TY - JOUR A1 - Berger, Wolfgang A1 - Kalbe, Ute A1 - Goebbels, Jürgen T1 - Fabric studies on contaminated mineral layers in composite liners N2 - The fabric of mineral liner materials that had been exposed to organic compounds over a 12-year period was investigated as part of a wider research project. Macromorphological and micromorphological changes in the fabric were identified using computed tomography and polarisation microscopy. Special care was taken to ensure artefact free sampling and sample preparation, in particular, the drying method used, has a substantial influence on the quality of the thin sections. Fabric changes due to contaminant permeation over several years are, by and large, relatively small and their intensity is material specific. Silty clay CML1, in particular, contains a somewhat greater number of fissures and voids in comparison with the original material. The superposition of various processes in both test procedures and sample preparation may lead to fabric changes which can impede interpretation of the results. KW - Composite liner system KW - Mineral layer KW - Microfabric KW - Macrofabric KW - Computed tomography KW - Microscopy PY - 2002 DO - https://doi.org/10.1016/S0169-1317(01)00095-3 SN - 0169-1317 SN - 1872-9053 VL - 21 IS - 1-2 SP - 89 EP - 98 PB - Elsevier CY - Amsterdam AN - OPUS4-1351 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tomandl, G. A1 - Mangler, M. A1 - Stoyan, D. A1 - Tscheschel, A. A1 - Goebbels, Jürgen A1 - Weidemann, Gerd T1 - Characterization methods for functionally graded materials N2 - In this paper the characterisation of functionally graded materials is elucidated by several different methods. These methods described here are used for the quantitative analysis of materials with a local dependence of microstructure parameters. Using X-ray microscopy (computed tomography) for 3D-measurements and optical microscopy on polished sections for 1D and 2D measurements on the same sample, a ceramic filter consisting of sintered spherical particles, various mathematical evaluation methods are described and compared. KW - Functionally graded materials KW - Computed tomography KW - X-ray microscopy KW - Optical microscopy KW - Ceramics PY - 2006 DO - https://doi.org/10.1007/s10853-006-6632-6 SN - 0022-2461 SN - 1573-4803 VL - 41 IS - 13 SP - 4143 EP - 4151 PB - Springer Science + Business Media B.V. CY - Norwell, Mass. AN - OPUS4-13722 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. A1 - Illerhaus, Bernhard A1 - Goebbels, Jürgen A1 - Bamberg, J. A1 - Heutling, F. T1 - Refraction computed tomography - Application to metal matrix composites N2 - Erstmals wurden MMCs mit Hilfe der Interface-Kontrast verstärkenden Röntgen-Refraktions-Technik in Kombination mit der 3D-CT-Technik untersucht. Die Methode der Röntgen-Refraktions-Topography sowie der Röntgen-Refraktions-Tomography wurden in den letzten Jahren speziell für die zerstörungsfreie Charakterisierung von Leichtbau-Hochleistungs-Werkstoffen wie Verbund-Werkstoffen und Keramiken entwickelt. Die Technik basiert auf der Refraktion von Röntgenlicht an Grenzflächen zwischen Bereichen unterschiedlicher Elektronendichte wie z.B. Faser- und Matrix-Werkstoff. Auf Grund der kurzen Röntgen-Wellenlänge hat der Brechungsindex einen Wert dicht bei eins, sodass der Streuwinkel nur wenige Bogenminuten beträgt. Der Vorteil der kurzen Wellenlänge besteht jedoch darin, dass Poren und Risse detektiert werden können, deren Größe im Nanometerbereich liegen. Damit kann die Refraktions-Technik zum besseren Verständnis von Mikro- und Submikro-Strukturen in der Materialwissenschaft eingesetzt werden. Mit der hier vorgestellten Refraktions-CT wurden Ermüdungsmechanismen an MMCs, bestehend aus SiC-Faser verstärktem Titan (Ti6242) untersucht. Die Messungen wurden am Röntgen-Messplatz der BAM (BAMline) am Synchrotron-Speicherring-BESSY in Berlin Adlershof durchgeführt. KW - X-ray refraction KW - Computed tomography PY - 2004 DO - https://doi.org/10.3139/120.100592 SN - 0025-5300 VL - 46 IS - 6 SP - 314 EP - 319 PB - Carl Hanser Verlag CY - München AN - OPUS4-5870 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -