TY - CONF A1 - Helmerich, Rosemarie A1 - Milmann, Boris A1 - Wöstmann, Jens T1 - Bond durability of CFRP-laminates on concrete bridges N2 - Trans-European corridors for transport of people and goods require strengthening of bridges to carry increased axle loads in terms of absolute axle loads and of their frequency. Most of the bridges along highways are reinforced or prestressed concrete bridges. Since the late 1990s, CFRP laminates have been applied to box girder and T-beam bridges to increase the overall capacity. Although regular inspections are carried out, no special method was available to test the bond condition of CFRP laminates after being in Service for more than ten years. The German Center of Competence in Civil Engineering is aware of this need and funded a research project to investigate the bond condition by means of advanced non-destructive testing (NDT). T2 - 31st Danubia-Adria Symposium on advances in experimental mechanics CY - Kempten, Germany DA - 24.09.2014 KW - Concrete bridges KW - Strengthening KW - Non-destructive testing KW - CFRP KW - Durability KW - Inspection PY - 2014 SN - 978-3-00-046740-0 SP - 1 EP - 2 AN - OPUS4-33116 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Helmerich, Rosemarie A1 - Milmann, Boris A1 - Wöstmann, Jens T1 - Non-destructive detection of surface-bond defects in carbon composite-strengthened concrete structures N2 - For almost 15 years, carbon fibre-reinforced polymer (CFRP) plates and sheets have been used for strengthening and repair of civil engineering structures. CFRP plates were applied to upgrade structures for change in use or increasing traffic load. CFRP laminates have also been used to repair deteriorated structures such as multi-storey parking or bridges. The execution quality and condition of the strengthening measure in terms of bond integrity were neither monitored nor tested systematically. Inspectors eventually applied simple hammer knocking during regular main inspection for subjective noise distinction as a measure for eventual insufficient bond. This paper presents the feasibility and the limitations of low-frequency transversal ultrasonic waves with dry-coupling point-contact sensors for inspection and defect detection between CFRP laminate and concrete surfaces. The German Centre of Competence in Civil Engineering (DIBt) has initiated a national research project [Helmerich et al. (2012). Condition analysis of bonded CFRP-applications on concrete structures by means of non-destructive testing [in German: Zustandsuntersuchung von CFK-Klebeverstärkungen an Betonbauteilen mittels zerstörungsfreier Prüfung (ZfP)]. Final, internal project report], carried out at the Federal Institute for Materials Research and Testing (BAM), Germany. The aim of the project was to present a potential non-destructive testing method for bond defect detection as a measure for the durability of the strengthening system more than 10 years after application. KW - Concrete bridges KW - Strengthening KW - Non-destructive testing KW - Composite materials KW - Durability KW - Inspection PY - 2015 U6 - https://doi.org/10.1080/15732479.2013.879322 SN - 1573-2479 VL - 11 IS - 1 SP - 3 EP - 14 PB - Taylor & Francis CY - London [u.a.] AN - OPUS4-33086 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -