TY - JOUR A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas T1 - A comfortable procedure for correcting X-ray detector backlight JF - Journal of physics / Conference series N2 - A novel approach is suggested to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background signals 'backlighting' of 2D X-ray detectors. Depending on the detector geometry the mechanism may be different. Either based on the optical scattering of the fluorescent screen materials into the optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beer's law in single projections (radiographs) as a function of the detector area coverage and the magnitude of the attenuation. The absorption of multiple metal sheets is investigated by monochromatic synchrotron radiation, thus excluding beam hardening. The proposed correction procedure simply requires the individual subtraction of one and the same fraction of the primary and transmitted mean intensity, as a constant (non-local) scattering mechanism is assumed. KW - X-ray detector backlighting KW - Radiography KW - Fluorescent screen KW - Diffuse background KW - Computed tomography PY - 2013 DO - https://doi.org/10.1088/1742-6596/425/19/192015 SN - 1742-6588 SN - 1742-6596 VL - 425 IS - 19 SP - 192015-1 EP - 192015-4 PB - IOP Publ. CY - Bristol, UK AN - OPUS4-28262 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas A1 - Müller, Bernd R. T1 - Numerical correction of X-ray detector backlighting JF - International journal of materials research N2 - A novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background signals ('backlighting') of 2D X-ray detectors is suggested. Depending on the detector geometry the mechanism may be different, either based on the optical scattering by the fluorescent screen materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert–Beer's law in single projections (radiographs). When used as input data for computed tomography these violations are directly observed via modulation of the projected mass as a function of the rotation phase and the sample’s aspect ratio (dynamics). The magnitude of the diffuse background signal depends on the detector area covered by the projected sample. They are more pronounced the smaller the shadowed area and the stronger the total attenuation. This implies that the reconstruction suffers from additional anisotropic artifacts caused by elongated sample structures. This issue is studied simply by absorption of flat plates in a conventional laboratory radiography set-up and at a synchrotron radiation facility. In the latter case beam hardening artifacts can be excluded due to the monochromatic radiation. The proposed correction procedure requires simple integral intensity offsets as a constant (non-local) light scattering mechanism is assumed. KW - Detector backlighting KW - X-ray detector scattering KW - Fluorescent screen KW - Diffuse background KW - Computed tomography PY - 2012 DO - https://doi.org/10.3139/146.110659 SN - 1862-5282 VL - 103 IS - 2 SP - 174 EP - 178 PB - Carl Hanser CY - München AN - OPUS4-25553 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas ED - Kastner, J. T1 - A comfortable procedure for correcting X-ray detector backlight T2 - Conference on industrial computed tomography (Proceedings) T2 - Conference on industrial computed tomography CY - Wels, Austria DA - 2012-09-19 KW - X-ray detector backlighting KW - Radiography KW - Fluorescent screen KW - Diffuse background KW - Computed tomography PY - 2012 SN - 978-3-8440-1281-1 SN - 1610-4773 SP - 151 EP - 157 PB - Shaker CY - Aachen AN - OPUS4-26768 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. T1 - Straightforward correction of X-ray detector backlighting T2 - 18th WCNDT - World conference on nondestructive testing (Proceedings) N2 - A novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background signals ('backlighting') of 2D X-ray detectors is suggested. Depending on the detector geometry the mechanism may be different, either based on the optical scattering of the fluorescent screen materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beer’s law in single projections (radiographs) as function of the detector area coverage and the magnitude of the attenuation. The absorption of multiple metal sheets is investigated by monochromatic synchrotron radiation, thus excluding beam hardening. The proposed correction procedure simply requires the individual subtraction of one and the same fraction of the primary and transmitted mean intensity, as a constant (non-local) scattering mechanism is assumed. T2 - 18th WCNDT - World conference on nondestructive testing CY - Durban, South Africa DA - 2012-04-16 KW - X-ray detector backlighting KW - Radiography KW - Fluorescent screen KW - Diffuse background KW - Computed tomography PY - 2012 UR - http://www.ndt.net/article/wcndt2012/papers/205_wcndtfinal00205.pdf SN - 978-0-620-52872-6 SP - 1 EP - 8(?) AN - OPUS4-25835 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -