TY - JOUR A1 - Rus, J. A1 - Gustschin, A. A1 - Mooshofer, H. A1 - Grager, J.-C. A1 - Bente, Klaas A1 - Gaal, Mate A1 - Pfeiffer, F. A1 - Grosse, C. U. T1 - Qualitative comparison of non-destructive methods for inspection of carbon fiber-reinforced polymer laminates N2 - In the rapidly expanding composite industry, novel inspection methods have been developed in recent years. Particularly promising for air-coupled testing are cellular polypropylene transducers which offer better impedance matching to air than piezoelectric transducers. Furthermore, broadband transmitters (laser-induced ultrasound and thermoacoustic emitters) and receivers (optical microphones) have opened a completely new chapter for advanced contact-free ultra-sound inspection. X-ray dark-field radiography offers a different approach to detect porosity and microcracks, employing small angle X-ray scattering. These innovative ultrasonic and radiographic alternatives were evaluated in comparison with well-established inspection techniques. We applied thirteen different non-destructive methods to inspect the same specimen (a carbon fiber-reinforced polymer laminate with induced impact damage): air-coupled ultrasound testing (using piezoelectric transducers, broadband optical microphones, cellular polypropylene transducers, and a thermoa- coustic emitter), laser-induced ultrasound testing, ultrasonic immersion testing, phased array ultrasonic testing, optically excited lock-in thermography, and X-ray radiography (projectional absorption and dark-field, tomosynthesis, and micro-computed tomography). The inspection methods were qualitatively characterized by comparing the scan results. The conclusions are advantageous for a decision on the optimal method for certain testing constraints. KW - Carbon fiber-reinforced polymer KW - Air-coupled ultrasound KW - Optically excited lock-in thermography KW - X-ray micro-computed tomography KW - X-ray dark-field radiography PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-509473 DO - https://doi.org/10.1177/0021998320931162 SN - 0021-9983 VL - 54 IS - 27 SP - 4325 EP - 4337 PB - SAGE AN - OPUS4-50947 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tiitta, M. A1 - Tiitta, V. A1 - Gaal, Mate A1 - Heikkinen, J. A1 - Lappalainen, R. A1 - Tomppo, L. T1 - Air-coupled ultrasound detection of natural defects in wood using ferroelectret and piezoelectric sensors N2 - Air-coupled ultrasound was used for assessing natural defects in wood boards by through-transmission scanning measurements. Gas matrix piezoelectric (GMP) and ferroelectret (FE) transducers were studied. The study also included tests with additional bias voltage with the ferroelectret receivers. Signal analyses, analyses of the measurement dynamics and statistical analyses of the signal parameters were conducted. After the measurement series, the samples were cut from the measurement regions and the defects were analyzed visually from the cross sections. The ultrasound responses were compared with the results of the visual examination of the cross sections. With the additional bias voltage, the ferroelectret measurement showed increased signal-to-noise ratio, which is especially important for air-coupled measurement of high-attenuation materials like wood. When comparing the defect response of GMP and FE sensors, it was found that FE sensors had more sensitive dynamic range, resulting from better s/n ratio and short response pulse. Classification test was made to test the possibility of detecting defects in sound wood. Machine learning methods including decision trees, k-nearest neighbor and support vector machine were used. The classification accuracy varied between 72 and 77% in the tests. All the tested machine learning methods could be used efficiently for the classification. KW - Air-coupled transducers KW - Wood KW - Ultrasound KW - Ultrasonic imaging KW - Ferroelectret KW - Machine learning PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-509503 DO - https://doi.org/10.1007/s00226-020-01189-y SP - 1 EP - 14 PB - Springer AN - OPUS4-50950 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate A1 - Dohse, Elmar A1 - Bartusch, Jürgen A1 - Kreutzbruck, Marc T1 - Luftschallprüfung von CFK mit planaren und fokussierenden Wandlern T2 - DACH-Jahrestagung 2015 CY - Salzburg, Austria DA - 2015-05-11 KW - Air-coupled KW - Ultrasonic testing KW - Ferroelectret KW - Cellular polypropylene KW - Transducer KW - Adhesive joint PY - 2015 SN - 978-3-940283-68-9 IS - DGZfP BB 152 SP - 1 EP - 9 AN - OPUS4-34629 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate T1 - Luftultraschallprüfung von CFK mit senkrechter Einschallung und Schrägeinschallung T2 - DACH-Jahrestagung 2015 CY - Salzburg (Österreich) DA - 2015-05-11 PY - 2015 AN - OPUS4-34601 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate T1 - Ultraschallprüfköpfe zur Ankopplung über Luft auf der Basis von Ferroelektreten T2 - Workshop "Innovative ZfP mit bildgebender Ultraschallprüftechnik" CY - Braunschweig, Germany DA - 2014-03-14 PY - 2014 AN - OPUS4-30426 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate T1 - Bestimmung der elastischen Eigenschaften des Polypropylen-Ferroelektrets T2 - DAGA 2014, 40. Jahrestagung für Akustik CY - Oldenburg, Germany DA - 2014-03-10 PY - 2014 AN - OPUS4-30427 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate A1 - Bartusch, Jürgen A1 - Schadow, Florian A1 - Köppe, Enrico A1 - Dohse, Elmar ED - Chimenti, D. E. ED - Bond, L. J. T1 - Focusing of ferroelectret air-coupled ultrasound transducers N2 - Air-coupled ultrasound has been applied increasingly as a non-destructive testing method for lightweight construction in recent years. It is particularly appropriate for composite materials being used in automotive and aviation industry. Air-coupled ultrasound transducers mostly consist of piezoelectric materials and matching layers. However, their fabrication is challenging and their signal-to-noise ratio often not sufficient for many testing requirements. To enhance the efficiency, air-coupled ultrasound transducers made of cellular polypropylene have been developed. Because of its small density and sound velocity, this piezoelectric ferroelectret matches the small acoustic impedance of air much better than matching layers applied in conventional transducers. In our contribution, we present two different methods of spherical focusing of ferroelectret transducers for the further enhancement of their performance in NDT applications. Measurements on carbon-fiber-reinforced polymer (CFRP) samples and on metal adhesive joints performed with commercially available focused air-coupled ultrasound transducers are compared to measurements executed with self-developed focused ferroelectret transducers. T2 - 42nd Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Minneapolis, Minnesota, USA DA - 26.07.2015 KW - Ferroelectret KW - Transducer KW - Air-coupled KW - Ultrasonic KW - Focusing PY - 2016 SP - 080001 PB - AIP Publishing CY - Melville, NY, USA AN - OPUS4-35955 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gaal, Mate A1 - Bovtun, Viktor A1 - Stark, Wolfgang A1 - Erhard, Anton A1 - Yakymenko, Y. A1 - Kreutzbruck, Marc T1 - Viscoelastic properties of cellular polypropylene ferroelectrets N2 - Viscoelastic properties of cellular polypropylene ferroelectrets (PP FEs) were studied at low frequencies (0.3–33 Hz) by dynamic mechanical analysis and at high frequencies (250 kHz) by laser Doppler vibrometry. Relaxation behavior of the in-plane Young’s modulus (Y´ 11~1500 MPa at room temperature) was observed and attributed to the viscoelastic response of polypropylene matrix. The out-of-plane Young’s modulus is very small (Y´33≈0.1 MPa) at low frequencies, frequency- and stress-dependent, evidencing nonlinear viscoelastic response of PP FEs. The highfrequency mechanical response of PP FEs is shown to be linear viscoelastic with Y´33≈0.8 MPa. It is described by thickness vibration mode and modeled as a damped harmonic oscillator with one degree of freedom. Frequency dependence of Y*33 in the large dynamic strain regime is described by the broad Cole-Cole relaxation with a mean frequency in kHz range attributed to the Dynamics of the air flow between partially closed air-filled voids in PP FEs. Switching-off the relaxation contribution causes dynamic crossover from the nonlinear viscoelastic regime at low frequencies to the linear viscoelastic regime at high frequencies. In the small strain regime, contribution of the air flow seems to be insignificant and the power-law response, attributed to the mechanics of polypropylene cell walls and closed air voids, dominates in a broad frequency range. Mechanical Relaxation caused by the air flow mechanism takes place in the sound and ultrasound frequency range (10 Hz–1MHz) and, therefore, should be taken into account in ultrasonic applications of the PP FEs deal with strong exciting or receiving signals. KW - Viscoelastic KW - Cellular polypropylene KW - Ferroelectret PY - 2016 DO - https://doi.org/10.1063/1.4944798 SN - 0021-8979 SN - 1089-7550 SN - 1520-8850 VL - 119 SP - Article Number: 125101 PB - AIP Publishing AN - OPUS4-35956 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate T1 - Focusing of ferroelectret air-coupled ultrasound transducers N2 - Air-coupled ultrasound has been applied increasingly as a non-destructive testing method for lightweight construction in recent years. It is particularly appropriate for composite materials being used in automotive and aviation industry. Air-coupled ultrasound transducers mostly consist of piezoelectric materials and matching layers. However, their fabrication is challenging and their signal-to-noise ratio often not sufficient for many testing requirements. To enhance the efficiency, air-coupled ultrasound transducers made of cellular polypropylene have been developed. Because of its small density and sound velocity, this piezoelectric ferroelectret matches the small acoustic impedance of air much better than matching layers applied in conventional transducers. In our contribution, we present two different methods of spherical focusing of ferroelectret transducers for the further enhancement of their performance in NDT applications. Measurements on carbon-fiber-reinforced polymer (CFRP) samples and on metal adhesive joints performed with commercially available focused air-coupled ultrasound transducers are compared to measurements executed with self-developed focused ferroelectret transducers. T2 - 42nd Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Minneapolis, Minnesota, USA DA - 26.07.2015 KW - Focusing KW - Ferroelectret KW - Air-coupled KW - Transducer KW - Ultrasonic PY - 2015 AN - OPUS4-35957 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Christina A1 - Gaal, Mate A1 - Scharmach, Martina A1 - Bär, Sylke A1 - Lewis, A. A1 - Bloodworth, T. A1 - Guelle, D. A1 - Pavkovic, N. A1 - Steker, I. T1 - Metalldetektor-Tests in Oberjettenberg November 2003 - Bundeswehrteststelle WTD 52 N2 - Dieses Poster befasst sich mit Testfeldern und Kalibrierflächen, Training, Minensuche in den Testfeldern, Ausmessung der Minenanzeigen, Dateiangabe und Analyse und dem Ausgraben der gefundenen Minen T2 - ITEP-Workshop 2003 CY - Berlin, Germany DA - 16.12.2003 KW - Testfelder KW - Kalibrierflächen KW - Minensuche PY - 2003 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-35853 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate T1 - Luftultraschallwandler aus zellulärem Polypropylen T2 - Messe CONTROL CY - Stuttgart DA - 2015-05-05 PY - 2015 AN - OPUS4-33940 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate T1 - Luftultraschallwandler aus zellulärem Polypropylen T2 - Messe SENSOR + TEST CY - Nürnberg DA - 2015-05-18 PY - 2015 AN - OPUS4-33942 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate T1 - Luftultraschallprüfung von CFK mit planaren und fokussierenden Wandlern T2 - DACH-Jahrestagung 2014 CY - Salzburg, Austria DA - 2014-07-20 PY - 2014 AN - OPUS4-31618 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate T1 - Luftultraschall N2 - Dieser Vortrag bietet eine Einführung zur luftgekoppelten Ultraschallprüfung. Es werden die theoretischen Grundlagen erläutert und Beispiele für Anwendungen in der Praxis gegeben. T2 - Schulung Ultraschallprüfung Stufe 3 CY - Berlin, Germany DA - 28.09.2020 KW - Luftgekoppelte Ultraschallprüfung KW - Luftankopplung KW - Ultraschallwandler PY - 2020 AN - OPUS4-51578 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate T1 - Charakterisierung von luftgekoppelten Ultraschallwandlern N2 - Mit dem steigenden Einsatz der luftgekoppelten Ultraschallprüfung steigt auch der Bedarf an verlässlichen Methoden der Charakterisierung der eingesetzten Technik. Mehrere unterschiedliche Verfahren zur Charakterisierung von luftgekoppelten Wandlern und der entsprechenden Gerätetechnik werden verwendet. Prüfkopf-Datenblätter verschiedener Hersteller beinhalten unterschiedliche Prüfkopfparameter, wobei oft eigene Verfahren für die Charakterisierung dieser Prüfköpfe verwendet werden. Diese Vielfalt der Parameter und Verfahren erschwert den potenziellen Kunden den Vergleich zwischen den Prüfköpfen unterschiedlicher Hersteller. Daraus ergibt sich der Bedarf, die Verfahren zur Charakterisierung von luftgekoppelten Ultraschallwandlern zu standardisieren. Vorrangig diese Überlegungen bewegten Hersteller von luftgekoppelten Ultraschallwandlern, Forschungseinrichtungen und Anwender sich zu vernetzen und im Rahmen des Fachausschusses „Ultraschall“ den Unterausschuss „Luftgekoppelte Ultraschallprüfung“ zu gründen. Als erstes Ziel hat sich der Unterausschuss die Erarbeitung einer Richtlinie zur Charakterisierung von luftgekoppelten Ultraschallwandlern gesetzt. Dieser Beitrag ist ein Überblick über viele Methoden zur Charakterisierung von luftgekoppelten Ultraschallwandlern, mit dem Schwerpunkt auf der akustischen Charakterisierung. Zu den wichtigsten Wandlerparametern gehören Empfindlichkeit, Mittenfrequenz, Bandbreite, Fokusgröße und Fokusabstand. Verschiedene Methoden der Schallfeldvermessung werden untereinander verglichen. Diese Überlegungen bieten den Ausgangspunkt für spätere Arbeit an einer Richtlinie zur Charakterisierung von luftgekoppelten Ultraschallwandlern. T2 - DGZfP-Jahrestagung 2021 CY - Online meeting DA - 10.05.2021 KW - Luftgekoppelte Ultraschallprüfung KW - Richtlinie KW - Ultraschallwandler KW - Charakterisierung PY - 2021 AN - OPUS4-52642 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Essig, W. A1 - Bernhardt, Y. A1 - Döring, D. A1 - Solodov, I. A1 - Gautzsch, T. A1 - Gaal, Mate A1 - Hufschläger, Daniel A1 - Sommerhuber, R. A1 - Marhenke, T. A1 - Hasener, J. A1 - Szewieczek, A. A1 - Hillger, W. T1 - Air-coupled ultrasound - emerging NDT method N2 - This paper deals with the state of the art of air-coupled ultrasonic testing. KW - Air-coupled KW - Ultrasonic testing KW - Transducers PY - 2021 SN - 1616-069X VL - 173 SP - 32 EP - 43 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-52231 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Shapovalov, Oleg A1 - Shapovalova, M. A1 - Ossenbrink, R. A1 - Heckel, Thomas A1 - Michailov, V. A1 - Weiss, S. A1 - Gaal, Mate T1 - Verbessern der Korrosionsbeständigkeit eines hochtemperaturbeständigen Ultraschalldämpfungskörpers mittels Laserstrahl-Auftragschweißen N2 - Während in einem konventionellen Ultraschallprüfkopf ein Kunststoffdämpfungskörper mit Kleber oder Öl an einen Piezoschwinger angekoppelt ist, werden als Hochtemperaturlösung feinporöse sintermetallische Dämpfungsmaterialien mit einer Flüssigglasankopplung eingesetzt. Um dabei das Sintermetall vor dem korrosiven Angriff der Glasschmelze zu schützten, wird am Dämpfungskörper gegenwärtig Gold- oder Platinfolie zeit- und kostenaufwendig appliziert. In der aktuellen Arbeit wurde eine Methode zum Korrosionsschutz der sintermetallischen Oberfläche aus rostfreiem Stahl mittels Laser-Pulverauftragschweißen entwickelt. Im Laufe einer Schweißparameterstudie auf dem Substratmaterial aus massivem rostfreiem Stahl wurde die Eignung unterschiedlicher Auftragsmaterialien auf Nickel- und Kobaltbasis untersucht. Dabei wurde zunächst der Einfluss verschiedener Schweißparameter wie Laserleistung, Vorschubgeschwindigkeit und Pulvermenge auf die Auftragsqualität (Nahtform, Vermischungsgrad, Porosität) metallografisch bewertet. Anschließend wurden die aufgetragenen Schichten hinsichtlich ihrer Korrosionsbeständigkeit getestet. Der Kontakt mit einer flüssigen Glasmischung bei 500 °C hat bei keiner der beschichteten Proben sichtbare Korrosionswirkung gezeigt. Als Resultat der Schweißparameterstudie haben sich besonders die nickelbasierten Pulver als gut geeignete Materialien für den Prozess gezeigt. Die identifizierten Schweißparameter wurden im nächsten Schritt erfolgreich an das sintermetallische Substrat angepasst. T2 - DVS Congress CY - Online meeting DA - 14.09.2021 KW - Korrosion KW - Hochtemperaturbeständigkeit KW - Ultraschallwandler PY - 2021 SN - 978-3-96144-146-4 SN - 978-3-96144-147-1 VL - 2021 SP - 370 EP - 377 AN - OPUS4-53362 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate T1 - Schallfeldvermessungen von luftgekoppelten Ultraschallwandlern N2 - Zur Charakterisierung von Ultraschallwandlern finden unterschiedliche Methoden und Verfahren Anwendung. Während sich die ISO 22232:2021 verstärkt auf die Charakterisierung von Kontakt- und Tauchtechnikprüfköpfen konzentriert, wird über eine einheitliche Charakterisierung von luftgekoppelten Wandlern noch diskutiert. Durch die unterschiedlichen Herangehensweisen beinhalten Prüfkopf-Datenblätter oft unterschiedliche Prüfkopfparameter und Schallfeldgrößen, was einen direkten Vergleich und eine Applikation im Feld erschwert. So werden bspw. Wandler nach ISO 22232:2021 standardmäßig im Impuls-Echo-Betrieb charakterisiert. Allerdings ist dies nicht auf die in den letzten Jahren entwickelten luftgekoppelten Wandlertechnologien übertragbar, die nur als Sender oder als Empfänger einsetzbar sind. Daher arbeiten aktuell Hersteller, Forschungseinrichtungen und Anwender gemeinsam im Rahmen des Unterausschusses „Luftgekoppelte Ultraschallprüfung“ der DGZfP an der Erstellung einer Richtlinie. Diese Richtlinie stellt dabei den Anspruch dar, die bestehende Normung um die luftgekoppelte Prüfung zu erweitern und somit die Vereinheitlichung der Charakterisierung dieser Wandler zu erleichtern. In diesem Beitrag werden daher verschiedene Methoden der Schallfeldvermessung vorgestellt, untereinander verglichen und ihre Grenzen beschrieben. Abschließend wird auf die besonders herausfordernde Charakterisierung von und mit breitbandigen luftgekoppelten Sendern und Empfängern eingegangen. T2 - Seminar des Fachausschusses Ultraschallprüfung Konventionelle und innovative Anwendungen der Ultraschallprüfverfahren CY - Berlin, Germany DA - 10.11.2021 KW - Luftgekoppelte Ultraschallprüfung KW - Schallfeld KW - Charakterisierung PY - 2021 AN - OPUS4-53750 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate T1 - Sound field measurements on thermoacoustic air-coupled transducers N2 - There are many different methods to characterize air-coupled ultrasonic transducers for non-destructive testing. Data sheets of various manufacturers contain information about some parameters important for the performance of transducers, but this information is not standardized, so that a comparison between probes of different manufacturers is difficult. Therefore, the German Society for Non-Destructive Testing (DGZfP) is working on a guideline to characterization of air-coupled probes. One of the topics in this guideline is the application of thermoacoustic transducers for the characterization of receivers and another topic is the application of microphones for the characterization of transmitters. In this presentation we compare various characterization methods with the particular focus on the characterization of thermoacoustic transducers using an optical microphone. Both thermoacoustic transmitters and optical microphones have a very large bandwidth compared to conventional air-coupled transducers, but their spectrum is not entirely linear, which needs to be taken into account if they are applied as reference transducers. T2 - JSNDI online workshop “Emerging Technologies of Advanced Ultrasonic Measurement” CY - Online meeting DA - 14.12.2021 KW - Air-coupled ultrasound KW - Transducer KW - Sound field PY - 2021 AN - OPUS4-54195 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hufschläger, Daniel A1 - Gaal, Mate A1 - Ahmadzadeh, Majid T1 - Simulation und Vermessung von thermoakustischen Schallquellen N2 - Zur Simulation des Schallfeldes von beliebig geformten konventionellen Schallquellen existieren viele Ansätze (EFIT, GPSS). Sie alle basieren auf der Annahme eines monochromatischen akustischen Signals, was meist eine gültige Annäherung darstellt. Allerdings sind bei thermoakustischen Quellen aufgrund ihrer Funktionsweise und der hohen Bandbreite viele der existierenden Ansätze nicht direkt anwendbar und können Beobachtungen bei der Vermessung von thermoakustischen Wandlern nicht vollständig abbilden und erklären. In diesem Beitrag wurde die bekannte Methode der generalisierten Punktquellensynthese (GPSS) für die Berechnung von Schallfeldern von thermoakustischen Schallquellen angewendet. Dabei gehen zahlreiche Parameter wie die Dicke und Geometrie der leitfähigen Schicht, Krümmung des Substrats, sowie die Signalform der Anregung in die Simulation ein. Neu an dem präsentierten Ansatz ist die Abweichung von der üblichen monochromatischen Annäherung und die Berücksichtigung der großen Bandbreite von thermoakustischen Wandlern. Für die Validierung der Simulationen wurden Schallfelder von Quellen mit bekannter Anregung und Geometrie breitbandig durch ein optisches Mikrofon vermessen. T2 - DGZfP Jahrestagung CY - Kassel, Germany DA - 23.05.2022 KW - Thermoacoustics KW - Sensor characterization KW - Simulation PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-549944 SP - 1 EP - 7 AN - OPUS4-54994 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -