TY - JOUR A1 - Nohr, Michael A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Richter, Matthias A1 - Lorenz, W. T1 - Development of a multi-VOC reference material for quality assurance in materials emission testing N2 - Emission test chamber measurement is necessary to proof building materials as sources of volatile organic compounds (VOCs). The results of such measurements are used to evaluate materials and label them according to their potential to emit harmful substances, polluting indoor air. If only labelled materials were installed indoors, this would improve indoor air quality and prevent negative impacts on human health. Because of the complex testing procedure, reference materials for the quality assurance are mandatory. Currently, there is a lack of such materials because most building products show a broad variation of emissions even within one batch. A previous study indicates lacquers, mixed with volatile organic pollutants, as reproducible emission source for a wide range of substances. In the present study, the curing of the lacquer-VOC mixture inside micro-chambers was optimised. Therefore, the humidity and the chamber flow were varied. Typical indoor air pollutants with a wide range of volatilities, for example, styrene, n-hexadecane, dimethyl and dibutyl phthalate were selected. It turned out that, under optimised curing parameters inside the micro-chamber, their emission can be reproduced with variations of less than 10 %. With this, a next important step towards a reference material for emission testing was achieved. KW - Reference material KW - Emission KW - Emission test chamber KW - Micro-chamber KW - VOC PY - 2015 DO - https://doi.org/10.1007/s00216-014-8387-2 SN - 1618-2642 SN - 1618-2650 VL - 407 IS - 11 SP - 3231 EP - 3237 PB - Springer CY - Berlin AN - OPUS4-32404 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Design of Reference Materials for Proficiency Tests for Measurements in Emission Test Chambers T1 - Entwicklung von Referenzmaterialien für Leistungstests bei Emissionskammermessungen N2 - Emission testing of products is currently a rapidly increasing field of measurement activity. Labelling procedures for construction products are based on such emission test chamber measurements and hence measurement performance should be verified. A suited procedure for this purpose is the testing of one unique homogenous material in different laboratories within a Round Robin Test (RRT). Therefore, it is useful to have a reference material which can be used within inter-laboratory studies or as part of the quality management system to ensure comparable results. Any commercially available product on the market can be used as reference material, provided it is thoroughly characterised. However, these materials often emit only a few and material specific VOCs and appropriate homogeneity is not given. Therefore, alternative materials should be found. Several approaches on the development of reproducibly emitting materials have been published. These have in common only to emit a single VOC – toluene. Two further research studies carried out by BAM aimed to develop reference material for emissions testing containing one or more VOC in a single material. The first approach was a doped lacquer with Volatile and Semi-Volatile Organic Compounds (VOC/SVOC) and the second was Thermoplastic Polyurethane (TPU) or a Squalane/Paraffin mixture. Currently, the second approach is not at a level that it could be tested within a RRT. Important requirements for the production of a reference material were repeatability (homogeneity), reproducibility, long-term stability in terms of compound release and transport stability. The emission rates should be high enough to obtain well measurable chamber air concentrations at standardised test conditions. The lacquer samples were prepared by weighing portions of a water-based lacquer to which defined amounts of the pure analytes were added. Defined amounts of the lacquer mixture were filled into Petri dishes and cured under standard conditions (23 °C and 50% relative humidity). Reproducible emissions were obtained when the storage time of the cured material was not longer than four weeks. The concentrations were analyzed 7 days after loading of the material into the chamber. Two RRT were conducted by use of the lacquer system. Here, the laboratories had to identify and also to quantify the compounds. The relative standard deviations obtained were typical for such a kind of test. More than 50 participants reported results. N2 - Die Untersuchung von Produkten auf deren Emissionseigenschaften ist ein aktuell wachsender Aufgabenbereich für Messinstitute. Label werden für Bauprodukte auf Basis von Emissionskammermessungen vergeben, weshalb die dabei eingesetzten Messmethoden überprüft werden sollten. Ein Ringversuch (RV), bei dem ein homogenes Material von verschiedenen Laboratorien parallel untersucht wird, ist ein geeignetes Verfahren dafür. Für einen solchen Ringversuch aber auch generell für die laborinterne Qualitätssicherung ist es sehr hilfreich ein Referenzmaterial zu haben, um gut vergleichbare Ergebnisse zu erhalten. Generell kann jedes kommerziell erhältliche Produkt als Referenzmaterial verwendet werden, wenn es gut charakterisiert ist. Allerdings emittieren die meisten Produkte nur wenige VOC und diese sind typischerweise sehr materialspezifisch. Die Homogenität der Materialien ist nicht immer gegeben, so ist es besser, nach alternativen Materialien zu suchen. Es sind schon einige Veröffentlichungen zu reproduzierbar emittierenden Materialien verfügbar. Diese enthalten bislang zumeist nur ein einzelnes VOC – Toluol. Im Rahmen von zwei Forschungsvorhaben arbeitet die BAM an der Entwicklung von Referenzmaterialien für Emissionskammer-Untersuchungen, die einzelne VOC oder VOC-Mischungen emittieren. Der erste Ansatz war die Dotierung eines kommerziellen Lackes mit einer VOC/SVOC-Mischung, weitere Untersuchungen werden mit Thermo¬plastischem Polyurethan (TPU) sowie einer Squalan/Paraffin-Mischung durchgeführt. Da mit dem zweiten Ansatz noch Tests laufen, ist damit noch kein RV durchgeführt worden. Wichtige Anforderungen an ein Referenzmaterial sind die Wiederholbarkeit (Homogenität), Reprodu-zierbarkeit und Langzeitstabilität in Bezug auf die VOC-Abgabe und die Transportstabilität. Die Emissionsraten sollten hoch genug sein, um gut messbare Kammerluft-Konzentrationen bei Standardbedingungen zu erhalten. In einen wasserbasierten Lack wurde eine VOC/SVOC-Mischung zugegeben und nach der Durchmischung wurden davon einzelne Portionen in Petrischalen abgefüllt. Diese Schalen wurden unter Standardbedingungen (23 °C und 50% relative Luftfeuchtigkeit) getrocknet. Reproduzierbare Emissionen wurden erhalten, wenn die Lagerzeit ca. vier Wochen nicht überschritten wurde. Die Konzentrationen wurden sieben Tage nach der Beladung der Kammer bestimmt. Zwei RV wurden mit einem wie oben beschriebenen Lacksystem durchgeführt. Es nahmen ca. 50 Labore teil, diese mussten die Zielsubstanzen sowohl identifizieren als auch quantifizieren. Die gefundenen Mittelwerte und Standardabweichungen lagen jeweils im zu erwartenden Bereich für solch einen RV. T2 - Odour and Emission of Plastic Materials CY - Kassel, Germany DA - 21.03.2017 KW - Ringversuch KW - Round robin test KW - Emissionskammer KW - Emission test chamber KW - Referenzmaterial KW - Reference material PY - 2017 AN - OPUS4-40299 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mull, Birte A1 - Sauerwald, T. A1 - Richter, Matthias A1 - Horn, Wolfgang A1 - Brödner, Doris A1 - Schultealbert, C. T1 - Development of a reproducibly emitting reference material for volatile organic compounds N2 - The aim of this study is the development of a reproducibly emitting reference material for volatile organic compounds (VOC). The first part of the work was carried out with styrene, for which supporting materials were successfully selected, doped and analyzed in test chambers. T2 - Indoor Air 2016 The 14th international conference of Indoor Air Quality and Climate CY - Ghent, Belgium DA - 03.07.2016 KW - Quality control KW - Emission test chamber KW - Indoor air KW - Quality assurance PY - 2016 SN - 978-0-9846855-5-4 AN - OPUS4-36849 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Schultealbart, Caroline T1 - Reference materials for round robin tests for emission test chambers – a review N2 - Since some volatile organic compounds (VOC) are dangerous to human health whilst others cause harm to the environment by influencing the oxidative capacity of the atmosphere, the overall aim of the KEY-VOCs project is to improve the measurement infrastructure for Key Volatile Organic Compounds in indoor and outdoor air. This is done by providing traceable and comparable reference gas standards and by validating new measurement systems in support to the air monitoring networks. T2 - Metrologie for indoor air quality CY - Berlin, Germany DA - 29.06.2017 KW - Emission test chamber KW - QA/QC KW - Reference material KW - Round robin test KW - VOC PY - 2017 AN - OPUS4-41938 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mull, Birte A1 - Sauerwald, T. A1 - Schultealbert, C. A1 - Horn, Wolfgang A1 - Brödner, Doris A1 - Richter, Matthias T1 - Reproducibly emitting reference materials for volatile and semi-volatile organic compounds—using finite element modeling for emission predictions N2 - Recent research into emissions of (semi-)volatile organic compounds [(S)VOC] from solid materials has focused on the development of suitable reference materials for quality assurance/quality control of emission test chamber measurements, which fulfill requirements such as homogenous and reproducible (S)VOC release. The approach of this study was to find a method for preparation of a material with predictable (S)VOC emission rates. AVOC (styrene) and an SVOC (2,6-diisopropylnaphthalene, DIPN), loaded into either vacuum grease or a 1:1 mixture of paraffin/squalane, have been tested. For the prediction of the emission rates, a model using the finite element method (FEM) was created to simulate the (S)VOC emission profiles. Theoretical and experimental results obtained in a Micro-Chamber/Thermal Extractor (μ-CTE™) and in 24 L emission test chamber measurements were in good agreement. Further properties were investigated concerning the material applicability, such as shelf life and inter-laboratory comparability. The maximum relative standard deviation in the inter-laboratory study was found to be 20%. KW - Emitting reference material KW - Emission test chamber KW - Micro-chamber KW - FEM model PY - 2017 DO - https://doi.org/10.1007/s11869-017-0508-6 SN - 1873-9318 SN - 1873-9326 VL - 10 IS - 10 SP - 1237 EP - 1246 PB - Springer Science+Business Media B.V. AN - OPUS4-41951 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Kasche, J. A1 - Bitter, F. A1 - Müller, D. A1 - Müller, B. T1 - Environmental and Health Provisions for Building Products - Identification and evaluation of VOC emissions and odour exposure (Research Report 202 62 320 / UBA-FB 001002) N2 - In this study 50 construction products were tested in emission test chambers according to the requirements of the AgBB-scheme: 7 acrylic and 6 silicone sealants, 6 paste-like synthetic resin plasters, 13 wood based products, 4 adhesives, 5 lacquers, 6 wall paints and 3 further construction products. VOC and odour emissions were tested on the 1st, 3rd, 10th, and 28th day. In addition to the VOC-measurements, a test procedure was developed to evaluate odour emission of construction products.This test is planned to be implemented into the AgBB-Scheme. A direct evaluation by a sensory panel in the emission test chamber was not possible. So the odour samples were collected in 300- litre tedlar bags which were evaluated later. Odour intensity of the samples was compared with different acetone concentrations. Within this study an interlaboratory comparison was conducted using the newly developed odour test method. Additionally, VVOC emissions, detection of carcinogenic compounds, repeatability of emission test chamber tests, and other issues are presented. This project has shown that construction products can be evaluated in accordance with the AgBB scheme. A sensory evaluation is intended to be introduced in the AgBB scheme. A method for this evaluation is described in this study. The test procedure should be enhanced and validated for practical utilisation. KW - Building products KW - Emissions KW - Odour KW - AgBB-Scheme KW - Chamber tests KW - Interlaboratory study KW - Construction products KW - Emission test chamber KW - Odour evaluation KW - VOC KW - VVOC KW - SVOC KW - Thermal desorption KW - GC/MS KW - GC-ODP KW - Odour standard of comparison KW - Gas sensor KW - Acrylic and silicone sealant KW - Wood-based product KW - Paints KW - Lacquers KW - Interlaboratory comparison PY - 2007 UR - http://www.umweltbundesamt.de/publikationen/environmental-health-provisions-for-building SN - 1862-4804 SN - 0722-186X IS - 21 SP - 1 EP - 381 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-15931 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Wiegner, Katharina T1 - Inter-laboratory study to check the performance ot test chamber measurements for product emission testing N2 - The labelling of construction products or building materials as “low-emitting” is based on measurements using third-party emission test chambers. Unfortunately there is no method to validate the performance of such test chamber measurements. This might give a Variation of results when testing one material at different laboratories. Therefore it is necessary to hold round robin tests as part of the quality management System to ensure comparable results. A research project financed by the Federal Environmental Agency focused on the development of an external quality management System for the detection of relevant Chemical compounds from products and in ambient air. The project was structured in four phases (Horn et al., 2009 and 2011; Wilke et al., 2009a) This paper shows results of the fourth phase of the project, which was an inter-laboratory study for VOC-emission testing by means of emission test chambers. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Emission test chamber KW - Product emission testing KW - VOC-Emission KW - Round robin test PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23884 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Müller, B. A1 - Panasková, J. A1 - Danielak, M. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Müller, D. T1 - Sensory-based evaluation of building product emissions - Integration into the Blue Angel award criteria and assessment scheme of the Committee for Health Evaluation of Building Products (UBA-FB 001500 / Förder-Kennz. 370762300) N2 - Emissions from building products can considerably impair the quality of indoor air. The AgBB scheme is employed to evaluate the emissions of volatile organic compounds (VOC) from building products. The hygienic evaluation according to the AgBB scheme requires product-specific measuring procedures. These are available for a range of products. They have been validated in co-operation with several research and testing institutes and have been included in the criteria for awarding the Blue Angel ecolabel. The evaluation is, however, stricter and generally has lower limits. VOC emissions and odours can cause health problems so testing using sensors is an important element in the evaluation of building products and has – for reasons of precaution – been set down in the AgBB scheme. The main goal of the project was to derive a method of evaluation using sensors and limits for awarding the Blue Angel and for the AgBB scheme. Based on the research conducted (see Chapter 5 Results and Discussion), perceived intensity and hedonics were suggested as a suitable Evaluation method. The derivation of limits for the evaluation using sensors on the 28th day was effected in the present study through the additional questioning of the test subjects on the reasonability of a sample. For the Blue Angel, there could be different limits of perceived intensity and hedonics for each group of products. A preliminary suggestion for possible limits – for all product groups – is a perceived intensity of 7 pi (5 pi + 2 pi as confidence coefficient, Chapter 5.1.5) and -1 (0+/-0.8, rounded to -1) for the hedonic value. KW - Labelsysteme KW - VOC KW - Geruch KW - Geruchstest KW - Emissionsmessungen KW - Building product KW - Directive KW - Health care KW - Pollutant KW - Test method KW - Hydrocarbon KW - Testing using sensors KW - Emission KW - Emission test chamber KW - Odour KW - AgBB scheme KW - Health assessment KW - Assessment procedure KW - Volatile organic compounds KW - Very volatile organic compounds KW - VVOC KW - Semi volatile organic compounds KW - SVOC KW - Thermal desorption KW - GC/MS KW - GC-ODP KW - Odour standard of comparison KW - Floor coverings KW - Coverings KW - Blue Angel KW - Odour evaluation KW - Acceptability KW - Perceived intensity KW - Hedonic KW - Reasonability KW - Standardization KW - Environmental sign KW - Volatile emission KW - Product labelling PY - 2011 UR - http://www.umweltbundesamt.de/publikationen/sensory-based-evaluation-of-building-product SN - 1862-4804 IS - 61 SP - 1-133, Annex 1-109 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-25200 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Kalus, Sabine A1 - Jann, Oliver T1 - Different possibilities for the statistical evaluation of round robin tests for volatile organic compounds in emission test chambers N2 - Emission testing of products is currently a rapidly increasing field of activity. The amounts of volatile organic compounds (VOC) which emit from products in emission test Chambers are used to evaluate these products. Typically labelling procedures for construction products are based on emission test chamber measurements. This performance should be verified. Possibly this can be performed due to testing of one material at different laboratories within a round robin test. Therefore it is necessary that a reference material exists which can be used for such round robin tests or as part of the quality management System to ensure comparable results. The different Statistical evaluation possibilities of a round robin test with a constant reference material for VOCs (volatile organic compounds) in emission test Chambers are the main focus of the presented paper. T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 08.07.2012 KW - Reference material KW - Round robin test KW - Emission test chamber KW - VOC-emission KW - Product emission testing PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 2 (8B.6) AN - OPUS4-27526 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Wilke, Olaf T1 - Suitability of small environmental chambers to test the emission of biocides from treated materials into the air N2 - Biocides are used to protect materials that might be damaged by fungal, microbial or insect activity. The aim of this study is to develop a method for the measurement of these organic compounds, which generally have low or moderate vapor pressures. The biocides considered in this study are permethrin, dichlofluanid, tolylfluanid, iodpropinylbutylcarbamat, octylisothiazolinone, tebuconazole and propiconazole. The emission from two commercial products (plastic foil, wool carpet) containing biocides and of seven types of biocidal formulations applied to wood or clay tiles were investigated in 20-l glass emission test chambers. Each chamber test was performed over a period of 100–200 days, and one investigation was conducted over several years. Compared to volatile organic compounds, low-volatility compounds show totally different emission curves in chamber tests; maximal emission values may be reached in days or weeks. A period of 3 months is sometimes necessary for the determination of area-specific emission rates (SERa's). The SERa's (?g m-2 h-1) from biocide-containing products were determined for permethrin (0.006), propiconazole (0.3), dichlofluanid (2.0), tolylfluanid (1.0), octylisothiazolinone (2.5) and iodpropinylbutylcarbamat (2). In most cases, the SERa stayed at its maximum value or declined slowly over the test period. Additionally, a chamber test begun in 1994 with a piece of wood treated with a typical mixture of biocides dissolved in a technical solvent was continued. SERa's (?g m-2 h-1) for dichlofluanid (0.20), tebuconazole (0.49) and permethrin (0.08) remained detectable after the period of nearly 9 years during which the sample remained continuously in the chamber. This test proved the very slow decrease of emission of low-volatility compounds like permethrin and tebuconazole. KW - Indoor air KW - Biocides KW - Emission test chamber KW - SVOC PY - 2003 DO - https://doi.org/10.1016/j.atmosenv.2003.09.024 SN - 0004-6981 SN - 1352-2310 VL - 37 IS - 39-40 SP - 5477 EP - 5483 PB - Elsevier CY - Amsterdam AN - OPUS4-2676 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -