TY - JOUR A1 - Dietrich, Paul A1 - Hennig, Andreas A1 - Holzweber, Markus A1 - Thiele, T. A1 - Borcherding, H. A1 - Lippitz, Andreas A1 - Schedler, U. A1 - Resch-Genger, Ute A1 - Unger, Wolfgang T1 - Surface analytical study of poly(acrylic acid)-grafted microparticles (beads): characterization, chemical derivatization, and quantification of surface carboxyl groups N2 - We report a surface analytical study of poly(methyl methacrylate) (PMMA) microparticles (beads) with a grafted shell of poly(acrylic acid) (PAA) with thicknesses up to 4 nm using scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectrometry (ToF-SIMS), and near-edge X-ray adsorption fine structure (NEXAFS) spectroscopy. These polymer microparticles were analyzed before and after reaction of the surface carboxyl (CO2H) groups with 2,2,2-trifluoroethylamine (TFEA) to gain a better understanding of methods with use of covalently bound probe molecules for surface group analysis. The results obtained with chemical derivatization XPS using TFEA are discussed in terms of surface quantification of reactive CO2H groups on these PAA-coated microparticles. A labeling yield of about 50% was found for TFEA-derivatized particles with amounts of surface-grafted CO2H groups of 99 µmol/g or more, which is consistent with predicted reaction yields for homogeneously dispersed PAA hydrogels. KW - Polymer microparticles KW - Poly(acrylic acid)-grafted microparticles KW - Beads KW - XPS KW - SEM KW - NEXAFS KW - Surface analysis KW - Fluorine labeling PY - 2014 U6 - https://doi.org/10.1021/jp505519g SN - 1932-7447 SN - 1089-5639 VL - 118 IS - 35 SP - 20393 EP - 20404 PB - Soc. CY - Washington, DC AN - OPUS4-31326 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Holzweber, Markus A1 - Lippitz, Andreas A1 - Krüger, K. A1 - Jankowski, J. A1 - Unger, Wolfgang T1 - Surface characterization of dialyzer polymer membranes by imaging ToF-SIMS and quantitative XPS line scans N2 - The surfaces of polymeric dialyzer membranes consisting of polysulfone and polyvinylpyrrolidone were investigated regarding the lateral distribution and quantitative surface composition using time-of-flight secondary-ion-mass-spectrometry and x-ray photoelectron spectroscopy. Knowledge of the distribution and composition on the outer surface region is of utmost importance for understanding the biocompatibility of such dialyzer membranes. Both flat membranes and hollow fiber membranes were studied. KW - Tof SIMS KW - XPS KW - Dialyzer membrane KW - Surface analysis KW - Polymer PY - 2015 U6 - https://doi.org/10.1116/1.4907937 SN - 1934-8630 SN - 1559-4106 VL - 10 IS - 1 SP - 019011-1 EP - 019011-7 PB - AVS CY - New York, NY, USA AN - OPUS4-32740 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -