30×30 mm (Fig. 1b). Also at larger steel bars, i.e. diameter 40 mm and dimension 40×40 mm, the same trend occurred. Thus, it is recommended for the new test standard to allow a transfer of the test results from circular to rectangular solid sections. In addition, the paper will describe and explain the test and assessment procedure proposed for the newly developed standard. T2 - 8th Symposium Structural Fire Engineering CY - Brunswick, Germany DA - 13.09.2022 KW - Fire test KW - Steel KW - Tension member KW - Intumescent coating KW - Test standard PY - 2022 SP - 1 EP - 14 PB - TU Braunschweig CY - Braunschweig AN - OPUS4-55703 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Häßler, Dustin A1 - Becker, Andreas A1 - Fürst, Richard A1 - Hothan, Sascha ED - Simões da Silva, Luís ED - Vila Real, Paulo ED - Santiago, Aldina ED - Craveiro, Hélder ED - Laim, Luís T1 - Fire resistance testing of steel tension members with hollow section protected by intumescent coating N2 - This book presents the proceedings of the Thirteenth International Conference Structures in Fire. The conference took place at the Department of Civil Engineering, University of Coimbra, Portugal, from 19 to 21 June 2024, under the auspices of the SIF movement. Structural fire safety is a crucial aspect of the design of buildings and infrastructures. Significant advances in research have increased the knowledge on this topic. However, until the 1990s, there were few forums for structural fire engineers to exchange ideas and share research findings. SIF (Structures in Fire) specialised workshop series was conceived in the late 1990s and the “First International SIF Workshop” was held in Copenhagen, Denmark in 2000, followed by workshops in Christchurch, New Zealand (2002), Ottawa, Canada (2004) and Aveiro, Portugal (2006). The series of workshops evolved into conferences and the 2008 event in Singapore was the fifth International Conference on Structures in Fire. This was followed by events in East Lansing, USA (2010), Zurich, Switzerland (2012), Shanghai, China (2014), New Jersey, USA (2016), Belfast, UK (2018), Brisbane, Australia (2020) and Hong Kong, China (2022). Information about previous conferences, including complete proceedings, can be found at www.structuresinfire.com. The main mission of SIF conferences is to provide an opportunity for researchers and engineers from the global structural fire engineering community to participate, share and discuss the recent findings, innovations and developments with their peers in an open and international forum. Following the great success of the previous International Conferences, the University of Coimbra was selected to host the 13th International Conference on Structures in Fire. As with most of the recent conferences, the number of papers submitted far exceeds the number of papers that can be accommodated in the three-day programme, even with two parallel sessions. SIF 2024 received 249 abstracts before the deadline and accepted 172 abstracts after the review process by at least three reviewers from the scientific committee. These proceedings represent 132 full papers, collectively representing the state of the art in fundamental knowledge and practical application of structures in fire. Forty-two countries from around the globe have contributed to them. The papers are grouped into the following research topics: Applications of Structural Fire Engineering, Composite Structures in Fire, Concrete Structures in Fire, Timber Structures in Fire, Masonry Structures in Fire, Steel Structures in Fire, Experimental Research of Structures in Fire, Numerical Modelling of Structures in Fire, Other Topics Related to Structures in Fire. Finally, the Organizing Committee would like to thank the continuous support from the SIF Steering Committee chaired by Prof Jean-Marc Franssen. We also would like to thank to the Scientific Committee chaired by Prof Paulo Vila Real, the authors and all the supporting staff (and volunteer team) from the Institute for Sustainability and Innovation in Structural Engineering (ISISE) in Coimbra, for making SIF 2024 a successful conference. DA - 19.06.2024 KW - Fire resistance KW - Fire test KW - Intumescent coating KW - Steel KW - Tension member PY - 2024 DO - https://doi.org/10.30779/cmm_SIF24 SP - 1173 EP - 1183 PB - CMM – Portuguese Steelwork Association AN - OPUS4-60815 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fürst, Richard A1 - Häßler, Dustin A1 - Stelzner, Ludwig A1 - Hothan, Sascha T1 - Development of an in situ test method to assess the fire resistance of steel members with applied intumes-cent coating N2 - Intumescent coatings are commonly used in civil engineering to improve the fire resistance of steel constructions. Exposed to fire, the intumescent coating reacts and forms a thermal protective char around the steel member. Thus, the heating of the steel is delayed, and a higher fire resistance can be achieved. Generally, the scope of application and the durability of intumescent coatings are described in national approvals or European Technical Assessment (ETA) documents. Due to environmental conditions, intumescent coatings are subjected to ageing effects, which can reduce their durability and thermal protection performance. Available in situ methods to investigate the performance of applied intumescent coatings, such as visual inspection, flame exposure testing, adhesive tensile tests or chemical analysis, are not fully conclusive. Therefore, in the civil engineering practice, there is an increasing demand to verify the fire resistance of existing steel structures with applied intumescent coatings necessary in several cases, e.g., the working life is exceeded, the visual appearance of the intumescent coating changed or the information about the applied product is missing. The research presented in the paper shows the progress of the ongoing research project "INSIST" at BAM [1], where a new in situ method is being developed to assess the actual fire resistance of existing steel structures with applied intumescent coating. The investigation is based on a development of the in situ test procedure and a mobile prototype furnace. T2 - 10th Symposium Structural Fire Engineering CY - Braunschweig, Germany DA - 24.09.2024 KW - In situ KW - Intumescent coating KW - Steel structures KW - Test procedure PY - 2024 SP - 1 EP - 15 AN - OPUS4-61275 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fürst, Richard A1 - Häßler, Dustin A1 - Stelzner, Ludwig A1 - Hothan, Sascha T1 - In situ test procedure to determine the fire resistance of exisiting steel structures with aged intumescent coating N2 - Intumescent coatings are commonly used in civil engineering to increase the fire resistance of steel structures. In case of a fire, the intumescent coating reacts and forms a thermally protective char around the steel member. Thus, the heating of the steel is significantly delayed, and as a result, a higher fire resistance can be achieved. Throughout the working life, intumescent coatings are aged by climatic factors. To predict durability for several years, the behaviour of the intumescent coatings is extrapolated based on accelerated artificial ageing. The established German and European assessment procedures to test and predict durability assume a working life of at least 10 years. For an extended period, additional evidence is required; yet the procedure and specifications to justify this are not described. Available in situ methods to assess the thermal performance of intumescent coatings are currently limited in their information content. Therefore, BAM is conducting a research project to develop a minimally invasive in situ test procedure to determine the fire resistance of existing steel structures with applied intumescent coating. The paper will describe the test setup, the developed prototype furnace, and the results of the performed test programme with uncoated and coated steel specimens. Based on this, recommendations for the test procedure are given. T2 - Structures in Fire 2024 CY - Coimbra, Portugal DA - 19.06.2024 KW - In situ KW - Intumescent coating KW - Steel structures KW - Test procedure PY - 2024 SN - 978-989-35292-2-5 DO - https://doi.org/10.30779/cmm_SIF24 SP - 1217 EP - 1228 AN - OPUS4-61258 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fürst, Richard A1 - Häßler, Dustin A1 - Stelzner, Ludwig A1 - Hothan, Sascha T1 - Development of an in situ test method to assess the fire resistance of steel members with applied intumescent coating N2 - Intumescent coatings are commonly used in civil engineering to improve the fire resistance of steel constructions. Exposed to fire, the intumescent coating reacts and forms a thermal protective char around the steel member. Thus, the heating of the steel is delayed, and a higher fire resistance can be achieved. Generally, the scope of application and the durability of intumescent coatings are described in national approvals or European Technical Assessment (ETA) documents. Due to environmental conditions, intumescent coatings are subjected to ageing effects, which can reduce their durability and thermal protection performance. Available in situ methods to investigate the performance of applied intumescent coatings, such as visual inspection, flame exposure testing, adhesive tensile tests or chemical analysis, are not fully conclusive. Therefore, in the civil engineering practice, there is an increasing demand to verify the fire resistance of existing steel structures with applied intumescent coatings necessary in several cases, e.g., the working life is exceeded, the visual appearance of the intumescent coating changed or the information about the applied product is missing. The research presented in the paper shows the progress of the ongoing research project "INSIST" at BAM, where a new in situ method is being developed to assess the actual fire resistance of existing steel structures with applied intumescent coating. The investigation is based on a development of the in situ test procedure and a mobile prototype furnace. T2 - 10th Symposium Structural Fire Engineering – TU Braunschweig 2024 CY - Braunschweig, Germany DA - 24.09.2024 KW - In situ KW - Intumescent coating KW - Steel structures KW - Test procedure PY - 2024 AN - OPUS4-61261 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fürst, Richard A1 - Häßler, Dustin A1 - Stelzner, Ludwig A1 - Hothan, Sascha T1 - In situ test procedure to determine the fire resistance of existing steel structures with aged intumescent coating N2 - BAM is conducting a research project to develop a minimally invasive in situ test procedure to determine the fire resistance of existing steel structures with applied intumescent coating. In presentation and submitted paper is describe the test setup, the developed prototype furnace, and the results of the performed test programme with uncoated and coated steel specimens. Based on this, recommendations for the test procedure are given. T2 - Structures in Fire 2024 CY - Coimbra, Portugal DA - 19.06.2024 KW - In situ KW - Intumescent coating KW - Steel structures KW - Test procedure PY - 2024 AN - OPUS4-61257 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -