TY - CONF A1 - Bartscher, M. A1 - Ehrig, Karsten A1 - Staude, Andreas A1 - Goebbels, Jürgen A1 - Neuschaefer-Rube, U. T1 - Application of an industrial CT reference standard for cast freeform shaped workpieces N2 - Industrial computed tomography (CT) today is an important method to analyze defects and to measure the geometry of technical products. The measurement capability of industrial CT often depends on the knowledge of the measurement errors being present. Only with this knowledge, effective corrections are possible by manufacturers, or adapted measurement procedures become possible for the customers. Thus, there is the strong need to have adequate reference standards both for the assessment of general dependencies and for the measurement of task-specific effects. Especially the latter are difficult to assess. This paper shows the application of a versatile dismountable workpiece-near reference body for the use with CT. The reference standard was made from a miniaturized cast aluminium (one-)cylinder head. It can be dismounted into four segments, each featuring reference geometries which enable a registration of CT measured and other reference datasets (e.g. from tactile CMM). The reference standard embodies complex freeform surfaces which are a challenging measurement task for CT and other sensors. Here the application of the reference standard is the study of the influence of material mixes. This is realized by adding pieces of other materials which disturb the mono-material measurement. Results of the application of the reference standard are presented using data from industrial micro-CT systems and CMM reference data. A special emphasis is given on the workflow of the data processing and the data analysis. T2 - International symposium on digital industrial radiology and computed tomography CY - Berlin, Germany DA - 20.06.2011 KW - Industrial reference standard KW - Computed tomographie KW - Freeform shaped workpieces PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-245532 SN - 978-3-940283-34-4 IS - DGZfP-BB 128 (We.4.3) SP - 1 EP - 12 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-24553 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bartscher, M. A1 - Hilpert, U. A1 - Goebbels, Jürgen A1 - Weidemann, Gerd T1 - Enhancement and Proof of Accuracy of Industrial Computed Tomography (CT) Measurements KW - Coordinate Measuring Machine (CMM) KW - X-ray KW - Uncertainty PY - 2007 SN - 0007-8506 SN - 1726-0604 VL - 56 IS - 1 SP - 495 EP - 498 PB - Elsevier CY - Oxford AN - OPUS4-15738 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Bartscher, M. A1 - Hilpert, U. A1 - Goebbels, Jürgen A1 - Weidemann, Gerd A1 - Puder, H. A1 - Jidav, H.-N. T1 - Einsatz von Computertomografie in der Reverse-Engineering Technologie - Vollständige Prozesskette am Beispiel eines Zylinderkopfes T2 - DGZfP Jahrestagung CY - Rostock, Deutschland DA - 2005-05-02 KW - Computertomografie KW - Reverse Engineering KW - Geometriekontrolle PY - 2005 SN - 3-931381-64-1 N1 - Serientitel: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. – Series title: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. IS - 94-CD SP - 1 EP - 12(?) PB - DGZfP CY - Berlin AN - OPUS4-12077 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Bartscher, M. A1 - Hilpert, U. A1 - Wäldele, F. A1 - Goebbels, Jürgen A1 - Weidemann, Gerd T1 - Projekt - Genauigkeitssteigerung von industriellen Röntgen-Computertomografie (CT)-Anlagen für die dimensionelle Messtechnik N2 - Kurzfassung Röntgen-Computertomographie (CT) ist eine industriell eingeführte Technik zur zerstörungsfreien Fehlererkennung. Seit einiger Zeit werden industrielle CT-Anlagen auch zur Geometriebestimmung, d.h. für dimensionelle Messungen eingesetzt. Bei diesen Messungen treten Messabweichungen auf, die wegen komplexer Einflussgrößen derzeit nur schlecht quantifiziert werden können. Die Größe der beobachteten Messabweichungen erschwert zum Teil noch die weitere Anwendung der CT als Messtechnik. Das momentan mit CT messbare Teilespektrum wird bei dickwandigen Bauteilen durch die fehlende Verfügbarkeit von Röntgendetektoren für hohe Energien (speziell Flächendetektoren) beschränkt. Im folgenden wird ein Forschungsprojekt zwischen 10 deutschen Industrieunternehmen und Instituten und zwei deutschen Bundesanstalten (Physikalisch-Technische Bundesanstalt (PTB) und Bundesanstalt für Materialforschung und -prüfung) vorgestellt, dass die Weiterentwicklung der CT als dimensionelle Messtechnik zur Aufgabe hat. Das Projekt hat eine Laufzeit von drei Jahren (Start 01.Okt. 2003). Es werden hier die Projektziele und erste Ergebnisse vorgestellt. T2 - Jahrestagung Zerstörungsfreie Materialprüfung 2004 CY - Salzburg, Österreich DA - 2004-05-17 KW - Dimensionelles Messen KW - Computertomographie KW - Soll-Ist Vergleich von Geometrien PY - 2004 UR - http://www.ndt.net/article/dgzfp04/papers/p17/p17.htm SN - 3-931381-55-2 SP - 1(?) EP - 9(?) PB - DGZfP CY - Berlin AN - OPUS4-5601 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bartscher, M. A1 - Neukamm, M. A1 - Hilpert, U. A1 - Neuschaefer-Rube, U. A1 - Härtig, F. A1 - Kniel, K. A1 - Ehrig, Karsten A1 - Staude, Andreas A1 - Goebbels, Jürgen T1 - Achieving traceability of industrial computed tomography KW - Industrial computed tomography (CT) KW - Coordinate metrology KW - Traceability PY - 2010 DO - https://doi.org/10.4028/www.scientific.net/KEM.437.79 SN - 1013-9826 VL - 437 SP - 79 EP - 83 PB - Trans Tech Publ. CY - Aedermannsdorf AN - OPUS4-20985 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ehrig, Karsten A1 - Bartscher, M. A1 - Goebbels, Jürgen A1 - Härtig, F. A1 - Kniel, K. A1 - Neukamm, M. A1 - Neuschaefer-Rube, U. A1 - Staude, Andreas ED - Denecke, M. ED - Walker, C. T1 - Dimensional control of micro components with synchrotron computed tomography T2 - 20th International congress on X-ray optics and microanalysis CY - Karlsruhe, Germany DA - 2009-09-14 KW - Synchrotron radiation KW - Computed tomography KW - Dimensional measurement KW - Micro components PY - 2010 SN - 978-0-7354-0764-0 SN - 0094-243X SP - 164 EP - 171 PB - American Institute of Physics AN - OPUS4-21293 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ehrig, Karsten A1 - Bartscher, M. A1 - Goebbels, Jürgen A1 - Koch, M. A1 - Staude, Andreas T1 - Einfluss von Materialkombinationen auf das dimensionelle Messen mit Mikro-Computertomographie am Beispiel eines werkstücknahen Testkörpers N2 - Die Computertomographie (CT) hat sich als dimensionelle Messmethode in der industriellen Produktion etabliert. Durch Messungen an speziellen Prüfkörpern ist es möglich, quantitative Informationen über die metrologischen Eigenschaften dimensioneller Messungen zu erhalten. In dieser Arbeit wird einen Aluminium-Guss-Prüfkörper (120 mm x 90 mm x 60 mm) benutzt, mit dem – in der vorliegender Form – auch der Einfluss von Materialien unterschiedlicher Schwächung auf dimensionelle CT-Messungen untersucht werden kann. Der Prüfkörper ist in vier Segmente zerteilt, so dass auch innenliegende, raue Gussfreiformflächen der taktilen Koordinatenmessung zugänglich sind. Durch adaptierte Rubinkugeln als Referenzstrukturen können die CT-Messdaten in taktile Referenz-Koordinatensysteme überführt werden. Um den Einfluss von Materialien unterschiedlicher Schwächung auf das dimensionelle Messen mit CT zu untersuchen, wurden stärker schwächende ZTA-Störkugeln (Zirconia Toughened Alumina) mit zur Ausrichtung geeigneter Symmetriebrechung in der Nähe von ausgewählten taktilen Messstellen angebracht. Zur Bewertung der Messabweichungen dienen taktile Referenzmessungen an den ZTA-Kugeln sowie taktile Messungen an den Freiformflächen des Gussteils, wobei durch ein iteratives Antastverfahren eine verbesserte Erfassung der Geometrie auch bei starken lokalen Oberflächenkrümmungen sichergestellt wird. T2 - DGZfP-Jahrestagung 2011 CY - Bremen, Germany DA - 30.05.2011 KW - Mikro-CT KW - Dimensionelles Messen KW - Testkörper KW - Multimaterial PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-248878 SN - 978-3-940283-33-7 IS - DGZfP-BB 127 (Di.1.B.2) SP - 1 EP - 6 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-24887 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ehrig, Karsten A1 - Bartscher, M. A1 - Goebbels, Jürgen A1 - Schulze, M. A1 - Staude, Andreas T1 - Dimensionelles Messen unter Phasenkontrast mit Synchrotron Computertomographie N2 - Phasenkontrastmessungen haben sich als hilfreich bei der Kantenfindung von Strukturen mit nur geringem Absorptionskontrast erwiesen. Solche Messungen können besonders gut mit monochromatischer Röntgenstrahlung hoher räumlicher Kohärenz durchgeführt werden, wie sie bei der Synchrotron- Computertomographie (SY-CT) benutzt wird. Nachteilig wirken sich allerdings die Phasenverschiebung des Synchrotronstrahls über das Strahlprofil und damit die Kantenverbreiterung in den zu untersuchenden Strukturen aus. Daher ist ein dimensionelles Messen mit normalen Rekonstruktionsverfahren nicht möglich. In der vorliegenden Arbeit werden neue Filterverfahren zur Korrektur der Phasenverschiebung unter Beibehaltung des erhöhten Kontrastes bei der Rekonstruktion angewandt, um ausgewählte einkomponentige Referenzobjekte hinsichtlich der dimensionellen Messeigenschaften zu untersuchen. Als Referenz werden rückgeführte Messungen mit taktilen Koordinatenmessmaschinen herangezogen. Die Untersuchungen wurden im freien Strahl durch Variation des Abstandes zwischen Objekt und Detektor am Strahlrohr der BAM am Helmholtz- Zentrum Berlin für Materialien und Energie - Speicherring BESSY II durchgeführt. T2 - DGZfP-Jahrestagung 2010 CY - Erfurt, Deutschland DA - 2010-05-10 PY - 2010 SN - 978-3-940283-26-9 IS - DGZfP-BB 122 (Di.2.A.3) SP - 1 EP - 9 CY - Berlin AN - OPUS4-23208 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ehrig, Karsten A1 - Staude, Andreas A1 - Goebbels, Jürgen A1 - Bartscher, M. A1 - Koch, M. A1 - Neukamm, M. ED - Kastner, J. T1 - Evaluierung von Testkörpern zur Strahlaufhärtungskorrektur beim dimensionellen Messen mit Computertomographie T2 - Industrielle Computertomografie Tagung CY - Wels, Österreich DA - 2010-09-27 KW - Testkörper KW - Strahlaufhärtung KW - CT KW - Dimensionelles Messen PY - 2010 SN - 978-3-8322-9418-2 SN - 1610-4773 SP - 181 EP - 186 PB - Shaker Verlag GmbH AN - OPUS4-22033 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hilpert, U. A1 - Bartscher, M. A1 - Neugebauer, M. A1 - Goebbels, Jürgen A1 - Weidemann, Gerd A1 - Bellon, Carsten T1 - Simulation-aided computed tomography (CT) for dimensional measurements N2 - Carrying out dimensional measurements by CT means assessing coordinates in space. CT must therefore be treated as a coordinate measuring technique similar to optical or tactile Coordinate Measuring Machines (CMMs). The well-established standards and guidelines for the acceptance- and verificationtesting of CMMs require the use of calibrated reference standards to achieve measurement machine characteristics. Hence, transferring these concepts from coordinate metrology to CT, a dedicated CT-specific reference standard was designed, manufactured and calibrated using a tactile CMM. For comparison purposes, a CAD model was created by reverse engineering using the calibration data. The calibrated model was fed into a virtual CT and the measurement process was simulated. The reference standard was measured by micro-CT. By comparing the characteristics of the measurement output of CT and the output gained from simulation, the influences of measurement artefacts can be judged, for the first time, in analogy to existing Guidelines of coordinate metrology. T2 - DIR 2007 - International Symposium on Digital industrial Radiology and Computed Tomography CY - Lyon, France DA - 25.06.2007 KW - Computed tomography KW - X-ray KW - Simulation KW - Coordinate metrology PY - 2007 UR - http://www.ndt.net/article/dir2007/papers/12.pdf SP - Paper 6, 1 EP - 15 AN - OPUS4-37045 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Hilpert, U. A1 - Härtig, F. A1 - Bartscher, M. A1 - Ehrig, Karsten A1 - Staude, Andreas A1 - Goebbels, Jürgen T1 - Messunsicherheit, Kalibrierung und Normale zur zuverlässigen Rückführung der dimensionell messenden Computertomographie (CT) T2 - 4. VDI-Fachtagung Messunsicherheit - Messunsicherheit praxisgerecht bestimmen CY - Erfurt, Deutschland DA - 0208-11-12 PY - 2008 SN - 978-3-98-12624-1-4 IS - Kap. 31 SP - 1 EP - 14 CY - Düsseldorf AN - OPUS4-18600 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Neugebauer, M. A1 - Hilpert, U. A1 - Bartscher, M. A1 - Gerwien, N. A1 - Kunz, S. A1 - Neumann, F. A1 - Goebbels, Jürgen A1 - Weidemann, Gerd T1 - Ein geometrisches Nomal zur Prüfung von Röntgen-Mikro-Computertomografiemesssystemen KW - Geometrische Normale KW - Röntgen-Mikro-Computertomografie KW - Dimensionelles Messen KW - Messgeräteprüfung KW - Geometrical standard KW - X-ray micro-computertomography KW - Dimensional measurement KW - Instrument testing PY - 2007 SN - 0340-837X SN - 0178-2312 SN - 0171-8096 VL - 74 IS - 11 SP - 565 EP - 571 PB - Oldenbourg CY - München AN - OPUS4-22881 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Neuschaefer-Rube, U. A1 - Bartscher, M. A1 - Neugebauer, M. A1 - Härtig, F. A1 - Goebbels, Jürgen A1 - Ehrig, Karsten A1 - Staude, Andreas T1 - Measurement of micro gears - comparison of optical, tactile-optical and CT-measurements N2 - Micro gears are applied in an increasing quantity in many applications. Therefore, precise measurements are of growing importance to ensure their quality. This contribution describes the measurement of gears of a micro planetary gear set with a tactile probe, a tactile-optical probe, an optical sensor, and computed tomography (CT). For the tactile measurements, a high precision piezoresistive microprobe was used. A so-called fiber probe was applied for tactile-optical measurements. This probe applies image processing to determine the position of the tactile probing element. For all tactile and tactile-optical measurements, single point probing was used. The optical measurements were carried out with an imaging sensor based on focus variation. Due to limited accessibility, on some gears not all regions could be measured by the optical sensor and the tactile-optical probe. In contrast to this, with CT the whole part could be measured with high point density. We used a micro-CT system and carried out measurements with Synchrotron-CT. All the sensors used deliver measurement data in Cartesian coordinates. It is a challenge to transfer these data into coordinates in which gear parameters are defined. For this, special attention must be paid to the determination of the gear axis and to the orientation of the teeth. The applied procedures are detailed for different micro gears. The comparison between data of different measurements was carried out successfully. The deviations between the CT data and the tactile or tactile-optical data lie in the range of only a few micrometers. KW - Micro gears KW - Coordinate metrology KW - Computed tomography KW - Optical sensors KW - Tactile probes PY - 2011 DO - https://doi.org/10.1117/12.872413 SN - 0277-786X SN - 0038-7355 SN - 0361-0748 N1 - Serientitel: Proceedings series – Series title: Proceedings series IS - 7864 SP - 78640H-1 EP - 78640H-9 PB - VDE-Verl. CY - Berlin ; Offenbach AN - OPUS4-25998 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Neuschaefer-Rube, U. A1 - Bartscher, M. A1 - Schulze, M. A1 - Neukamm, M. A1 - Staude, Andreas A1 - Goebbels, Jürgen T1 - Messung von Mikrogeometrien mit industrieller Computertomographie N2 - Die industrielle Computertomographie (CT) ist ein gut bekanntes Verfahren zur zerstörungsfreien Prüfung von Werkstücken. In den letzten Jahren wird die CT aber zunehmend auch für dimensioneile Messungen von Werkstücken eingesetzt. Der wesentliche Vorteil der CT liegt in der Kompletterfassung mit hoher Messpunktdichte, die auch für andere Messverfahren unzugängliche, innere Geometrien einschließt. An kleinen Bauteilen können Strukturen bis herunter zu wenigen Mikrometern gemessen werden, wodurch sich das Verfahren gut für die Messung von Mikroteilen eignet. Nachteilig ist, dass viele Einflussgrößen das Messergebnis beeinflussen, was die Rückführung der Messergebnisse, die Bestimmung der Messunsicherheit und die Definition von Spezifikationen für CT-Anlagen erschwert. Der Beitrag stellt nach einer Einführung in das Verfahren Anwendungsbeispiele der CT an Mikroteilen vor. Darüber hinaus geht der Beitrag auf Prüfkörper und -verfahren zur Einmessung und Überprüfung von CT-Anlagen ein und berichtet über aktuelle Normungsaktivitäten. Abschließend werden Möglichkeiten zur weiteren Steigerung der Auflösung aufgezeigt, um zukünftig möglicherweise auch Nanogeometrien messen zu können. T2 - 4. Fachtagung Metrologie in der Mikro- und Nanotechnik 2011 - Messprinzipien - Messgeräte - Anwendungen CY - Erlangen, Germany DA - 25.10.2011 PY - 2011 SN - 978-3-18-092133-4 SN - 0083-5560 N1 - Serientitel: VDI-Berichte – Series title: VDI-Berichte VL - 2133 SP - 137 EP - 148 PB - VDI-Verl. CY - Düsseldorf AN - OPUS4-26251 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Schulze, M. A1 - Staude, Andreas A1 - Neukamm, M. A1 - Neuschaefer-Rube, U. A1 - Goebbels, Jürgen A1 - Bartscher, M. A1 - Bellon, Carsten A1 - Hilpert, U. ED - Weckenmann, A. T1 - Hochgenaue Geometriebestimmung von Mikrobauteilen mit Computertomographie (CT) N2 - Ziel des Vorhabens ist die hochgenaue und vollständige Erfassung innerer und äußerer Geometrien von Mikrobauteilen mittels Mikro-Computertomographie (µCT). Industriell wichtige Mikrobauteile sind z.B. Einspritzsysteme, Festplattenkomponenten oder Instrumente für die minimal-invasive Chirurgie. Typische Bauteilgrößen liegen hier im Bereich 0,1 mm - 100mm; typische zu messende Strukturen haben Größen von 0,5 µm - 500 µm. Mit klassischen Methoden der Messtechnik ist eine schnelle und hochgenaue Erfassung der gesamten Oberfläche von Mikrobauteilen bisher kaum möglich. Innenstrukturen von Mikrobauteilen können mit keiner optischen oder taktilen Messtechnik zerstörungsfrei gemessen werden. Diese Einschränkungen sollen mittels hochgenauer µCT überwunden werden. Hierzu soll der Messprozess simuliert werden, um die Anwendung von Korrekturverfahren zur Genauigkeitssteigerung zu ermöglichen. CT-Messungen an kalibrierten Mikroprüfkörpern sollen die Korrekturverfahren verifizieren. Für die Kalibrierung der Prüfkörper sollen Multisensor-Verfahren entwickelt und getestet werden. Diese sollen es erlauben, Prüfkörper gleichzeitig hochgenau und mit großer Messpunktdichte zu kalibrieren. Es ist geplant, die an Prüfkörpern erreichten Messunsicherheiten und Auflösungen zum Projektabschluss an realen, industriellen Mikrobauteilen (z.B. Mikrozahnrädern) messtechnisch nachzuweisen. T2 - Abschlusskolloquium DFG Schwerpunktprogramm 1159 - Neue Strategien der Mess- und Prüftechnik für die Produktion von Mikrosystemen und Nanostrukturen CY - Erlangen, Deutschland DA - 06.10.2010 PY - 2011 SN - 978-3-8440-0358-1 SN - 0945-0769 SP - 36 EP - 52 PB - Shaker Verlag GmbH AN - OPUS4-24875 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Staude, Andreas A1 - Bartscher, M. A1 - Ehrig, Karsten A1 - Goebbels, Jürgen A1 - Koch, M. A1 - Neuschaefer-Rube, U. A1 - Nötel, Jörg T1 - Quantification of the capability of micro-CT to detect defects in castings using a new test piece and a voxel-based comparison method N2 - We present a modified aluminium casting which is especially suited as test piece for measuring casting defects and the geometry by means of cone-beam micro-focus X-ray systems, and which may become a reference standard for dimensional measurements and defect detection. To obtain a test piece with inner geometries measured by tactile means, we divided a small aluminium cylinder head into four pieces in such a way that most inner surfaces can be reached with a tactile probe. Reference geometries (spheres and cylinders) were applied to define a coordinate system for aligning the measurements in the disassembled and re-assembled state. The four pieces were re-assembled after the tactile measurement. The test piece also contains casting defects. In order to be able to use the assembled cylinder head as reference sample for defect detection, measurements with higher spatial resolution and better signal-to-noise ratio were performed on the single parts. For improving the reliability of the reference measurements, CT measurements of each part were carried out in three different orientations, and the individual defect detections were combined to obtain a reference data set with a high probability of defect detection and a low rate of erroneous detections. A new method for comparing the defect detection in a CT measurement to a reference data set is demonstrated, which provides individual information on every detected flaw. We discuss the results of measurements in the assembled state with respect to the reference data for flaw detection. KW - X-ray tomography KW - Casting KW - Defects KW - Porosity PY - 2011 DO - https://doi.org/10.1016/j.ndteint.2011.05.006 SN - 0963-8695 VL - 44 IS - 6 SP - 531 EP - 536 PB - Butterworth-Heinemann CY - Oxford AN - OPUS4-24028 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Goebbels, Jürgen A1 - Bartscher, M. A1 - Hilpert, U. A1 - Koch, M. T1 - Methode und Prüfkörper zum Nachweis von Gussdefekten in Aluminiumbauteilen mit Computertomographie T2 - DGZfP-Jahrestagung 2009 CY - Münster, Deutschland DA - 2009-05-18 PY - 2009 SN - 978-3-940283-16-0 IS - DGZfP-BB 115 (Mi.4.B.2) SP - 1 EP - 8 AN - OPUS4-20728 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Staude, Andreas A1 - Goebbels, Jürgen A1 - Bartscher, M. A1 - Hilpert, U. A1 - Koch, M. A1 - Reinhart, C. T1 - Genauigkeitssteigerung der Defekterkennung in Gussteilen mit Computertomographie (CT) am Beispiel eines Aluminium-Zylinderkopfsegments T2 - DACH-Jahrestagung 2008 - Zerstörungsfreie Materialprüfung, ZfP in Forschung, Entwicklung und Anwendung CY - St. Gallen, Schweiz DA - 2008-04-28 PY - 2008 SN - 978-3-940283-09-2 IS - DGZfP-BB 113 (Di.2.A.3) SP - 1 EP - 7 AN - OPUS4-18297 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -